Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.3 LAccepted-AOC 1 11 118 SRI SAI NILAYAM ROAD NO 06 VASAVI SHIVA NAGAR KUSHAIGUDA HYDERABAD TELANGANA 500062 UDYAM TS 20 0108876 | MEDCHAL MALKAJGIRI | TELANGANA | 500062 | ₹5.3 L | L-1 | Accepted-AOC Accepted as L-1 |
| 2 | L-2₹6.1 LRejected-Finance 1ST FLOOR PLOT NO 16 MAHARSHI DAYANAND SARASVATI MARG SECTOR 88 FARIDABAD 121002 | FARIDABAD | FARIDABAD | HARYANA | 121002 | ₹6.1 L | L-2 | Rejected-Finance Rejected as L-2 |
| 3 | L-3₹11.7 LRejected-Finance NAGPUR MAHARASHTRA 440024 INDIA UDYAM MH 20 0171104 | NAGPUR | MAHARASHTRA | 440024 | ₹11.7 L | L-3 | Rejected-Finance Rejected as L-3 |
| 4 | L-4₹53.1 LRejected-Finance GROUND FLOOR 72 BUSINESS PARK CROSS ROAD C MAROL INDUSTRIAL AREA MIDC ANDHERI EAST MUMBAI MUMBAI MAHARASHTRA 400093 | MUMBAI SUBURBAN | MAHARASHTRA | 400093 | ₹53.1 L | L-4 | Rejected-Finance Rejected as L-4 |
| Sl No | Description | Qty | Unit | M/s A TO Z NDT SOLUTIONS (P) LTD L2 | Bureau Veritas India Pvt. Ltd. L4 | SHUBHAM TECH SERVICES PRIVATE LIMITED L3 | Metron Metallurgical Services Pvt Ltd L1 |
|---|---|---|---|---|---|---|---|
| 1.00NDT and Structural Stability test of CHP/ Bunker of Bangwar UG mine & Damini UG mine of Sohagpur Area.For all the above works, Firm should have NABL Lab/ Government approved Test House Accreditation. | |||||||
| 1.01 | Part A NDT and SS tests for Surface Bunkers of Damini UG mine (Capacity-100 Ton)
The agency shall have valid certificate of accrediatation with the standard ISO/IEC 17025-2017 in the specific discipline of the application Non-Destructive testing methods: vibration & sound test, Ultrasonic thickness test, load test including civil testing like Ultrasonic Pulse velocity, Rebound Hammer, Half Cell Potential, Carbonation test & Deflection/Stability test from National accreditation board for testing and calibration laboratories.
ISNT Level II certificate must in (UT, MT and PT) & Report to be submitted per design basis by using software.
Test to be carried out as per following standard:
1. Ultrasonic Test as per std. SA 609/609-M, IS 7666, ASME Section V, Article 23
2. Magnetic Particle Test as per std. ASME section V, Article 7 & 25, SE 709
3. Liquid Penetrant Test as per Std. ASME Section V, Article 6 & 24, SE 165/SE-165 M
4. Deflection/ Stability Test as per Std. ASCI A360, IS800 & IS875
5. Ultrasonic Thickness Test as per Std. ASTM E797
6. Ultrasonic Pulse Velocity Test as per Std. IS 516 (Part-5, Section-1)
7. Rebound Hammer Test as per Std. IS 516 (Part 5, Section 4)
8. Half-cell Potential as per Std. (ASTM-C876-91)
9. Carbonation Test as per Std. - BS 1881 (Part201)
10. Sound Test as per Std. IS 204
11. Vibration Test as per Std. IS 20816 (Part-1) ISO 2631 (Part-2)
12. Load Test (Static & Dynamic) as per Std. (IS/ISO-4310) | 4 | Nos | 61,000 ₹2.4 L | 4,50,000 ₹18 L | 99,000 ₹4.0 L | 45,000 ₹1.8 L |
| 1.02 | Part B NDT and SS tests for Surface Bunkers of Bangwar UG mine (Capacity-100 Ton)
The agency shall have valid certificate of accrediatation with the standard ISO/IEC 17025-2017 in the specific discipline of the application Non-Destructive testing methods: vibration & sound test, Ultrasonic thickness test, load test including civil testing like Ultrasonic Pulse velocity, Rebound Hammer, Half Cell Potential, Carbonation test & Deflection/Stability test from National accreditation board for testing and calibration laboratories.
ISNT Level II certificate must in (UT, MT and PT) & Report to be submitted per design basis by using software.
Test to be carried out as per following standard:
1. Ultrasonic Test as per std. SA 609/609-M, IS 7666, ASME Section V, Article 23
2. Magnetic Particle Test as per std. ASME section V, Article 7 & 25, SE 709
3. Liquid Penetrant Test as per Std. ASME Section V, Article 6 & 24, SE 165/SE-165 M
4. Deflection/ Stability Test as per Std. ASCI A360, IS800 & IS875
5. Ultrasonic Thickness Test as per Std. ASTM E797
6. Ultrasonic Pulse Velocity Test as per Std. IS 516 (Part-5, Section-1)
7. Rebound Hammer Test as per Std. IS 516 (Part 5, Section 4)
8. Half-cell Potential as per Std. (ASTM-C876-91)
9. Carbonation Test as per Std. - BS 1881 (Part201)
10. Sound Test as per Std. IS 204
11. Vibration Test as per Std. IS 20816 (Part-1) ISO 2631 (Part-2)
12. Load Test (Static & Dynamic) as per Std. (IS/ISO-4310) | 6 | Nos | 45,000 ₹2.7 L | 4,50,000 ₹27 L | 99,000 ₹5.9 L | 45,000 ₹2.7 L |
| 2.00 | Total impact of GST for the purpose of CTC | 1 | Nos | - | - | - | - |
Tender Value
₹11.7 L
EMD Value
₹14,700
Closing Date
11 Nov 2025, 5:00 pmClosed
Staff Officer EnM SECL Sohagpur Area
Staff Officer EnM SECL Sohagpur Area Dhanpuri Distt Shahdol MP 9424141331
NDT and Structural Stability test of CHP Bunker of Bangwar UG mine and Damini UG mine of Sohagpur Area
2025_SECL_346159_1
SECL/SGP/EnM/eT/25-26/353 Date 24.10.2025
Open Tender
Miscellaneous Works
15 days
Bangwar UG and Damini UG mine
As per NIT and Tender documents
5 documents required · 5 mandatory
₹14,700
12 Mar 2026
27 Oct 2025
13 Nov 2025
27 Oct 2025
11 Nov 2025
28 Oct 2025
27 Oct 2025 - 4 Nov 2025
Amount
NDT and Structural Stability test of CHP/ Bunker of Bangwar UG mine & Damini UG mine of Sohagpur Area.For all the above works, Firm should have NABL Lab/ Government approved Test House Accreditation.
Part A NDT and SS tests for Surface Bunkers of Damini UG mine (Capacity-100 Ton) The agency shall have valid certificate of accrediatation with the standard ISO/IEC 17025-2017 in the specific discipline of the application Non-Destructive testing methods: vibration & sound test, Ultrasonic thickness test, load test including civil testing like Ultrasonic Pulse velocity, Rebound Hammer, Half Cell Potential, Carbonation test & Deflection/Stability test from National accreditation board for testing and calibration laboratories. ISNT Level II certificate must in (UT, MT and PT) & Report to be submitted per design basis by using software. Test to be carried out as per following standard: 1. Ultrasonic Test as per std. SA 609/609-M, IS 7666, ASME Section V, Article 23 2. Magnetic Particle Test as per std. ASME section V, Article 7 & 25, SE 709 3. Liquid Penetrant Test as per Std. ASME Section V, Article 6 & 24, SE 165/SE-165 M 4. Deflection/ Stability Test as per Std. ASCI A360, IS800 & IS875 5. Ultrasonic Thickness Test as per Std. ASTM E797 6. Ultrasonic Pulse Velocity Test as per Std. IS 516 (Part-5, Section-1) 7. Rebound Hammer Test as per Std. IS 516 (Part 5, Section 4) 8. Half-cell Potential as per Std. (ASTM-C876-91) 9. Carbonation Test as per Std. - BS 1881 (Part201) 10. Sound Test as per Std. IS 204 11. Vibration Test as per Std. IS 20816 (Part-1) ISO 2631 (Part-2) 12. Load Test (Static & Dynamic) as per Std. (IS/ISO-4310)
Part B NDT and SS tests for Surface Bunkers of Bangwar UG mine (Capacity-100 Ton) The agency shall have valid certificate of accrediatation with the standard ISO/IEC 17025-2017 in the specific discipline of the application Non-Destructive testing methods: vibration & sound test, Ultrasonic thickness test, load test including civil testing like Ultrasonic Pulse velocity, Rebound Hammer, Half Cell Potential, Carbonation test & Deflection/Stability test from National accreditation board for testing and calibration laboratories. ISNT Level II certificate must in (UT, MT and PT) & Report to be submitted per design basis by using software. Test to be carried out as per following standard: 1. Ultrasonic Test as per std. SA 609/609-M, IS 7666, ASME Section V, Article 23 2. Magnetic Particle Test as per std. ASME section V, Article 7 & 25, SE 709 3. Liquid Penetrant Test as per Std. ASME Section V, Article 6 & 24, SE 165/SE-165 M 4. Deflection/ Stability Test as per Std. ASCI A360, IS800 & IS875 5. Ultrasonic Thickness Test as per Std. ASTM E797 6. Ultrasonic Pulse Velocity Test as per Std. IS 516 (Part-5, Section-1) 7. Rebound Hammer Test as per Std. IS 516 (Part 5, Section 4) 8. Half-cell Potential as per Std. (ASTM-C876-91) 9. Carbonation Test as per Std. - BS 1881 (Part201) 10. Sound Test as per Std. IS 204 11. Vibration Test as per Std. IS 20816 (Part-1) ISO 2631 (Part-2) 12. Load Test (Static & Dynamic) as per Std. (IS/ISO-4310)
Total impact of GST for the purpose of CTC
M/s A TO Z NDT SOLUTIONS (P) LTD (BID ID -1195479)
SHUBHAM TECH SERVICES PRIVATE LIMITED (BID ID -1193549)
Bureau Veritas India Pvt. Ltd. (BID ID -1195969)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.14 MB
Tendernotice_2.pdf
PDF • 1.86 MB
Tendernotice_3.pdf
PDF • 0.57 MB
BOQ_358840.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid