| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹21.4 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹21.8 L+₹47,182.11 (2.21%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹24.7 L+₹3.3 L (15.5%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹25.2 L+₹3.9 L (18.1%)Admitted-Finance | L4 | Admitted-Finance | ||
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹29.1 L
EMD Value
₹58,240
Closing Date
30 Jul 2026, 4:00 pmClosed
Er. Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2026_PWDJK_317068_1
e-NIT No. EDJ/ 63 of 2026-2027 Dated 21-07-2026
Open Tender
Electrical Works
Percentage
Billawar
please refer to NIT
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB Electric Div Jammu
₹58,240
6 Aug 2026
21 Jul 2026
31 Jul 2026
22 Jul 2026
30 Jul 2026
22 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply,Installation,Testing and Commissioning with transportation at site of 1 No. 11 mtr High Mast Pole suitable for 6 Nos. Luminaries installation symmetrically alongwith junction box, cross arm/ suitable ring for Luminaires including foundation accessories. The High Mast pole shall have an intigral power tools installed inside the base compartment for the operation of luminaires. Wiring with 3 x 2.5 sq.mm PVC insulated copper conductor from junction box of pole to luminaires alongwith installation charges includes in the mast supply price. The erection of pole with all accessories shall be with the help of suitable equipment or with help of modern engineering practice. The specifications of pole is as under. Length Section Bottom 5.6 Mtr. Middle 2.7 Mtr. Top 2.7 Mtr. Outside Diameter. Bottom 165.1 x 4.50 mm. Middle 139.7 x 4.50 mm Top 114.3 x 3.65 mm | |||||
| 1.01 | Approx. weight of Pole 147 Kgs.
Base Plate 600 x 600 x 8mm
Tensile Test - Tensile Strength 540 Mpa (55 Kgf/Sq.mm). And with Technical Parameters as
Physical Requirement The material when tested in accordance with IS: 1894:1972 shall have minimum tensile strength of 42 Kgf/mm and confirming IS 1894: 1972.
Protection Against Corrosion. The poles shall be coated with black bituminous paint confirm to IS 158-1968 throughout internally and externally upto the level i.e 1/6 of the total length which goes inside the earth.
Tolerance. Outside diameter of poles as nearly circular as possible and their diameter shal l not vay by more than 1%.
Earthing. Nut 10 mm dia shall welded on pole at the height of 400 mm from planting depth. The job including provided & fixing of 3C x 2.5 sq. mm copper cable also. | - | - | - | - |
| 1.02 | Steel should be of good quality of weight 7.85 g/cum factor of safety on cripplilating load 2 and factor of safety on breaking load is 2.5 size of the base plate duly welded at bottom. The mast shall have 6 No 32 mm dia wholes at 2.54 above the base plate suitable to accommodates 6 to 8 Nos. of 3 core x 2.5 sq.mm Cu conductor cables from control panel to luminaries dia of adjustable ring = 1800mm dia of the steel pipe of the ring =50 mm6Nos. of support of 50mm dia pipe duly welded between inner periphery of the ring and the cap. The pole is to be errected in c. concretc in the ratio of 1:2:4 mix. The fondation is to be continued upto 2' above groung level in square/round shape. The length and diameter of the cap of the adjustable ring is such that showed be well fixed in top of the mast and give an overall aesthetic look to the mast. The cap of the ring shall have 6 Nos. holes welded suitably with 6 Nos. nuts to facilitate tightening of the top of the mast. | 16 | Nos. | 50,000 | ₹8,00,000 |
| 2 | Supplying, installation, Testing & Commissioning of 150 watt Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50
deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As
per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall
be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). | 98 | Nos. | 7,035 | ₹6,89,430 |
| 3 | Suplly Installation, testing and commissioning of the MAIN CONTROL PANNEL double door Outdoor type cubical of size (LXBXH)(2'X1'X2.5') WITH FOUR LEGS AND 1 FEET ABOVE GROUND LEVEL,16 SWG sheet steel Powder coated including , MCCB 63 A 1 NO. , 1 NO., Ammeter AND 1NO. Voltmeter 6 no. single pole mcb, 1no. SPN 63 A, phase indicators,Digital timer along with locking arrangement , provided with 1kva servo of make:- power control electric/electric field/ isi marked and all the accessories are made up of make:- schinder electric,Havels,Anchor. And writing words/alaphabets with synthetic enamel paint (As per direction of Engineer Incharge) | 16 | Nos. | 48,000 | ₹7,68,000 |
| 4 | Supplying,Testing,Laying and making indoor end termination with aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 16 Sq. mm 2 core) | 882 | Mtrs. | 313 | ₹2,76,066 |
| 5 | Supply Installation, Testing & Commissioning of 3 Core Power Cable 1.5 sqmm for internal connection between Flood light and Pannel. | 840 | Mtrs. | 170 | ₹1,42,800 |
| 6 | Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover. | 16 | Set | 13,200 | ₹2,11,200 |
| 7 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 78 | Mtr | 70 | ₹5,460 |
| 8 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 80 | Mtr. | 244 | ₹19,520 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_1037266.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .