Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC | ₹4.5 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹4.5 Cr+₹10,000 (0.02%)Rejected-AOC | ₹4.5 Cr+₹10,000 (0.02%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non-Responsive |
Tender Value
₹4.5 Cr
EMD Value
₹9.0 L
Closing Date
26 Nov 2024, 2:00 pmClosed
Spl. CE, PWD(Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD(Bldg), Assam, Chandmari, Ghy-3
Remodelling of GAD Building at Panbazar to accommodate CJM Court, Kamrup(M), Guwahati-01
2024_PWBNH_40258_1
CE/TECH-V/10/2024/12 Dated Guwahati the, 30th Oct, 2024
Open Tender
Civil Works - Building
Item Rate
180 days
Guwahati
Please refer Tender documents.
5 documents required · 5 mandatory
₹9,023
₹9.0 L
Yes
1 Feb 2025
8 Nov 2024
26 Nov 2024
8 Nov 2024
26 Nov 2024
13 Nov 2024
Amount
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). 18 mm thick
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws
Providing and fixing bright finished brass butt hinges with necessar screws etc. complete : (9.72.1) 125x85x5.5 mm (heavy type)
100x85x5.5 mm (heavy type)
75x65x4 mm (heavy type)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (9.74.4) 100x10 mm
Providing and fixing bright finished brass door latch with necessary screws etc. complete : (9.75.1)300x16x5 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. (9.79.1 ) 40 mm
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with adjustable lugs with split end tail to each jamb
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm
Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 fine sand)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For Fixed Portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing toilet paper holder. C.P. brass
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :(17.10.1)Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729
75mm diameter Sand cast iron S&S pipe as per IS: 1729
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia pipes
25 mm nominal dia pipes
32 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Exposed Pipe 25 mm nominal dia pipes
40 mm nominal dia pipes
50 mm nominal dia pipes
Providing and fixing gun metal gate valve with C.I wheel of approved quality (screwed end) 25 mm nominal bore
32 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal Work- Exposed on walls 32 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work 32 mm dia pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 250mm dia SW pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :(2.10.1)All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Trees Plant
Shrubs Plant
Hedge Plant /Ground cover
Providing and Displaying Marigold(Tagetes) inca hybrid different colour having 30 cm and above ht., with 6 to 8 flowers in bloom & blooming condition, well developed pot should be fully covered with fresh and healthy, foliage and flowers in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring,Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, PeruvianaOdissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required(1.7.1)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(1.17.6)6 x 1.5 sq. mm
9 x 1.5 sq. mm
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying & fixing of 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
(1.24.4 +1.24.3 + 1.27.4)Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 amps modular socket outlet and 1 No. 16 amps modular switch, connection etc. as required. (UPS Points ).
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top,alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top,alongwith 20 amps "C" curve, TP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (For ckt/submain wiring extra) 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
TV antenna socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.(1.27.1)1 or 2 Module (75mm X 75mm)
1.27.3 4 Module (125mmX75mm)
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required
Supplying and drawing of UTP 4 pair CAT 6A LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.1.53.1 1 run of cable
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (For tel./ TV / Data wiring) 25 mm
Supplying, Installation, testing and commissioning of following sizes of 0.5 mm dia annealed tinned copper conductor PVC insulated and PVC sheathed unarmoured telephone cable on surface/ existing cable tray complete as required. 20 Pair
Supplying and fixing modular type Information Outlet RJ -45, CAT 6 Data , front plate and suitable size metal box on surface or in recess including connections etc.complete as required.
Supplying and drawing co-axial TV cable following grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. RG-11
Supplying, erection, testing and commissioning of following tap off / splitter as per specification in 1.6 mm thick CRCA sheet steel enclosure for CATV system. 4 Way splitter box
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 +12), Double door
6 way (4 +18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required 12 way (4+36), Double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (2.13.1) 40 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply, assembly and laying of under floor trunking made out of 1.6mm thick GI sheet complete with jointing sleeve, horizontal bends, floor junction box, vertical bends, level adjustment components and closer, vertical elbow, covers, access outlet. etc. complete with all other accessories under floor installation including cutting and chasing the floor/ or on surface, making good the same, placing in position and cleaning from inside complete etc. as required. 250 mm x 38 mm (3 compartment)
150 mm x 38 mm (2 compartment)
100 mm x 38 mm (2 compartment)
50 mm x 38 mm (2 compartment)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 150 mm. Width x 50mm. Depth x 1.6mm. Thickness.
300 mm. Width x 50mm. Depth x 1.6 mm. Thickness.
450 mm. Width x 50mm. Depth x 2.0 mm. thickness.
600 mm. Width x 62.5mm. Depth x 2.0 mm. thickness.
750 mm width X 62.5 mm depth X 2.0 mm thickness
Supply of Surface LED Downlighter made up of pressure die cast aluminum housing with approx 30 mm deep recessed high efficiency Prismatic PS diffuser and narrow rim, LED Used shall be SMD type and fixture should have minimum efficacy at System level >=100 lumens/watt with Minimum system Lumens 1600 & max wattage 15W, Life of fixture : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 4000K (SDCM<=5), CRI >=80, PF >0.95, an operating Voltage Range of 140-320 V AC. Minimum Internal Surge Protection 2.5KV. Dimensions of the products should be 167mm dia, 56mm height and 155mm cutout. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval.
Supply of recessed mounted 2X2 LED panel ,made of CRCA housing with high efficiency prismatic diffuser with UGR≤19. LED Used shall be SMD type and fixture should have efficacy at System level 120 lumens/watt with Minimum system Lumens 3600 & Max System wattage of 34W, Life of fixture : 50000 burning Hrs. @ L70B50 Lumen maintenance,CCT-4000K, (SDCM<=5), CRI Ra >=80, THD<10%, PF >0.95, an operating Voltage Range of 140 - 270 VAC.Minimum Internal Surge Protection 4.0KV & IP20/IK02 protection, Fixture should comply with to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, IEC 60598-2-2, CISPER 15 for EMC / EMI compliance with flicker free operations ripple <5%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval.
Supply of recessed mounted 2X2 LED panel ,made of CRCA housing with high efficiency PS Diffuser. LED Used shall be SMD type and fixture should have minimum efficacy at System level >=120 lumens/watt with Minimum system Lumens 2880 & Max System wattage of 24W, Life of fixture : 50000 burning Hrs. @ L70B50 Lumen maintenance,CCT-4000K (SDCM<=5), CRI Ra >=80, THD<10%, PF >0.95, an operating Voltage Range of 140 - 270 VAC.Minimum Internal Surge Protection 4.0KV & IP20/IK02 protection, Fixture should comply with to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, IEC 60598-2-2, CISPER 15 for EMC / EMI compliance with flicker free operations ripple <5%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval.
Supply of LED indoor recessed downlighter suitable for general lighting. Luminaire should have pressure die-cast Al housing with diffused optics. The luminaire should have CRI > 80 and CCT of 4000K/6500K. The luminaire shall be compliant with IP20, IK02 classification.The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 2150 lumens and maximum system wattage of 18 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 30k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 , THD <10%. The fixture housing should be available in colors aluminium and grey. Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval.
Supply of LED indoor recessed downlighter suitable for general lighting. Luminaire should have pressure die-cast Al housing with diffused optics. The luminaire should have CRI > 80 and CCT of 4000K/6500K. The luminaire shall be compliant with IP20, IK02 classification.The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 1320 lumens and maximum system wattage of 12 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 30k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 , THD <10%. The fixture housing should be available in colors aluminium and grey. Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval.
(MR)Supply, Installation, Testing and Commissioning of LED 4ft Linear with a nominal system lumen output of 2000 lumens and a minimum system efficacy of >130 lm/w @6500K. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K/4000K and CRI>80,SDCM<=5. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The Luminaire should (Flicker Free Ripple < 5% ), Hi-low cutoff circuit with auto restart feature & 4KV surge for better protection against voltage fluctuation/spikesThe luminaire housing should made of CRCA with a PC glossy diffuser. The total power consumption should not exceed 16 W (including driver). Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Fixture and driver have to be BIS certified as per the govt rule.
Supply, Installation, Testing and Commissioning of LED 4ft Linear with a nominal system lumen output of 2000 lumens and a minimum system efficacy of >130 lm/w @6500K. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K/4000K and CRI>80,SDCM<=5. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The Luminaire should (Flicker Free Ripple < 5% ), Hi-low cutoff circuit with auto restart feature & 4KV surge for better protection against voltage fluctuation/spikesThe luminaire housing should made of CRCA with a PC glossy diffuser. The total power consumption should not exceed 16 W (including driver). Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Fixture and driver have to be BIS certified as per the govt rule.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Supply, Installation, testing and commissioning of 5 star rateing 1200mm ceiling fans complete with double ball bearing, motor, blades, canopies, capacitor etc. suitable for operation on 230 volts, 50 Hz., 1 phase, AC supply complete as required. ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
(MR)Supply, Installation, testing and commissioning of 5 star rateing 1400mm ceiling fans complete with double ball bearing, motor, blades, canopies, capacitor etc. suitable for operation on 230 volts, 50 Hz., 1 phase, AC supply complete as required. ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supply of Exhaust fan complete with louver and with 3 core flexible wire as required upto socket/ ceiling boxes as required, complete with cutting of wall, grouting of fan and making good of the wall. 300 mm SWEEP EXHAUST FAN (1400 RPM)
Supplying, Installation, testing and commissioning of 450 mm dia wall bracket fan complete in all respect as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supply, Installation, Testing and Commissioning of IGBT based PWM technology UPS system of following ratings with computer communication possibilities consisting of standard software, double conversion system suitable for providing power supply to computers/servers sports lighting, corridor lighting delivery atleast 30 minutes backup, suitable for incoming 415 volts, 3phase +15% -15%, 50Hz supply and three phase output voltage, including, rectifier/dual converter, bypass switch, Manual By-pass, Inbuilt Galvanic isolation transformer (before static switch), ECO mode, inverter, filter. Bypass & static transfer switch for automatic switch over, providing static bypass module, SCR switching, high switching frequency microprocessor based with built-in technical protections like short circuits, over load, high / low voltage cut off protection of load from source inclusive of bypass facility without giving any break of power, maintenance bypass switch. The UPS should have IGBT based rectifier and IGBT based inverter.The UPS shall be provided with inbuilt Isolation transfomrer. The UPS should also give minimum 94% efficiency at 100% load.Microprocessor/ software controlled annunciation, protection (including against input phase reversal), and menu run diagnostic module, associated cabling, connections, termination, erection including associated foundation/ masonry or RCC work for mounting on base channels etc. complete as required and as per specifications. Providing & Fixing of configuration complete with maintenance-free sealed battery (SMF VRLA Type) banks and BCB consisting of (……..AH x 2V x …..Nos.) Cells SMF Type suitable for UPS System for 30 mins backup for individual UPS. Note:- Please also attach battery back up calculation alongwith quotation. 20KVA UPS with 30 min battery back up of 3 phase input & 3 phase output.
Supplying, Assembling, Transportation, Loading, unloading, shifting, erecting, testing and commissioning of 400 KVA 11KV/433V 3phase 50Hz,outdoor type copper wound, Oil type step down transformer i/c oil complete with all modern fittings as required including , lifting lugs, Roller type non-directional wheels, suitable boxes on both the ends for cable entry, disconnecting chamber on both sides,winding temprature indication & alarm, bucholz relay , earthing terminals, diagram and rating plate, explosion vent, automatic OFF load tap changer (+5% & -10%) @ of 2.5% steps etc., as required.Transformer oil with topping quantities of oil to be supplied separately,testing oil before and after commissioning to be included in scope,also if filteration is required.
(MR) Supply, transporting, loading, unloading, erecting, testing and commissionig etc. of Silent Type Diesel Generating Set of 125 KVA, 3 phase & neutral, 50 c/s. 415 A.C. rating, comprising of following Diesel Engine, Alternator, Sound Attenuated Acoustic Enclosure as detailed in technical Specifications and other associated accessories: A. A. DIESEL ENGINE: 1.Type: Multi-cylinder water cooled with direct radiator, Turbo charged with charge air cooling. 2. No. of strokes : 4 3. Fuelinjection :Direct 4. Maximum speed : 1500 RPM 5. Rated power : 159 BHP (minimum) 6. Cooling of Cylinders : Water cooled with Radiator 7. Engine Starting : Battery starting 8. Starting position : Universal. Auto/Manual B. ALTERNATOR; Type : Brushless. Actual Power 125 KVA at 50 deg C.Frequency : 50 Cycles/sec. Supply system :3 phases & neutral Connection : Star. Rated voltage: 415 Volts Rated rpm. : 1500 rpm. max. Casing protection : As per IP-23 nsulation : Class `H'. I Voltage : Automatic voltage regulator regulator (Motorised) Power factor : 0.8. Controller : Type 3100 or similer C. ACCESSORIES: The Diesel Engine shall be equipped with minimum following/ as indicated in the specifications, devices/ accessories built-in type including all standard fittings. Fuel supply pump with manual venting pump. Turbo charger with air filter (dry/oil bath type) and damper. Charge air cooler. Suction fuel filte Lube oil filter. Hourmeter and RPM indicator. Battery Starting Mechanism Instrument/Indication panel complete with the followings; a) Starting Switch with key. b) Lub. Oil Temp. gauge. c) Lub. Oil pressure gauge. d) Water Temp. gauge. Control devices for safety and monitoring alongwith indicators. D.OTHER ACCESSORIES/EQUIPMENT Common base/foundation frame. Fly wheel and flexible coupling. Automatic voltage regulator (AVR). Lub oil filter. Fuel oil filter. Day storage tank for 145 ltr capacity fabricated out of 3mm thick MS sheet, with M.S. fuel pipe line, high & low level indicator and alarm contacts. Residential type silencer Anti vibration pads Necessary batterys (minimum 2 of 180 AH capacity) with leads and mounting frame etc. The cost of initial charge of lubricants, coolant, fuel (day storage tank) etc 1 No. of 250 Amp. Rating, 4 pole MCCB, complete with metering, indications and relays/releases as indicated in the specifications and as required. (with automatic mains failure facility) All the above housed in a suitable Sound attenuated enclouser as per specifications and as required
(MR) Supply, transporting, loading, unloading, erecting, testing and commissionig etc. of Silent Type Diesel Generating Set of 320 KVA, 3 phase & neutral, 50 c/s. 415 A.C. rating, comprising of following Diesel Engine, Alternator, Sound Attenuated Acoustic Enclosure as detailed in technical Specifications and other associated accessories: A. DIESEL ENGINE: 1.Type: Multi-cylinder water cooled with direct radiator, Turbo charged with charge air cooling. 2. No. of strokes : 4 3. Fuelinjection :Direct 4. Maximum speed : 1500 RPM 5. Rated power : 399 BHP (minimum) 6. Cooling of Cylinders : Water cooled with Radiator 7. Engine Starting : Battery starting. 8. Starting position : Universal. Auto/Manual B. ALTERNATOR; Type : Brushless. Actual Power 320KVA at 50 deg C. Frequency : 50 Cycles/sec. Supply system :3 phases & neutral Connection : Star. Rated voltage: 415 Volts. Rated rpm. : 1500 rpm. max. Casing protection : As per IP-23 Insulation : Class `H'. Voltage : Automatic voltage regulator regulator (Motorised) Power factor : 0.8. Controller : Type 3100 or similer C. ACCESSORIES: The Diesel Engine shall be equipped with minimum following/ as indicated in the specifications, devices/ accessories built-in type including all standard fittings. Fuel supply pump with manual venting pump. Radiator Turbo charger with air filter (dry/oil bath type) and damper. Charge air cooler. Suction fuel filter. Lube oil filter. Hourmeter and RPM indicator. Battery Starting Mechanism. Instrument/Indication panel complete with the followings; a) Starting Switch with key. b) Lub. Oil Temp. gauge. c) Lub. Oil pressure gauge. d) Water Temp. gauge. Control devices for safety and monitoring alongwith indicators. D.OTHER ACCESSORIES/EQUIPMENT Common base/foundation frame. Fly wheel and flexible coupling. Automatic voltage regulator (AVR). Lub oil filter. Fuel oil filter. Day storage tank for 145 ltr capacity fabricated out of 3mm thick MS sheet, with M.S. fuel pipe line, high & low level indicator and alarm contacts. Residential type silencer Anti vibration pads Necessary batterys (minimum 2 of 180 AH capacity) with leads and mounting frame etc. The cost of initial charge of lubricants, coolant, fuel (day storage tank) etc 1 No. of 630 Amp. Rating, 4 pole MCCB, complete with metering, indications and relays/releases as indicated in the specifications and as required. (with automatic mains failure facility) All the above housed in a suitable Sound attenuated enclouser as per specifications and as required Diesel Generating set as described above.
SECTION - VIIÌ -MAIN LT PANEL MAIN LT PANEL WITH AUTO DG ON/OFF LOAD SHARING & MANAGEMENT PANEL Supply, installation, testing and commissioning of dust, damp and vermin proof cubicle free floor,Indoor Type IP-43 built sheet steel enclosed modular bolted construction extendable MAIN LT PANEL WITH AUTO DG ON/OFF LOAD SHARING & MANAGEMENT PANEL , suitable for operation on 415 ± 10% volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of suitable sized square tubular section and covered with CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extensible type TPN Aluminium bus bars of high conductivity, SMC bus bar supports, with bottom base channel of section not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a common G.I. earth bus bar to switch gears with required size of Alum. bus bars and inter-connection with solid copper conductor wires / aluminium strips, neutral links, including control wiring with 1.5 / 2.5sqmm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, etc.necessary metering protections & indications and mounted with the following switch gears as per drawing and technical specifications etc. complete as required. Incoming & outgoing bus ducts/ cables will be from bottom & top both sides as per site requirement. Proper heat dissipation system should be provided in the panel. Panel should be Ethernet ready. All ACBs & MCCBs in Main Panel must communicate on MODBUS TCP/IP.Incomers:800 Amp. 4 Pole MCCB - 1 set (For Transformer supply) MCCB of fault breaking capacity 25ka FP Microprocessor release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection.Metering, indications and protections for each incomer:a) LED indication lamps for RYB, breaker 'ON/ OFF/ TRIP', spring charged, DC control supply healthy etc with 2Amp control MCBs b) Set of Digital flush type multifunction meters (with RS485 port) 0- 320A, class - 0.5 accuracy , showing V, A, PF, Hz, KW, KWH, KVAR, etc. with 3 Nos. cast resin current transformers of 320/5 Amp ratio, 15 VA Class 0.5 metering - FOR TRANSFROMER. c) Under voltage/ Overvoltage with definite time relay & master trip relays - 1 set for Transformer incomer. d) Suitable size & nos of CT's for all protection relays (class 5P10, 15VA) & APFC Relay (class 0.5, 15VA) as per drawings e) Surge Protection Device of type 1+ 2 of 25KA.630 Amp. 4 Pole MCCB - 1 set (For 320KVA DG supply) MCCB of fault breaking capacity 25ka FP Microprocessor release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. Metering, indications and protections for each incomer: a) LED indication lamps for RYB, breaker 'ON/ OFF/ TRIP', spring charged, DC control supply healthy etc with 2Amp control MCBs b) shut trip coil c) Under voltage and RPR - 1 no. 250 Amp. 4 Pole MCCB - 1 set (For 125KVA DG supply) MCCB of fault breaking capacity 25ka FP thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. Metering, indications and protections for each incomer: a) LED indication lamps for RYB, breaker 'ON/ OFF/ TRIP', spring charged, DC control supply healthy etc with 2Amp control MCBs b) shut trip coil c) Under voltage and RPR - 1 no. BUS COUPLER 250Amp. 4 Pole MCCB - 1 set MCCB of fault breaking capacity 25ka FP thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection.Bus Bar 1=1000Amp & 2=250Amp :TPN aluminium extensible type main bus bars of minimum of 1000/250 Amps. capacity & auxiliary Bus Bars of suitable capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25ka capacity. Outgoings:SECTION 1 1 No. - 250 Amp. 25ka Three pole thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. (Cap. Panel) 2 Nos. - 200 Amp. 25ka four pole thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. (OD AC panel, spare) 2 Nos. - 125 Amp. 25ka four pole thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. (2nd floor panel, spare) 3No. - 100 Amp. 25ka four pole thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. (OD AC panel,ground floor, spare) SECTION 2 8 Nos. - 63 Amp. 25ka four pole thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. (AC OD panel,lift, UPS, Fire fighting, first floor , plumbing panel, 2 spare) 1 Nos. - 40 Amp. 25ka four pole thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. (External lighting) Each outgoing breaker shall have the following accessories- c) Extended rotary operating mechanism, terminal extension spreaders, LED indication lamps with 2Amp control MCB for breaker 'ON/OFF' for all MCCB's. MAIN LT PANEL WITH AUTO DG ON/OFF LOAD SHARING & MANAGEMENT PANEL
CAPACITOR PANEL APFC - 110 KVAr 110 KVAR with heavy duty capacitors units in a bank formation to achieve Automatic operation. suitable for operation on 415 ±10% volts, 50 Hz AC 3 phase 4 wire supply system as per drawing and technical specifications etc. complete as required. Automatic P.F.C.R. 7 stage with power factor meter & CT's for unbalanced load - 1 Set. Bus Bar : TP aluminium extensible type main bus bars of minimum of 250 Amps. capacity & auxiliary Bus Bars of suitable capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25ka capacity. utgoings :- Control MCB/ MCCBs with capacitor banks: 63Amp. TP MCCB '25ka' Thermal Magnetic release having O/L & S/C protection with 25 KVAr, 415V (fixed) Heavy duty capacitor bank etc. - 1 set. 63Amp. TP MCCB '25ka' Thermal Magnetic release having O/L & S/C protection with 25 KVAr, 415 V Heavy duty capacitor bank, Capacitor Duty Contactor etc - 2 sets. 32 TP MCCB '25ka' Thermal Magnetic release having O/L & S/C protection with 10 KVAr, 415 V Heavy duty capacitor bank, Capacitor Duty Contactor etc - 2 sets. 25 TP MCCB '25ka' Thermal Magnetic release having O/L & S/C protection with 5 KVAr, 415 V Heavy duty capacitor bank, Capacitor Duty Contactor etc - 3 sets. APFC panel as above
FLOOR PANEL Design, manufacture, supplying fixing in position of the following front operated cubicle type,compartmentalised with front access, dead back, 2mm thick steel enclosed free standing, dust and vermin proof, switchboard with IP52 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 25 kA symmetrical at 415 volts. The panel shall be as per sepcifications & tested, in accordance with IS 8623 assembley ammended till date All switchboards shall be modular type and have provision for entry of cables from the top /bottom as required. All Main & Sub panels shall have Surge protection devices of Class B& C/Type-1&2 metal encapsulated as per NBC-2016 & IS/IEC-62305 as per classes defined. The cost shall include providing and fixing of 100 x 50 x 6 mm channels for switchboard support. Ground Floor Incoming 1 No. - 100 Amps Four Pole, 25 KA (ICU=ICS), MCCB with thermal magnetic release with o/c, s/c, E/F protection release all indication, front operating handle & door interlock with Ammeter & voltmeter Busbar: TPN aluminium bus bars of minimum of 125 A, 25 kA capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. Indication Lamp Outgoing 63 Amp 4P MCB '10ka' 'C' - 4 Nos. (1no. Spare) 40 Amp 4P MCB '10ka' 'C' - 4 Nos. (1no. Spare)
First Floor Incoming 1 No. - 63 Amps Four Pole, 25 KA (ICU=ICS), MCCB with thermal magnetic release with o/c, s/c, E/F protection release all indication, front operating handle & door interlock with Ammeter & voltmeter Busbar: TPN aluminium bus bars of minimum of 100 A, 25 kA capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. Indication Lamp Outgoing 63 Amp 4P MCB '10ka' 'C' - 3 Nos. (1no. Spare) 40 Amp 4P MCB '10ka' 'C' - 2 Nos. (1no. Spare)
Second Floor Incoming 1 No. - 125 Amps Four Pole, 25 KA (ICU=ICS), MCCB with thermal magnetic release with o/c, s/c, E/F protection release all indication, front operating handle & door interlock with Ammeter & voltmeter Busbar: TPN aluminium bus bars of minimum of 160 A, 25 kA capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. Indication Lamp Outgoing 63 Amp 4P MCB '10ka' 'C' - 5 Nos. (1no. Spare) 40 Amp 4P MCB '10ka' 'C' - 3 Nos. (1no. Spare)
External Lighting Panel (MR) Supply, assembly, erection, connecting, testing & commissioning of LT weather proof dust and vermin proof, outdoor feeder pillar, fabricated out of suitable sized angle iron and flats and covered with 3mm thick CRCA sheet steel including canopy, duly stove enamel painted, both sides (front and rear) openable with locking arrangement, rubber gasket cable glands, etc. Bakelite phase separators and bus bar supports including RCC 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) foundation, 450 mm deep and 150 mm above the ground. The feeder pillars shall be complete with 3 phase and neutral bus bars of capacities as described below and moulded case circuit breakers (MCCBs) with adjustable overload relay, copper FRLS control wiring with 1.5sq.mm, complete in all respects as per specifications as required. INCOMING:- 40A 4P MCCB (25ka) with thermal magnetic release & rotary handle - 1no. 3 Phase and neutral (100%N) aluminium bus bars of 100 amps. Capacity. OUTGOING:- 50AMP. TP CONTACTOR WITH NO/ NC CONTACTS -1 set. 24 HOUR TIMER - 1 set. 25A 4P MCB (10ka) - 2os. 16A DP MCB (10ka) - 5 nos. 63A 4P MCB (10ka) - 2 no. 16 AMP. SWITCH & SOCKET - 1 no. with in the feeder pillar. External Lighting Feeder Pillar as above
LIFT Panel INCOMER 1No. 63A FP MCCB (25 KA) icu=ics with thermal magnetic release with o/c, s/c, E/F protection release all indication, front operating handle & door interlock with Ammeter & voltmeter METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 320/5A CT's On, Off, Trip indicating lamps,spreader links,trip alarm cancellation - 1 Set BUS-BAR 1 Set of 80A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 2No. 63A TP MCCB with fixed neutral link (16 KA) 1 No. 40A TP MCCB with fixed neutral link (16 KA) 12 Nos. 40A DP MCB (10 KA) Lift Panel as above & as per SLD
UPS - PANEL Incoming 1 No. - 63 Amps Four Pole, 16 KA (ICU=ICS), MCCB with thermal magnetic release with o/c, s/c, E/F protection release all indication, front operating handle & door interlock with Ammeter & voltmeter Busbar: TPN aluminium bus bars of minimum of 80 A, 25 kA capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. Indication Lamp Outgoing 63 Amp 4P MCB '10ka' 'C' - 2 Nos. (1no. Spare) 40 Amp 4P MCB '10ka' 'C' - 3 Nos. (1no. Spare) UPS Panel as above & as per SLD
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. Pipe earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. Pipe earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply of following size of 1.1 kv grade FRLS multicore aluminium / copper conductor XLPE insulated and PVC sheathed armoured cable as per IS: 7098:1988 (Part-I) with upto date amendments. 3-½ x 300 Sq.mm.(DG to LT)
3-½ x 240 Sq.mm.(transformer to LT)
3-½ x 185 Sq.mm.(DG to LT)
3-½ x 150 Sq.mm.(LT to CAP.)
3-½ x 70 Sq.mm.( LT to floor panel)
3-½ x 35 Sq.mm.( LT to floor panel)
4 x 10 Sq.mm. copper (power DB) (UPS)(Lift)
4 x 6 Sq.mm. copper ( light DB and UPS DB)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(9.1.30)3-½ x 300 Sq.mm.(70mm)
3-½ x 240 Sq.mm.(62mm)
3-½ x 185 Sq.mm.(62mm)
3-½ x 150 Sq.mm.(50mm)
3-½ x 70 Sq.mm.(38mm)
3-½ x 35 Sq.mm.(30mm)
4 x 10 Sq.mm. (25mm)
Supply, installation, testing & commisioning of cable termination of above cables with copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required. 4 X 6 sq. mm (25mm)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface in existing cable trench/pipe as required.(7.7.4) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supplying, installation, testing & commissioning of intelligent analog addressable smoke Detector detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of intelligent addressable Thermal/Heat Detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying and installation of photo luminescent safety signage made up of LED based exit signage with 90 min. battery backup as per NBC including arrangement for fixing on wall / ceiling etc. complete as required (single sided) (size 150 mm x 300 mm) Exit Sign and Internal Hydrant illuminated Sign.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required 2 x 1.5 sq.mm (fire alarm)
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Single pair, 2-core, 1.5 sqmm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supply, installation, testing & commissioning of Fixed lense 4 X 1/1.9" 2 MP progressive CMOS High Resolution 4096(H) × 1800(V) coloured IP based fixed dome camera with suitable varifocal LENS, Minimum illumination 0.006 lx, 12 V DC operation, having features like wide dynamic range, True Day Night, Digital Noise Reduction, backlight compensation tc. complete as required per specifications & approved by the Engineer In charge.
Supply, installation, testing & commissioning of IP based IP66 based 4K Outdoor Bullet camera: 1/2” 8 Megapixel progressive CMOS, b) Lens Type 3.7mm~11mm, Motorized, F1.9 Weather-proof IP66 Housing, 12/24 V DC operation, having features like backlight compensation, wide dynamic range, 3D NR aluminium housing, UL/ CE Certification etc. complete as required as per specifications & approved by the Engineer In charge.
Supply, installing, testing and commissioning of managed 24 port POE and 12 V DC power supply unit etc. as required per specifications & approved by the Engineer In charge.
Supplying, laying, terminating & connecting of 4 Pair CAT-6 Cable for CCTV in terminations, in existing M.s conduit/cable tray, labour and other petty material etc. complete as required & approved by the Engineer In charge.
Supplying, laying, terminating & connecting of 6 Core multimode armoured Fibre Optic cable, in existing M.s conduit/pipe/cable tray, labour and other petty material etc. complete as required & approved by the Engineer In charge.
Supply, installation, testing & commissioning of 32" high resolution colour monitor for viewing CCTV camera's, etc. complete as required per specifications & approved by the Engineer In charge.
Supply, installation, testing and commissioning of Operator work station with PC having Intel i7, 3.4 GHz including Serial ports (RS232,485) and USB ports and following accessories etc. all as specified. Minimum 8 Gigabyte of RAM memory 2TB (minimum) of hard disk space DVD Combo Drive 21” LED colour monitor Optical Mouse with 2 Mouse Pads Standard Key Board Laser Printer colour A4- size. 1KVA online UPS with a SMF battery of half hour backup at full load.
2 Pole Structure with GO/DO Arrangement Supply, installation (inclusive all civil works for making of foundation), testing & commissioning of 11KV, 2 pole structure (poles I beam galvanised) for receiving 11KV overhead supply line & for termination of 11KV load side O/G cable; complete with 11KV pin / disc insulators, all GI cross - members / supports with GI hardwares, GI stay wires, complete with 3 nos. single pole Lightning Arrester, station type, heavy duty, lighting arrestor suitable for 11KV solidly earthed neutral system complete with suitable bimetallic connectors for wire/ cable connections, all accessories etc. and 11KV 630A TP gang operated off-load AB switch with extended handle upto pole bottom, ground earthing of structure, 150mm dia GI pipe for incoming & outgoing 11KV cables, GI clamping complete in every aspect with all accessories etc. complete as required & approved by the local electricity board authority.
METERING INDOOR UNIT Supply and installation of indoor type 11KV metering unit with copper conductor flexible FRLS control cables ISI marked and G.I pipe etc. (including required CT, PT's & energy meter) & as per the approved design of local electricity board authority only etc. complete as required.
Supplying, laying, testing commissioning of the following sizes of FRLSZH 11KV Alum. Earthed, Armoured XLPE MV power cable as per IEC 60502, amended up-to-date, and as per specifications. 11 KV (E), 3C x 185 Sq. mm XLPE Aluminium Armoured cable
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required per specifications. 185 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required as required per specifications. 185 sq. mm
Supply of Voltas make Variable Refigerant Flow (VRF) air- conditioning system cooling only with higly efficient DC inverter driven compressors complete with indoor and outdoor units with individual controllers and with fittings etc, as per quantity given below. The VRF can operate stably in a wide ambient temperature range: from -5°C to 55°C in cooling mode. The units are precharged with R-410A refrigerant gas, complete with duly powder coated etc as required. The outdoor unit heat exchangers have innovatively designed inner grooved type copper piping to enhance heat exchange and increase the subcooling of refrigerant to reduce system resistance and improve reliablility.The heat exchangers are specially designed for corrosion resistance with blue fin treatment. 20 HP
34 HP (22HP +12HP)
86 HP (22HP+22HP+22HP+20HP)
Supply of 4-Way Circular Air Flow Cassette Unit with 360°direction air flow , high efficient DC fan motor with seamless airflow with auto swing louver, dx copper coil, prefilter, fan section, electronic expansion valve, corded remotes etc. Minimum capacities of each Evaporative units are as follows: 0.8 TR
Supply of Refnets
ITC of Voltas make Variable Refigerant Flow (VRF) air- conditioning system cooling only with higly efficient DC inverter driven compressors complete with indoor and outdoor units with individual controllers and with fittings etc, as per quantity given below. The VRF can operate stably in a wide ambient temperature range: from -5°C to 55°C in cooling mode. The units are precharged with R-410A refrigerant gas, complete with duly powder coated etc as required. The outdoor unit heat exchangers have innovatively designed inner grooved type copper piping to enhance heat exchange and increase the subcooling of refrigerant to reduce system resistance and improve reliablility.The heat exchangers are specially designed for corrosion resistance with blue fin treatment. 20 HP
34 HP (22HP +12HP)
96 HP (22HP+22HP+22HP+30HP)
ITC of 4-Way Circular Air Flow Cassette Unit with 360°direction air flow , high efficient DC fan motor with seamless airflow with auto swing louver, dx copper coil, prefilter, fan section, electronic expansion valve, corded remotes etc. Minimum capacities of each Evaporative units are as follows: 0.8 TR
ITC of Refnets
Lifting & Shifting of ODU from Ground Level to terrace Level or as per site requirement
Refrigerant piping and piping accessories Supply, Installation and Testing of Hard/soft Copper refrigerant piping of required sizes for suction & liquid, with Superlon/Accoflex insulation material for the gas/liquid line. All the copper piping covered with Insulation as per specifications
Control cabling Supply, Installation and Testing of Control cabling with copper conductor min. 2 core x 1.5 sq.mm. cable with end termination for Indoor units enclosed in PVC Conduit
Drain Piping Supply, Installation and Testing of Drain piping in hard cPVC with all fittings, properly insulated with nitrile rubber, supports and clamps, including drilling hole in wall to route the drain pipe
Refrigerant Gas Top-up required Supply and Charging of extra Gas required for all the above units as per Copper Piping length and the Indoor unit capacity (With R410A Gas)
Supply, installation, testing and comissioning of wall Louvers with damper suitable for Fresh Air 350x300 mm
SITC of Inline fans ( with necessory supports arrangement) complete with 1Ph/3 Ph motor, frame for fixing, impeller, outlet cowl piece with protective wire mesh etc. . Power cabling from this switch socket to fans shall be included in the unit rates.Capacities shall be as under. CAPACITY-1100 CFM (Fresh Air Fan ) ESP-25mmwc
CAPACITY-600 CFM (Fresh Air Fan ) ESP-25mmwc
CAPACITY-370 CFM (Fresh Air Fan ) ESP-25mmwc
CAPACITY-300 CFM (Fresh Air Fan ) ESP-25mmwc
CAPACITY-250 CFM (Fresh Air Fan ) ESP-25mmwc
SITC of Flexible Duct
INSTALLATION OF 8 PASSENGER LIFT
HONSING TIMUNG (BID ID -249267)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .