Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.2 CrAccepted-AOC NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | ₹5.2 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹5.6 Cr+₹42.1 L (8.12%)Rejected-AOC | ₹5.6 Cr+₹42.1 L (8.12%) | 2 | Rejected-AOC Since not L1 |
| 3 | 3₹5.8 Cr+₹63.8 L (12.3%)Rejected-AOC | ₹5.8 Cr+₹63.8 L (12.3%) | 3 | Rejected-AOC Since not L1 |
| 4 | 4₹5.9 Cr+₹69.2 L (13.3%)Rejected-AOC | ₹5.9 Cr+₹69.2 L (13.3%) | 4 | Rejected-AOC Since not L1 |
Tender Value
₹5.3 Cr
EMD Value
₹5.9 L
Closing Date
26 Dec 2023, 6:00 pmClosed
Chief Engineer RnD Secunderabad
Chief Engineer RnD Picket Secunderabad 500003
PROVISION OF CIVIL WORKS INCLUDING SERVICES FOR PROPOSED OFFICE BLDG RCMA OF DRDL HYDERABAD
2023_MES_620181_1
84001
Open Tender
Construction Works
Lump-sum
365 days
RCMA DRDL Hyderabad
Class A
Category a i
9 documents required · 9 mandatory
₹3,000
Garrison Engineer (I) RnD Kanchanbagh Hyderabad
₹5.9 L
Yes
29 Jan 2024
22 Sept 2023
2 Jan 2024
22 Sept 2023
26 Dec 2023
12 Dec 2023
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of building for office comprising of stilt floor + ground floor + first floor + second floor with RCC columns and beams using M-25 (Design Mix) concrete complete all as shown on drawings and as per specification.
Lump sum price worked out by the Contractor for “EXCAVATION, EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Part - II representing _______ % ______________ percent Above / Below the lump sum price of Rs.20,41,387.25 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of Rs.93,545.10 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of Rs.14,05,829.00 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for "AREA DRAINAGE” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of Rs.2,94,855.69 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for "BOUNDARY WALL” as listed in Schedule ‘A’ Part - VI representing _______ % __________________ percent Above / Below the lump sum price of Rs.7,54,793.25 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for "EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VII representing _______ % __________________ percent Above / Below the lump sum price of Rs.2,32,132.10 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VIII representing _______ % _________________ percent Above / Below the lump sum price of Rs.28,648.00 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “POWER WIRING” as listed in Schedule ‘A’ Part - VIII(A) representing _______ % _________________ percent Above / Below the lump sum price of Rs.4,75,438.00 inserted by the MES in Schedule ‘A’ Part - VIII(A)
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - IX representing _______ % _________________ percent Above / Below the lump sum price of Rs.2,94,068.94 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for "ARBOURICULTURE” as listed in Schedule ‘A’ Part - X representing _______ % __________________ percent Above / Below the lump sum price of Rs.0.00 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “AIR CONDITIONING” as listed in Schedule ‘A’ Part - XI representing ______ % _________________ percent Above / Below the lump sum price of Rs.2,00,930.00 inserted by the MES in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for “LIGHTENING PROTECTION” as listed in Schedule ‘A’ Part - XII representing ______ % _________________ percent Above / Below the lump sum price of Rs.43,111.50 inserted by the MES in Schedule ‘A’ Part - XII
Lump sum price worked out by the Contractor for “TELEPHONE & LAN CONDUIT” as listed in Schedule ‘A’ Part - XIII representing ______ % _________________ percent Above / Below the lump sum price of Rs.71,050.00 inserted by the MES in Schedule ‘A’ Part - XIII
Lump sum price worked out by the Contractor for "FIRE ALARM SYSTEM” as listed in Schedule ‘A’ Part - XIV representing ______ % _________________ percent Above / Below the lump sum price of Rs.7,97,299.00 inserted by the MES in Schedule ‘A’ Part - XIV
Lump sum price worked out by the Contractor for “FIRE HYDRANT SYSTEM” as listed in Schedule ‘A’ Part - XV representing ______ % _________________ percent Above / Below the lump sum price of Rs.8,89,369.00 inserted by the MES in Schedule ‘A’ Part - XV
Lump sum price worked out by the Contractor for "WATER COOLER” as listed in Schedule ‘A’ Part - XVI representing _______ % __________________ percent Above / Below the lump sum price of Rs.0.00 inserted by the MES in Schedule ‘A’ Part - XVI
Lump sum price worked out by the Contractor for "UPS” as listed in Schedule ‘A’ Part - XVII representing _______ % __________________ percent Above / Below the lump sum price of Rs.0.00 inserted by the MES in Schedule ‘A’ Part - XVII
Lump sum price worked out by the Contractor for “WALL PANELLING” as listed in Schedule ‘A’ Part - XVIII representing ______ % _________________ percent Above / Below the lump sum price of Rs.13,21,117.88 inserted by the MES in Schedule ‘A’ Part - XVIII
Lump sum price worked out by the Contractor for "DG SET” as listed in Schedule ‘A’ Part - XIX representing _______ % __________________ percent Above / Below the lump sum price of Rs.0.00 inserted by the MES in Schedule ‘A’ Part - XIX
Lump sum price worked out by the Contractor for “LIFTS” as listed in Schedule ‘A’ Part - XX representing ______ % _________________ percent Above / Below the lump sum price of Rs.76,360.00 inserted by the MES in Schedule ‘A’ Part - XX
Lump sum price worked out by the Contractor for “RCC RETAINING WALL” as listed in Schedule ‘A’ Part - XXI representing ______ % _________________ percent Above / Below the lump sum price of Rs.41,83,938.25 inserted by the MES in Schedule ‘A’ Part - XXI
Lump sum price worked out by the Contractor for “ROAD / HARD STANDING” as listed in Schedule ‘A’ Part - XXII representing ______ % _________________ percent Above / Below the lump sum price of Rs.23,71,512.30 inserted by the MES in Schedule ‘A’ Part - XXII
Schedule 'A' Part - XXIII This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 25.00 to 119.00.
SEWAGE DISPOSAL M&L for Conventional LLDPE septic tank for 25 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Venft shaft, connection etc comlete all as specified and directed.
M&L for Soakage wells of size 1.8 m dia and 3.0 m effective depth with excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25 / SFRC cover, interconnecting pipes of RCC / DWC complete filled with brick bats complete all as specified and directed.
ARBOURICULTURE Clearing grass and removal of rubbish upto a distance of 50 mtr outside the periphery of area cleared complete all as specified and directed.
Preparation of ground by trenching in all type of soils upto a depth of 30 cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth (if needed complete all as specified and directed.
Rough dressing of trenched ground including breaking clods & flooring with water complete all as specified and directed.
Removal of weeds / unwanted grass (Motha etc) with roots & disposal of uprooted material, stone, rubbish etc. with all lead & lifts complete all as specified and directed.
Fine dressing of ground spreading and mixing with the sweet earth (excavated / imported) & Manure (organic manure / cow dung / Sludge) in the ration of 8:1 (08 part of stacked volume of good earth & 01 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8 % stacked volume of manure. Each pit to be mixed with ant termite chemical / granules Thimet 10 G @ 50 - 100 gms / pit. If termite persists repeat the treatment after 06 months by surface spreading the chemical.
Supply of Korean carpet grass by laying direct matting complete all as specified and directed.
Award maintenance of lawn area, green & weed free for 01 Year with standard specification.
Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (Organic manure / cow dung / Sludge) in the ration of 5:1 (05 part of stacked volume of good earth & 01 part of stacked volume of manure). Cost of manure / sludge and good earth if needed tobe paid separately after reduction of 20% of stacked volume of good earth & 8 % stacked volume of manure. Each pit to be mixed with ant termite chemical / granules Thimet 10 G @ 50 - 100 gms / pit. Plant such as Hexora, Nerium speces, Hibiscus spon shall be planted as directed.
Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (Organic manure / cow dung / Sludge) in the ration of 5:1 (05 part of stacked volume of good earth & 01 part of stacked volume of manure). Cost of manure / sludge and good earth if needed tobe paid separately after reduction of 20% of stacked volume of good earth & 8 % stacked volume of manure. Each pit to be mixed with ant termite chemical / granules Thimet 10 G @ 50 - 100 gms / pit. Plants such as Tikoms gadickowd, Uphorbia, Vukorosia shall be planted as directed.
Maintenance for One Year, replacement of sapling, causalities etc.
HEDGE PLANTATION Digging trenches of approved / desired size of L&W (45-50 Cms) X D (30-60 cm) in all type of soil. Railing the trenches with good earth (excavated / imported) Mixed with manure (cow dung / sludge / dump) in the ratio of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment and Thimet 10G granules @ 100 gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation. Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Different colours of pernial flower plants. Plants such as Durauta, Akalysha red or couloued shall be planted as directed.
Maintenance the hedge by regular watering, trimming & pruning etc for one year initially.
BRICK EDGING: Edging with bricks (class-I) laid in (1:2:4), length wise, including required excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within all lead and lifts.
FLOWER BED (ANNUAL): Blue moon, Exora Dwaul.
FLOWER BED (SEASONAL): Marigold, White lilly.
TREE PLANTATION Digging pits in all type of soils and refilling the same with the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 3:1 (03 part of stacked volume of good earth & 01 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with ant termite chemical / granules, Thimet 10G @ 100-200 gm/pt. Avenue / flowering trees pit size 1mts x 1 mts x 1 mts (L X W x D).
Each pit to be added with 100 ms of Thimet 10 g granule to control termite attack (repeat the treatment after 06 months, if termite persists) flooding the pit basin with water, dressing including removal or rubbish & surplus earth, if any, with all lead & lifts.
Supply and Plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of 5’-6’ height, with a clear minimum height of 4’-5’ from basin / ground level after plantation. Staking the tree sapling upto ¾ height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with anti-termite chemical. Trees: Royalpalece.
Maintenance of tree sapling after plantation for 30 days or more as minimum guarantee period for well establishment of tree sapling. Stacking to be continued till free sapling attains the stem strength. Replacement of saplings causalities immediately.
Potted Plants (Indoor): Supply and arranging of healthy grown up plants in plastic pots. Pots of 12” size with bottom plates. 1. Aracapalms - 10 Nos. 2. Ficusresnold - 10 Nos. 3. Furcriaearievated - 10 Nos. 4. Ficausnuda - 10 Nos. Maintenance includes regular watering, loosening of soil, manuring with organic manure and fertilizer mixture, spraying of insecticide and fungicide as and when required trimming and removal of dried leaves and decayed parts of plants to keep them in presentable shape for a period one year.
Potted Plants (outdoor): Supply and arranging of healthy grown up plants in earthen. Cement pots of 12” size. 1. Bird of Paradise - 10 Nos. 2. Mussaenda - 10 Nos. 3. Bougainvillea - 05 Nos. 4. Exora - 05 Nos. Maintenance includes regular watering, loosening of soil, manuring with organic manure and fertilizer mixture, spraying of insecticide and fungicide as and when required trimming and removal of dried leaves and decayed parts of plants to keep them in presentable shape for a period one year.
GOOD EARTH / COW DUNG MANURE: Supply and stacking of good earth / manure from approved source / field of approved quality / Ph & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. cost of good earth to be paid separately.
Providing and fixing G.I. Pipes 25mm dia nominal bore complete with G.I. fittings and clamps including making good the walls etc, complete all as specified and directed.
INTERNAL WATER SUPPLY S&F, two way bib cock, cast copper alloy, chromium plated for size 15mm dia with crutch or butter handle, screwed down for iron pipe complete all as specified and directed.
S&F, health faucet cast copper alloy, chroimum plated including 1 mtr long pipe and all fittings to fix screwed down for iron pipe complete all as specified and directed.
LIFT Supply, installation, testing & commissioning with machine room lift electrically operated with microprocessor based controls, complete with power driven automatic stainless steel (SS) sliding car doors and landing doors having stainless (SS) car enclosure suitable to carry goods at speed of 0.5 M/Sec to serve upto (G+3) with all standard features mentioned below and human interface device (HID) and addition for automatic rescue device (ARD) complete all as specified and as per following technical specifications: Make: OTIS Elevators / Mitsubishi / Schindler / Hitachi / Toshiba / Fujitee India Ltd. Each job 01 Rate to be quoted in quotation bid (BOQ) (a) Type and capacity: Goods lift of 1 Ton (b) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5mm landing accuracy with speed encoder. (VVVF drive) (c) Speed: 0.5 meter per second (d) Travel: Goods lift (Stilt +3 floors) (Stilt floors + Ground floor + First floor + Second floor and shall opening on same side. (e) Required well size: 2215mm x 2200mm deep (approx) without any projected beam / column. (f) Power Supply: 415/440 volts, three phase 50Hz AC. (g) Inner size: 1600mm wide x 1500mm deep, 2200 mm height (approx)
(h) Car enclosure: Stainless steel panels, SS false ceiling (hairline finish) and mirror finish handrail. (j) Flooring: Polished granite flooring (k) Electric light: LED light fittings as per OEM. (l) Fan cross flow fan 02 Nos inside the car of adequate sweep as per manufacturer, Car entrance, Automatic, centre opening, bi-parting sliding doors. (m) Clear opening: 1200mm (wide) x 2000mm (high) (n) Operation door: Automatic operation (p) Control: Simplex full collective with and without attendant (q) Indicators: Hall position indicators for car & landing Direction and position indicator with stainless steel fixtures at all floors. (r) Head room height 4800mm and pit depth 1600mm. (s) Door type : Two-Panel center opening panel 4 STANDARD FEATURES: (a) Anti nuisance car call protection. (b) Automatic car return device (home landing). (c) Independent service (for duplex only). (d) Overloading devices. (e) Nudging. (f) Emergency fireman’s service.
(g) Audible car call button. (h) Emergency car light unit. (j) High performance contact free infrared curtain door protection. (k) Door time protection. (l) Emergency alarm button. (m) Extra door time of lobby & parking. (n) Door open and button. (o) Manual rescue operation. (p) Belt inspection device. ADDITIONAL FEATURES: Automatic rescue device HUMAN INTERFACE DEVICE (HID) (a) Hall button with micro stroke push buttons combined with 16 segment digital LED display position indicator. (b) Full height car operating panel with micro stroke call push buttons (located on side panel). (c) Door open / door closed on car operation panel. (d) 2 way intercommunication system. (e) Dot matrix position indicator. (f) Battery operated alarm bell and emergency light. (g) Fireman’s switch at main body. (h) Manual rescue operation. (j) Call register indicator in all landings. (k) Attendant operation system in car panel. Note: Any civil work shall be done required at site as per Engineer-in-Charge directions.
EXTERNAL ELECTRIFICATION Supply, erecting, testing & commissioning of Transformer 250 KVA capacity outdoor type, Step down 11/0.433 KV, HT with 3 phase and LT with 3 phase, 4 wire system, 50 Hz, double wound copper with Off load tap changer with tapping range +5% to -10% in taps 2.5%, Energy efficient level II, conforming to IS 1180, oil immersed naturally cooled, standards IS-2026. Specification for distrubution Transformers IEC 76 IS-1180. The windings of the transformers shall be connected Delta on the primary side and Y (Star) on the secondary side. The vector group shall be Dyn. II. The temperature rise over ambient shall not exceed the limits top oil temperature rise measured by thermometer: 35 °C, Winding temperature rise measured by thermometer 40 °C. (a) Mounting: Plinth mounted. (b) Type of cooling: ONAN. (c) Load losses at 50% is 920W and at 100% is 2700W I) The following standard fittings shall be provided:- a) Rating and terminal marking plates non detachable - 02 Nos.
b) Earthing terminals with lugs - 02 Nos. c) Oil level gauge indicating three positions of oil marked as follows : Minimum 5 Deg.C, 30 Deg.C, Maximum 98 Deg.C. d) Lifting lugs - 04 Nos. e) Silicagel breathing device of weather proof design - 01 No. (500 gms. capacity). f) Drain pipe of adequate size at the corner from bottom of the tank to the top cover where it is duly bent - 01 No. g) Oil filling hole having 1-1/4 thread (with cover) on the transformer body / conservator - 01 No. h) Bimetallic terminal connectors on the HV/LV bushings as per drawing enclosed - 07 Nos. j) Thermometer pocket - 01 No. k) Platform mounting channel - 02 Nos. l) HT/LT bushings - 03 Nos on HT & 4 Nos on LT, (LT & HT bushings shall be provided with 3 brass nuts & 2 brass washers). m) Explosion vent - 01 No. n) Off-circuit tapping switch with locking arrangement - 01 No. o) Rollers: 04 Nos of sufficient size. p) Cable termination box both HV and LV side. q) Separate Neutral Terminal. r) Raditors. s) Painting: PU light Grey. t) 2 year guarantee embossed plate welded below name plate.
u) Transformer foundation and civil works as per manufacturers recommendation. The rate is deemed to be included in the unit quoted rate. II) Transformers shall be subjected to routine tests at the manufacturer’s works. i) Measurement of winding resistance IS 2026 (Part-I). ii) Measurement of voltage ratio and check of voltage vector relation ship IS 2026 (Part-I). iii) Measurement of Impedance voltage / short circuit impendence and load loss IS 2026 (Part-I). iv) Measurement of No Load loss and current IS 2026 (Part-I). v) Measurement of Insulation resistance IS 2026 (Part-I). vi) Induced of over voltage with stand test IS 2026 (Part-3). vii) Separate source voltage withstand test IS 2026 (Part-3). viii) Impulse voltage test: IS-2026 (Part-III). ix) Temperature rise tests IS 2026 (Part-II). x) Short Circuit test IS 2026 (Part-I).
Supply, laying, testing & commissioning of XLPE insulated earthed cable, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade earthed, cross sectional area 95 Sqmm 3 core including lugs and glands all as specified and directed by Engineer-in-Charge. Note: Excavation, removal & refilling will be measured and paid separately.
Supply, install, test & commission of LT Panel board indoor type, CPRI approved suitable for 3 phase, 4 wire, 415V, 50 Hz, cubicle type dust, vermin proof, weather proof, IP-54 Grade of protection, providing TPN aluminium bus bar of capacity 800 Amps with PVC slevees of colour coding conforming to IS 8623 or as amended upto date including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferouls. The panel shall be painted with anticorrosive coating and finally powder coated of flint grey shade (RAL -7032). The panel should be provided with multifunction meters, voltmeter, 3 phase indicators lamps and the panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. The circuit distribution lines to be marked over the panel using poly venyl reflective stickering (where necessary) complete with following:-
Supply, laying, testing & commissioning of XLPE insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts garde cross sectiona area 120 sqmm 3.5 core including lugd and glands complete all as specified and directed. Note: Excavation, removal & refilling will be measured and paid separately.
Supply, laying, testing & commissioning of XLPE insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts garde cross sectiona area 70 sqmm 3.5 core including lugs and glands complete all as specified and directed. Note: Excavation, removal & refilling will be measured and paid separately.
M&L for cutting existing road / PCC of size 45cm x 60cm for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified and directed.
Supply & laying, GI tubing 150 mm dia light grade for protection of cables and all as specified and directed.
Supply & laying of High Voltage insulating mats rubber mat Class B of 1 MTR x 2 MTR and 2.5mm thickness, conforming to new specification IS: 15652:2006 complete all as specified and directed.
Supply, install, testing & commissioning of vaccum circuit breaker ICOG panel board HT 630 Amps, 11 KV, 18.4 KA, 3 phase, 50 Hz, 3 wire totally enclosed metal clad, extensible type indoor floor mounted horizontal draw, horizontal isolation type vaccum circuit breaker 630 Amps motor operated spring charged having rupturing capacity 350 MVA and VCB comprising of: - (i) Assembly of 3 vaccum interrupters complete with epoxy support insulator and self-aligning finger type isolating contacts. (ii) Hand and motor (220 volt AC) charged independent spring closing / tripping trip free operating mechanism with manual closing and tripping push buttons and mechanical breaker closed / open, spring charged / discharged indication. (iii) Electrical release coil 24V DC - 01 No. (iv) Mechanical operation counter.
M&L for earthing complete with CPRI tested maintenance free chemical tripod earthing using 20mm copper bonded 3m long rod (3Nos) using X-Zel Part I and Part II 20 KG each and Z-Earth 40 KG including inter connection with earth lead burried directly in ground (earth pit not less than 4.0 M deep below normal ground level) with top edge of the electrode 1.5M below normal ground level connected to copper earth strip 25x3mm (up to 7.5m in length from the earth electrode) by means of bolts and nuts check nuts and washers of galvanised iron or steel all as specified and shown in electrical plate No. 5 of SSR Part I including necessary excavation & earthwork in any type of strata, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 8mm dia TMT bars @ 150mm c/c both ways etc complete and connected to earthing test point complete including testing on completion all as specified and as directed.
S&F, copper strip of size 25 x 3mm as earth continuity conductor on epoxy insulators including necessary fixing spares as required at site complete all as specified and directed.
S&F, HT cable route marker with 10cm x 10cm x 5mm thick GI plate with inscription thereon, bolted / welded to 35mm x 35mm x 6mm angle iron, 60cm long and fixing the same in ground complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for XLPE cables / water supply pipes foundation etc and getting out in hard / dense soil complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified and directed by Engineer-in-Charge.
Supply & laying unreinforced precast concrete cable cover, class HV, type 1, flat size 300 x 180 x 40mm for protection of HT cable including taking down unserviceable cable cover complete all as specified and directed.
Supply & laying unreinforced precast concrete cable cover, class LV, type 1, flat size 250 x 150 x 40mm for protection of LT cable including taking down unserviceable cable cover complete all as specified and directed.
EXTERNAL WATER SUPPLY Cutting of existing GI pipe of size 100 mm dia for taking branch connection with reducer 40mm and screwing including providing GI fittings as required at site complete all as specified and directed.
Cutting of existing GI pipe of size 150 mm dia for taking brach connection with reducer 50mm and screwing including providing GI fittings as required at site complete all as specified and directed.
S&F, Monoblock pump set suitable for 230 V, 1 phase, 50Hz system having capacity 1 HP, 1440 RPM, fixed on MS channel with suitable washers / nuts / bolts and also connecting the suction pipes / delivery line & electric connections made at site with all necessary specials i.e. gasket, flanges etc and 'C' channel base for fixing and testing to the entire satisfaction complete all as specified and directed.
WATER COOLER Supply, installation, commissioning of water cooler stainless steel, electric driven single phase having approximate storage capacity 80 ltrs and nominal cooling capacity 40 ltrs per hour with water purifier RO system complete all as specified and directed.
S&F, Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed.
LIGHTNING PROTECTION S&F, aluminium strip of size 25 x 3mm as earth continuity conductor on epoxy insulators including necessary fixing spares as required at site complete all as specified and directed.
S&F, test point consisting of terminal box, drilled and screwed with 22 swg GI cover including 02 Nos 12mm dia 25mm long hexagonal head screws jointing GI and aluminium strips with bolts, nuts and washers on and including jointing plate made of gun metal or phosphor bronze of size 90 x 32 x 8mm complete enclosure / terminal block assy grouted in wall at 600 mm height from the length protection level by means of two Nos 40 x 40 x 5mm MS plate with 6mm dia anchored bolts embedded in wall including nuts and washers all as specified and directed and shown on drawings.
UPS Supply, install, testing & commissioning of UPS (uninterruptible Power Supply) of capacity 30 KVA, 3 Phase, AC, Input 300 to 450 volts, 3 Phase output 415 volts + 1%, 50Hz to provide 30 Minute backup complete with suitable battery bank of suitable capacity including cable connections as required for complete system and all as specified and directed. (i) Offer for numeric 30 KVA / 240 VDC online UPS system which is suitable for 3 : 3 with in built isolation transformer - 01 No. (ii) Offer for 12 V 65Ah SMF batteries - 20 Nos (iii) Suitable MS rock for battery interlink for batteries (with UNINYVIN Cables & 3D Lugs) -01 No.
FIRE ALARM SYSTEM S&F, Fire Alarm Sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 metre with sound output variation of + 5 DB for 500 meter range complete all as specified and directed.
EXTERNAL ELECTRIFICATION (STANDBY DG SET) Supply, installation, testing & commissioning of silent Diesel Engine driven generating set 415 volts, 250 KVA / 200 KW 3 phase 0.8 power factor 50Hz, 1500 RPM, Liquid Cooled, with all complete all connected acessories in all respects for commissioning of the DG set, with latest CPCB-IV norms and as amended upto date published by the Gazette of India New Delhi dated 03 Nov 2022 vide Sl No. 716 Extraordinary Part-II Section-03, sub section (i), self excited self regulated brushless AC generator installed including Acoustic enclosure suitable for ambient condition at Hyderabad including AMF panel and conforming to condition under IS 4722 / 1460, BS 5514 / 2613 / 5000 ISO 8526 / 3046 comprising of the following: - Alternator - Standard design alternator, Power Rating 250 KVA / 200 KW, 3 Phase 4 wire, 415 Volts, 50 HZ, Power factor 0.8 (lagging) Current 348 Amps, net output at site after considering derating as per site conditions at 0.8 (lagging) power factor, 1500 RPM, self exicted, self ventilated, solid state self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of +1% at rated voltage from no load to full load, A1 The alternator shall be conforming to BS 2613 / 5000 and shall be in position to generate supply with frequency regulation with in +1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS-2613 / 5000 / IS-4722.
Make of the Alternator: KIRLOSKAR / STAMFORD / JYOTI / CG / ALSTOM / BHARAT BIJLEE. Diesel Engine: Adequate capacity Diesel Engine suitable for 250 KVA / 200 KW coupled with alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder, multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessoires shall be as under: - Make of Engine: KIRLOSKAR / CUMMINS / GREAVES COTTON / ASHOK LEYLAND / CATERPILLAR Insulation class - 'H', Temperature rise class - 'H', Excitation - Self excited Regulation performance - The voltage is kept constant with + 1%, manual voltage adjustment with in + 5%, Frequency Regulation + 1% Suitable size & suitable number of runs of UG copper cable (Control cable) from Alternator to AMF & RAW Power to AMF Panel is deemed to be include is quoted rate. (i) Flywheel with housing. (ii) Cooling System: Mounted radiator with fan and belts. (iii) Cooling Water Pump: Centrifugal type belt driven. (iv) Exhaust System: As per OEM reccommendation / specification.
(v) Starting System: Electric Self Starter with maintenance free batteries including battery charging alternative belt driven. (vi) Batteries: 12 Volts DC electrical batteries of 180 AH - 02 Nos of maintenance free batteries as per OEM make, complete connected with copper cable PVC sheathed conductor multistranded leads of suitbale length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified and directed. (vii) Fuel tank of adequate capacity: As per OEM norms and specifications designed for above capacity of DG Set. AMF Panel: Auto Main Failure (AMF) Panel made out 3.15mm thick CRCA sheet outdoor type, CPRI approved manufacture or as per OEM weather proof powder coated conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wire AC 50 HZ having aluminium bus bar of capacity required to carry current at 100% load of 250 KVA / 200 KW DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable, all as specified with the following accessories, control cable from Gen Set to AMF Panel. Contactor of Suitable capacity 3 pole with required Nos as per OEM, TP contactor for netural for both supplies. Suitable capacity of MCCB, 4 Pole for both supplies. CTs 350/5A for both the supplies
Push buttons Indication Lamps 2 over load + earth leakage relay Multi functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc. SMPS Battery charge 12V, with trickle and boost charging. ON/OFF Switch. Automatic / Manual Switch. Hooter. Voltage sensing relay. Six window anunciator for fault indications. Acoustic Enclosure: Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet metal will provide easy access for maintenance, repairs and operation. The enclosure is custom to suit conditions, with the following features: - (i) Custom built product for various equipments, with ensure the optimum performance without duration. (ii) 16SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against weathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absoption. Acoustic layers are supported by perforated sheets.
(iii) Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (iv) Special paint treatment with pure polyster powder / epoxy to be provided for better weather resistance. (v) Well designed ventilation system to be provided to put out the heat from the chamber efficiently. (vi) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used.
(vii) Working space is to be provided around the equipment for easy maintenance / repairs. (viii) Necessary cut out provision for entry and exist of fuel lines cable to be incorported in the enclosure as per the requirement. (ix) See through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation. (x) Ducting if required, bellows, mechanical hardware like locks, hinge, fasters etc to be provided. (xi) Deliverables 75DB @ 1 meter at 75% load under free field conditions. The temp inside the enclosure will be with in limit and as per manufacturers recommendations above ambient temp. (xii) The enclsoure should be provided with bulk head light fitting for inside illumination. (xiii) The exhaust pipe along with proper aluminium cladding, shall be laid to 2.5 mtr height of above the adjacent building roof level. The rates for the same are to be included in the quoted rates. (xiv) The batteries should be placed inside the enclosure inside the DG Set on a suitable insulated platform. (xv) The DG set should be provided with external emergency stop push button.
(xvi) Provn of 02 Nos 11 Watts LED lamp fitting of approved Make incl wiring inside canopy with single switch controlled. (xvii) Fuel gauge to be provided with the neck of fuel tank. (xviii) Tools as per manufacturers with the box. (xix) Invents of suitable company be manufacture. (xx) The acoustic enclosure parts shall be of powder coated after pre treatment process. (xxi) Emission limits as per Gazettte of India, extraordinary, Part-II, Section 3, sub-section (i) for new diesel engine with capacity 250 KVA / 200 KW should be the following: - (a) NOx (Oxides of nitrogen) = _0.67 (g/kW-hr) (b) HC (Hydrocarbon) = 0.19 (g/kW-hr) (c) CO (Carbon Monoxide) = 3.5 (g/kW-hr) (d) PM (Particulate Matter) = 0.03 (g/kW-hr) (e) Smoke limit (light absorption coefficient) = 0.7 (m-1)
(e) Civil Work: All civil works including RCC / PCC platform 1:3:6 type C2 and related to foundations including of panel and equipments including of panel and equipments including making good and existing structure of disturbed during installation and commissioning of Gen Set, The depth of the foundation shall be minimum 300mm with anti vibration pads or as recommended by the manufacturer. The foundation drawing for DG Set shall got be approved by GE before laying of foundation. The Contractor has to obtain approval for RCC / PCC foundation for the DG Set with the manufactures, Rates shall be quoted accordingly with written certificate from the manufacturers for the same.
M&L for cutting existing road / PCC of size 45cm x 60cm for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified and directed.
Supply & Laying GI pipe light grade incuding fittings for cable protection including sealing both ends and all as specified & directed for size 80mm dia. Make: Tata / Jindal / Zenith / Swastik / Prakash.
FIRE FIGHTING SYSTEM S&F, stand post made out of MS pipe of size 80mm dia heavy grade of 1.2 mtr height and providing necessary flanges at both ends suitable for fire hydrant single out let complete including flanged reducer and other fittings suitable for stand post with necessary PCC 1:3:6 type C2 in bedding complete all as specified and directed.
S&F, Fire hose cabinet box of size 750 x 800 x 300 mm, made out from 16 guage MS sheet with double leafed glazed shutters (glazed with 4 mm thick glass) for keeping canvas hose, branch pipe, nozzle with locking arrangement complete all as specified and directed.
S&F, Air release valve suitable for fire fighting system conforming to IS 14845 complete with all jointing materials complete all as specified and directed.
Supply, install, test & commission of LT Panel board out door, cubicle type suitable for 3 phase, 4 wire system of CPRI approved made out of 3.15mm thick CRCA sheet duly powder coated painting in 7 tank process, dust and vermin proof, weather proof, ventilation system IP-54 Grade of protection, providing bus bar of capacity 250 Amps rating including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferouls. The panel shall be painted with anticorrosive coating and finally powder coated of flint gray shade (RAL-7032). The panel should be provided with multifunction meters, voltmeter, 3 phase indicators lamps and the panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. the circuit distribution lines to be marked over the panel using poly venyl reflective stickering and panel shall be installed on PCC platform in PCC 1:2:6 type C2 foundation complete and comprising of the following: -
INCOMING (a) On-Load change over switch of capacity 160 Amp, 4 Pole, 415Volts -01 No. (b) MCCB 160 Amps, 4 pole, 25 KA with adjustable overload setting (minimum 70% to 100%) - 01 No. (c) Digital Multi function meter with all accessories -01 No. (d) LED indicating lamps RYB - 01 Set. OUT GOING (a) MCCB TP 32 A, 16KA with adjustable overload setting (minimum 70% to 100%) - 03 Nos. (b) DOL starter 3 phase 415 Volts suitable for 10 HP pump set - 02 Nos.
TELEPHONE CONDUIT / LAN-WAN CONDUITS S&F, telephone jack 2 way complete all as specified and directed.
INTERNAL ELECTRIFICATION M&L for point wiring for 5 pin 6 Amps socket outlet point on the same board with other switches complete with 1.5 sqmm single core, PVC insulated, unsheathed, multistranded copper conductor cable 1100 volts, FRLS grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit 25mm dia medium grade confirming to IS-9537 and conduit accessories concealed in wall / beams / columns etc with and including modular GI flush boxes of suitable size with modular inner and outer plate and providing modular switches 6A and modular socket outlet 5 pin 6A including 1.5 sqmm single core, PVC insulated, unsheathed, multistranded copper conductor cable 1100 volts, FRLS grade as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
Point wiring complete with 1.5 sqmm single core, PVC insulated, unsheathed, multistranded copper conductor cable 1100 volts, FRLS grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit 25mm dia medium grade confirming to IS-9537 and conduit accessories concealed in wall / beams / columns etc including 1.5 sqmm single core, PVC insulated, unsheathed, multistranded copper conductor cable 1100 volts, FRLS grade as earth continuity conductor and connecting to common earth dolly for socket outlet point 3/5 pin, 5 Amps on independent board controlled by one switch complete all as specified and directed.
All as per Sl item No. 83 above but with 2.5 sqmm cable for 6 pin, 15 Amps socket outlet point on independent board. Note for Sl item Nos. 83 & 84: Modular flush boxes with modular frame, cover plate and modular switch / sockets will be measured and paid separately.
S&F, MCCB with rating of 63 Amps, 415Volts, 4 pole with 16kA breaking capacity, thermal magnetic adjustable of overload & short circuit release with electronic earth leakage module confirming IS-13947 & IEC 60947-2 and the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity (Icu). MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and directed.
S&F, sheet metal enclosure factory made with 2 mm thick CRCA sheet suitable for mounting MCCB upto 100 Amps, 4 pole conforming IS 61439-3, IK-08 protection including necessary cable glands for connecting the cable complete all as specified and directed.
S&F, LED fitting indoor Batten light, 1 x 20 w, output 6500 lm 230v Energy efficient, Box type aluminium housing with drive, connecter block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make: Havells cat part No. ENDURALINEARNEOBS20WLED865SPCSS or techno commercially equivalent in Philips / Wipro.
S&F, LED fitting indoor Batten light, 1 x 10 w, output 6500 lm 230v Energy efficient, Box type aluminium housing with Drive, connecter block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make: Havells cat part No. ENDURALINEARNEOBS10WLED865SPCSS or techno commercially equivalent in Philips / Wipro.
S&F, 2x2 recessed mounted energy efficient LED luminaire 36W with luminous efficacy of 120lm/watt, 5700 K CCT with electronic driver suitable for false grid ceiling complete with all accessories prewired and connecting up with three core 1.5sqmm round PVC copper conductor cable complete all specified and directed. Make: Havells cat part No. PLANO2X2PLR36WLED857S or techno commercially equivalent in Philips / Wipro.
S&F, LED post top lantern 35W, 5700K, energy saving, environmental friendly, designed with symmetrical light distribution, spum aluminium landscape luminaire, die cast aluminium landscape IP 65 luminaire suitable for pole dia 76mm dia complete all as specified and directed. Make: Havells cat part No. CORALPT35WLED757PSYMTOPC or techno commercially equivalent in Philips / Wipro.
S&F, LED road way lighting luminaries 25W with Pressure die-cast powder coated LED suitable for Building security light clear acrylic cover and complete accessories including Drive with suitable connection complete all as specified and directed. Make: Havells cat part No. ENDURASUNDOWNSL25WLED765PASYBOPCIHD or techno commercially equivalent in Philips / Wipro.
S&F, Bollard light fitting LED 10W, 230V, 50 Hz with Pressure die cast powder coated housing with PC diffuser efficient high output SMD LED for Garden, Pathway etc. lighting IP 66 protection and all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make: Havells cat part No. MOUNTBL10WLED830PSYMTOPMMA or techno commercially equivalent in Philips / Wipro.
S&F, exhaust fan 300mm sweep, single phase, matalic body and fixing arrangement on wall by providing suitable hole including electric connection by providing three core copper cable from ceiling rose to fan and writing MES number with black paint complete all as specified and directed.
S&F, ceiling fan 1200mm sweep, single phase, 26 Watts, BLDC type, 5 star rated complete with down rod, blades, canopy etc including electric connection by providing three core copper cable from ceiling rose to fan and writing MES number with black paint complete all as specified and directed.
S&F, wall mounted fan 400 mm sweep 230 Volts, 50 Hz sweep with all the necessary connections by providing electrical connection from ceiling rose to wall mounted fan and writing MES number with black paint complete all as specified and directed.
POWER WIRING S&F in replacement VTPN DB 4 way (double door) sheet metal enclosure factory made IP 54 suitable for MCCB 415 volts incomer and MCBs as outgoing with 250 Amp rated copper busbar, neutral & earthing link bar, flush / surface mounting complete including required MCB and necessary lugs and thimbles as per site requirement complete all as specified and directed.
S&F, industrial interlocked switched sockets surface / wall mounting socket 63 Amps 3P+N+E4 pole with straight plug 63 Amps 3P+N+E, IP 66 protection and sockets enclosure DX3 cabinet IP 66 protection 5 module fixed on wall / surface iwth including incoming MCB TPN 63 Amp, 4P, FP complete all as specified and directed.
S&F, industrial interlocked switched sockets surface / wall mounting socket 32 Amps 3P+N+E4 pole with straight plug 32 Amps 3P+N+E, IP 66 protection and sockets enclosure DX3 cabinet IP 66 protection 5 module fixed on wall / surface iwth including incoming MCB TPN 63 Amp, 4P, FP complete all as specified and directed.
AIR CONDITIONING Supply, install, test & commissioning of Air cooled Variable Refrigerant Volume / Flow (VRV/VRF) outdoor units (working and standby) with all inverter scroll compressor in each individual unit, preferbly all compressors of suitable capacity, air cooled copper condenser coils must have Ocien Black / Blue Fins coatings for corrosion resistance, condenser, fan motor shall be weather proof, brushless DC drive, fan shall have lower vibration, motor shall have minimum 10 steps and air flow resistance with protective grill, suitable for 380 -420 volts, 3 phase + N, 50 Hz, AC supply and shall deliver 100% capacity at 43 degree centrigrade temperature and shall be suitable for operation in upto 50 degree centigrade ambient without tripping or failure, minimum full load coefficient of performance (COP) must be 4.1 and minimum part load COP must be 7.2, defrost technology, 6 bypass valve compressor, including Regrigerant R-410A with first charge for refrigerant gas, suitable PCC foundations, including loading / unloading and shifting to floor / terrace and connecting earthing for outdoor units from the panel of following capacities / units, complete all as specified and directed. Note: Refrigerant gas suitable for VRV / VRF air conditioning plant shall be measured and paid separately under relevant item of Schedule.
30 HP (18 HP x 1 No + 12 HP x 01 No.) for First Floor
30 HP (18 HP x 1 No + 12 HP x 01 No.) for Second Floor
24 HP (12 HP x 1 No + 12 HP x 01 No.) for Third Floor
Supply, install, test & commissioning of VRV / VRF based 4-Way Cassette type Ceiling mounted indoor machine complete with Fan & Cooling Coil suitable for R-410A, return air filter, insulated drain tray, drain pump complete with all necessary controls incluing air and regrigerant temperature sensors and electronic expansion valves providing individual, variable refrigerant flow, the electronic expansion valve of indoor unit shall be controlled by the microporcessor control system via a contorl board within the indoor unit that includes a unit auto address recognition system including cordless remote of each unit of the following capacities / units complete all as specified and directed.
Indoor split type unit 1.5 TR.
4 way Cassette Unit - 2.0 TR/883 CFM, (Size 840 x 840 x 288 mm).
4 way Cassette Unit - 2.5 TR/1400 CFM, (Size 840 x 840 x 288 mm).
Supply, install, test & commissioning of hard drawn copper refrigerant for VRF copper piping indoor and outdoor units for both one run supply and one run lines with necessary copper fittings, laid neatly, secured with GI clamps and wall brackets with pipe supports as per techinical specifications, at every 1.5 meter interval and at bends including insulation with 19/13mm thick class "O" nitrile rubber, UV treatment (coating) for exposed refrigerant piping insulation complete all as required at site as per specifications of the following sizes, complete all as specified and directed.
S&F, Y/T joints for indoor units and outdoor units suitable for refrigerant pipe of any size as per manufacgture's recommendation complete all as specified and directed.
M&L for PCC concrete bid with PCC 1:2:4 type C1 suitable for VRV / VRF outdoor units with vibration and isolation pads as required for following capacity plants all as specified and directed.
30 HP for First Floor
30 HP for Second Floor
24 HP for Third Floor
M&L for fixing of indoor units by providing rod / wall supports to avoid any kind of vibration complete all as specified and directed.
Supplying & filling refrigerant gas suitable for VRV / VRF air conditioning plants as recommended by OEM including testing for its leakage complete all as specified and directed.
GI perforated cable trays made with high grade strength sheet steel having minimum thickness of 1.6mm of width 225 mm and height not less than 50 mm and depth as per the site requirement and fixing on angle supports or threaded rods suspended from ceilings as required at site complete all as specified and directed.
Supply, install test & commission of LT Panel in door type made out of 2 mm thick CRCA sheet, Cubicle type, as per CPRI approved for 415 V, 50Hz, rated fault current : 50KA for 0.5 sec with internal arc containment dust, vermin proof, weather proof, IP-54 Grade of protection, providing bus bar of capacity 400 Amps rating including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferouls. The panel shall be painted with anticorrosive coating and finally powder coated of flint gray shade (RAL-7032). The panel should be provided with multifunction meters, voltmeter, 3 phase indicators lamps and the panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. The circuit distribution lines to be marked over the panel using poly venyl reflective stickering (where necessary) complete with following: -
S&F, powder quoted grill with collar damper complete all as specified and directed.
S&F, RJ 45 jack with gang box and outer plate for LAN connection complete all as specified and directed.
Supplying & drawing of UTP 4 pair CAT 6 LAN 2 run cable in the surface / recessed steel / PVC conduit as required complete all as specified and directed.
S&F, 5 pair telephone wire in PVC conduit as required complete all as specified and directed.
R. Wadhumal and Sons
Kanika Construction Company
BRITE INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .