| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹22.7 LAccepted-AOC | 1st | Accepted-AOC The lowest bidder M/s Vinayak Trading House has been accepted pl. | |
| 2 | 2nd₹29.3 L+₹6.0 L (25.8%)Rejected-Finance 148 SANGHI STREET MHOW MP 453441 | MHOW | INDORE | MP | 453441 | 2nd | Rejected-Finance L2 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Nov 2021, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
MAINTENANCE AND REPAIR OF SOLAR WATER HEATING SYSTEM AND ALLIED WORKS UNDER GE AWC MHOW.
2021_MES_481533_1
8536 GE(AWC) /MHOW / OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AWC MHOW
All as per Tender Documents and NIT.
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹50,000
Yes
20 Dec 2021
13 Oct 2021
16 Nov 2021
13 Oct 2021
15 Nov 2021
30 Oct 2021
Amount
Labour only for for servicing of Solar water heating systems of any types Flat plate collectors type or Evacuated tube collector type of capacity upto 400 LPD installed at multistorey building (upto G+6) by removing carefully the outer transperent glass plate, removing the collecter plate and tubings /evacuated glass tubings , descaling with standard bio-acid treatment to ensure free flow of water by thermo cyphen system reassembling the same duly provided with inlet and oulet water connections,stopping the leackage by replacing the old unserviceable CPVC pipe/tee/bend/broken glass tubes etc. complete all as specified and directed. Note 1: Items incorporated such as Distilled water, CPVC pipe /glass tubes,CPVC acessories etc will be measured and paid saperately in respective item.
Supply and fixing in replacement of GI coupling union 15 mm bore, ISI marked complete.
S&F in replacement of Chromium plated ,Concealed stop cock short body, cast copper alloy, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle, screwed externally both ends for unions etc.
M & L in Replacement of Gl tubing medium grade 15mm bore with fitting , fixed to walls and ceilings or laid in floors complete all as specified and directed
Supply and fixing in replacement of 16 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings and fixing works and testing of pipe line test for solvent cement joints and adhesive joints and testing of all materials shall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282 including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing in replacement of 20 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings and fixing works and testing of pipe line test for solvent cement joints and adhesive joints and testing of all materials shall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282 including making good the disturbed surfaces complete all as specified and directed.
M&L for replacing Flat plate collector asssembly of capacity 350 LPD by dismantling the the outer transparent glass plate, removing the collecter plate and tubings , replacing it with highly heat co-efficient collector plate and evacuated copper tubings , refixing the outer transperent glass cover providing water connections complete incl testing all as specifed and directed.
M&L for replacing Flat plate collector asssembly of capacity 400 LPD by dismantling the the outer transparent glass plate, removing the collecter plate and tubings , replacing it with highly heat co-efficient collector plate and evacuated copper tubings , refixing the outer transperent glass cover providing water connections complete incl testing all as specifed and directed.
Supply only Distilled water in the Solar water Heating systems at different location and distilled water will be filled in existing distilled water pot connected on solar tank complete all as specified and directed at site Note :- Distilled water will be supplied in sealed containers.
Supply and fixing in replacement of heating element thread type 3.0 KW and fixed at solar water heater tank complete with 9" long thermostate variable type complete with ISI Mark.As approved by GE
Supply and fixing thermostat suitable for solar water heater heating element complete all as specified and as directed
Supply and fxing in replacement of solar collector plate touch end glass size 1 x 4 M and 4 mm thick fixed on solar collector complete all as site requirement and directed by Engr-in-charge.
S & F in replacement of 300 LPD Puf insulated stainless steel hot water storage tank for 300 LPD solar water heater storage tank material 316 grade stainless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge.
S & F in replacement of 100 LPD Puf insulated stainless steel hot water storage tank for 100 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge.
S&F in replacement of anti rust ring for 1500 x 47 mm size special grade borocilicate glass tube complete all as specified and directed,
S&F silicon ring for 1500 x 47 mm size Tata BP special grade borocilivate glass tube complete all as specified and directed,
S&F plastic tube holder for 1500 x 47 mm size Tata BP special grade borocilivate glass tube complete all as specified and directed,
S&F in replacement of brass elbow suitable for CPVC pipe line of size 16 mm complete jointing etc all as specified and directed.
S&F in replacement of brass elbow suitable for CPVC pipe line of size 20 mm complete jointing etc all as specified and directed.
S&F in replacement of brass Tee suitable for CPVC pipe line of size 16mm complete jointing etc all as specified and directed.
S&F brass in replacement of Tee suitable for CPVC pipe line of size 20 mm complete jointing etc all as specified and directed.
S&F in replacement of Female brass threaded adopter suitable for CPVC pipe line of size 16mm complete jointing etc all as specified and directed.
S&F in replacement of Female brass threaded adopter suitable for CPVC pipe line of size 20mm complete jointing etc all as specified and directed.
Supply and fixing composite pressure pipe of size 32 mm inner dia and 40 mm outer dia including necessary connection and required accessories such as elbows,tees, reducers, couplers, short pieces,connectors etc of leading IS make complete all as specified and directed by Engr-in-Charge.
S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 ltrs complete all as directed at site.
S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 ltrs complete all as directed at site.
M&L for making provision to fix auxillary heating system (electric) in 300/350/400 LPD solar water heater (FPC/EVTC type) with BSP 32mm as per IS standard . supply voltage 230 volt AC single phase incl provision of electric heater 03 KW capacity along with thermostat with thermo control of max 65 deg C and length 200 mm complete incl addn/altration in hot water collector tank such as drilling,welding threading if any complete incl all connected electric/electronic accessories incl Testing after completion all as specified and directed. Note 1: submain wiring for 230V supply icl connected DBs and controls will be measured and paid saperately in respective item.
S&F VTPN DB, 6way, IP-43, IK 09, double door type with metal door, suitable for fixing upto 3 pole 160 Amp MCCBs as incomer and SP/TP MCB/Isolator as outgoing 6 way double door including taking down, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
Deign, Fabricate, Supply, Installing, Testing and Commissioning of Electricaly control panel of cubical construction, Wall mounting type with 400 amps rated copper bus bar , fabricated out of 2.0 mm thick CRCA sheet, with hinged lockable doors, inter connection, having switchgears and accessories mounting and internal wiring, earth terminal, numbering etc, complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. including the fwg accessories AC supply. (a) 250 Amps 4P MCCB 25 kA as incommer -01 nos (b) MCCB 63 Amps 4 pole 16 kA with termal magnetic release(out going)--01 Nos (Ics=100% Ics) (c) MCB TP 63 Amps ,16 KA -04 Nos (d) MCB SPN 32 Amps- 6 Nos (e) MCB SP 6 to 32 Amps- 12 (f) Digital volt meter-01 (g) Digital Ammeter-01 Nos (g) Space for Change over 160 Amps 4 pole- 01 Nos. (h) Set of 3 phase indicating lamp.-01 Set
S&F MCCB 3 pole 63 Amps ,415 V 125 A Hz with rupturing capacity 25KA (Ics=100% Ics)
S&F MCCB 4 pole 100 Amps breaking capacity 25 KA, Ics = 100% Icu including spreader link & taking down complete all as specified and directed. Including mounting box made of GI sheet 2.15 mm thick factory made for fixing MCCB complete with neutral & earth link, cable glands.
S&F MCB SP 6 to 32 Amp, 10 kA breaking capacity, 240V 'C' curve complete all as specified and as directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core through RCC duct of upto G+6 building by proper saddling or in trenches / under PCC incl making good of surface with PCC/ cementing with proper cable protection incl connecting to existing LT panel board in silt and VTPN DBs near lift machine room complete all as directed at site
S&F MCCB 3 pole 100 Amps breaking capacity 25 KA, Ics = 100% Icu complete incl fixing in existing panel board by modification of bus bar and MS panel frame , connecting copper cable of adequate size with proper lugs/themble as incommer and out going connected to XLPE cable as out going all as specified and directed.
M&L for Tubes, 'light grade,galvanised, with all fitting of size 50 mm laid in trenches or fixed on wll with saddles for cale protection specified and directed.
Sub main wiring with 2 single core,6 Sqmm FRLS, PVC insulated PVC unsheathed stranded FR LSH copper conductor cable in and including PVC surface conduit of earth wire with 1 x 6.0 Sq mm copper cable fixed along with the sub main in PVC conduit on wall /RCC and connecting to earth dolly complete including taking down old sub main wiring all as specified and directed.
M&L for Tubes, 'light grade,galvanised, with all fitting of size 40 mm ;laid in trenches or fixed in wll with saddles for cale protection incl bending and cutting to required length all as specified and directed.
M&L for replacing brocken PCC pedestrials of Anglr Iron frame of solar water heaters / damaged with necessary form work , finishing with cement mortar as per standard use , removing malba making good and cleaning the surfaces complete incl distumbering all as specified and directed
M&L for repair/replacement of Angle Iron support by removing the old/rusted Angle iron frame work by proper dismantlig of the entire Solar system, removing all electrical connections , welding , grinding complete all as specified and directed .
M&L for painting of Angle Iron support of solar water heating system of 300/35/100 LPD capacity by removing old /rusted painting with sand paper, providing two coat of red oxide primer after surface preparation, and painting with metallic paint of approved colour all as specified and directed.
Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified.
M/S Ashish Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .