Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC RIDMALSAR PUROHITAN BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L1 | Accepted-AOC lowest | |
| 2 | L2₹14.4 L+₹1.8 L (14.2%)Rejected-Finance 17 A KRISHNA SQUARE II NEAR GURUDWARA AMRITSAR | AMRITSAR | AMRITSAR | PUNJAB | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹15.7 L+₹3.1 L (24.2%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹15.8 L+₹3.2 L (25.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹16.7 L+₹4.0 L (31.9%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹14.6 L
EMD Value
₹29,100
Closing Date
17 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF AMRITSAR
ASST. GARRISON ENGINEER (I) AIR FORCE STATION AMRITSAR- 143001
PROVN OF AHED BETWEEN SNCOS MESS, SNCOS LIVING IN ACCN AND SNCOS MESS CORRIDOOR FOR UNIT GATHERING AT 41 WEU (A) KHASA UNDER AGE (I) AF AMRITSAR
2023_MES_619538_1
AGE (I) AF/ASR/T-22/2023-2024
Open Tender
Civil Works
Item Rate
210 days
AGE (I) AF AMRITSAR
CLASS E AND CATEGORY a(i) and b (i)
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF AMRITSAR
₹29,100
Yes
29 Dec 2023
19 Sept 2023
24 Oct 2023
19 Sept 2023
17 Oct 2023
3 Oct 2023
Amount
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M & L for coloured non skid/matt finish ceramic tiles, 7 to 8 mm thick, (square/ rectangular), area of each tile exceeding 0.11 sq.m but not exceeding 0.18 sq.m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of 15 mm thick cement mortar (1:6) complete all as specified and directed.
Ditto all as per item No 2 above but as in dado, riser & skirting over & incl 10mm thick rendering in CM 1:3
M&L for PCC 1:4:8 Type D-2 using 40 mm aggregate in foundations, filling and mass concrete all as specified and directed by EIC.
M&L Brick work with sub class "B" bricks, straight or curved on plan exc 6 m mean radius , built in CM 1:4
M&L for Rendering 15mm thick in cement mortar 1:6 on brick or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L 15 mm thick cement plaster in cm 1:4 mixed with liquid water proofing compound @ of 2% as on other than fair face of brick or concrete surface finished surface even and fair all as specified and directed Note : Supply only water proofing liquid shall be measured and paid separately.
Supply only liquid water proofing compound to mixed with cement mortar etc complete all as directed.
M&L and fabrication of mild steel work as in posts,purlins,crane gantires, rafter ,rails,wind tie nut & bolt etc and fasteningsetc and heavy brackets framing (MS tube, beam,tee,angle,channels,flat section etc and other sections) including distance pieces,cleats etc Fe-290 (Gde E165) complete all as specified and directed .
M&L and fabrication of mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
S & F Plain, galvanised, mild steel sheeting 0.63 mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275
M&L for PCC 1:3:6 Type C-1 Cement concrete in foundations, filling and mass concrete all as specified and directed by EIC.
M&L two coats of synthetic enamel painting on new steel surfaces of any description over 10 cm in width or girth not otherwise described including prepration of previously untreated surfaces all as specified and directed by EIC.
M & L Reinforced cement concrete (nominal mix) type B1 (1:2:4) using 20 mm graded aggregate in Columns, pillars, piers, posts and struts etc
M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter ®
TMT bars 10 mm dia and over , cutr to length , bent to shape required , including cranking , benidng spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirmin to
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L and fabrication of mild steel work in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete.
Anodised aluminium snap grid frame work for false ceiling all as specified and directed by EIC.
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L for 6-8 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified. Make : (i) Aluminum section : VALCO, HINDALCO, JINDAL (ii) Gypsum board :- GYPSUM INDAI Ltd/LA GYP ECO Board.
Excavating in post holes( or similar holes) each n exc 0.5 cu.m. getting out, returning,filling in and ramming earth of broken rubble mixed with earth around , in layers not exceeding 25 cm, watring, and removing surplus soil to a distance n.exc 50 m and making good surface
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Hard / Dense soil complete all as specified and as directed.
Returning,filling in trenches including spreading watering and well ramming in layers not exc 25cm thick in soft.loose soil complete all as specified and as directed .
Removing excavated materials to a distance not exc 50m and depositing where directed by EIC at a levlel not exc 1.5 m above the starting point.
Material and labour in repair for Point wiring for One light point, controlled by one switch 5 Amp one-way complete with 1.5 Sq mm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including PVC concealed conduit (medium quality) and conduit fittings including 1.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly including MS sunken box covered with 3mm thick bakelite laminated sheet top cover and machine made brass screw and washers etc complete all as specified and directed:-
(a) For one light/fan/bell point controlled by one 6 Amp one way switch.
(b) All as per item No. 1.1 hereinbefore but wiring for one 3 pin 6 Ampere socket outlet point on the same board, controlled by other switch complete all as specified and directed.
S & F of in repair switch piano flush type single pole one-way 6 Ampere complete all as specified and directed.
S & F in repair of 6 Ampere socket outlet flush type, multi purpose suitable for 2 and 3 pins (Total 5 Pins) complete all as specified and directed.
S & F in repair of ceiling rose, surface bakelite, 65 X 50 mm, 3 terminals complete all as specified and directed.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd heavy duty 230 volts complete all as specified and dircted.
Supply and fixing LED tube light fitting 1x20 watts Aluminum housing and milky diffuser with PVC insulated flexible copper cable from ceiling rose to tube light fitting complete all as per specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver,holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. complete all as per specified and directed.
M&L for sub main wiring two single core 6 Sqmm(nominal area) multi-strand copper conductor FRLS PVC insulated and unseathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standerd fittings, concealed including one run of continous PVC insulated stranded copper conductor FRLS cable 4 Sqmm for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed. Note:- Rate quoted shall be deemed to include cutting chases for concealed conduit and making good incement mortar(1:4) or PCC (1:2:4)
S & F in repair sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 8 ways including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed sunk/flush to the wall or niche complete all as specified and as directed including necessary brick work and plaster to match with the existing surface complete all as specified and directed.
S & F in repair MCB DP, 240 Volts, B curve, 10 KA, 40 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed
S & F in repair MCB single pole, 240 Volts, B curve, 10 KA, 6 to 32 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed
Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.3 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade GI pipe,funnel,wire mesh.concrete 1:3:6 type C-1 for pit and RCC pit cover. PCC pit shall be provided 50 cm away from earth pit and not on the earth pit itself. The extra cost of the water- ing pipe,bends,elbows shall be included in the unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm. The desired value of earth resistance should be less than 3 Ohm, if not found below 3 Ohm the complete earthing will be redone without extra cost of the govt. Complete all as specified and directed by Engr-in-Charge.
Supply , laying jointing and commissioning, LT under gound cables XLPE insulated screened PVC bedded galvanized steel strip armoured electric powder cable (heavy duty) with alumininum conductor cross sectional are 10 Sqmm 2 core LT, 1100 volts grade , laid in trenches , along poles or passing with through pipe or laid under floor or through/ on walls etc, including taking out old cable with protection bricks and removal, complete all as specified and directed Note:- Excavation and earth work , sand cushioning, brick protection and GI pipes for protection shall be measured and paid for separtely.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cables and foundation of poles etc. and getting out complete all as spceified and directed.
Returning, filling in trenches (soil) including spreading leveling and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removal of surplus excavation soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts. Complete all as specified and directed Note: Punned down thickness (overall 18cm), shall be considered for measurement and payment.
M&L, locally available , sub class 'B' bricks (old size) laid flat and dry in trenches over the cable for protectionprependicular to the direction of cable adjacent to each other complete all as specified and directed.
M&L, GI pipe light grade 40mm dia bore for cable protection fixed to pole or under road/ pavement, complete including MS clamps, nuts, bolts etc all as specified and directed.
Note: The Total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit.
MAAN ENTERPRISES
M/s Vijay Construction Co.
M/s AKG Engineers & Contractors
kapoor and co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .