Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.2 L+₹1.2 L (15.4%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance L2 | |
| 3 | L3₹9.5 L+₹1.6 L (19.5%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L3 | Rejected-Finance L3 | |
| 4 | L4₹9.9 L+₹1.9 L (24.4%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹11.9 L+₹3.9 L (49.3%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹25,200
Closing Date
24 May 2021, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR OF WATER SUPPLY RAISING MAIN OF DI CI GI PIPE LINES VALVES FIRE HYDRANTS CENTRIFUGAL AND SUBMERSIBLE PUMP RO PLANTS CLEANING OF OH AND UG SUMPS AT 56 ASP FARIDABAD
2021_MES_439872_1
GE (FBD)/AF-15/2021-2022
Open Tender
Civil Works
Item Rate
180 days
AF STATION FARIDABAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹25,200
Yes
15 Jun 2021
4 May 2021
26 May 2021
4 May 2021
24 May 2021
11 May 2021
5 May 2021 - 10 May 2021
Amount
Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of pipe line complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking up or down in repairs the following sizes of bore dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. (a). 100 mm bore
All as per itme No 4 above but 80 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per itme No 4 above but 50 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per itme No 4 above but 40 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per itme No 4 above but 25 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per itme No 4 above but 20 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per itme No 4 above but 15 mm borecomplete all as specified and directed by Engineer-in-Charge.
Refixing old steel tubing 50 mm bore size and connections in old position complete all as specified and directed by Engineer-in-Charge. (walls,ceiling,floors,etc)
Refixing old steel tubing 40 mm bore size and connections in old position complete all as specified and directed by Engineer-in-Charge. (walls,ceiling,floors,etc)
Refixing old steel tubing 25 mm bore size and connections in old position all as specified and as directed by Engr-In-Charge. (walls,ceiling,floors,etc)
Refixing old steel tubing 20 mm bore size and connections in old position complete all as specified and directed by Engineer-in-Charge. (walls,ceiling,floors,etc)
Refixing old steel tubing 15 mm bore size and connections in old position complete all as specified and directed by Engineer-in-Charge. (walls,ceiling,floors,etc)
Supply and Laying in trenches galvanised steel water tubing ,medium grade including necessary fittings such as GI bends,Tees,Union etc complete and connecting to water supply pipe line after taking out existing old/rusted out steel tubing and connections complete all as specified and as directed by Engr-In-Charge pipe line of following sizes.:- (a) .100 mm bore
All as per item No 16 above but 80 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 above but 50 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 above but 40 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 above but 25 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 above but GI tubing all walls,ceiling,laid in floors,roof etc of size after taking out existing old /rusted out steel tubing all as specified and directed by Engr-In-Charge of following sizes:- (a) 25 mm bore
All as per item No 16 above but 20 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 above but 15 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs sluice valve cast iron body class PN 1.6 marked both ends flanged with Brass spindle and Brass check nuts with cast iron hand wheel including jointing material like rubber insulation sheet 3 mm thick,bolts ,nuts and fixed to pipe line,after and including taking out old unserviceable one complete all as specified and directed by Engr-In-Charge for following sizes.:- (a). 150 mm bore
All as per item No 24 above but 100 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item No 24 above but 80 mm bore complete all as specified and directed by Engineer-in-Charge.
Rectification of leakage in CI/DI water mains up to 200 mm bore including excavation in any type of soil (approx 2 meter length,width 1.5 meter ,deth 1.5 meter) dewatering complete by using pump set as per requirement,rectification/removing of leakage,burning out existing run lead joint /CT joint ,cutting,welding or drilling holes,clamps etc suitable for fixing of CT joint of any size complete all as specified and directed by Engineer-in-Charge. Note: CT joint/lead joint will be measured and paid under relevant item seperately
M&L Fix in repair Gun metal,globe or gate valves,with iron wheel head.screwed both ends for iron pipe and fixed after and including taking out old unserviceable one all as specified and as directed by Engr-In-Charge of the following sizes.:- (a) 50 mm bore
All as per item No 28 above but 25 mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item No 28 above but 20 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F Bib taps,15 mm bore,copper aloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule,chromium plated including after taking out old unserviceable one all as specified and as directed by Engr-In-Charge
Dismantling unserviceable old valve chambers of any size and keeping aside old materials such as CI covers,Angular iron frames and bricks etc all as specified and as directed by Engr-In-Charge
Costruction of valve chamber in PCC 1:5:8 masonry built in CM(1:4) with MS covers 3 mm thick and locking arrangement including excavaton and earth works PCC (1;4;8) type D2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15 mm thick with Cm 1:4 painting with one coat of bituminous black paint on all steel surface all as specifiedd and directed by Engr-In-Charge for the following sizes chambers :- (a) 1000 mm x 1000 mm x 1200 mm internal dimension
All as per item No 33 above but 900 mm x 900 mm x 1000 mm internal dimension complete all as specified and directed by Engineer-in-Charge.
All as per item No 33 above but 600 x 600 x 900 mm internal dimension complete all as specified and directed by Engineer-in-Charge.
Taking up cast iron water mains,80 mm bore dia (incl all fittings) with spigot and socket end and lead joint incl burning out joint complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 36 here in above but 100 mm bore dia complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 36 here in above but 150 mm bore dia complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 36 here in above but 200 mm bore dia complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of Cast iron pipes with spigot and socket ends,80 mm dia bore dia vertically cast, class B, in any length, laid in trenches all as specified and as directed by Engr-In-Charge
All as mentioned in item No 40 here in above but 100 mm bore dia complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 40 here in above but 150 mm bore dia complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 40 here in above but 200 mm bore dia complete all as specified and directed by Engineer-in-Charge.
S & F in repairs CT joint suitable for 150 mm bore CI/DI pipe including taking and after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 44 here in above but 100 mm bore dia complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 44 here in above but 80 mm bore dia complete all as specified and directed by Engineer-in-Charge.
Dismantling only centrifugal monoblock pump motor from base plate,shifting to workshop and back after repair work including fixing in it's original position,testing complete all as specified and directed by Engr-In-Charge for the following sizes: (a). 15 HP 3 phase capacity
All as per item No 47 above but 0.5 HP,1 HP and 2 HP capacity complete all as specified and directed by Engineer-in-Charge.
Opening of motor for repair/replacement of unserviceable/worn out motor bearing/ unserviceable shaft/burned out copper winding etc including re-assembling ,refixing in original position and testing complete for the following sizes all as specified and as directed by Engr-in-Charge. (a) 15 HP
All as per item No 49 above but 2 HP complete all as specified and directed by Engineer-in-Charge.
All as per item No 49 above but 0.5 HP to 1 HP complete all as specified and directed by Engineer-in-Charge.
M & L in repairs for rewinding of electric driven motor as per the existing sample,varnishing with class "B" insulation for the following sizes all as specified and directed by Engineer-in-charge, (a) 15 HP
All as per item No 52 above but 2 HP complete all as specified and directed by Engineer-in-Charge.
All as per item No 52 above but 0.5 HP to 1 HP complete all as specified and directed by Engineer-in-Charge.
S&F in repairs ball bearing of centrifugal motor after taking out broken/wornout unserviceable bearing as per sample all as specified and directed by Engineer-in-charge for the following capacity:- (a) 15 HP
All as per item No 55 above but 2 HP complete all as specified and directed by Engineer-in-Charge.
All as per item No 55 above but 0.5 HP to 1 HP complete all as specified and directed by Engineer-in-Charge.
M & L in repairs rubber coupling for 15 HP centrifugal monoblock pump after taking out old unserviceable one by removing and refixing motor for the following capacity and testing all as specified and directed by Engr-In-Charge.
Dismantling only centrifugal pump of 15 HP, 3 phase capacity from base plate,shifting to workshop and back after repair work including refixing in original position,testing complete all as specified and directed by Engineer-in-Charge.
Complete opening of 15 HP ,monoblock centrifugal pump for repair/replacement of worn out parts such as shaft,Ball bearing, bush,impellers,coupling,mechanical seal,jet assembly etc including re-assembling and refixing in position complete all as specified and directed by Engineer-in-Charge.
S & F in repairs stainless steel shaft of 15 HP,monoblock,centrifugal pump after taking out broken/wear & tear unserviciable shaft as per sample complete all as specified and directed by Engineer-in-Charge.
S & F in repairs impeller in 15 HP centrifugal pump after taking out broken/ wear & tear unserviciable impeller complete all as specified and directed by Engineer-in-Charge.
Taking out of submersible pump set of any capacity from bore well and shifting to work shop for repairing & lowering in bore well after repair work including replacement of unserviceable nuts, bolts & gaskets (depth of borewell 80m to 150m) capacity pump complete all as specified and directed by Engineer-in-Charge.
Complete opening of submersible borewell pump set of any capacity for repair/replacement of unserviciable ,worn out bearing /worn out unserviceable shaft /burned out copper winding/worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including re-assembling and refixing in original position complete all as specified and directed by Engineer-in-Charge.
S & F in repairs thrust bearing of submersible bore well motor/pump made of stainless steel complete as per sample for 15 HP capacity all as specified and directed by Engr-In-Charge.(Note:The rate of thrust pad ,thrust bearing lock nut etc are deemed to included in quoted rate) (a) 15 HP capacity
All as per item No 65 above but 10 HP capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No 65 above but 7.5 HP complete all as specified and directed by Engineer-in-Charge.
Replacement of burned out copper winding of submersible bore well motor complete by new Copper wire with existing guage and turns,varnishing with class "B" insulation for the following capacity complete all as specified and directed by Engineer-in-Charge. (a) 15 HP capacity
All as per item No 68 above but 10 HP capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No 68 above but 7.5 HP complete all as specified and directed by Engineer-in-Charge.
Taking up non clog,submersible sewage pump set,12.5 HP capacity from sewage well with all eqpts required such as chain pulley,supports,removing connections from base plate under sewage well and shifting to work shop for repairing & refixing in same position after repair work complete all as specified and directed by Engineer-in-Charge.
Opening of non clog,submersible sewage pump motor,12.5 HP,3 phase, for repair/ replacement of old unserviciable/ worn out motor bearing /worn out unserviceable shaft /burned out copper winding/ worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including re-assembling / refixing in position complete all as specified and directed by Engineer-in-Charge.
S & F in repairs impellers for non clog,submersible sewage pump,12.5 HP capacity supplied by the original manufacturer after taking out old unserviceable impeller complete all as specified and directed by Engineer-in-Charge.
S &F in repairs oil seal for submersible type,non clog sewage pump,12.5 HP capacity after taking out old unserviceable ball bearing complete all as specified and directed by Engineer-in-Charge.
Replacement of burned out copper winding of nonclog,submersible,sewage pump 12.5 HP capacity complete by new Copper wire of same guage and turns with,varnishing with class "B" insulation complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repairs PVC insulated 3 core 10 sq mm Copper multi stranded PVC sheathed submersible cable ISI marked and conforming to IS 694 and connecting submersible pump and to starter panel after taking out old unserviceable cable complete all as specified and directed by Engineer-in-Charge. Make: Havells/Polycab/Finolex
S&F in repairs MCCB 3 pole 415 volts in repairs,Fixed Thermal & Fixed Magnetic setting type, 25 Amps to 100 Amps with breaking capacity 16 KA as per sample,after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
S & F in repairs power contactors, 3 pole,18 Amps,415 volt rating all as specified and directed by Engineer-in-charge
S & F in repairs pneumatic timer block,0.1-30 seconds time delay,suitable for mounting in starter panel ,12.5 HP capacity,415 volts AC.All as specified and directed by Engineer-in-charge.Make: Havells/C&S/L&T
S & F in repair thermal over load relay,13-18 Amps range,240-440 volts complete all as specified and directed by Engineer-in-Charge. Make:Havells/C&S/L&T
S&F in repairs fully automatic star delta starter for submersible pump motor,415 Volt,3 phase,12.5 HP capacity,over load relay range 12-18 seconds,contactor size 18,standard coil voltage 260V - 415V AC,all as specified and directed by Engineer-in-charge.CAT No-IHSASANBW of Havells or equivallent .Make; C&S, Havells,L&T,
Supply and Fix in repairs Single Phasing Preventor 415 volt,3 phase ,analog type after taking out old U/S one complete all as specified and directed by Engineer-in-Charge. Model : VSP D2, Make -nilec/C&S/ABB.
Dewatering the existing U/G sump of 40000 GLNS capacity and cleaning the internal surface of sump for removing scales, funges, mud and other foreign material ,scrubbing with water using wire brush and watering the surfaces with mixture of bleaching powder and water ,finally washing with fresh water and treating with one coat of lime wash to internal wall and bottom surfaces etc complete for one time,writing in enamel paint note in in block capital letter as cleaned on (date) and due date etc,height not less than 5 cm complete all as specified and directed by Engineer-in-Charge.
All as per item No 83 above but OH cap reservoir of capacity 50000 GLNs complete all as specified and directed by Engineer-in-Charge.
M & L for painting with two coats of synthetic enamel paint over a coat of red oxide primer of on rising mains of Over head water reservoir with green colour, Distribution mains with yellow and Drainout with blue and overflow with black colour complete all as specified and directed by Engineer-in-Charge.
Dismantling the components of Reverse Osmosis plant (5000 Ltrs per hour capacity 03 Nos) and checking the serviceability of plant including rubber bushes,fittings,low pressure /high pressure motor pumps and re fixing the same after necessary repairs and replacement of unserviceable parts complete all as specified and directed by Engineer-in-Charge.
Dismantling the components of Reverse Osmosis plant and checking the serviceability of plant including rubber bushes,fittings,low pressure /high pressure motor pumps and re fixing the same after necessary repairs and replacement of unserviceable parts complete all as specified and directed by Engineer-in-Charge.
Supply and Fix Jumbo platred filter cartridge poly propyline of 10 micron to 20" complete all as specified and directed by Engineer-in-Charge.
Supply and Fix Jumbo platred filter cartridge poly propyline of 10 micron 20" complete all as specified and directed by Engineer-in-Charge.
S&F in repairs membrane filter of model 40-250 as existing size and capacity of RO plant including testing and commissioning complete all as specified and directed by Engineer-in-Charge.
S&F in repairs membrane filter of model 500-3000 as existing size and capacity of RO plant (5000 Plant per hour) including testing and commissioning complete all as specified and directed by Engineer-in-Charge.
M&L sand dual media in replacement for main RO filter complete all as specified and directed by Engineer-in-Charge.
Cleaning of RO membrane filter with citric acid and cleaning ,washing by the help of high pressure water pump complete all as specified and directed by Engineer-in-Charge.
Cleaning of RO membrane filter with citric acid and cleaning ,washing by the help of high pressure water pump complete all as specified and directed by Engineer-in-Charge.
M&L Anti scalant in 5 Ltr packing suitable for preventing formation of calcium carbonate and calcium sulphate and fouling by silica all as specified and as directed by Engineer-in-charge
S&F in repairs in repairs dual control Dozing pump,6 LPH,5.5 BAR suitable for RO plant, 250 LPH capacity as existing sample including testing and commissioning complete all as specified and directed by Engineer-in-Charge.
M & L for mixing chlorine solution 60 GPL complete all as specified and directed by Engineer-in-Charge. . Make : Aqua
S&F Water Testing Solution 500 Ml complete all as specified and directed by Engineer-in-Charge. Make : Aqua
S & F repairs Chloro Soap for chlorine plant complete all as specified and directed by Engineer-in-Charge. Make : Aqua or approved equivalent
Supply only Calcium based white to white free granular chlorination chemical decomposing at 177 C mol 112.98,Toxiicity oral rat LD 50 : 850 mg/kg in 45 Kg packing complete all as specified and directed by Engineer-in-Charge. Make:decliback or equivalent product of other manufacturers.
Supply only Alum crystal super quality complete all as specified and directed by Engineer-in-Charge.
M & L greasing for centrifugal Pumps as per sample complete all as specified and directed by Engineer-in-Charge. Make:Castrol
Servicing of decrin/liquid chlorine dosing pump,high pressure,single head gear motored dosing pump with accessories such as lead tubing connecting nuts,injection check valve, 40 Liter to 100 liter PE/FRP Tank with PE/FRP lid & Level guage and ferrules including waters piping works for inlet and out let and descaling with control switch gear complete all as specified and directed by Engineer-in-Charge.
M&L in repairs Bends up to 150 mm bore in mm (any type, radius and angle) tapers any type, (straight,bend ,increasing decreasing or double socket etc) Tee pieces single branch "Y" junction,double branch ,cross(all sockets or sockets or socket and spigot ) collars,cap and plug, complete all as specified and directed by Engineer-in-Charge.
S & F in repairs run lead joint for spigot and socket pipe and fittings ,80 mm bore, complete all as specified and directed by Engineer-in-Charge.
S & F in repairs run lead joint for spigot and socket pipe and fittings ,100 mm bore, complete all as specified and directed by Engineer-in-Charge.
S & F in repairs run lead joint for spigot and socket pipe and fittings ,150 mm bore, complete all as specified and directed by Engineer-in-Charge.
S & F in repairs run lead joint for spigot and socket pipe and fittings ,200 mm bore, complete all as specified and directed by Engineer-in-Charge.
M&L for chemical and micro biological test of water from NABL approved test lab for bore well, over head tank/UG Sump and RO plant and test report to be submitted by the contactor complete all as specified and directed by Engineer-in-Charge. as per IS-10500-2012 refers.
M&Lfor yield testing by auto/manual and utilizing hydrological process through experts of existing borewell as per his exising yield and depth of borewell at the existing site complete all as specified and directed by Engineer-in-Charge.
Saini Enterprises
M/S Anand Enterprises
laxmi enterprises
Parveen Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .