Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC AKULA STREET BHAPUR BAZAR BERHAMPUR DISTT GANJAM ODISHA 760001 | GANJAM | ODISHA | 760001 | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹41.5 L+₹2.1 L (5.43%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹42.7 L+₹3.3 L (8.37%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹43.0 L+₹3.6 L (9.18%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹43.1 L+₹3.8 L (9.54%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
25 Aug 2021, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR REPLACEMENT TO PLUMBINGS SANITARY FITTINGS FLOOR WALL TILING INCLUDING CERTAIN EM WORKS OF ARMY AD CENTRE AND AD RECORDS AT GMS UNDER GE I GOS
2021_MES_445299_2
8000/22/21-22/0921/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR ON SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹75,000
Yes
27 Sept 2021
12 Aug 2021
27 Aug 2021
12 Aug 2021
25 Aug 2021
19 Aug 2021
Amount
Taking up or down 15 mm bore steel tubing and connections including cleaning if refixing required complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning if refixing required complete all as specified and directed.
Taking up or down 25 mm bore steel tubing and connections including cleaning if refixing required complete all as specified and directed.
S&F 15 mm bore GI tubes medium grade (ISI marked) with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20 mm bore GI tubes medium grade (ISI marked) with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 25 mm bore GI tubes medium grade (ISI marked) with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.
Refixing 15 mm bore old steel tubing and connections in new or old position (wall, floor, ceiling etc) complete all as specified and directed.
Refixing 20 mm bore old steel tubing and connections in new or old position (wall, floor, ceiling etc) complete all as specified and directed.
Refixing 25 mm bore old steel tubing and connections in new or old position (wall, floor, ceiling etc) complete all as specified and directed.
S&F in repairs sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495 mm x 420 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S&F in repairs for vitreous china wash basin, white,flat back, size 550 x 400 mm with brackets, including supply & fixing pillar cock 15 mm bore CP fancy type, PVC connection of 450 mm long, PVC (HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc complete all as sapecified and directed.
S&F in repairs Water closet vitreous china squatting pan, orissa pattern size 580x440mm white with integral foot rests including flushing cistern and flush pipe including provision of lime concrete bedding complete all as specified and directed.
S&F in repairs for Vitreous China urinals, bowl type flat back size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as sapecified and directed.
S&F in repairs Wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe including plastic water closet seat, black, closed pattern with flat bottem, & cover & M S CP or aluminium hinging device, flushing cistern and flush pipe complete all as specified and directed.
S&Fin repairs PVC 10 litres capacity valveless ,syphonic action type low level flushing cistern ,white including flush pipe, cantilever brackets ,inlet, ball valve, float and handle, PVC connection 15mm dia etc complete all as specified and directed.
S&F in repairs health faucet with fluxi pipe and hand shower ,the length of hose 1.50 mt fitted to the tap complete all as specified and directed.
S&F in repairs plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
Dismantling water tanks of any description, capacity exc 500 and not exc 1000 litres and removing from site complete all as specified and directed.
Dismantling water tanks of any description, capacity exc 1000 and not exc 2000 litres and removing from site complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top)1000 litre capacity hoisted and fixed in position complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top)2000 litre capacity hoisted and fixed in position complete all as specified and directed
S&F in repair 20 mm bore Ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair 25 mm bore Ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repairs 20mm bore Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs 25 mm bore Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs 15 mm bore pillar taps cast copper alloy, with capstan head chromium plated fancy type screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repairs 15 mm bore Stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle chromium plated fancy type screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs 15 mm bore bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fancy type chromium plated complete all as specified and directed.
S&F in repair 15 mm bore brass elbows both ends screwed and fixed complete all as specified and directed.
S&F in repair 20 mm bore brass elbows both ends screwed and fixed complete all as specified and directed.
S&F in repair 15 mm bore brass union to connect iron pipe to polyethylene and fixed complete all as specified and directed.
S&F in repair 20 mm bore brass union to connect iron to polyethylene and fixed complete all as specified and directed.
S&F grating doom 125 mm dia with waste hole of PTMT (minimum weight 40 grams) complete all as specified and directed.
S&F in repairs brass chromium plated shower rose125 mm size with or without swivel joint complete all as specified and directed.
S&F CP 2 way bib cock. complete all as specified and directed.
S & F in repairs lid/cover of water tank capacity of 1000/500Ltrs including necessary cleats/clamps complete all as specified and directed.
S&F in repairs PVC waste pipe for urinal/WHB/sink complete all as specified and directed.
S&F SS toilet paper holder with flap complete all as specified and directed.
S&F in repairs Waste fittings 32 mm dia, brass, chromium plated for sinks/basins etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
Taking down of eaves gutters and rain water pipes of any size or pattern including all fittings etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore with out access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with out access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 110 mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and directed.
S&F stack clamps made out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nut and securing ends of stays to wall or roof for 100 mm bore of pipe complete all as specified and directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in sub base flooring 100 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L for Machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 Sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 20 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar mirror finished 20-25 mm thick over cement base rendering laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 15 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectagular) dark/colour shade polished,area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors over 20mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per Item No.58 above but on vertical surface of wall of size 600x600x10mm thick as in dado/skitting including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surface 200x300x7 mm thick coloured on vertical surfaces such as dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , including 10mm thick rendering in CM 1 :4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
All as per Item No.62 above but on vertical surfaces area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm as skirting complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
All as per Item No.64 above but on vertical surfaces area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm as skirting complete all as specified and directed.
M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
S & F Exterior designer tiles of size 300x300x18 to 20mm thick in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L moorum / red bajri filling in floors or pavings laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for sand cushioning including spreading in layers and rolled consolidated to thickness of 50mm (minimum) for receiving precast PCC interlocking blocks complete all as specified and directed.
S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removal of rubbish from site complete all as specified and directed.
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed.
M&L for RCC (nominal mix) 1:2:4 type B-O using 12.5 mm graded stone aggregate as in slab supported on wall,beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately.
Mild Steel TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L for rendering on other than fair faces of brick work or concrete surface of wall 15mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed.
M&L for providing precast cement concrete louvres and jallies 35 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for 30mm thick PCC 1:2:4 type B-0 using (12.5mm graded stone aggregate ) as in sunken floor mixed water proofing compound finished surface even and smooth with using extra cement complete all as specified and directed. Note : water proofing compound shall be measured seperatly.
M&L Rendering 15mm thick cement plaster in cement mortar 1:3 as in brick/concrete surface of sunken portion using water proofing compound complete all as specified and directed. Note : water proofing compound shall be measured & paid seperately
M&L wire brushing and cleaning top surface of cement concrete including flashings and junction of parapet etc. and surface painting with a layers of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq.m. blinded with grit or pea size gravel @ 0.006 cu.m. per sqm and lightly tampered (area of flashings, etc., shall be added to the roof area) complete all as specified and directed.
M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate, 75mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in the quoted rate for concrete in plinth protection.
M&L for 100mm thick PCC 1:2:4 Type B-2 using 40mm graded stone aggregate in pavement/hard-standing laid in alternative panels, surface finished even and smooth without using extra cement, including necessary form work, complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick rendering on other than fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering in CM (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement and mixed with water proofing compound complete all as specified and directed. (Note: supply only of WPC shall be measured and paid for seperately )
M&L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of cement based paint complete all as specified and directed.
S&F in repairs PVC connection 15mm size with PTMT nuts, of 450mm length complete all as specified and directed.
Taking down carefully old UNSV aluminium point wiring with wooden batten /concealed and all accessories of(light, fan, socket or power) such as switches socket ceiling rose, fan regulators, light fitting, main switches DB’s etc and making good disturbed surface complete all as specified and directed.
M&L for point wiring with cable PVC insulated but unsheathed, 1.5 Sqmm, stranded copper conductor in and including PVC conduit duly concealed continuous earthing with cable PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire and MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light/Call bell point controlled by one, one way switch.
One fan point controlled by one, one way switch.
One exhaust fan point controlled by one, one way switch.
One 5 Amp socket point controlled by one switch on independent board
One 5 Amp socket point controlled by one switch on same board
All as per Item No.95 above but with cable PVC insulated 4.0 Sq mm in and including PVC Conduit incl continuous earthing with cable PVC insulated 2.5 Sq mm copper conductor for power socket 15Amps complete all as specified and directed.
M&L for point wiring with cable PVC insulated but unsheathed, 1.5 Sqmm, stranded copper conductor in and including PVC casing caping duly fixed on walls continuous earthing with cable PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire , MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light point controlled by one, one way switch.
One fan point controlled by one switch.
On 3 pin 5 Amps socket outlet point on independent board
On 3 pin 5 Amps socket point on the same board
One light point controlled by two two way switches
All as per Item no 101 above but with cable 4 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket.
M&L for point wiring in existing conduit with PVC insulated, unsheathed, single core multistandard copper conductor cable 1.5 Sqmm, stranded copper conductor in and including PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire and MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light point controlled by one, one way switch.
One fan point controlled by one switch.
On 3 pin 5 Amps socket outlet point on independent board
On 3 pin 5 Amps socket point on the same board
One light point controlled by two two way switches
All as per Item No. 107 above but with cable 4 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket.
S&F switch socket combination 2-in-1, 5 pin 5 Amp complete all as specified and directed.
S&F switch socket outlet 5 pin 5 Amp complete all as specified and directed.
S&F switch socket combination 2-in-1, 5 pin 5 and 15 Amp complete all as specified and directed.
S & F switch piano (Flush type) 5 amps, 240 Volts, single pole one way.
S & F switch piano (Flush type) 5 amps, 240 Volts, single pole two way.
S&F modular socket 6A , 2/3 pin combined 2 module complete all as specified and directed.
S&F modular switch 6A complete all as specified and directed.
S&F modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F modular socket 6A / 16A , 2/3 pin combined 2 module complete all as specified and directed.
S&F modular 6A 1 module 2 way switch complete all as specified and directed.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC complete all as specified and directed.
S & F for for Bell push modular 6 Amps single module complete all as specified and directed.
S&F modular Ceiling rose 3 termianl complete all as specified and directed.
S&F modular white cover plate with frame for module 3 incl modular metal flush box complete all as specified and directed.
All as per Item No.126 above but for 6 module complete all as specifed and directed.
All as per Item No.126 above but for 8module complete all as specifed and directed.
All as per Item No.126 above but for 12 module complete all as specifed and directed.
All as per Item No.126 above but for 18 module complete all as specifed and directed.
S&F Bakelite Sheet cover plate of size (5x5) complete all as specified and directed.
S&F Bakelite Sheet cover plate of size (8x5) complete all as specified and directed.
S&F Bakelite Sheet cover plate of size (11x13) complete all as specified and directed.
S& F in replacement of PVC Gang box Square type for fittings complete all as specified and directed.
S& F in replacement of PVC Board box of following Size complete all as specified and directed. (4x4)
All as per Item No. 135 above but size (6x8)
All as per Item No. 135 above but size (8x10)
S&F ceiling rose, bakelite three terminal complete all as specified and directed.
S & F bell ding dong electric single phase 240 Volt. complete all as specified and directed.
S & F ceiling fan regulator electronic step type socket mounting type complete all as specified and directed.
S & F in repair LED light fitting 18/ 20 Watt T5 batten type,PVC extruded batten with decorative end caps complete with polycarbonate /glass tube 4Ft White , internally pre-wired and including connecting up with suitable twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S & F in repair of light fittings (2Ft) with wall mounted LED pattern with polycarbonate housing & integrated electronic driver of 9W cap T5(max lenght upto 600mm) complete all as specified and directed. (Note : Contractor shall submit warratny for 03 yrs)
S&F in repair LED Porch light/surface mounting downlighter type with round surface,PDC Aluminium housing light fittings of 10 W cap 3000K incl taking down the old unsv complete all as specified and directed. (Note : must for warrenty of 3 yrs to 5 yrs)
S&F in repair recess mounting LED low profile slim fit downlights with high lumin out put of 12 wats cap with celing cutout 160mm oval/round of ht 25mm complete prewired incl necessary electrical connections complete all as specified and directed.
S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 36W, sIze 2'x2' including taking down the old rusted tube light fitting complete all as specified and directed.
S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 24 W, sIze 1'x2' including taking down the old rusted tube light fitting complete all as specified and directed.
S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 24 W, sIze 1'x1' including taking down the old rusted tube light fitting complete all as specified and directed.
S&F in repair Globe Decorative wall light fixture made up of Polycarbonate,suitable for LED incl LED Bulb 10W B-22 Series complete all as specified and directed.
Supply and fix in replacement of bldg security light fitting LED type of 20 watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 luminaire with high power LEDs as light source and electronic driver. mounting bracket suitable to house the light fitting , with its Galvanised Flat Iron clamps conntected nuts bolts etc complete all as specified & directed. (Note : must for warrenty of 3 yrs to 5 yrs)
S&F in replacement of 2 Runs of cable PVC insulated but unsheathed 4.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 2.5 Sq mm, stranded copper conductor complete all as specified and directed.
S&F in replacement of 2 Runs of cable PVC insulated but unsheathed 1.5 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 1.0 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
S&F in replacement of 2 Runs of cable PVC insulated but unsheathed 2.5 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 1.5 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
S&F in replacement of 2 Runs of cable PVC insulated but unsheathed 6.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 4.0 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
S&F in replacement of 2 Runs of cable PVC insulated but unsheathed 10 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 6.0 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
S& F in replacement of 3 core 1 Sqmm round sheathed copper wire complete all as specified and directed.
S & F in replacement sheet metal enclosure vertical DBs with provision for FP MCCB frame upto 100A in 16,KA as incomer 4 way double door made complete all as specified and directed.
S & F in replacement sheet metal enclosure double door MCB DB, SPN 12 way complete all as specified and directed.
S & F in replacement sheet metal enclosure double door MCB DB, SPN 8 way complete all as specified and directed.
S & F in replacement sheet metal enclosure double door MCB DB, TPN 4 way complete all as specified and directed.
S & F in replacement MCCB 100 Amps 4 Pole 25 KA 415Volts complete all as specified and directed.
S & F in replacement MCCB 63 Amps 4 Pole 16 KA 415Volts complete all as specified and directed.
S & F in replacement TPN 40 Amps 415Volts complete all as specified and directed.
S & F in replacement TPN 63 Amps 415Volts complete all as specified and directed.
S & F in replacement MCB SPN 16 TO 32 Amp 10 KA 240 Volts complete all as specified and directed.
S & F in replacement MCB, SP 6 to 30 Amp 240 Volts rating complete all as specified and directed.
S&F in replacement exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed.
S & F in minor repairs to FTL fittings by replacing bi-pin holders, connectors , tube rods chokes of any type and capacity etc complete all as specified and directed. Note : Tube rods and chokes are measured separately
Supply only Electronic Ballast suitable for 36/40 watts FTL conventional light fittings complete all as specified and directed.
supply only Electronic Ballast suitable for 28 watts FTL conventional light fittings complete all as specified and directed.
Supply only tube rod 36/40 watt for 4 feet tube light fittings complete all as specified and directed.
Supply only tube rod 28 watt for 4 feet tube light fittings complete all as specified and directed.
S&F in replacement of single pole and neutral enclosure with a two pin and earth plug socket 240 V with one MCB SP ‘C’ series rating 20 to 30 Amp complete all as specified and directed.
M&L in replacement for earthing with galvanized steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground(earth pit not less than 2.25 mtrs deep below ground level)with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers protected with & including 15 mm dia light grade GI pipe necessary excavation and earth works, charcoal and common salt filling, watering arrangement with 20 mm GI pipe light grade including PCC pit with Pre cast RCC (1:2:4) cover, GI funnel with mesh test point, testing & commissioning complete all as specified and directed.
M/s Bapujee Builders and Traders
M/S SIWALIK AND CO
HARAGOURI SUPPLIERS
DHABALESWAR ENGINEERING WORKS
ABC CONSTRUCTION COMPANY
G.KRISHNA MURTHY AND PARTNERS
M/s MAA BHAIRABI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .