Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹29.3 L+₹1.9 L (7.04%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-Finance being not Lowest | |
| 3 | L3₹29.8 L+₹2.4 L (8.80%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance being not Lowest | |
| 4 | L4₹34.8 L+₹7.5 L (27.4%)Rejected-Finance | L4 | Rejected-Finance being not Lowest | |
| 5 | L5₹36.0 L+₹8.6 L (31.6%)Rejected-Finance | L5 | Rejected-Finance being not Lowest |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
25 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi cantt-10
GE (Central) Delhi cantt-10
CA NO GE/C-34/2021-22 PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-I AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2021_MES_463961_1
GE/C-34/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi cantt-10
₹83,000
Yes
6 Oct 2021
30 Jul 2021
27 Aug 2021
30 Jul 2021
25 Aug 2021
13 Aug 2021
30 Jul 2021 - 13 Aug 2021
60 days
Amount
M & L for mild steelas in purlin and rafter etc fixed with angle cleats or other connecting plate using Fe 290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 metre mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and directed by Engineer in Charge.
All as per item No 2 here-in-before but n cm (1:4)
M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick work firnished even and smooth without using extra cement up to hieght of four storey ,including scaffolding complete all as specified and directed by Engineer in Charge.
S & F Pre-painted galvalume aluminum Zinc coating GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer in Charge.
M&L Providing and fixing 9mm thick designer ceiling board in ceiling fixed with screws as per manufactures instructions (Make : Everest) laid on hot dipped galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be under coated white. The frame shall comprise of main runner made from 0.33mm thick galvanized steel sheet & size of 24x32x300mm and spaced at 12mm centres securely fixed to the structural soffits by approved hangers at 1200 mm maximum centres. hangers of GI wire 4mm dia to be fixed by the approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200mm long cross tee with(double stitching) to be inter locked between main runners at 600mm centre to from 1200x600mm modules cross tee longer than 600mm modules to be formed by fitting 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanized steel of size 19x19mm and 300 mm long of white colour all as per manufacturer's instruction complete all as specified & directed.
M& L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, with grey cement and pigment set, jointed and pointed in near cement slurry in floors including 15mm thick screed bedin cm (1:6) complete all as specified and directed by Engineer in Charge.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed by Engineer in Charge..
S&F,anodised aluminum frame for door with one or more rebates incl grills, jointing cleats for fixing etc complete all as specified and directed by Engineer in Charge.
S&F 50 power coated aluminium door shutters, aluminium section weighing 0.55 kg/m includingnecessary joining cleats glazing clips rubber neoprene packing handle 2 Nos in each door ,hinges aluminium anodised snap beading screws etc complete all as specified and directed by Engineer in Charge.
M & L Expahanded metal,to length,bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed by Engineer in Charge..
M&L for MS flat for roof sheets and brassing, incl securing bolt,drilling holes and washer /using ERW OR Induction butt welded ,complete all as specified and directed by Engineer in Charge.
M&L for joint less Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in CM 1:6 etc complete all as specified and directed by Engineer in Charge. .
Excavation in trenches (soft/loose soil) n exc. 1.5m wide and n exc 1.5 m in depth for foundation etc. and getting out complete all as specified and directed by Engineer in Charge.
Excavation over area in soft lose soil n. exc 3.00 m depath complete all as specified and directed by Endgineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer in Charge..
M & L for removing excavated material exc. 250m but not exceeding 500m and depositing where complete all as specified and directed by Engineer in Charge.
M & L for 15mm thick rendering on fair faces of brick work or concrete surface in cm (1:6) finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for rendering 20 mm thick in CM 1:3 on fair faces or other than fair faces of brick work or concrete surfaces firnished even and smooth with using extra cement (using WPC in cement sand mixture 1:3)
M&L for DWCPE drain pipe 200 mm dia laid in trenches, jointed and tested complete all as specified and directed by Engr-in-Charge.
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation/bed to pipe and mass concrete complete all as specified and directed by Engineer in Charge.
M & L reinforcement cement concrete 1:1.5:3 nominal mix (using 20mm graded aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and this like all as specified.
M & L for formwork to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for rough finished surface all as specified.
M&L for mild steel TMT bars 10mm dia and over cut to length,bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified
M & L RCC Type B2 1:2:4 nominal mix (40 mm graded aggregate) Ditto in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases)
Material and labour for medium duty perforated precast machine pressed drain cover slab 80 mm thick of PCC 1:1.5:3 type B-1 and 10mm TMT bars ,including flat iron 150mmx6mm all around the slab and 40mm dia hole at 100mm C/C , size of slab as required at site and complete all as specified and directed by Engineer in Charge.
M&L PCC 1: 2 : 4 type B-1 ( using 20mm graded crushed stone agg.) 50mm thick as in floor finishing surfaces of conc topping even and smooth with using extra cement complete all as specified and directed by Engineer in Charge.
All as per ser item No 26 here-in-before but as ser item no 12 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 110mm dia PVC (SWR) vent cowl
Demolition of brick work built in cement or cement mortar of any description including quoins,arches,pillars, etc. all as specified and directed by Engr-in-Charge.
All as per item No 4 but except brick
Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specified and directed by Engineer in Charge.
M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified and directed by Engineer in Charge.
M&L PCC (1:2:4) type C-1 using 12.5mm graded stone aggregate as in coping including necessary form work, including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed by Engineer in Charge.
Providing precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate in landings, cover slabs, chullah hoods, chajjas, water troughs, mangers, septic tank slab and similar articles with plain faces and set in cement mortat 1:4 complete all as specified and directed by Engineer in Charge.
S & F in replacemen precast fibre reinforced cement concrete Manhole/drain cover including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mm x50 mm complete all as specified and directed by Engineer in Charge.
M&L for 150 mm bore DWCPE drain pipes laid in trenches and jointed in CM 1:1 with spun yarn complete all as specified and directed by Engineer in Charge.
M&L for 450mm bore DWCPE drain pipes laid in trenches and jointed in CM 1:1 with spun yarn complete all as specified and directed by Engineer in Charge.
M&L for sand cushioning under floor/sub base or in foundations including watering and consolidation complete all as specified and directed by Engineer in Charge.
M & L for hardcore of gauge n exc.63 mm(using broken stone or boulders) deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer in Charge.
S & F in replacemen precast fibre reinforced cement concrete Manhole cover including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mmx75mm complete all as specified and directed by Engineer in Charge.
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in foundation including rafts, footing, foundation beams, plinth beams, lintel band, bases for columns, etc and mass concrete complete all as specified and directed by Engineer in Charge.
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer in Charge.
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in roof beams, cantilevers, bressumers, lintels etc complete all as specified and directed by Engineer in Charge..
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies,desk slaby and in shelves and the like.
M&L formwork to sides of concrete foundation, footing, bases of columns, rafts and raft beams, sides and plinth beams; and similar work; vertical or to batter, rough finised surface of concrete complete all as specified and directed by Engineer in Charge..
M&L for formwork to side and soffits of floor or roof beam, lintel, fair finished flat surface of concrete complete all as specified and directed by Engineer in Charge.
M&L for formwork to sides of pillars, posts, columns, fair finished, rectangular, square or polygonal surface of concrete complete all as specified and directed by Engineer in Charge..
M&L PCC 1:4:8, type D2, 100 mm thick, finished even and rough to receive top surfaces complete all as specified and directed by Engineer in Charge.
M&L for rendering 10mm thick in CM 1:6 on fair faces or other than fair faces of brick work or concrete surfaces of walls firnished een and smooth withoutusing extra cement complete all as specified and directed by Engineer in Charge.
M & L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement incl scafolding etc, complete all as specified and directed by Engineer in Charge.
M&L for cement concrete 75mm thicktype C-1 1:3:6 using (20mm graded aggregate)as in plinth protection and paths laid in alternative panel filled with bitumastic filling complelte all as specified and directed by Engineer in Charge.
S&F Cast iron Bends/trap (any radius), diminishing pieces or tapers (larger bore measured) with oval access doors for 100mm bore pipe complete all as specified and directed by Engineer in Charge..
S&F Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors or fixed to walls all as directed for 100mm bore pipe of sand cast complete all as specified and directed by Engineer in Charge..
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and directed by Engineer in Charge.
M&L for glazed ceremic tiles (600x300x8mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick backing coat in cement mortar (1:6) complete all as specified and directed by Engineer in Charge.
S&F Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame and fixing with ancher bolts complete all as specified and directed by Engineer in Charge.
S&F 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
S&F MS butt hinges medium weight 100 mm size fixed with screws complete all as specified and directed by Engineer in Charge..
S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws complete all as specified and directed by Engineer in Charge..
S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with MS screws complete all as specified and directed by Engineer in Charge..
Supply and fix steel ventilator with top hung shutter including hinges, steel peg stay, complete half fixed glazed and half openable glazed complete all as specified and directed (Glass shall be measured and paid separately) complete all as specified and directed by Engineer in Charge..
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer in Charge.
S&F Sheet glass pin head type, 3.0mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer in Charge..
S&F in vitreous China squatting pan, 'orissa' pattern WC size 580 x 440 mm white with integral foot rest including connection complete all as specified and directed by Engineer in Charge..
S&F in 100 mm dia CI 'P' or 'S' trap complete all as specified and directed by Engineer in Charge. .
S&F in 10 Ltr PVC valveless, syphonic action type flushing cistern low level with inlet, ball valve, float and handle including brackets and PVC out let sutaible for IWC complete all as specified and directed by Engineer in Charge..
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in Charge.
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in Charge.
S & F in 15mm angle valve cast copper alloy screwed down high pressure with fancy type chromium plated handle screwed both ends or for unions etc complete all as specified and directed by Engineer in Charge..
Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for conceled water tubing etc cutting exceeding 10cm girth but not exc. 20 cm complete all as specified and directed by Engineer in Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specifed as direted by Engr-in-charge.
S & F 15mm bore CP bib tap fancy type long body cast copper alloy with capstan head handle screwed for iron pipe or for brass ferrule in repairs complete all as specified and directed by Engineer in Charge.
Material and labour for rotational moulded polyethylene water storage tanks 500 lts capacity, double layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description complete all as specified and directed by Engineer in Charge.
M & L for in PVC connection 450mm long with 2 nos brass check CP nuts as suitable complete all as specified and directed by Engineer in Charge.
S&Fin repairs shower rose, chromium plated brass, fancy type, 100x100 mm, with or without swivel , any size, including fixing to steel pipe or union, complete all as specified and directed by Engineer in Charge.
Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specified and directed by Engineer in Charge.
M&L for roof treatment as per the description below including dismantling/taking down existing roof treatment complete:- a) preparation of roof surfaces by removing all loose material /dust extra for carrying out water proofing treatment. b) Apply bituminous primer @ 0.3 ltr/Sqm (conforming to IS-3384) on prepared surfaces. After drying of primer apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm of prepared surfaces. c) Laying APP (Atatic Polypropylene) modified five layered membrane 3 mm thick and weighing not less than 3.50 Kg/Sqm with centre core 160 GSM/ Sqm ; core reinforced and laid with 75 mm side overlap and 150 mm end lap. The membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as per the manufacturer specification apply two coat of silver shield bitumestic aluminum paint complete all as specified and directed by Engineer in Charge.
M & L for point wiring complete with, PVC insulated and unsheathed cable 1.5 sq mm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 including medium duty concealed unplasticised PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal boxes not less than 1.6 mm thick of required. size (factory made) including top cover 3 mm thick of plastic laminated sheets of required colour for fixing switches complete with all accessories and all as specified including PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete the following :-
One light/fan point controlled by one by one way switch ( switch to be measured and paid separtely)
One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly complete all as specified and directed by Engineer in Charge. (socket and switches to be measured and paid separately)
S&F switch, flush type 5 amps single pole, one way complete all as specified and directed by Engineer in Charge.
M&L socket outlet 5 pin 5 Amp flush type all as specified and directed by Engr in Charge.
M&L ceiling rose, surface polycarbonate isolated body three terminals complete all as specified and directed by Engineer in Charge.
Supply and fixing fresh Air fan 230 sweep singe phase 230 Volts 50 Hz complete with accessories etc.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engineer in Charge.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed by Engineer in Charge.
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 10 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed by Engineer in Charge..
M&L angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified and directed by Engineer in Charge.
S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in Charge.
Supply and fix 12 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engineer in Charge.
S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection , having adjustable knob for temp control and inner tank should be glass line coated complete all as specified of capacity 25 ltr having heating element 1.5 KW and not less than 5 star rating.
Supply and Fix 45 W High efficient LED building security light with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings wall complete as specified and directed.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by Engineer in Charge.
Supply and fix MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in Charge.
Supply and fix MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in Charge.
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. strip from earth electrode to the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe Med grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed by Engineer in Charge.
Material, labour jointing & testing XLPE insulated armoured heavy duty electric cable with standard aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core including making connection with suitable size of cable gland, aluminium lugs etc complete including taking down old U/S cable complete all as specified and directed by Engineer in Charge.
Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed by Engineer in Charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed by Engineer in Charge.
Removal of excavated material to a distance not exc 50 Meter and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed by Engineer in Charge.
Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and directed by Engineer in Charge.
Supplying, laying sub class 'B' bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protectioncomplete all as specified and directed by Engineer in Charge.
Supply & Fixing in replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm diacomplete all as specified and directed by Engineer in Charge.
Note :- Total amount of Sch of credit is Rs. . 25000.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
GIAN ENGINEERS
M/S ANIL KUMAR
DR Buildcon
m/s lovely cool air
LAMBA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .