Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC D S 185 186 SECTOR D LDA COLONY KANPUR ROAD LUCKNOW LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.6 L+₹5,071 (0.17%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹34.8 L+₹4.2 L (13.9%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹35.7 L+₹5.1 L (16.8%)Rejected-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L4 | Rejected-AOC L4 | |
| 5 | L5₹40.8 L+₹10.3 L (33.7%)Rejected-AOC PLOT NO 37 BADANPUR OLD SER NO 34658 NEAR SAI BARAT PALACE PAWAN BHUMI SHAKTI NAGAR JABALPUR MADHYA PRADESH 482001 | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-AOC L5 |
Tender Value
₹38.0 L
EMD Value
₹76,040
Closing Date
18 May 2024, 6:00 pmClosed
AGM (E-E)
O/o Airport Director, Kanpur Airport
Operation and routine maintenance of HVAC system including BMS, VRF, Split, Precision AC and water coolers installed at NTB, OTB and CA Cantt at Kanpur Airport for the year 2024-2025
2024_AAI_194038_1
Operation and routine maintenance of HVAC system at Kanpur Airport 2024-25
Open Tender
Electrical Works
Item Rate
312 days
Kanpur Airport
Please refer Tender documents.
18 documents required · 18 mandatory
₹1,180
Yes
₹76,040
Yes
27 Jun 2024
25 Apr 2024
20 May 2024
26 Apr 2024
18 May 2024
26 Apr 2024
26 Apr 2024 - 2 May 2024
Amount
Annual operation of HVAC system ( Consisting of screw type chiller 02 Nos with VFD giving actual capacity 329.6 TR, Cooling Tower 02 Nos 438TR each, various Pumps, AHUs 06 Nos of different capacity, Hot water generator 02 Nos each 225 KW, Split AC, VRV AC system , Precision type AC, Unitary AC, Cabinet AC for Servers, Inline Fans, Air lock Lobby, Air curtains and other system related to Air conditioning etc. by engaging man power per day including Sunday / weekly off/ Holidays etc. for operating the system as required. 1. Supervisor for HVAC & BMS system ----------01 Nos (Highly skilled in General Shift) 2. Technician for HVAC system---------------------02 Nos (Skilled)(01 Nos in each shift) 3. Operator for HVAC system-------------- 02 Nos (Semi skilled) (01 Nos in each shift) 4. Helper for HVAC system-----------------------02 Nos (Unskilled) (01 Nos in each shift) 5. Reliver for 2,3&4 manpower weekly off------01 Nos ( Skilled) Note-(a) Shift timing will be decided by Engineer In charge or Representative as per the site requirement and flight operation.
Comprehensive maintenance and repair including attending preventive & breakdown maintenance of following window/split air conditioner along with their stabilizers of different make and capacities at different locations including interconnecting wiring etc. as required - for a period of one year. (1.5/2 TR split type air conditioner)
Dismantling of 1.5/2.0/3.0/4.0 ton capacity Split/Tower/Cassette type Air Conditioning units including Indoor/Outdoor unit complete as required.
Shifting, installation, testing & Commissioning of 1.5/2.0/3.0/4.0 ton capacity Split/Tower/Cassette type Air Conditioning units including Indoor/Outdoor unit complete as required.
Annual comprehensive Maintenance contract of 4 nos. Industrial type Water cooler cum RO water Purifier of capacity 50/60/80 (Make-Ion Exchange) including all parts & compressor, valves etc. but excluding filters/ membrane complete as required - for a period of one year.
Supply and replacement of following filters/Membrane in fountain-type (make/model: Oasis/P8EBFSLY) / industrial storage type water cooler cum RO water purifier of capacity 50/60/80 (make: Oasis/Ion exchange) installed at different location of Kanpur Airport.
Sediment filter spun 20"
Carbon filter CTO 20"
Carbon filter GAC 20"
Inline Carbon filter
RO membrane 100 GPD (minimum TDS 3000-4000)
RO membrane 100 GPD (minimum TDS 1500) including housing
Sediment filter spun 10"
Carbon filter CTO 10"
Carbon filter GAC 10"
Alkaline filter
Supply of following chemicals required for the proper operation of the chemical dosing kit at HVAC plant.
Chemical for corrosion treatment (MAXTREAT 7015 or equivalent)
Chemical for scale inhivitor (MAXTREAT 7770 or equivalent)
Chemical for corrosion inhibitor + biodisperant (MAXTREAT CL - 5 or equivalent)
Chemical for biocide treatment (MAXTREAT 652 or equivalent)
Chemical for Algaecide treatment (MAXTREAT 616 or equivalent)
Chemical for PH reducer (MAXTREAT 7098 or equivalent)
Supply of Hypochlorite solution with suitable concentration for disinfection and water treatment applications.
Corrosion prevention treatment of brazing joints, U bends and interconnecting copper piping with in the precision AC ODUs and indoor units and VRV outdoor units complete as required.
VRV ODUs 10 / 12 HP
Precision ODUs 4 TR.
Precision indoor unit 4 TR.
Copper piping
M/S COOLING CENTER
V Save Electronics Pvt Ltd
Blue Star Limited
Zamzam Refrigeration and airconditioning
CIS GLOBAL INFRATECH PRIVATE LIMITED
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .