| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹1.5 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.5 Cr+₹78,026 (0.54%)Rejected-Finance H NO 411 SECTOR 4 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU | J K | 180015 | ₹1.5 Cr+₹78,026 (0.54%) | L2 | Rejected-Finance AS PER SELECTION PERFORMA ATTACHED |
| 3 | L3₹1.6 Cr+₹10.7 L (7.39%)Rejected-Finance | ₹1.6 Cr+₹10.7 L (7.39%) | L3 | Rejected-Finance AS PER SELECTION PERFORMA ATTACHED |
| 4 | L4₹1.6 Cr+₹15.1 L (10.4%)Rejected-Finance NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181221 | ₹1.6 Cr+₹15.1 L (10.4%) | L4 | Rejected-Finance AS PER SELECTION PERFORMA ATTACHED |
| 5 | L5₹1.7 Cr+₹20.6 L (14.2%)Rejected-Finance | ₹1.7 Cr+₹20.6 L (14.2%) | L5 | Rejected-Finance AS PER SELECTION PERFORMA ATTACHED |
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
5 May 2023, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone PIN-900386 C/O 56 APO
ADDITION / ALTERATION TO MD ACCN AT NAGROTA MIL STN
2023_MES_587306_1
87913-A/E8
Open Tender
Civil Works
Item Rate
365 days
Nagrota
As per NIT
8 documents required · 8 mandatory
₹2,000
GE Nagrota
₹3.0 L
Yes
27 Jun 2023
28 Mar 2023
12 May 2023
28 Mar 2023
5 May 2023
25 Apr 2023
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm eachand n exc 4 sqm and removing from site complete all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided complete all as specified and directed.
Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc, complete all as specified and directed.
Pressed steel frames of size 125mm x 60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, hinges, lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate, complete all as specified and directed.
Pressed steel frames of size 105mm x 60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, hinges, lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate, complete all as specified and directed.
Solid PVC Door Frames of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
100mm long butt hinges (medium weight) colled rolled mild steel complete all as specified and directed.
75mm long butt hinges (medium weight) colled rolled mild steel complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue ,anodised ,with hard drawn steel spring ,fixed in floor overall length of cover plate 140mm complete all as specified and directed.
Extruded aluminium alloy handles fabricated type anodised of size 125mm long 12mm dia complete all as specified and directed.
MS 300 mm ordinary rat rails rod pattern springs including roller and roller plate complete all as specified and directed.
Mild Steel Hold fast/clamps stay for rain water pipes etc confirm to Fe-290 Gde E 165 complete all as specified and directed.
Magic eye with magic glass of all as spd and directed steel body complete all as specified and directed.
Hasp and staple Alumnium anodised lncluding bolt to hinges plate 100mm size complete all as specified and directed.
250mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
Aluminium anodized 150mm long barrel tower bolt of extruded section and fixed complete all as specified and directed.
Factory made box type steel windows with double shutters ( inside for wire mesh & outside for glass) including guard bars, hinges, steel handle, tower bolt and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and shown on drawing No. CEUZ/TD/1517/15 sheet 1/3 to 3/3.
Factory made box type steel ventilators top hung with double shutters ( inside for wire mesh & outside for glass) including guard bars, hinges, steel handle, tower bolt and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and shown on drawing No. CEUZ/TD/1517/15 sheet 1/3 to 3/3.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheetto be fitted in the MS frame welded/sealed to the styles and rails with suitablePVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawings complete all as specified and directed.
35mm thick 2nd class hard wood (Sal / Hollock) rail and style plain framed, factory made paneled shutter (one panel) without interlocking rail and 12mm veneered particle board with commercial veneering on both faces the size of rail and style as per IS -1003 (Pt-I)kiln seasoned and chemically pressure treated complete all as specified and directed complete all as specified and directed.
30 mm thick, 2nd class hard wood (Sal / Hollock), glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified and directed.
19mm thick solid PVC board prelaminated one side vinereed and other side plain as in cupboard shutter,shelves, partitions and kitchen cabinets ( Board must be water proofing ,termite proof) complete all as specified and directed.
Block boards 18/19mm thick, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame work complete all as specified and directed.
Galvanised mild steel wire cloth 0.45mm nominal dia of wire and average width of aperture 1.18mm dia and fixed with tinned tacks or galvanised mild steel staples complete all as specified and directed.
Sheet glass 3mm thick ordinary quality and glazing with oil putty in square n exc 0.5 Sqm.in each pane complete all as specified and directed.
All as per item No 30 but 4mm thick figured glass complete all as specified and directed.
Curtain rod 25mm dia aluminum brass polished with ends bulbs rings of required size including bracket complete all as directed. Make : Vista/lever ( golden colour) complete all as specified and directed.
Brick work with sub class “B” bricks (using old size bricks) straight or curved on plan exc 6M mean radius build in cement motar 1:6 using all as specified complete all as specified and directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement motar 1:6 finished even and smooth without using extra cement ( internally) surface other then complete all as specified and directed.
Rendering 15mm thick on surface other than fair faces of brick work or concrete surfaces in cement motar 1:4 finished using water proofing compound as per manufacture's instruction, ( WPC to be paid measured and seperately as supply only) even and smooth without using extra cement ( Externally) complete all as specified and directed.
Rendering 5 mm thick in cement motar (1:3) on ceiling finished even and smooth without using extra cement including three coat of white wash on ceiling including preparation of surface complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Providing 10mm thick cement plaster in cement motar 1:4 on parapets over roof and finished surface even and smooth without using extra cement including taking down old plaster complete all as specified and directed.
Roughening surfaces of old concrete surfaces of any description over damaged surfaces irregular fascia, chajjas and in similar work and also for narrow width etc and rendering dubbing coat 15mm thick cement plaster in cement motar (1:4) over a coat of cement slurry @ 3.00 Kg/Sqm making surface even followed by 05 mm thick rendering in cement motar (1:3) finished even & smooth without using extra cement complete all as specified and directed
Applying two coats of synthetic enamel paint on steel surfaces over a coat to red oxide primer any description, not otherwise described over 10 cm width or girth complete all as specified and directed.
Applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description, not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of wall putty 3mm thick on plasterd surfaces complete all as specified and directed.
Complete removal of existing treatment on wall and applying two coats of oil bound distemper over a coat of wall putty 3mm thick on plasterd surfaces complete all as specified and directed.
Preparing newly plastered surfaces of walls and applying two coats of exterior emulsion paint (wheather coat proof) over a coat of Primercomplete all as specified and directed.
Material and labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm / litre and UV resistance as per IS - 15489:2004, Alkali & fungal resistance, dirt resisitance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 Sqm over old wall surfaces including complete removal of existing treatment on wall all as specified and directed.
Two coat of white wash on newly /old plastered surface on wall including preparation of surface complete all as specified and directed.
Preparation of new plastered surfaces of ceiling and applying two coat of white washing, complete all as specified and directed.
Preparation of old plastered surfaces of ceiling and applying two coat of white washing, all as specified complete all as specified and directed.
Non skid coloured ceramic tiles (Joint free) 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor jointed in neat cement slurry and pointed with coloured cement to match over and including 15mm thick Screed bed or bedding in cement motar 1:4 including Roughening of existing floor surfaces complete all as specified and directed layer.
Non skid coloured ceramic tiles (Joint free) 7 to 8 mm thick as in vertical surface, and jointal in cement slurry and pointed with white 02 coloured cement to match the shed of tile over and including 10mm thick with cement plaster in cement motar (1:4) complete all as specified and directed.
Machine cut kota stone flooring 18-20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) (Each stone not less than 55 cms x 55 cms) over and including 15mm thick screed bed in cement motar ( 1:4) as in floor finished rough including roughening of existing surfaces by picking and removing debris/unwanted material and applying a coat of cement slurry @ 03 Kg/Sqm of surface complete all as specified and directed.
Machine cut kota stone slab 18-20mm thick in skirting, dado and pillar laid and riser /tread of stair case size (0.90-1.00x 18-25cm) jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) over and including 15 mm thick rendering in CM ( 1:4) including taking out of existing dodo complete all as specified and directed.
Coloured chequered cement concrete tiles 20cmx20cmx25mm thick set jointed and ponted in neat cement slurry in floor jointed and pointed with grey cement and pigment including screed bed or bedding layer of mortar 15mm thick in cm in 1:4 complete all as specified and directed
40mm thick PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
62 cm wide Udaypur green stone 15 to 18 mm thick. (table rubbed and polished) as in cooking plateform of size not less than 2 m in length, incl cutting for sink over and including 20 mm thick screed in cement motar 1:4 including roughing of existing surface and applying a coat of cement slurry @ 03 Kg/Sqm of surface and pointing with white cement 1:2 using marble dusts admixture of pigment to match complete all as specified and directed.
All as per srl item No. 55 here -in-before but of size 550x 75 - 100mm (as on edges of cooking plateform complete all as specified and directed.
Non-skid coloured tiles 400x400x7mm thick as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed or bedding layer of cement motar 1:4, 15 mm thick over complete all as specified and ditected.
25mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as a sub base to receive topping layer finished even and rough complete all as specified and directed.
450mm x 300mm x7mm thick coloured glazed ceramic tiles as on walls/ vertical surfaces over including and 15mm cement rendering in cement mortar 1:4, complete all as specified and directed.
PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in benching, coping etc and similar items including weathering slightly rounded or chamfered angles and throating on top of chajjas rails cills etc.including use of necessary form work complete all as specified and directed.
M & L for PCC 1:3:6 C-2 (using 40mm graded crushed stone aggregate) as in plinth protection ( 75mm thick ) finished even and fair complete all as specified and directed.
PCC (1:3:6) Type C1 using 20mm graded crushed stone agg as in surface channel & drain incl form work complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth of cement concrete using extra cement including forms moulds, mitred/ stopped ends etc, complete all as specified and directed.
Cement concrete 1:5:10 type E-2 using 40mm graded crushed stone agg as in any situation complete all as specified and directed.
RCC 1:2:4 type B-1 ( using 20mm graded crushed stoneagg) as in chajjas, shelves and similar works complete all as specified and directed.
Form work to chajjas, troughs, and similar items including edges complete all as specified and directed.
Form work to edges of concrete flats, floors and rools n.exc 20cm wide and side of RCC/PCC band in walls horizontal or sloping and similar work exc 5 cm but exc 10 cm complete all as specified and directed.
Mild steel TMT steel bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hookings ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Mild steel TMT steel bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hookings ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Framed work rolled section as in framing compound girder staging for end bars, shouldered and riveted, forged into spikes, framed guard bars, dooriron, ladders walk rails, railings, frame work for tanks, water tank,cooler frame as and the like built up from two or more beam or channel section or angles with plates stiffeners etc conforming to Fe-290grade E-165 ,complete all as specified and directed.
Rotational moulded polyethene water storage tank triple layer 500 ltr capacity hoisted and fixed in position including dismantling of existing tank and including PVC float valve 20 mm bore complete all as specified and directed.
Taking down steel tubing and connection including cleaning for refixing or removal to store bore of pipe 15mm complete all as specified and directed.
Taking down steel tubing and connection including cleaning for refixing or removal to store bore of pipe 20mm complete all as specified and directed.
S&F 20mm bore GI tubing (medium grade) with all fittings and fixed complete fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
All as per srl item No. 74 but fixing only.
15mm bore GI tubing (medium grade) with all fittings and fixed complete fixed complete to walls and ceiling or laid in floors/roofs including taking down complete all as specified and directed.
All as per srl item No. 76 above but fixing only.
Cuttings chases for concealed water tubing of concealed conduit (cutting n.exc 10 cms girth) and making good in CM ( 1:3) in brick walls complete all as specified and directed.
Supply and fix in repair Shower rose brass chrominium plated 125mm size complete all as specified and directed.
Supply and fix in repairs Cast copper alloy CP bib tap, fancy type, screwed down , screwed for iron pipe 15mm dia/ bore of pipe complete all as specified and directed.
Supply and fix in repair cast copper alloy CP stop cock /angle Valve, fancy type, screwed both ends for iron pipe 15mm dia/ bore of pipe complete all as specified and directed.
All as per item No 81 above but with long shank and cup ( concealed type).
Stop valves ,cast copper alloy ,screwed down high pressure , with crutch or butterfly handle , screwed both ends for iron pipe or for union 20mm dia complete all as specified and directed.
Towel rail 600mm long of PTMT fixed with including chromium plated brass screws and wooden/plastic cleats ( Minimum weight 190gm) complete all as specified and directed.
Dismantling cast-iron/PVC pipes including fittings taking out of trenches or walls as required dia of pipe upto 100mm complete all as specified and directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore complete all as specified and directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 110mm bore complete all as specified and directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75mm bore complete all as specified and directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 75mm bore complete all as specified and directed.
PVC (SWR) Bends any radius for 110mm bore complete all as specified and directed.
PVC (SWR) Bends any radius for 75mm bore with oval access door complete all as specified and directed.
PVC (SWR) Branch pieces single( Single Y) equal or unequal) for 110mm bore with oval access doors complete all as specified and directed.
PVC (SWR) Branch pieces single ( Single Y) equal or unequal for 75mm bore with oval access doors complete all as specified and directed.
PVC (SWR) vent cowl 75mm .
All as per item 94 above but 110mm.
PVC (SWR) floor trap with grating including jointing to waste pipe in solvent for 75mm bore including CP grating cover with or without hole complete all as specified and directed.
PVC(SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified and directed.
Vitreous china squatting pan "Orissa " pattern size 580x440mm white with integral foot rest all as fixed in repairs including ‘P’ or "S" trap including PVC low level cistern of 10 litres capacity including brackets jointing to flush pipe, PVC connection (450x15mm) flushing pipe complete fixed in repair complete all as specified and directed.
Supply and fix in repair 110 mm PVC (SWR) WC Connector with lip ring all as specified and directed.
Dismantling brick tiles or terracing tile, single layer on roof including cleaning the roof surface and filling the cracks with silicon compound if obsserved on roof complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate),50mm thick, as in padding finished even and smooth witout using extra cement all as specified and directed.
Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm including bitumen primer @ 3.5Kg/Sqm complete all as specified and directed.
APP modified membrane 3mm thick and weighing not less than 3 kg/sqm with 160 GSM/sqm, non woven polyester mat as center core reinforcement, laid with 75 mm side over lap and 100mm end over lap, the membrane has to be laid with LPG tourch and over lap sealed and finished neat over roof including a coat of bitumen 85/25 at the rate of 1.2 Kg per sqm over APP membrane complete all as specified and directed.
Cement concrete tiles 25 cm x 25cm x20mm thick machine pressed set jointed and pointed in neat cement slurry on roof over APP membrane laid over 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed.
Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and directed.
Taking down existing cement plaster of any description (sunken floor) apply a coat of cement slurry with 3.00 Kg of cement per sqm and rendering 15mm thick in CM 1:3 using water proofing compound as per manufacture instruction finished even and smooth (sunken floor/wall) ( WPC shall be measured and paid supply only) complete all as specified and directed.
Vitreous China wash basin, white, flat back, size 550 x 400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets complete all as specified and directed.
S & F in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure,screwed for iron pipe 15 mm bore fancy type complete all as specified and directed.
S&F in repair kitchen rack made out of 0.63mm thick stainless steel sheet wall mounted type with 5/6 partition of size 60 cms x 90 cms x 25 cm fixed on wooden gutties complete all as specified and directed.
S&F as in repair stainless steel sink made from AISI-304 (18/8) gde steel of 1mm over all size 688x534 bowl size 610x455x250mm complete & with following specification :- (a) Stainless steel waste coupling. (b) 02 Nos MS angle iron bracket 45cm long made out of MS angle iron 35x35x5mm (c) Waste pipe and waste coupling.
Surface excavation n exc 30cm and averaging 15cm deep in any type of soil complete all as specified and directed.
Hard core of broken bricks n exe 63 mm, deposited, spread and levelled in layers n exe 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Cement concrete type D2 1:4:8 (40mm graded crushed stone aggregate), 75mm thick finished even and fair complete all as specified and directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.
Providing and injecting chemical emulsion for Post Constructional Anti termite treatment along external wall below concrete or masonry apronn using chemical emulsion @ 2.25 ltr per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.
Treating of soil under existing floor using emulsion @one ltr per hole 300mm part including drilling and pluging 12mm dia holes with cement mortar 1:2 (to match the floors complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation etc in any type of soil complete all as secified and directed.
Removing excavated material soils n.exc 50mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Returning filling in, including, spreading, levelling, watering, and well ramming in layers not exc. 25cm complete all as specified and directed.
Cement concrete 1:4:8 type D-2 (using 20mm graded crushed stone aggregate) in foundations , filling and mass concrete complete all as specified and directed.
100 mm thick cement concrete 1:4:8 type D-2 (using 20mm graded crushed stone aggregate) in bed to drain pipes incls packing under, and haunching against the sides of pipes after they are laid and tested of bore 150mm dia drain pipe complete all as specified and directed.
Supply and fix in repairs 150mm dia Reinforced concrete pipes ,class NP-3 laid and jointed complete all as specified and directed.
Brick work with sub class `B` old size bricks straight or curved on plan exceeding 6 mtr mean radius with built in cement mortar 1:4 complete all as speecified and directed
Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slab and similar articles including necessary moulds/formwork set in cement mortar (1:6) complete all as specified and directed.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channel and drains complete all as specified and directed.
Construction of septic tank for 100 users (Brick construction) complete shown on drg No. CEUZ /TD-1202/2003 sheet -1/2 & 2/2 all as specified and directed.
Construction of soakage well (Brick construction) 3.5m dia and 4m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1202/2003 sheet 1/2 & 2/2.
Cutting into existing mn hole for connecting new drain pipes making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round 3/4 section) in cement mortar 1:2:4 typeB1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as required complete all as specified directed.
Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custedy complete all as specified and directed.
Taking down existing energy meters, keeping aside safely & refixing the same in its original position after making functional & after completion of point wiring/sub main wiring, complete, all as specified and directed by Engr-In-Charge. Note:- Small items required for fixing the electric energy meter at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
Taking down existing electric water heater any size and capacity, keeping aside safely & refixing the same to its original position after servicing of the whole geyser/making functional and after completion of wiring work, complete, all as specified and directed by Engr-In-Charge. Note: If any part found unserviceable during the refixing of water heater at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt, oiling & greasing and Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose and etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly complete all as specified for the following points.
One light point controlled by one switch 5 Amp.
One ceiling fan/exhaust fan point controlled by one switch 5Amp.
One socket out let 5Amp controlled by one switch on same board.
One socket out let 5 Amp controlled by one switch on independent board.
One bell point 5 Amp controlled by one bell push on independent board complete.
One light point controlled by two, 2way switchs 5 Amp complete all as specified and directed.
All as per item No 134 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board complete all as specified and directed.
Switch piano flush type 5 Amps single pole one way complete all as specified and directed.
Socket outlet 5 pin, 5 Amp flush type complete all as specified and directed.
Switch socket combination 3 pin 5 Amp flush type complete all as specified and directed.
Switch socket combination 2 in 1 5 pin 5 /15 Amps flush type complete all as specified and directed.
Ceiling rose 3 terminal complete PVC/Polycarbonate isolated body complete all as specified and directed.
Stepped type electronic fan regulator flush type on the phenolic laminated sheet etc as required complete all as specified and directed.
Bell push piano type 5 Amps complete all as specified and directed.
Switch piano flush type 5 Amps 2 way complete all as specified and directed.
Electric bell ding dong 230 volt AC complete all as specified and directed.
Lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) compatible complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Building security light luminaries energy saving and envirnment friendly long life LED light of 25W made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistanve of IK07, including GI bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle 120 degree, fixed with and including two nos 25x4 mm size flat mild steel clamp made to shape and suitable size nuts, bolts and washers etc including taking down of existing light fitting complete all as specified and directed.
Sheet steel meter box fabricated out of 2 mm thick CRCA sheet powder coated of size 60x60x25 cm duly compartmentalized suitable to accommodate 4 Nos Energy Meter independently. each compartment shall be provided with suitable door and 4 Nos fancy lock, complete, all as specified and directed by Engr-In-Charge incl taking out existing wooden meter box complete all as specified and directed.
Sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, earthing bar and din rail complete incl taking out existing unserviceable DB with MCBs complete all as specified and directed.
Sheet metal enclosure double door for distribution board factory made for MCB DB load link TPN 4 415 V way with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down exsing UNSV DB with MCBs complete all as specified and directed.
MCB SPN 40 A to 63 A, 10 KA 240 volts "C" series complete all as specified and directed.
MCB single pole 5 to 32 Amps, 10 KA, 240 volts "C" series complete all as specified and directed.
MCB single pole, 63 Amp, 10 KA, 240 volts "C" series complete all as specified and directed.
MCCB 63A 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete all as specified and directed.
Sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sq mm as earth continuity conductor connected to commen earth and earth dolly complete including taking out existing unserviceable service connections complete all as specified and directed.
Earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, Jall: pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board and testing on completion complete all as specified and directed.
Deduction to be made from BOQ for Sch 'A' Part - II (Schedule of credit) Amount of Rs. 1,21,226.00 during AOC. Note: Tenderers shall not quote for this schedule.
Mehar Enterprises
M/s Mohd Ibrahim Khan
M/s Khajuria Construction Co.
M/s Sekinder Paul Sharma
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
bamral builder
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .