| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.5 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹42.0 L+₹1.0 L (2.55%)Rejected-Finance D 91 BLOCK D AMITY GREEN HASEMAU LUCKNOW PIN 226028 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226028 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹42.3 L+₹1.3 L (3.29%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹42.4 L+₹1.4 L (3.45%)Rejected-Finance 58 SHAHEED NAGAR OPP BHIMRAO AMBEDEKAR UNIVERSITY RBL ROAD LUCKNOW 226025 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226025 | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹43.4 L+₹2.5 L (6.05%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 5 | Rejected-Finance Being other than L-1 |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
6 Feb 2021, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW
SPL REPAIR TO BOUNDARY WALL OF JCO FAFA ACCN AT RA BAZAR AND OTHER SANCTIONED WORK IN AREA OF AGE BR-II UNDER GE (EAST) LUCKNOW
2021_MES_411413_1
GE/E/LKO/T-59 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Lucknow Cantt
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GE EAST LUCKNOW
₹92,000
Yes
12 Feb 2021
11 Jan 2021
8 Feb 2021
11 Jan 2021
6 Feb 2021
25 Jan 2021
Amount
Taking down cement plaster on brick walls including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of brick work built in cement mortar including all of quoins, arches, pillers etc.but excl. ashlar facings and precast concrete articles complete all as specified and directed.
Surface excavation soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in post holes (or similar holes) in soft/loose soil, each not exc 0.5 Cum. (0.55mX0.55mX1.5m deep), getting out, and removing soil to a distance not exc 50m complete all as specified and directed
Returning filling including spreading, levelling, watering and well ramming in layers not exc. 25cm complete all as specified and directed
Removing surplus excavated materials not exceeding 50 Mtr and depositing where directed at alevel not exceeding 1.5 Mtr above the starting point.
M & L for PCC (1:5:10) type E-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M & L for brick work using fly ash bricks straight or curved on plan exc. 6 M mean radius built CM 1:6 complete all as specified and directed.
Ditto all as per item No 10 above but except bricks
M&L rendering 10mm thick in cement plaster 1:4 on surfaces fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L rendering 15mm thick in cement plaster 1:4 on other than fair surfaces and surface finished even and smooth without using extra cement complete all as specified and as directed.
M & L 15mm thick plaster in C.M. 1:6 on other than fair surfaces of walls finished even and smooth with neeru finish to plastering complete all as specified and directed.
M&L PCC 1:2:4 type B-0 (using 12.5 graded stone aggregate) as in coping, bands, bed plates etc and similar works complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length bent to shape required including hooking ends and binding with mild steel (annealed) wire not less than 0.9mm dia complete all as specified and directed.
Description all as per item No 16 above but mild steel TMT bar 6mm to 8 mm dia.
Ditto as per item 16 but 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders.
M & L for RCC (1:1.5:3) type B1 (using 20 mm graded stone aggregate) as in roof slabs, shelves etc complete all as specified and directed.
M & L for RCC (1:1.5:3) type B1 (using 20 mm graded stone aggregate) as in lintel, band etc etc complete all as specified and directed.
Use and waste form work to soffits of roof slabs, floor slabs and similar work not exc 200 mm thick fair finished surfaces (flat) complete all as specified and directed.
Use and waste form work to sides of beams, lintel and slab etc and similar work not exc 200 mm wide fair finished surfaces complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type C-2 using 40mm graded stone aggregates as in sub base of floors complete all as specified and directed.
M & L for 40mm thick cement concrete type B-1 1:2:4 (using 20mm graded stone aggregate) as in floors,finished even & smooth without using extra cement complete all as specified and directed
Supply only glass dividing strips, 3mm thick and 38 mm wide complete all as specified and directed
M&L for glass coping over boundary wall top with broken glass complete all as specified and as directed.
S & F mild steel work as in fencing posts incl. cutting tops to shape as directed , drilling holes, notching for wire etc.,flat iron fillets (for securing wire mesh etc.)incl. all necessary drilling, bolting or riveting etc. and similar work complete all as specified and directed.
S&F galvanized 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc complete all as specified and directed. (each line wire to be measured).
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment on wall and applying three coats of white wash on prepared surface complete all as specified and directed.
S & F 150 mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete (1:4:8) type D-2.complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc.
M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 CM width or grith and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L 20 mm thick granite (of any type) tiles machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over 15mm thick rendering in CM 1:3 including grinding and polishing complete all as specified and directed.
M&L for mild steel framed work as in doors or gates of angle iron or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering. Doors etc. tobe prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel, sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L for 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in gate, wall etc complete all as specified and directed.
Demolition of cement concrete reinforced as in chullah hoods , shelves and plate form etc complete all as specified and directed
M&L precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in man hole/drain cover slabs and set in CM (1:4) complete all as specified and directed.
M&L cement concrete 1:3:6 type C-2 (40mm graded aggreagate) in foundation filling and mass concrete complete all as specified and directed.
M&L cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in surface channel, coping, and drains etc. complete all as specified and directed.
S & F 450 mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete (1:4:8) type D-2.complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling/sub-base to floor etc and mass concrete complete all as specified and as directed.
M/L for P.C.C 1:2:4 type B1 using 20mm graded stone aggregate as in foundation/footing complete all as specified and as directed.
M&L for steel work as in tubular trusses incl special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-11979 Gde St 270 complete all as specified and as directed.
S&F rolled mild steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed.
S&F MS Screw bolts 12mm dia (Machine Made ) with hexagonal or square heads at one end and screwedat the other end or screwed both ends,each screwed end to be fitted with washers and one end hexagonal or square nut, diameter of shank 11 to 15 mm, length of bolt not exc 5 cm long complete all as specified and as directed.
M & L PCC 1:2:4, type B-0, with 12.5mm stone aggregate 40 mm thick in Damp Proof Course to horizontal or vertical surfaces including necessary formwork using water proofing compound as per manufacture's instruction complete all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick or concrete surfaces, finished the surface even and smooth with using WPC @ 2% by weight of cement complete all as specified and as directed. (Note- WPC shall be measured and paid separately)
M&L for 10mm thick cement plaster on other than fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth complete all as specified and directed.
M&L for rendering 5mm thick on concrete surfaces of ceiling in CM 1:3, finish the surface even & fair complete all as specified and directed
M&L for 15 mm thick cement plaster in CM 1:3 on top of RCC Roof Slab with using water proofing compound 3% by weight of cement, finish the surface even & fair complete all as specified and directed
Supply only integral water proofing compound (ISI marked) complete all as specified and as directed.
M&L for preparation of newly plastered surface and applying two coats of cement based paint over one coat of Ppimer on wall complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone for embedding of hold fast/ bed block etc complete all as specified and directed.
S&F mild steel, plain, black sheet 0.8mm thich in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as requiredM&L factory made 30 mm thick flush shutters, solid core construction, with block board 3 core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F for expanded metal not exc 4 Kg per sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering,cladding to wall etc, fixed with self tapping screws ,complete all as specified and as directed.
S&F pre-painted galvalume zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws complete all as specified and as directed.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in sub base of floor of shed etc complete all as specified and as directed.
M&L for hard core of brick aggregate of guage n.exc 63 mm deposited, spread, levelled and rammed to atrue surface, complete all as specified and as directed.
M&L for 50 mm thick PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in plinth protection laid in bays not exc 1.5m with expansion joints 30x10mm filled with mixture of hot bitumen and sand, finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L precast conctete coloured rubber moulded Paver block any shape and size conforming to IS 15658-2006 of 80mm thickness,M-40 grade in set jointed and pointed with grey cement slurry and pigment to match the floor approved design /colour set and bedded over and including 25mm thick sand laid over compacted sub soil complete all as specified and as directed.
M & L for machin cut kota stone slab flooring, 18 to 22 mm thick (size not less than 400mmx400mm) laid over and including cement screed bed 15 mm thick in cm (1:4) ,jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for kota stone slab 18-22 mm thick in riser of steps,skirting ,dado and etc laid over cement screed 10 mm thick in CM (1:4) and jointed with pigment to match the shade of the slab complete all as specified and directed.
S.&F false ceiling with 4mm thick E-Board "Everest" make white pre laminated set embosed reinforced designer ceiling board of oceanic texture fixed with GI embosed grid frame work of size not more than 600mmx600mm having 24mm wide T-section, runner made of 0.33mm GI sheets and angle made of 0.45mm GI sheet suspended with 4 mm dia GI wire and leveling clips including two coats of oil bound distemper complete all as specified and as directed. Note: all exposed surface of grid work shall be powder coated white
S &F aluminium anodised partition wall with 5.50mm thick glass and/or 12mm thick prelaminated particle board exterior grade decorated both side and 38mmx63mm size anodised aluminium section frame work fixed with aluminium and rubber beading and fixing arrangement for fixing the framework to wall/floor and frame to frame complete all as specified and directed
M&L for applying two coats of oil bound distemper over a coat of primer over Birla white wall putty after complete removal of existing treatment on old plastered surface including necessary preparation complete all as specified and directed
S&F in repair PVC sheet wall panelling of thickness 5 mm consisting of panels of desire size stuck of inner frame work of 50 mm wide strips of 5mm thick prelam PVC sheet. The strip should have in their centre a grove of 6 mm width and 1 mm depth for sinking the head of the screw used to fix the strip to the wall vertically at an equal interval of 10" between two strips. The PVC strips shall be fixed to the wall using 65 mm long MS screw through the groove in the strip by using PVC Fasteners. The distance between two screw shall not be more than 200 mm. A groove of 2 mm may be left at the joint of two paanels for aesthetic looks. The exact size of the panel aand correspondingly of the grid maay vary depending on the size of the wall. Optinally strips of 5mm thick PVC sheet of width 75 mm feathered at the edge shall be stuck t the places where two panels are joined. using solvent cement complete all as specified and directed
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / fan point controlled by one switch.
All as per srl item No 69 here-in-before but one 3 pin socket outlet, 05 Amps, independent with cable 1.5 Sq mm size.
All as per srl item No 69 here-in-before but one 3 pin socket outlet 05 Apms point on the same board with other switches with cable 1.5 Sq mm size.
All as per Serial Item No 69 here-in-before but one 3 pin socket outlet, 15 Amps, independent with cable 2.5 Sq mm size.
S&F switch piano flush type, single pole, one way, 05 Amps complete all as specified & directed.
S&F socket outlet 2 in 1, 3 pin, 05 Amps complete all as specified & directed.
S&F switch socket combination 2 in 1, 3 pin, 05 and 15 Amps, flush type, universal complete all as specified & directed.
S&F stepped type, electronic fan regulator, flush and socket type on the existing phenolic laminated sheet humfree 2 module ISI marked etc as required complete all as specified & directed.
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified & directed.
S&F in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed. Make : Crompton, Cat No : LBHE-10-CDL or equivalent in Havells, Cat No : RUGBYNEONFT10WLED760SSYMBOPC, PHILIPS Cat no WT202WLED6SCWPSUS2PC
S&F in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : IGP131LT8-16& LT8-20-865-2 or Havells, Cat No : REGALBATTENT8UPT01X22WSSBS & PHOTONULTRA1213T8SSTL20WLED865SPC,philips cat no TMC
S&F in replacement of LED security light fitting 45 watt, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed. Make : Crompton, Cat No : LSTP-45-CDL or equivalent in Havells/ philips
S&F ceiling rose, 3 phase / PVC / polycarbonate, isolated body complete all as specified directed.
S&F in replacement of sheet metal enclosure distribution board, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
S&F in replacement of MCB, SP, AC, 240 volt of 06 to 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
S&F in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
S&F for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 10 Sqmmx2 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
M&L Sand cushioning to U/G cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches complete all as specified and directed. Note: - Only punned thickness shall be measured.
Supply and laying 50 mm bore galvanised steel tubes with all fittings, light grade laid in trenches for cable protection complete all as specified and directed.
Supplying & laying Fly ash brick laid flat with width equal to the length of brick over cable protection complete all as specified and directed.
S&F exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 300 mm sweep 1400 RPM including suitable louvers and making connection with twisted copper flexibelwire 23/0.076 mm complete all as specified and directed. Make/Model:- Havells Turbo Force SP 1400/ Orient 300 mm Heavy Duty/ Bajaj Heavy Duty Maxx Air
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part I - 2009 and connected to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
Matrubhoomi Construction
M/S KAUSHIK CONSTRUCTION
M/S S S A ASSOCIATES
QUALITY CONSTRUCTIONS CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .