| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC 10 SANJAY HSG SOCIETY RACCA COLONY SHARANPUR ROAD NASHIK 422 002 | NASHIK | MAHARASHTRA | 422002 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹46.3 L+₹2.4 L (5.56%)Rejected-Finance R H NO 14 ADITYA PALACE PATOLE MALE B H SUMAN HOSPITAL JAI BHAWANI ROAD NASIK ROAD 422102 | NASIK | NASHIK | MAHARASHTRA | 422102 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹46.4 L+₹2.5 L (5.68%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹48.3 L+₹4.4 L (10.1%)Rejected-Finance FLAT NO 02 RUTUPARNA APARTMENT PLOT NO 36 S NO 324 2A NEAR G D SAWANT COLLEGE PATHARDI NASIK 422 010 | NASHIK | MAHARASHTRA | 422010 | L4 | Rejected-Finance Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender documents
2023_MES_616769_2
GE/NRC/8606/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Nasik Road
₹90,000
Yes
24 Nov 2023
6 Oct 2023
30 Oct 2023
6 Oct 2023
27 Oct 2023
13 Oct 2023
Amount
M&L for preparation of old decorated plastered or unplastered surfaces including brooming down moulds & efflorescent salt & trading oil & greasy spots and applying one two of white wash on walls.
All as per item No. 1.00 Above but on ceiling.
Demolition of concrete in ground floors and pavings n exc 15cm thickness (below or above ground level).
M&L for 100 mm thick sub-base with cement concrete type D-2, 1:4:8 (40mm graded aggregate).Concreting to be done using mechanical mixer only.
M&L for 100 mm thick concrete flooring with cement concrete type B-2, 1:2:4 (20 mm graded aggregate) over and including provision of pvc diviging strip for joints.complete all as specified in SSR Part-I.Concreting to be done using mechanical mixer only.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;over and including provision of PCC 1:2:4 using 20 mm graded aggregate for edging/sides of footpath/paver as per standard engineering practice and as per direction of engr-in-charge.
Dismantling wrought iron or mild any description such as steel gate, steel frame works, purlins, rafter, railings, balusters and window guard bars and directed by Engr-in-Charge. Note:work is to be executed at any height.
S&F Framed work as in grill, doors or gates of angle or other section with gusset plates, braces, etc, complete, drilled for fixing of steel sheeting or other covering, Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe Grade 290(Gde E-165) complete all as specified and directed by Engr-in-Charge.
S& F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 Grade St-240 complete fabrication and erecting all as specified and as directed. Make: work is to be executed at any height.
Dismantling Plain or corrugated steel sheeting of any gauge,thickness,including Nainital or similar pattern roof coverings complete all as specified and as directed. Note:work is to be executed at any height.
S&F Prepainted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/cladding to wall,fixed with self tapping screw complete all as specified and as directed. Gap between wall face and sheet if any shall be sealed using PCC 1:2:4 type B0 with WPC.quoted rate deems to be inclusive of the same.
S&F Prepainted Galvalume aluminium zinc coating GI based Plain sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/cladding to wall,fixed with self tapping screw complete all as specified and as directed.
M&L for preparation of old painted wooden surfaces of any description,not other wise described,over 10 cm width or girth and applying one coat of synthetic enamel paint over a coat of primer. Note:work is to be executed at any height and situation.
Taking up or down steel tubing and connections 15mm bore including bib taps, stop cock etc. Note: work is to be executed at any height and situation.
Refixing old steel tubing and connections 15mm bore in new or old position (Walls, ceiling, floors, etc.) Note: GI tubing shall be concealed wherever directed by Engr-in-charge. Contractors quotated rates deems to be inclusive of the concealed plumbing.
S&F 15mm bore galvanised steel water tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors. Note: GI tubing shall be concealed wherever directed by Engr-in-charge. Contractors quotated rates deems to be inclusive of the concealed plumbing.
Taking up or down steel tubing and connections 20mm bore. Note: work is to be executed at any height and situation.
Refixing old steel tubing and connections 20mm bore in new or old position (Walls, ceiling, floors, etc.) Note: GI tubing shall be concealed wherever directed by Engr-in-charge. Contractors quotated rates deems to be inclusive of the concealed plumbing.
S&F 20mm bore galvanised steel water tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors. Note: GI tubing shall be concealed wherever directed by Engr-in-charge. Contractors quotated rates deems to be inclusive of the concealed plumbing.
S&F 15mm bore bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repair.
S&F in repair 15 mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
S&F in repairs 15 mm bore stop valves, cast copper alloy, fancy type, chromium plated (angle type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F in repairs 15 mm bore stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union S&Fixed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm
S&F 32mm bore low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm including fittings.
S&F in repairs Brass chromium plated shower rose 125mm size with swivel joint, including fixing to steel pipe or union 15mm bore.
S&F Brass CP wash basin mixer for mixing hot & cold water scrwed down for iron pipe and 15 mm bore fixed in repair.
S&F Brass CP mixer for mixing hot and cold water, screwed down for iron pipe 15mm bore and fixed in repairs.
S&F ball valves, 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) fixed in repairs.
Disconnecting existing tanks exc 250 n exc 500, setting aside (or lowering if required) cleaning and removing all scale dirt,etc from the mouth of circulating pipes etc and hoisting if required,reconnecting and re-fixing in position.
Disconnecting existing tanks exc 500 n exc 1000, setting aside (or lowering if required) cleaning and removing all scale dirt,etc from the mouth of circulating pipes etc and hoisting if required,reconnecting and re-fixing in position.
Dismantling water tanks exc 250 & n exc 500 ltr capacity and removing to store.
S&F Rotational moulded polyethylene water storage(Capacity 500 Ltr) tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debris out of MOD land and rubbish off the premises
M&L for coloured Ceramic tile 7-8 mm thick as in flooring/skirting over and including 15 mm thick screed bed in CM 1:6 for laying floor in any shape/position. Note:Note: size,shade of tile shall be as approved by GE based on manufacturing company catalogue. contractor quotated rate deems to be inclusive of tile of max size i.e. 600mm x 600mm.
M&L for coloured glazed ceramic tile 7-8 mm thick as in dado/wall tiling over and including 10 mm thick backing coat in CM 1:4 in any position /shape/pattern. Note:Note: size,shade and pattern of tile shall be as approved by GE based on manufacturing company catalogue.
M&L for 8-10 mm thick double charged vitrified tile as in flooring,laid in any shape/pattern over and including 15 mm thick screed in CM 1:6 as in floors. Note: size,shade of tile shall be as approved by GE based on manufacturing company catalogue. contractor quotated rate deems to be inclusive of tile of max size i.e. 60cm x 60cm.
M&L for 8-10 mm thick double charged vitrified tile as in skirting,laid in any shape/pattern over and including 10 mm thick backing coat in CM 1:4. Note: skirting shall be of same size and same make as for flooring.
S&F in repair Vitreous China water closet squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests and P/S trap (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding.
S&F in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including flush pipe and brackets complete all as specified and directed.
S&F in repairs Vitreous china premium/ 1st quality wash down water closet wall hung/floor mounted EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket,sheet cover,S or P trap etc. over and including flush pipe complete in all respect all as specified.
S&F in repairs Vitreous China wash basin white, flat back, size 550 X 400mm, including cutting for and pinning in ends of brackets or erecting stand, with and including 32mm waste fitting brass, chromium plated with long screwed shank and fly-nut, flange end bedded in red lead cement, brass chromium plated bottle trap with inlet and outlet screwed for pipe or connections 32mm bore, including necessary packing, union and cap and fixed in repairs.
M&L for Vitreous China urinals, half stall type (back or corner wall type), white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with and including 5 litres PVC automatic flushing cistern, including brackets, flush pipe, CP urinal spreader, grating union, , union and cap and discharge pipe; fixed in repairs.
M&L for PVC (SWR) floor trap(75 mm dia), plain with grating including jointing with solvent cement to mitigate the site requirement to the entire satisfaction of engr-in-charge.
S&F in repairs for Tubular towel rail,brass Chromium plated 20mm dia,D type,60 cm long between flanges complete .
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repairs Sink made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar.
M&L for Granite (of any type) work 20mm thick machine cut, (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like laid over and including 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match.
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations. (Stone slabs so provided shall be not less than 900mm in length)
M&L for Repairing of broken edges of RCC chajjas, roof projections, fins, facia and similar works by dismantling of loose and damaged/ disintegrated portion of edges (cross sectional area not exceeding 150 sqcm) with cement mortar 1:4 or cement concrete 1:1½:3 type A0 and chicken wire mesh with nails (to hold fresh mortar/concrete) including necessary formwork etc. and scaffolding for work upto four storied buildings and finishing the surface by paint to the entire satisfaction of engr-in-charge and match the surface with existing work. Note:work is to be executed for multistorey bldgs.
Plastering on walls in cement mortar 1:4 in patches not exc. 3 Sqm on the buildings upto four storied, including taking down old plastering on walls and curing. Note:for multistorey bldgs and in any situation.
Taking down MS window/ventilators frames/partition frames complete with shutters of any size and any description,making good soffits,jambs,cills etc to receive new windwo/ventilators frame complete all as specified and as directed. Note:work is to be executed at any height and situation.
S&F aluminium (minimum 50 micron powder coated) frame for doors, windows, ventilators/frame for glazing partition with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F aluminium (minimum 50 micron powder coated) door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified.
S&F aluminium (minimum 50 micron powder coated) window and ventilator shutters, side hung/sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays/tower bolt 150mm long (1 No.) hinges type B-21, 100mm long (2 Nos.), suitable handle (1 No.), rollers, grip etc. complete all as specified.
S&F 3.0 mm thick sheet glass, ordinary quality and glazing with silicon gel in square n exc 0.5sqm in each pane.
S&F 5.50 mm thick sheet glass, ordinary quality and glazing with silicon gel in square exc 0.5s qm in each pane.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed.
Preparing new untreated steel or iron surfaces over 10cm width or girth and and two coats of synthetic enamel paint over and including a coat of red oxide.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) n exc 1.5 sqm each and making good the jambs, soffits of lintels etc. after fixing of new chowkat or frame to match the existing surface.
Solid PVC door frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet reinforced with M.S. square tube, supplying & fixing in opening as per specification and drawing.
Factory made solid PVC moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick moulded prelam PVC Sheet on the front face and 2 mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each and making good the jambs, soffits of lintels etc. after fixing of new chowkat or frame to match the existing surface.
M&L for 2nd class hardwood for Plain,solid,straight chowkhats and frames,framed rebated on the solid,rounded or chamfered,put together with glue pinned at,complete all as specified and directed. Note:sample shall be produced by contractory compulsory for authencity of wood species before procurement.
Taking down shutters of any description exc 1 Sqm and n. exc 2 Sqm each.
Taking down shutters of any description exc 2 Sqm each.
M&L for 35mm thick second class hard, wood factory, made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.
S&F factory made plain framed paneled shutters 35mm thick of 2nd class hard wood (any number of panels ) with panels of timber flat on both sides feather edges or panel of 9mm BWP commercial ply over 12mm thick veneered particle board with commercial face veneers fixed to chowkat. The size of rail and stile as per IS: 1003 (Part-1), kiln seasoned and chemically pressure treated complete all as specified and directed.
Preparing new wood or wood based surfaces over 10cm width or girth and two coats of synthetic enamel paint over and including a coat of pink primer.
S&F 100mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21.
S&F 200mm size aluminium anodised, barrel tower bolts of extruded section and fixed.
S&F 300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.
S&F extruded aluminium alloy handles,125 mm size, fabricated type, anodised.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc.
M&L for brick work with fly ash bricks straight or curved on plan exc 6 m mean radius built in CM 1:6.incl raking out joints on both faces of wall. Curing as per standard engineering practices.
Taking down completely cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L for Rendering 10mm thick in cement mortar 1:6 on wall/ceiling surfaces finished fair and even.
M&L for rendering 15 mm thick in cement mortar 1:4 on brick wall surfaces/concrete surfaces finished fair and even.
M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling surfaces finished fair and even.
M&L for preparation of newly plastered surfaces of wall /ceiling and applying two coats of cement based paint over a coat of exterior primer.
M&L for applying two coats of exterior emulsion paint on wall/ceiling surfaces including preparation. Note:for multistorey bldgs work to be executed using ladder/sccaffolding only.
M&L for preparation of plastered surfaces of wall/ceiling and Distempering with 1st quality(as per manufacturers catalogue) acrylic distemper(ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats as directed by engr-in-charge. Note:make as specified in CA.
M&L for special treatment to sunken portion with 10mm thick plaster in CM 1:4 by using Ditachment DM 1% by weight of cement and surface made smooth after curing period two coat of Ditachment DS shall be applied @2.50 Kg/Sm. The paste like consistancy like is made by using 2.5 Kg of Ditachment DS powder in one litre of admixture (The admixture is made by dissolving 1 part by volume of Nafufill SBR & 4 part by volume of water). After 3 days curing, testing shall be done by flooding for 24 hours. Finally protective plaster coat of 10mm thick in CM 1:4 shall done by using Putz Ditachment 1% by weight of cement over layer of Detachment DS. All joints of CI Pipe, Nahani trap, WC connection etc. shall be filled by mixture of cement, fine sand and 10% Nafufill SBR by weight of cement 32mm dia 450mm long GI Spout light grade shall be provided in all sunken slabs to drain off water. Note: Sunken treatment shall be completed within 7 days after handing over of site for sunken for each bldg in all respect including all fittings/tiling etc under normal circumstances. For delay beyond 7 day, penalty shall be charged @ Rs 1000/day and shall be recovered from contractors RAR/FB as decided by GE.work to be executed at any height and situation on most urgent basis.
M&L for fixing in repair 25 mm matt finish Stainless steel curtain rod best quality as approved by Engr-in-charge
M&L for fixing in repair Stainless steel socket bracket with bore of 25mm for dead end of curtain rod .
M&L for fixing in repair Stainless steel ornamental piece with bore dia of 25 mm for free end of curtain rod .
M&L for fixing in repair Stainless steel projecting bracket to support curtain rod of size 25mm.
M&L for 1.5 mm thk (in two coats)wall care putty on walls including preparation of surfaces to the entire satisfaction of ground executives.
M&L for 1.5 mm thk(in two coats) wall care putty on ceiling incl preparation of surfaces to the entire satisfaction of executives.
M&L for Complete removal of existing treatment,cleaning moss,dirt,greasy spots,washing and applying two coats of acylic distemper oil emulsion white or tinted(incl multiple pattern/shade in one bldg) on walls/ceiling incl preparation of surfaces,sealing holes and cracks of any depth/width with crack sealing compound using gun.Preparation of surfaces shall be done in accordance to the clause No 15.14.2.1 of SSR Part-I(2009).
All as per item No. 94.00 Above but on ceilling
M&L for preparation of old plastered surfaces of wall/ceiling by scrapping,removing nails,making good holes/cracks of any width/depth using crack sealing compound using gun and applying a coat of distemper oil emulsion(premium quality as per manufacturer catalogue) on wall/ceiling surfaces.
M&L for applying two coats of interior primer on wall/ceiling surfaces incl preparation of suraces to the entire satisfaction of ground executives.
M&L for applying one coat of interior primer on wall/ceiling surfaces incl preparation of suraces to the entire satisfaction of ground executives.
M&L for preparation of old painted steel surfaces of any description,over 10 cm in width or girth,not other wise described and applying one coat of synthetic enamel paint of tint as directed by engr-in-charge.
M&L for preparation of old surfaces of walls/ceilings by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots; washing,removing nails,removing vegetation growth of any size and penetration to the entire satisfaction of ground executives. Sealing holes,cracks of any width/depth by waterproof crack sealing compound using gun and applying one coat of exterior emulsion paint on walls/ceiling Note: work is to be executed at any height and situation.For multistorey bldgs painting is to be done using ladder/sccaffolding only.
M&L for complete removal of existing treatment to wall/ ceiling surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots;washing, removing nails, sealing holes,cracks of any depth/width by sealing with waterproof crack sealing compound using gun and applying two coat of exterior emulsion paint on walls and ceilling surfaces. Note:work is to be executed at any height and situation.For multistorey bldgs painting is to be done using ladder/sccaffolding only.
M&L for applying two coats of exterior primer applied over new/old prepared wall/ceiling surfaces including preparation of surfaces to the entire satisfaction of ground executives.
M&L for applying one coat of exterior primer on wall/ceiling surfaces including preparation of surfaces to the entire satisfaction of ground executives.
Demolition of concrete (unreinforced) of any description and in any position not otherwise secifically provided for.
M&L for PCC 1:4:8 type D-2 as in foundation filling and mass concrete or sub bases to floor.
Taking down AC rain water pipes(any size or pattern) including all fittings,head shoes,bends,swan neck etc.
S&F PVC (SWR) pipes110 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors/walls including pvc clamps and stays.
S&F PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors.
Taking down carefully copper/aluminium point wiring complete (light,fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets main switches, DB removing materials to store and making good to disturb surfaces of wall/floors etc as specified & directed.
M&L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.2mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for One light point/ fan point controlled by one, one way swtich. Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
All as per ser item No. 110.00 herein before but One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified.
All as per ser item No. 110.00 herein before but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes.
All as per ser item No. 110.00 here in before but on independent board.
All as per ser item No. 110.00 here in before but one light point controlled by 2 way switches.
All as per ser item No. 109.00 here in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent.
M&L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC casing and caping (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.2mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for One light point and one fan point controlled by one, one way swtich. Note:- Unit rate include for cutting chases for sinking for boxes and making good to wall ,floors etc.
All as per ser item No. 116.00 here in before but One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified.
All as per ser item No. 116.00 here in before but on independent board.
All as per ser item No. 116.00 here in before but one light point controlled by 2 way switches.
All as per ser item No. 116.00 here in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent.
All as per ser item No. 116.00 herein before but with 2.5 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including Fibre insulation boards, treated on one face only of adequate size for mounting purposes.
Supply and fixing in replacement of switch piano flush button 5 Amp single pole one way 230 volts white finish all as specified & directed.
Supply and fixing in replacement of socket outlet flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed.
Supply and fixing in replacement of switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed.
Supply and fixing in replacement of switch socket combination multipurpose flush type 2 in 1 type (3 and 3 pin) 5/15 Amps, 230V, AC.
Supply and fix in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with invertor LED bulb 9 watt complete all as specified and directed
Supply and fix in replacement ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish.
Supply and fixing in replacement of bell push, flush type, 5 Amp single pole, 230 volts white finish all as specified & directed.
Supply and fixing in replacement of switch piano flush button 5 Amp single pole 2 way 230 volts white finish all as specified & directed.
M&L for replacement and connecting up fan regulator electronic on existing phenolic laminated sheet dimmer type 230 volts, 450 watts suitable for ceiling fan 1200/1400mm sweep.
Supply and fix in replacement Energy efficient LED tube & batten Luminaire, 20 Watt, 4 feet long complete with prewired using 1.5 Sqmm FRLS PVC insulated (Unsheathed) 3 core copper conductor cable, 1100V grade complete all as specified and directed.
Supply and fixing in replacement of LED 150 Watt highbay optica heavy duty luminaires with engineering grade diffuser for added protection, secondary optics, suitable for industrial lighting applications, with IP 65 incl connecting up with three core flexible copper conductor cable of suitable size from ceiling rose.
Supply and fixing in replacement of LED 10 Watt inverter LED batten with rod complete with lithium ion battery with charging time 8-10 hours and backup time upto 4 hours mounted on square box of suitable size connecting up with three core flexible copper conductor cable of suitable size from ceiling rose.
Fixing only in replacement of LED tube light fittings 18/20 watt complete with connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to tube light fittings complete all as specified and directed by Engineer-in-Charge. Note:- LED tube light 18 /20watt will be issued to contractor free for fixing only.
Supply and fixing in replacement of buzzer, AC, 230 volts, single phase complete all as specified and directed.
Supply and fixing in replacement of bell, AC, 230 volts, single phase complete all as specified and directed.
Supply and fixing in replacement of bell multi music type AC, 230 volts, single phase complete all as specified and directed.
Supply and fixing in replacement of sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified.
Supply and fixing in replacement of sheet metal enclosures with plug socket triple pole and earth with three pin and earth plug with socket 415 volts complete with one triple pole MCB of 63 Amps (TP) complete all as specified.
Supply and fixing in replacement of submain wiring with three single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 6 Sqmm drawn through in and including steel conduit including 6 Sqmm 1100Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed.
Supply and fixing in replacement of submain wirng with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including PVC heavy duty surface casing caping including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed.
Supply and fixing in replacement of submain wiring with three single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 4 Sqmm drawn through in and including steel conduit including 4 Sqmm 1100Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note for Srl item No 132.00 to 134.00 herein before :- (i) Three runs of cables and one run of continuous earting cable drawn in steel conduit will be measured as one length of sub main. (ii) Steel conduit and its accessories is deem to be included in this item rates. (iii) Unit rate include for cutting chases for sinking for boxes and making good to wall, floors etc.
Supply and fixing in replacement of submain wirng with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 2.5 Sqmm drawn through in and including PVC heavy duty surface casing caping including 2.5 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note for Srl item No 133.00 & 135.00 herein before :- (i) Two runs of cables and one run of continuous earting cable drawn in casing and caping will be measured as one length of sub main. (ii) PVC casing caping and its accessories is deem to be included in this item rates. (iii) Unit rate include for cutting chases for sinking for boxes and making good to wall, floors etc.
Supply only in replacement of LED outdoor drivers, suitable for 150 watt street light fitting all as specified and directed by Enginner-in-Charge.
Supply and fixing in replacement sheet metal enclosure (factory made), TPN Vertical Distribution Boards (MCCB Incomer) IP43 protection Double Door : Plain 4 way with 200 Amps rated busbar all as specified and directed.
Supply and fixing in replacement sheet metal enclosure (factory made), TPN Vertical Distribution Boards (MCCB Incomer) IP43 protection Double Door : Plain 8 way with 200 Amps rated busbar all as specified and directed.
Supply and fix in replacement distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 415 volts, 200 Amp rated bus bar with front openable cover suitable for TP & N 4 ways all as specified & directed.
Supply and fix in replacement distribution board sheet metal enlosure factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 2 ways all as specified & directed.
Supply and fix in replacement distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 4 ways all as specified & directed.
Supply and fix in replacement distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 8 ways all as specified & directed.
Supply and fix in replacement distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 12 ways all as specified & directed.
Supply and fixing in replacement 4 Pole MCCB 125 Amp, 50 Hz, 415 V, with adjustable thermal & adjustable magnetic setting, breaking capacity 25 KA.
Supply and fix in replacement MCCB 63 Amp TP, 415 volts 16KA.
Supply and fix in replacement MCB FP 63 Amp, 415 Volts, 50 Hz with 10 KA.
Supply and fix in replacement MCB TP 40 Amp, 415 Volts, 50 Hz with 10 KA.
Supply and Fixing in replacement of MCB DP/SPN 6-32 Amps, 230 Volts, 50 Hz with 10 KA.
Supply and Fixing in replacement of MCB SP 6-32 Amps, 230 Volts, 50 Hz with 10 KA.
M&L for replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion.
Supply and fixing in replacement of 30 Watt Invertor LED street light fitting luminaire, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. , including coneecting up with 2/3 core flexible coppper conductor cable , compete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Invertor LED luminaire 600mm x 600mm, 36 watt, 220 volts AC recessed/ surface type fittings, epoxy powder coated CRCA sheet housing with electronic driver, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
NOTE: - AMOUNT OF SCHEDULE OF CREDIT RS. 82,432.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
SVT ENGINEERS AND CONTRACTOR.
JEET CONSTRUCTIONS CO.
Abhiraj Enterprises
Bidder Name
M/S SAMEER SUBHASH PATANI
SVT ENGINEERS AND CONTRACTOR.
JEET CONSTRUCTIONS CO.
Abhiraj Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .