| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC being lowest tender reasonable | |
| 2 | L3₹20.9 L+₹37,030 (1.80%)Rejected-Finance | L3 | Rejected-Finance being not lowest | |
| 3 | L3₹21.6 L+₹1.1 L (5.38%)Rejected-Finance | L3 | Rejected-Finance being not lowest | |
| 4 | L4₹22.7 L+₹2.2 L (10.7%)Rejected-Finance | L4 | Rejected-Finance being not lowest |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
19 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GARRISON ENGINEER JORHAT, MES, JORHAT-785005
REPAIR / CLEANING OF SEPTIC TANKS, SEWAGE LINES, MANHOLES AND CONNECTED SERVICES AT MARIANI AND LICHUBARI AT JORHAT MIL STN UNDER GE JORHAT.
2021_MES_497102_1
8045/E8
Open Tender
Civil Works
Item Rate
334 days
JORHAT-05
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE JORHAT
₹36,000
Yes
14 Mar 2022
23 Dec 2021
20 Jan 2022
23 Dec 2021
19 Jan 2022
6 Jan 2022
26 Dec 2021 - 29 Dec 2021
90 days
Amount
NOTES :(i)The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Dismantling PVC ( SWR) pipes of bore upto 110 mm with all fitting ,fixed at any position etc complete all as specified and directed.
Demolition and breaking up 100 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar etc complete all as specified and directed.
Demolition and breaking up 150 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar etc complete all as specified and directed.
Demolition and breaking up 200 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar etc complete all as specified and directed.
Demolition of brick masonry built in cement sand mortar including all quoins, arches, pillars , etc complete all as specified and as directed.
Demolition of cement concrete ( un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing debris to a distance n.exc. 50 m etc complete all as specified and as directed.
Demolition of Reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position and removing debris to a distance n.exc. 50 m etc complete all as specified and as directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
Excavation in trenches n exc 1.5 mtr wide and depth n exc 1.5 mtr deep for foundation, etc n exc 10 sqmtr on plan, in soft/loose soil and getting out complete all as specified and directed.
Removing excavated materials (soil) n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
M&L for PCC (1:4:8), type D2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for Brick work with sub class‘B’ bricks,old size ,well kiln burnt , straight or curved on plan exc 6m mean radius, built in cement sand mortar 1:6 etc complete all as specified and as directed.
M&L for Brick work with sub class‘B’ half bricks,old size ,well kiln burnt , straight or curved on plan to any radius, built in cement sand mortar 1:4 etc complete all as specified and as directed.
M&L for providing cement concrete (1:2:4) type B1 ( using 20mm graded stone aggregate) as in copings, benching to manholes,water troughs and the like including weathering slighty rounded or chamfered angles and throating, and including necessary form work complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
Material and labour for Precast Reinforced Cement Concete slab type M-20(Nominal Mix) using 20 mm graded stone aggregate, set in Cement Mortar (1:4) complete all as specified and as directed.
Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tile exceeding 0.06 Sqm and not exceeding 0.11Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed layer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed.
Material & Labour Glazed ceramic tiles 450x350x7 mm(Coloured) on vertical surfaces such as skirting, dados and riser to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete over 10mm thick screed bed vertical layer in CM (1:4)all as specified and as directed.
M&L for Rendering 15 mm thick, cement plaster, in cement sand mortar (1:6),on fair faces of brick work , finished plaster surface even and smooth without using extra cement etc complete all as specified and directed.
M & L for Rendering 15 mm thick on brick wall or concrete surface in cement mortar1:4 mixed with WPC( @ as per manufaturers instruction) finished even and smooth without using extra cement, complete all as specified and as direted. Note : WPC shall be measured and paid seperately under relevant item.
M&L for Rendering 15 mm thick, cement plaster, in cement sand mortar (1:4),on fair faces of brick work , finished plaster surface even and smooth without using extra cement etc complete all as specified and directed.
Supply only integral liquid water proofing compound of best quality complete all as specified and as direted.
S&F in repair Vitreous China wash down (EWC) water closet pan (pedestal pattern), white (excluding flushing cistern and flush pipe) but including plastic water closet seat cover closed pattern with flat bottom and cover with PVC hinge device, fixing bolt for pedestal pattern complete all as specfied and directed.
S&F in repair Vitreous china squatting pan of Orissa Pattern of size 580x 440 mm white with ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC type E2 ( using 40 mm graded crushed stone aggregates), 1:5:10 and finishing the top surfaces to match with the existing flooring complete all as specified and as directed .
S&F in repair PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32 mm PVC flush pipe of required length and making connections complete all as directed by Engineer-in-Charge
S&F in repair Vitreous china wash hand basin, white, flat ball type , size 550 mm x 400 mm including bracket, cutting for and pinning the ends of brackets or erecting stands also including brass chromium plated waste coupling 32mm dia, PVC flexible waste pipe 40 / 32 mm dia of suitable length and PVC connection 15mm size 450mm length with PTMT nuts, complete all as specified and as directed .
S&F in repairs PVC water closet seat cover, white / black, with mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S & F in repairs 32 mm waste coupling CP for kitchen sink including waste pipe fixed complete all as specified and as directed.
S & F in repairs for 15mm size PVC connection pipe with PTMT nut of length 450mm complete all as specified and directed.
S&F in repair of 15 mm size bib tap standard fancy type of PTMT, any colour high pressure screwed for iron pipes (minimum weight 105 gram) complete all as specified and directed.
S & F 15 mm size Pillar tap fancy type of PTMT, any colour high pressure screwed for iron pipes (minimum weight 120 gram) complete all as specified and directed.
S & F 15 mm size Stop valve fancy type of PTMT, any colour high pressure screwed for iron pipes (minimum weight 90 gram) complete all as specified and directed.
S&F Glass Shelf assembly 600 mm long and 150mm wide with side railing fixed to walls with wooden plugs with chromium plated brass screws and cup washers complete all as directed.
S&F in repair chromium plated (health faucet) 1.25 m tube ABS with and hook completed all as directed.
M&L for cutting into existing manholes for connecting (100mm dia sewage) new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1(using 20mm graded stone aggregate) smooth finished, and reforming benching as required complete all as specified and as directed.
M&L for cutting into existing manholes for connecting (150mm dia sewage) new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1(using 20mm graded stone aggregate) smooth finished, and reforming benching as required complete all as specified and as directed.
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia(annealed) or securing with clips complete all as specified and as directed.
M&L for mild steel TMT Fe-500D bars 10 mm dia and over , cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia(annealed) or securing with clips complete all as specified and as directed.
Supply, laying and testing of 150 mm internal diameter of double wall corrugated(DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS-16098-2013 part-2 complete all as specified and as directed.
Supply, laying and testing of 200mm internal diameter of double wall corrugated(DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS-16098-2013 part-2 complete all as specified and as directed. Make :- Rex Polyextrusion Pvt Ltd/Jain Irriogation Systems Ltd/ Alom Poly Extrusions Limited .
Supply, laying and testing of 100mm internal diameter of double wall corrugated(DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS-16098-2013 part-2 complete all as specified and as directed.Note item no 43 to 45 Make :- Rex Polyextrusion Pvt Ltd/Jain Irriogation Systems Ltd/ Alom Poly Extrusions Limited Bedding of pipe shall not be provide in normal condition and CONSTRUCTION METHODS shall be strictly compiled as per clause no A-4 of ANNEX 'A' of IS 16098 part-II .
M&L for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes 150 mm bore, including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified and as directed. Note:- Thickness of PCC bed 10 cm and width of PCC bed shall be outer dia of pipe plus 30 cm.
M&L for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes 100 mm bore, including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified and as directed. Note:- Thickness of PCC bed 10 cm and width of PCC bed shall be outer dia of pipe plus 30 cm.
M&L for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes 200 mm bore, including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified and as directed. Note:- Thickness of PCC bed 15 cm and width of PCC bed shall be outer dia of pipe plus 30 cm.
Taking out deposited mud, silt, waste etc. from drains or channels width of bed not exceeding 60 cm and removing from site to a distance 50 metre and deposited where directed at a level not exceeding 1.5 metre from the starting point complete all as specified and as directed.
Material, T&P and labour for Cleaning of sewage line of any dia/bore including manhole using the cleaning devices and removing blockage if any and removing the waste outside MD land etc complete all as specified and as directed.
Material, T&P and labour for Cleaning of blockage of wash basin, floor trap, nahani trap, gully trap (GT), kitchen, bath etc. (carrying sludge) in any length upto the first manhole by any means (using chemical or any mechanical device) & flushing with water complete all as specified and as directed.
Material, T&P and labour for Cleaning of blockage of WC/Urinal (carrying soil waste) in any length upto the first manhole using the cleaning devices and removing blockage if any complete all as specified and as directed.
Material, T&P and labour for cleaning/de-slugging by removing semi solid sludge from Septic tank/soakwall of upto 25 users of any depth manually or mechanically in foul condition and removing the same to a distance n.exc 200m away from the starting point and depositing in pit n.exc 10 Sqm on plan and near 1.50m in depth, covered by ordinary soil to a distance n.exc 200m away from the starting point and depositing in pit n.exc 10 Sqm on plan and near 1.50m in depth, covered by ordinary soil to a thickness not less than 30 cm from the existing ground level including sprinkling of bleaching powder @ 1.20 Kg per Sqm over the filled sludge complete all as directed.
All as per item No.53 here in before but 26 to 50users.
All as per item No.53 here in before but 51 to 100users.
All as per item No.53 here in before but 101 to 150 users.
All as per item No.53 here in before but 151 to 200 users.
All as per item No.53 here in before but 201 to 250users. Notes For item no 50 to 58:- The bidder / contractor shall be executed above works i.e “cleaning/de-slugging by removing sludge from Septic tank/ soakwell etc as per provision/ direction mentationed in THE PROHIBITION OF EMPLOYMENT AS MANUAL SCAVENGERS AND THEIR REHABILITATION ACT, 2013. Accordingly bidder should quoting their offer as per above provesion and nothing shall be paid extra in this account in futture.
S&F 110 mm bore uPVC (SWR) pipe single socketed, in any length with rubber ring joint laid in floor / wall with stack clamps made out of 50 x 5 mm flat iron and nuts etc complete all as specified and directed.
S&F 75 mm bore uPVC (SWR) pipe single socketed, in any length with rubber ring joint laid in floor / wall with necessary stack clamps made out of 50 x 5 mm flat iron and nuts etc complete all as specified and directed.
Supply and fix in repair PVC (SWR) floor trap, plain with grating 75 mm outlet dia including jointing with solvent cement complete all as specified and directed by Engineer in charge.
Supply and fix in repair PVC (SWR) multi floor trap, plain with grating 75 mm outlet dia including jointing with solvent cement complete all as specified and directed by Engineer in charge.
S&F in repair for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and directed
S&F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, fixed to walls incuding mild steel clamp @ 1metre C/C complete all as specified and directed by Engineer- in- charge .
S&F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S&F UPVC bends with inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
M&L for preparation of new or previously untreated surfaces of wall and applying three coats of white wash etc complete all as specified and as directed by Engr in Charge.
S&F in repair 75 mm outlet dia Cast iron floor trap, with CI grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer- in- charge
S&F 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches etc complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) branch piece,single (single Y) equal or unequal etc complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) branch piece,single (single Y) equal or unequal etc complete all as specified and directed.
S&F in repair PVC ( SWR ) vent cowls 75 mm etc complete all as specified and directed.
S&F in repair PVC ( SWR ) vent cowls 75 mm etc complete all as specified and directed.
Disconnecting ball valve with float arm from RCC service water tank of capacity n.exc. 500 liters , empting stored water through wash outlet, cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, cleaning the internal surfaces by rubbing with markin cloth etc and finally washing the internal surfaces with bleaching powder, closing wash outlet, refixing ball valve in proper position, closing the top cover including minor repair if required and testing complete including writing letters 250mm height as "Cleaned on: _____(Date)" in stencil on outer face of tank with white paint complete all as directed.
S&F in repair PVC cover ( lid ) of water storage tank for capacity 500 to 1000 ltrs etc complete all as specified and as directed.
S&F 20mm bore dia ball brass valves, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed including taking out old unserviceable one etc complete all as specified and directed.
Disconnecting ball valve with float arm from PVC service water tank of capacity n.exc. 300 liters , empting stored water through wash outlet, cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, cleaning the internal surfaces by rubbing with markin cloth etc and finally washing the internal surfaces with bleaching powder, closing wash outlet, refixing ball valve in proper position, closing the top cover including minor repair if required and testing complete including writing letters 250mm height as "Cleaned on: _____(Date)" in stencil on outer face of tank with white paint complete all as directed.
All as per item No. 77 here in above but of capacity of PVC water storage tank exc. 300 litre and n.exc. 500 lirtres.
All as per item No. 77 here in above but of capacity of PVC water storage tank exc. 500 litres and n.exc. 1000 litres.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/S FRONTIER CONSORTIUM
M/S GOPAL ROY AND CO
M/S PAUL CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .