| 1 | L1₹24.8 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | ₹24.8 L Quoted ₹25.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹27.9 L+₹2.0 L (7.69%)Rejected-Finance | ₹27.9 L+₹2.0 L (7.69%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹28.2 L+₹2.3 L (9.04%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | ₹28.2 L+₹2.3 L (9.04%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹30.1 L+₹4.3 L (16.5%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | ₹30.1 L+₹4.3 L (16.5%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹30.2 L+₹4.3 L (16.7%)Rejected-Finance V PO RAIKO KI DHANI NAWAJI KA PANA BHURTIYA DISTT BARMER RAJ PIN 344001 | BARMER | RAJASTHAN | 344001 | ₹30.2 L+₹4.3 L (16.7%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 May 2023, 6:00 pmClosed
GE (AF) Utarlai
GE (AF) Utarlai PB No. 11 Barmer 344001
REPAIR TO INTERNAL ELECTRIFICATION ITEMS AT AF STN UTARLAI
2023_MES_587883_1
8373/E8
Open Tender
Civil Works
Item Rate
180 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹70,000
Yes
8 Jul 2023
31 Mar 2023
8 May 2023
1 Apr 2023
5 May 2023
21 Apr 2023
Amount
Taking down any type of copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. complete including making good the disturbed surfaces of walls, ceilings complete all as specified and as directed.
M&L for Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded FRLS flexible copper conductor cable in and incl rigid PVC conduit concealed with pressed mild steel terminal boxes duly painted with a coat of red oxide primer fixed flushed to the wall with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire to common earth dolly, including cutting chases in brick/ block/stone masonry wall , replastering and making good to match the existing specifications complete all as specified and directed by Engr-in-charge. Note: a) Unit rate include for cutting chases for conduits and sunken boxes and making good to wall, floors etc
All as per item No 2 but for one 3 pin 5 Amp socket outlet on independent board.
M&L for Point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with pressed steel terminal boxes of adequate size fixed flushed to the wall with 3mm thickness plastic laminated sheet cover for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS,PVC insulated and unsheathed copper conductor cable (multistranded) as earth wire to common earth dolly, including cutting chases in brick wall/block/stone maonry wall, replastering and making good to match the existing specificationscomplete all as specified. Note: a) Unit rate include for cutting chases for conduits and sunken boxes and making good to wall, floors etc.
M&L for Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable in existing concealed conduit with replacement of pressed steel terminal boxes with 3mm thick plastic laminated sheet cover of existing size and shape for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire to common earth dolly complete all as specified and directed by Engr-in-charge.
All as per item No 5 but for one 3 pin 5 Amp socket outlet on independent board.
All as per item No 5 but for one 3 pin 5 Amp socket outlet on same board.
All as per srl item No 5 here in before but one bell/buzzers point controlled by one push button on the same board with other inner switches or independent with cable 1.5 sqmm size all as per specified and directed.
M&L for Point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in existing concealed conduit with replacement of pressed steel terminal boxes with 3mm thick plastic laminated sheet cover of existing size and shape for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm multistranded copper conductor cable FRLS PVC insulated and unsheathed Cable as earth wire to common earth dolly, complete all as specified.
M&L for Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded FRLS flexible copper conductor cable in and incl PVC casing caping with pressed mild steel terminal boxes duly painted with a coat of red oxide primer fixed flushed to the wall with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire to common earth dolly complete all as specified and directed by Engr-in-charge.
All as per item No 10 but for One 5 Amps socket point controlled by switch on the same board with other switches
All as per item No 10 but for one 3 pin 5 Amp socket outlet on independent board.
All as per item No 10 but for one bell point controlled by one bell push
M&L for Point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in and including PVC casing caping of suitable size with pressed steel terminal boxes of adequate size fixed flushed to the wall with 3mm thickness plastic laminated sheet cover for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS,PVC insulated and unsheathed copper conductor cable (multistranded) as earth wire to common earth dolly, complete all as specified.
S&F switch piano flush button single pole one way 5 amps 230 volts,complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 5 amps 5 pin flush type, 230 volts, complete all as specified and directed by Engr-in-Charge.
S&F switch socket combination 2 in 1, 5 pin, 5 Amp flush type.
S&F in switch socket combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal.
S & F switch bell push, flush type, 5 amp one way complete.
S&F fan regulator electronic flush type stepped (rotary type) with 5 steps speed control complete all as specified complete
S&F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings complete
S&F ceiling rose surface bakelite three terminal isolated body fixed on PVC round block complete all as specified.
S&F in replacement LED tube light fitting 1x20w,230v, including LED glass tube cylindrical rod (4 feet) with in built driver with metal heat sink, double sided connection including 4 feet box type batten fitting fixtures, complete with all accessories internally pre-wired and including connecting up with two core flexible copper conductor cable of suitable size complete including taking down old fitting all as specified Make: Crompton Cat Pt No. LT8-20-865-(2) (tube), DMLN1LT8-16 (batten)/ ORIENT CAT Pt No. LIBT-118-SS (Batten), LTXL-20-C (tube) or equivalent in philips/Havells Note: The above item will consists of two items i.e (i) LED tube rod 20W (ii) Box type batten
S&F in replacement LED tube light fitting 1x8w,230v, including LED polycarbonate tube cylindrical rod (2feet) with in built driver with metal heat sink, double sided connection including 2 feet box type batten fitting fixtures, complete with all accessories internally pre-wired and including connecting up with two core flexible copper conductor cable of suitable size complete including taking down old fitting all as specified Make: Crompton Cat Pt No. LT8-8-565-(2) (tube), DMLN1LT8-8 (batten) or equivalent in philips/Orient/Havells Note: The above item will consists of two items i.e (i) LED tube rod 20W (ii) Box type batten
Supply and fix in replacement LED street light 20 W, with aluminium pressure die cast housing, glass in the front with complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size including taking down old fitting all as specified. Make: Orient Cat Pt No. LSFS-020-CF or equivalant in Crompton/Havells/Philips
M&L in replacement bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed.
S&F in replacement sheet metal powder coated versatile double door Triple pole and neutral (TPN) distribution system for MCB provisions, 415 Volts, 50 Hz AC supply 4 way. fitted with two cover with copper bus bar rated 200 amps neutral link, earth bar and din rail complete including taking down old DB all as specified.
S&F in replacement MCB TPN 63 Amps all as specified and directed.
S&F in replacement sheet metal powder enclosure powder coated versatile double door single pole and neutral (SPN) distribution board for MCB provisions 230Volt, 50Hz AC supply for 04 way. fitted with copper bus bar rated 200amps, neutral link , earth bar including making good the disturbed surface complete including taking down old DB all as specified.
All as per item No. 29 but for (SPN) DBs 08 way.
All as per item No. 29 but for (SPN) DBs 12 way.
S&F in replacement MCB single pole and neutral (SPN) 63 Amps all as specified and directed.
S&F in replacement MCB single pole and neutral (SPN) 40 Amps all as specified and directed.
S&F in replacement MCB single pole and neutral (SPN) 10 to 32 Amps all as specified and directed.
S&F in replacement MCB single pole (SP) 6 to 20 Amps all as specified.
S&F in Replacement of sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (multistranded) having nominal area 2.5 Sqmm drawn through existing conduit concealed type and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 2.5 Sqmm as a earth continuity conductor drawn through existing PVC conduit, including cutting chases in brick wall wherever necessary, replastering and making good to match the existing specifications including taking down old submain wiring complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of conduit and making holes in wall/floor for passing in or through conduit (ii) Two run of 2.5 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 2.5 sqmm copper conductor cable (FRLS) as a earth lead will be measured as a one run unit length.
All as per item No. 36 as above herein before but with 2 run of 4.0 Sqmm and one run of 4.0 Sqmm as earth continuity conductor complete all as specified & directed.
All as per item No. 36 as above herein before but with 2 run of 6.0 Sqmm and one run of 6.0 Sqmm as earth continuity conductor complete all as specified & directed.
All as per item No. 36 as above herein before but with 2 run of 10.0 Sqmm and one run of 10.0 Sqmm as earth continuity conductor complete all as specified & directed.
S&F in replacement of existing sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (multistranded) having nominal area 2.5 Sqmm drawn into and including PVC casing caping of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 2.5 Sqmm as a earth continuity conductor in and including in PVC casing caping, including cutting chases in stone masonry wall wherever necessary, replastering and making good to match the existing specifications complete including taking down old submain wiring all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included cutting chases for making holes in stone masonry to pass the casing caping in wall/floor. (ii) Two run of 2.5 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 2.5 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC casing caping of suitable size will be measured as a one run unit length.
All as per item No. 40 as above herein before but with 2 run of 4.0 Sqmm and one run of 4.0 Sqmm as earth continuity conductor complete all as specified & directed.
All as per item No. 40 as above herein before but with 2 run of 6.0 Sqmm and one run of 6.0 Sqmm as earth continuity conductor complete all as specified & directed.
S&F in replacement electric bell ding dong AC single phase 230 volts, complete all as specified and directed
S&F in replacement electric bell multi music AC 230 volts complete all as specified and directed.
S&F in replacement LED bulb of capacity 9 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Taking down any type of copper/aluminium flame proof point wiring (light, fan) complete, including fixture and fittings such as rotary switches, steel conduit etc. complete including making good the disturbed surfaces of walls, ceilings complete all as specified and as directed.
M&L Point wiring for flame proof light point controlled by one switch with 1100 volts grade 1.5 sqmm PVC insulated unsheathed FRLS multistranded copper conductor cable as per IE colour code for phase /neutral /earthing wire drawn into and including rigid in stove enamelled mild steel ERW conduit medium grade minimum 20mm dia and accessories concealed in walls/roof/floors with continuous 1.5 sqmm PVC insulated unsheathed FRLS multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly complete including cutting chases in brick/ block/stone masonry wall , replastering and making good to match the existing specifications complete all as directed.
S&F in replacement for flame proof wiring with 2 runs of 4.0 sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and included ERW mild steel conduit of minimum 20mm dia external (which shall be increased as per actual site requirement in Accordance of clause No 19.125.07 SSR part -I) with all conduit accessories like bends,juction boxes etc and FRLS PVC insulated unsheathed copper conductor wire of 4.0 Sqmm as a continous earth wire fixed on wall surface /ceiling . Note : 2 runs of 4.0 sqmm FRLS PVC insulated unsheathed copper conductor and 1 run of 4.0 sqmm FRLS PVC insulated unsheathed copper conductor and 1 run of Steel conduit of size 20 mm will be measured as single run.
Supply and fix FLP/WP switch 16 Amp, 250V single pole ON/OFF rotary type with termination box in LM6 all as specified and directed by Engr-in-Charge.
Supply and fix FLP/WP switch 25 Amp, 250V double pole ON/OFF rotary type with termination box in LM6 all as specified and directed by Engr-in-Charge.
S&F in repair LED flame proof weather proof flood light fitting 40 watt recommended for gas/vapour group of IIA &IIB and zone 1&2, die cast aluminium housing with heat resistant toughened glass IP 65 protection, constant current LED driver, prewired with all accessories complete fitting. Make: Crompton Cat Pt No.FWL 1315-40-CDL or equivalent in Sudhir/Shyaam. Note: The light fitting should be fixed on height upto 15 mtr include taking down old fitting. All T&P for working at site shall be deemed to be included in the quoted rates.
S&F in repair LED 150 watt flood light, energy saving, environmently friendly, long life, exclusive innovative die cast aluminium IP65/IP66, prewired and including, driver, surge protection device, connector for connecting lamp with all fixing accessories, including anti bird spikes fixed on the rear side of the fitting complete. Note: The light fitting should be fixed on height upto 15 mtr include taking down old fitting. All T&P for working at site shall be deemed to be included in the quoted rates. Make: Crompton Cat Part No. LSDN-15 CDL/TL/WW or equivalent in Philips/Havells/Bajaj/Orient
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
Supply and fixing in repair of cable PVC 3 core 1.5 Sqmm multi stranded copper conductor 1100 Volts grade drawn through rigid steel conduit medium grade 20mm dia stove enamelled fixed on walls/ truss upto height 15 Mtr complete all fixing arrangements like steel clamps, steel saddle including taking out old cable and conduit. Note: The cable should be fixed on height upto 15 mtr include taking down old cable and conduit. All T&P for working at site shall be deemed to be included in the quoted rates.
S&F in repair LED 15W downlighter with square aluminium housing, prewired and including, driver, connector for connecting lamp with all fixing accessories including taking down old fitting complete all as specified and directed by Engr-in-Charge. Make: Crompton Cat Part No. LSDN-15 CDL/TL/WW or equivalent in Philips/Havells/Bajaj/Orient
S&F in repair LED 12W downlighter with round surface mounted LED flat panel, PDC aluminium housing, prewired and including, driver, connector for connecting lamp with all fixing accessories including taking down old fitting complete all as specified and directed by Engr-in-Charge. Make: Crompton Cat Part No. LSDN-15 CDL/TL/WW or equivalent in Philips/Havells/Bajaj/Orient
M&L for cleaning complete main DB/energy meter enclosure by removing the dust deposits using suitable blower/brush, checking all the connections, tightening the screws, nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts, all a directed by Engr-in-Charge all as specified and directed.
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as Main DB's,switches, sockets, fan regulator, replacement of MCB (light/power), lamp holders (bracket/ batten), bell/buzzer, push button, ceiling rose, capacitors, tube light fitting any type, ceiling lights, Flame Proof MCDB, rotary type switch single pole/double pole, switch socket and plug combined, tube light fitting, flood light fitting and other similar electrical items/fittings etc. including providing of small pieces of electrical wire of size 1 sqmm to 10 sqmm single core and length not exceeding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge. Note :- (i) Any accessories found unserviceable that shall be replaced under respective items of this Sch and shall be measured & paid seperately under Srl item No. 58.01 to 58.44 (ii) Other items like stationery, rent of T&P, misc items like insulation tape, screws, nuts & bolts are deemed to be included in the rates quoted by the contractor. Note for item No. 58:- (i) Contractor will arrange minimum 4 well experienced electrician to attend repair of internal electrical system at site as required by Engr-in-Charge throughout the contract period from 0900 Hrs to 1700 Hrs and should complete the assigned job within 48 Hrs after receipt of the assignment. If the contractor fails to completed the assigned job in the given time recovery will be made Rs. 50.00 @ Per Job. The working staff will be provided with hygenic materials like hand sanitizer, mask, gloves etc (ii) Details of repair to be collected throughout the contract period from JE E/M at 0900 Hrs from office located at Tech Area. Register of repair should be prepared by the contractor and details of repair to be updated in the register after completion of every repair work. (iii) Contractor will arrange vehicle, electrical tools, folding ladder, misc item like insulation tape, screws, nuts and bolts for repair work. (iv) The cost of T&P required to carry out the repair in OTM Accn upto height of 15 meter is deemed to be included in quoted rates.
Supply only the following spares, fitting and fixtures for the repair :-
Switch piano type, 5 Amps 250 Volts single pole one way complete.
Switch piano flush type, single pole, two way, 5 amps complete.
Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete.
Socket outlet 2 in 1, 3 pin 5 Amp complete.
Switch socket combination 2 in 1, 5 Amp flush type complete.
Bell push, flush type, 5 A complete.
Ceiling rose surface bakelite 65x 60 mm, 3 terminal complete.
Fan regulator electronic flush type 250 volts suitable for ceiling fan complete.
Lamp holder angle type, PVC/Polycarbonate type with back plate suitable for batten fittings complete
Bell electric ding dong, AC, 230 volts, single pole complete.
LED tube light fitting 1x20w,230v, including LED polycarbonate tube cylindrical rod (4 feet) with in built driver with metal heat sink, double sided connection including 4 feet box type batten fitting fixtures, complete with all accessories internally pre-wired and including connecting up with two core flexible copper conductor cable of suitable size complete all as specified Make: Crompton Cat Pt No. LT8-20-865-(2) (tube), DMLN1LT8-16 (batten) /ORIENT CAT Pt No. LIBT-118-SS (Batten), LTXL-20-C (tube) or equivalent in philips/Havells Note: The above item will consists of two items i.e (i) LED tube rod 20W (ii) Box type batten
LED polycarbonate cylindrical tube rod 1x20W,230V (4 feet) with inbuilt driver double sided connection, suitable for existing 4 feet batten fitting fixtures, complete with all accessories internally pre-wired complete. Make: Crompton Cat Pt No. LT8-20-865-(2) (tube)/ORIENT CAT Pt No.LTXL-20-C (tube) or equivalent in philips/Havells
LED tube light fitting 1x8w,230v, including LED cylindrical polycarbonate tube rod (2 feet) with in built driver with metal heat sink, double sided connection including 2 feet box type batten fitting fixtures, complete with all accessories internally pre-wired and including connecting up with two core flexible copper conductor cable of suitable size complete all as specified Make: Crompton Cat Pt No. LT8-8-565-(2) (tube), DMLN1LT8-8 (batten) or equivalent in philips/Orient/Havells Note: The above item will consists of two items i.e (i) LED glass tube rod 20W (ii) Box type batten
LED polycarbonate cylindrical tube rod 1x8W,230V (2 feet) with inbuilt driver double sided connection, suitable for existing 4 feet batten fitting fixtures, complete with all accessories internally pre-wired complete. Make: Crompton Cat Pt No. LT8-8-565-(2) (tube)/ORIENT CAT Pt No.LTXL-09-C (tube) or equivalent in philips/Havells
Recessed mounting LED light fitting 36 W (2 X2 ft) , 230V, not less than 100 lumen per watt for POP/modular /gypsum internally pre wired, driver complete. Make: Crompton Cat Pt No. LCTLRNE-36 FO CDL or equivalent in philips/Orient/Havells
LED street light 20 W IP 65, with aluminium pressure die cast housing, toughened glass in the front with complete with all accessories internally pre-wired complete. Make: Orient Cat Pt No. LSFS-020-CF or equivalant in Crompton/Havells/Philips
Single pole and neutral metal enclosure with a two pin and socket complete with space for one SPN MCB 240 volts complete all as directed by Engr-in-Charge.
MCB Triple pole and neutral, 240 Volts 63 Amps.
MCB single pole and neutral, 240 Volts 16 to 40 Amps.
MCB single pole, 240 volts 6 to 20 Amps.
2 core flexible PVC copper wire of size 40/.0076
Capacitor 2.5 mfd, 230 volts, 50 Hz for ceiling fan, complete
Rubber shackle and split pin with galvanised clamp complete with nuts, bults washer, complete suitable for ceiling fan.
LED driver (Current Constant) for capacity of 75W, 240Volts Make: Philips/Havells/Crompton/Orient or Equivalent
LED driver (Current Constant) for capacity of 40/ 42W, 240Volts Make: Philips/Havells/Crompton/Orient or Equivalent
Surge arrester of capacity 5 KV suitable for LED 150 Watt flood light 240 volts Make: Philips/Havells/Crompton/Orient or Equivalent
LED driver (Current Constant) for capacity of 38W, suitable for flame proof flood light fitting 240 Volts Make: Philips/Havells/Crompton/Orient or Equivalent
LED driver (Current Constant) for capacity of 20W, suitable for flame proof bulk head fitting 240 Volts Make: Philips/Havells/Crompton/Orient or Equivalent
Surge arrester of capacity 10 KA, operating voltage L-N : 1400V, L-E : 1200V, N-E : 1200V, conforming to IP 67 suitable for LED 150 Watt flame proof flood light as per existing make or equivalent
LED tube rod 1x20w,230 V, 4 feet, with extruded aluminium housing including holder suitable for flame proof fitting complete all as specified.
Flameproof/weatherproof (FLP/WP) switch 16 Amp, 250V single pole ON/OFF rotary type with termination box in LM6
Flameproof/weatherproof (FLP/WP) switch 16 Amp, 250V double pole ON/OFF rotary type with termination box in LM6
Flameproof/weatherproof (FLP/WP) switch 25 Amp, 250V double pole ON/OFF rotary type with termination box in LM6
Flame proof weather proof LED 1x20 watt tube light fixture 4 feet including LED 20W tube rod 4 feet,including integral reflector made of alluminium alloy LM6 with wire guard,bipin holders,.connector block, etc., and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size.recommended for gas/vapour group of IIA & IIB and zone 1&2 IP 65 protection surface mounted LED batten. Make: Sudhir/Shyaam or equivalent
Recess mounted asthetic LED under canopy luminarie 80W comprises of pressure die cast housing & frame with toughened glass, IP66 protection, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including anti bird spikes fixed on the light fitting complete with fixing arrangement at the site all as specified. Make: Crompton Cat Part No. LCNR-80-CDL (Neptune I) or equivalent in philips/havells/orient
S & F modular switch piano flush single pole one way 6 amps 230 volts, complete all as specifed
S & F modular switch piano flush single pole one way 16 amps 230 volts, complete all as specifed
S & F modular Socket outlet 6 amps 2/3 pin combined 2 module flush type ,230 volts ,complete all as specifed.
S & F modular Socket outlet 6/16 amps 2/3 pin combined 2 module flush type ,230 volts ,complete all as specifed.
S & F fan regulator 120 W, 2 module electronic step type ,230 volts complete all as specifed.
S & F modular metal cover plate with frame oval type size 8 module complete all as specified .
S & F modular metal flush box oval type size 8 module complete all as specified .
S & F modular metal cover plate with frame oval type size 3 module complete all as specified .
S & F modular metal flush box oval type size 3 module complete all as specified .
Supply and fixing in replacement orbit LED cylinder employ the same quality lighting and design configuration to ensure consistent colour point between luminarires within a lighting application .Available in Black and white colour option in 3000 K, Beam angle 36 degree , warm white Make: Cromptonor equivalent in philips/havells/orient
S&F in repairs LED polycarbonate cylindrical tube rod 1x20W,230V (4 feet) with inbuilt driver double sided connection, suitable for existing 4 feet batten fitting fixtures, complete with all accessories internally pre-wired complete. Make: Crompton or equivalent in philips/Havells
M/s Pankaj Enterprises
KRISHNA CONSTRUCTION COMPANY
M/S TANUSHREE CONSTRUCTION COMPANY
M/s Malinath Electricals
M/S Tanisha Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .