Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAdmitted-Finance | ₹3.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.2 Cr+₹3.4 L (1.07%)Admitted-Finance | ₹3.2 Cr+₹3.4 L (1.07%) | L2 | Admitted-Finance |
| 3 | L3₹3.2 Cr+₹3.8 L (1.20%)Admitted-Finance | ₹3.2 Cr+₹3.8 L (1.20%) | L3 | Admitted-Finance |
| 4 | L4₹3.2 Cr+₹7.8 L (2.46%)Admitted-Finance SHOP NO 5 BAL VIHAR NEAR SAJJAD NURSING HOME BHOPAL | BHOPAL | BHOPAL | MADHYA PRADESH | ₹3.2 Cr+₹7.8 L (2.46%) | L4 | Admitted-Finance |
| 5 | L5₹3.4 Cr+₹27.3 L (8.62%)Admitted-Finance | ₹3.4 Cr+₹27.3 L (8.62%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MAKEWELL ENTERPRISES L4 | divyashree construction L1 | sanjay constructions L3 | HARSHIT INFRASTRUCTURE L5 | IMPERIOUS ELECTRO AND INFRATECH PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00Upgradation and Maintenance works for Developement of Urban Health and Wellness Center and Polyclinics in Area Under Bhopal Municipal Corporation, Zone 01 to 19 | ||||||||
| 1.01 | Openable single rebate window | 40 | SQM | 4,800 ₹1,92,000 Lowest | 5,042 ₹2,01,680 | 5,052 ₹2,02,080 | 5,000 ₹2,00,000 | 5,000 ₹2,00,000 |
| 1.02 | Providing and fixing of factory make fixed louvers fabricated from roll
formed sections made of galvanized pre-painted steel with epoxy primer
of 5-7 microns thick, finish painted with a polyester paint of 12-16
microns thick and back coated with alkyd backer 5-7 microns thick or
powder coated with pure polyester powder up to 50-60 microns thick,
colour coated/powder coated (base steel as per IS 513 ‘D’ quality,
galvanized as per IS 277 with zinc of 120 grams/Sqm) section for
external frame 33 x 58 x0.58mm, glass holding flanges made of
polypropylene, sections are to be cut to length, miter joined with
corner bracket. The above frames should be fixed to the concrete/masonry
walls by means of self- expanding screws. Including filling the gap upto
5 mm depth and 5 mm width in between steel frame and adjacent RCC/
Brick/ Stone work by providing weather silicon sealant over backer rod
of approved quality as per architectural drawings and direction of
Engineer-in- charge complete. (glazing shall be paid separately as per
SOR rate)Roll formed steel window- – fixed ventilator | 14 | SQM | 3,512 ₹49,168 Lowest | 3,812 ₹53,368 | 3,812 ₹53,368 | 3,800 ₹53,200 | 3,800 ₹53,200 |
| 1.03 | of approved brand and manufacture to give an even shade :Two or more
coats on new work | 1,050 | SQM | 55 ₹57,750 Lowest | 59 ₹61,950 | 59 ₹61,950 | 57 ₹59,850 | 59 ₹61,950 |
| 1.04 | Supplying and fixing PVC conduit ISI marked along with the accessories
in concealed system etc. as required PVC . Conduit 25 mm (HMS) | 1,800 | RM | 41 ₹73,800 Lowest | 43.68 ₹78,624 | 43 ₹77,400 | 42 ₹75,600 | 43 ₹77,400 |
| 1.05 | Supplying and fixing of approved make step type electronic Fan regulator
including connection etc. as required on existing board 100 Watt (socket
type) | 120 | EA | 416 ₹49,920 Lowest | 436 ₹52,320 | 436 ₹52,320 | 430 ₹51,600 | 430 ₹51,600 |
| 1.06 | Supply and fixing Led tube rod comprising of LED tube with non integral
/ integral driver, 6500K color temp having 40000 burning hrs life with
minimum @ L 70, system lumen output should be minimum with efficacy >
80 lm/W. LED driver PF 0.95 & THD < 20%. The colour rendering index of
LED light should be more than 70. Submission LM 80-08 Form LED Source
Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer
mandatory i/c connection wire, testing etc. to complete the job. 2 Yrs
Guarantee certificate from manufacturer.Tube light LED 1x 20/22 Watt
Integral i/c Batten aluminium Body, PC Diffuser | 150 | EA | 840 ₹1,26,000 Lowest | 875 ₹1,31,250 | 875 ₹1,31,250 | 870 ₹1,30,500 | 870 ₹1,30,500 |
| 1.07 | Supplying, Fixing in Position LED lamp of approved make25/ 27 Watt 250
volt | 150 | EA | 650 ₹97,500 Lowest | 672 ₹1,00,800 | 672 ₹1,00,800 | 670 ₹1,00,500 | 672 ₹1,00,800 |
| 1.08 | Supplying and fixing of approved makemodular type G.I. metal box 1.2mm
minimum thick and depth 50mm for singlerow boxes and 60mm depth for
two/three
row boxes earth terminal stud with nut and
washer with modular base and cover plate
including fixing in concealed etc. as
required for: 6 Module metal box | 45 | EA | 170 ₹7,650 Lowest | 193 ₹8,685 | 193 ₹8,685 | 190 ₹8,550 | 193 ₹8,685 |
| 1.09 | Supplying and fixing of approved makemodular type G.I. metal box 1.2mm
minimum thick and depth 50mm for singlerow boxes and 60mm depth for
two/three
row boxes earth terminal stud with nut and
washer with modular base and cover plate
including fixing in concealed etc. as
required for: 8/9 Module metal box | 45 | EA | 232 ₹10,440 Lowest | 244 ₹10,980 | 244 ₹10,980 | 240 ₹10,800 | 244 ₹10,980 |
Tender Value
₹3.5 Cr
EMD Value
₹1.8 L
Closing Date
4 Jul 2022, 5:30 pmClosed
P K JAIN
NEAR SMART CITY OFFICE TATPAR PETROL PUMP, ENGINEERING HEAD OFFICE BMC BHOPAL
UPGRADATION AND MAINTENANCE WORKS(EMPANELMENT BASIS) FOR DEVELOPEMENT OF URBAN HEALTH AND WELLNESS CENTER AND POLYCLINICS IN AREA UNDER BHOPAL MUNICIPAL CORPORATION, ZONE 01 TO 19
2022_UAD_208906_1
2020207779
Open Tender
Civil Works - Buildings
Percentage
365 days
BHOPAL MUNICIPAL CORPORATION, ZONE 01 TO 19
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹15,000
₹1.8 L
8 Aug 2022
2 Jun 2022
5 Jul 2022
2 Jun 2022
4 Jul 2022
2 Jun 2022
Amount
Upgradation and Maintenance works for Developement of Urban Health and Wellness Center and Polyclinics in Area Under Bhopal Municipal Corporation, Zone 01 to 19
Openable single rebate window
Providing and fixing of factory make fixed louvers fabricated from roll formed sections made of galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, colour coated/powder coated (base steel as per IS 513 ‘D’ quality, galvanized as per IS 277 with zinc of 120 grams/Sqm) section for external frame 33 x 58 x0.58mm, glass holding flanges made of polypropylene, sections are to be cut to length, miter joined with corner bracket. The above frames should be fixed to the concrete/masonry walls by means of self- expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. (glazing shall be paid separately as per SOR rate)Roll formed steel window- – fixed ventilator
of approved brand and manufacture to give an even shade :Two or more coats on new work
Supplying and fixing PVC conduit ISI marked along with the accessories in concealed system etc. as required PVC . Conduit 25 mm (HMS)
Supplying and fixing of approved make step type electronic Fan regulator including connection etc. as required on existing board 100 Watt (socket type)
Supply and fixing Led tube rod comprising of LED tube with non integral / integral driver, 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy > 80 lm/W. LED driver PF 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer mandatory i/c connection wire, testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer.Tube light LED 1x 20/22 Watt Integral i/c Batten aluminium Body, PC Diffuser
Supplying, Fixing in Position LED lamp of approved make25/ 27 Watt 250 volt
Supplying and fixing of approved makemodular type G.I. metal box 1.2mm minimum thick and depth 50mm for singlerow boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for: 6 Module metal box
Supplying and fixing of approved makemodular type G.I. metal box 1.2mm minimum thick and depth 50mm for singlerow boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for: 8/9 Module metal box
Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal - magnetic release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2 ; MCCB 25kA current rating - 63 to100Amp & adjustable overload setting 80% -100% of In, adjustable short circuit setting 6-10 In 3 Pole
Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutralbar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as perspecification (exclusive of M.C.B./ MCCB/RCBOs) 63Amp/100Amp, 3P/4P enclosure
Bidder Name
Amount
MAKEWELL ENTERPRISES(GSTN-23AFUPA0702J1ZT)
divyashree construction(GSTN-23EMOPS7423D1ZV)
sanjay constructions(GSTN-23ADEFS6958C2Z0)
HARSHIT INFRASTRUCTURE(GSTN-NA)
IMPERIOUS ELECTRO AND INFRATECH PRIVATE LIMITED(GSTN-NA)
HARSHIT INFRASTRUCTURE
IMPERIOUS ELECTRO AND INFRATECH PRIVATE LIMITED
sanjay constructions
divyashree construction
IMPERIOUS ELECTRO AND INFRATECH PRIVATE LIMITED
sanjay constructions
MAKEWELL ENTERPRISES
HARSHIT INFRASTRUCTURE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.03 MB
tenderdocument112.pdf
Tender Documents • 0.39 MB
2020207779.pdf
Tender Documents • 0.16 MB
BOQ_244994.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .