Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.2 L+₹1.5 L (19.6%)Rejected-Finance 93 4 16A BLOCK NO 3 JAWAHAR CHOWK PACHMARHI MP 461881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L2 | Rejected-Finance Not Admitted | |
| 3 | L3₹9.6 L+₹1.9 L (25.3%)Rejected-Finance SURVEY NO 93 392 PACHMARHI NEAR MILITARY HOSPITAL PAHMARHI HOSHANGABAD M P 461 881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L3 | Rejected-Finance Not Admitted | |
| 4 | L4₹9.8 L+₹2.2 L (28.3%)Rejected-Finance | L4 | Rejected-Finance Not Admitted | |
| 5 | L5₹10.3 L+₹2.6 L (34.0%)Rejected-Finance NEAR BUS STAND PACHMARHI MP PIN 461881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L5 | Rejected-Finance Not Admitted |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
9 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE Indpt Pachmarhi
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
SPL REPAIR OF BLDG NO. P/1 F-3 and P1 (B,C,D) AT MH PACHMARHI.
2022_MES_567357_1
CA No. AGE(I)/PACH/of 2022-23 (8520/E8
Open Tender
Civil Works
Item Rate
180 days
Pachmarhi Mp
Class E Category a(i)
8 documents required · 8 mandatory
₹500
AGE Indpt Pachmarhi
₹20,000
Yes
22 Feb 2023
5 Dec 2022
11 Jan 2023
5 Dec 2022
9 Jan 2023
19 Dec 2022
Amount
Dismantling of floor, walls, roof tiles including bedding but backing and rubbish off permises all as specified.
M&L for 10mm thick Light shade vitrified ceramic tiles in floors, exceeding 0.36 sqm but not exceeding 0.42 sqm set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified & directed.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.11 sqm and not exceeding 0.18 sqm in floors etc set & jointed in neat cement slurry and pointed with white or coloured cement to match complete.
M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 for laying of floor tiles as directed.
M&L for glazed ceramics coloured tiles of size 450x300x7mm thick in vertical surfaces such as skirting/dados/wall, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces.
M&L for 10 mm thick randering in cement mortar 1 : 4 for fixing of wall tiles complete all as specified.
Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) all as specified
M&L PCC 1:4:8 type D-2 (40mm graded agg) in fdn, sub base, mass concrete & cinder concrete etc. complete.
Taking down cement plaster on wall/ceiling/roof etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L 15 mm thick rendering on fair faces of bk/concrete surfaces in CM (1:6) finished even and smooth (without using extra cement ) complete all as specified.
M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete. Note : Liquid WPC will be measured and paid separately.
Supply only liquid water proofing compound , ISI marked.
Taking down shutter of any description exc 1 sqm and not exc 2 sqm each and removing to store.
Cutting holes in brick walls exc 1/2 brick & n exc full brick built in cement mortar for inserting hold fasts, cutting and preparation of brick wall for insertion of doors, windows & ventilator and making good dismantled portion in cement mortar 1:3 etc complete.
S & F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkhats for doors etc complete.
S&F anodised aluminium frame with powder coating (minimum thickness of powder coating 50 micron) for doors window ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S & F factory made 35 mm thick plain, framed, panelled shutters (Two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces and size of the members of shutter are as per IS – 1003 (Part – I) made of kiln seasoned & chemically pressure treated 2nd class hardwood rail and style complete all as specified and directed.
S & F 30 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides supplied and fitted to chowkats.
S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165.
S&F pressed steel frame size (105 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube supplying & fixing in opening as per specified & drawing.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 100 mm size Butt hinges, extruded SS with steel hinge pin, anodised and fixed, type B-21 all as spd.
S&F 75 mm size Butt hinges, extruded SS with steel hinge pin, anodised and fixed, type C-22 all as spd.
S&F Butt hinges (ISI marked), medium weight, cold rolled mild steel of size 100 mm.
S&F 200 mm long aluminum anodised barrel tower bolts of extruded section as specified.
S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed all as spd.
S&F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified.
S&F SS wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified.
S&F Factory Made Solid PVC Moulded Door Shutter, & kitchen cupboard shutters with particle board core 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing all as spd.. Make approved by GE.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 15 mm bore GI tubing.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 20 mm bore GI tubing.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing.
S&F in repair bib tap 15 mm bore fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete.
S&F in repair CP brass tubular towel rail 20 mm dia D type 60 cm long between flanges complete.
S&F in repair angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe.
S&F in repair of stainless steel soap dish, of standard size and shape complete.
S&F in repair vitreous china squating pan 'Orissa' pattern WC size 580x440 mm white with integral foot rest and trap and including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor all as spd.
S&F in repair 10 Ltr capacity PVC valveless shyphonic action type low level flushing cistern white with inlet, ball valve, float valve and handle incl bracket and flush pipe of low level of 32mm dia fixed to wall complete.
Dismantling timber scantlings as in framed work 40 sq. cm and over in section, in any position
M&L for 18 mm thick granite slab (of any type) work (table rubbed and polished) in cooking platforms, steps, window cills, incl edge moulding & cutting holes for gas pipe through drill machine and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete.
M&L Machine cut cudappah stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Taking down AC/PVC pipes (including all fittings), with spigot and socket ends and lead joints including burning out joints of 100 mm dia pipe.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall complete.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete.
S&F clamp made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 110mm PVC pipe complete.
M/L PVC(SWR) bend of 110mm dia of any radius etc complete all as specified and directed
M/L PVC(SWR) Tee of 110mm dia etc complete all as specified and directed
S&F PVC (SWR) bends any radius provided with access door of 75 mm dia
S&F PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 110 mm dia with access door
S&F PVC (SWR) multi floor trap, plain with grating with or without waste hole including jointing with solvent cement 75mm dia etc complete
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of primer complete.
M & L for preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete.
M&L Preparing old wooden surfaces exceeding 10Cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including glass and ss wiremesh,powder coating necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
M&L Preparing old steel surfaces exceeding 10Cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete.
M & L for preparation of newly plastered surfaces of wall & concrete and applying 2 mm thick wall care putty including preparation complete.
M&L for applying two coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper complete.
M&L for preparation of old decorated plastered or unplastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of white wash complete.
M&L preparation of new plastered or unplastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
S&F for MS framed works as in purline, rafters, column square/rectangular, round or angle section, fixed with and including iron cleats or other connected plates flate iron wind ties etc incl bending of MS section as requried omplete all as specified and as directed.Fe-410 gd 250
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, including ridge of same colour fixed with self tapping screws as specified
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick as in ridge,hip,valley of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified ®
Dismantling of ceiling board with fittings and any description including cover fillets as directed.
M&L for false ceiling at all height of 600x600x15mm mineral fibre ceiling tiles micro looks edge laid on supe fine XL 15mm exposed grid systems with 15mm wide T-section flanges. The frame work comprises of main runner of size 15x32x3000mm spaced at 1200mm centre securing fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers (GI wire of 4.0 mm dia) to be fixed by approved roof plug, level adjusters and screws etc. The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall flush fitting 1200mm long cross tees of size 15x26x1200mm to interlocked between main runners at 600mm centers to form a 1200mmx600mm module. Cut cross tees longer than that 600mm to be supported independently 600mmx600mm modules to be formed by fitting 600mm long flush fitting cross tees of size 15x26x600mm centrally between the 1200mm cross tees perimeter wall angle of size 19x19x3000mm secured to wall at 450mm maximum centers. Finally mineral fibre tile 15mm thick micro look edge has to be laid on the 600mmx 600mm module.
Taking down existing unserviceable/old point wiring surface /batten including fitting fixtures ,ceiling roses, pendant/angle holders, regulators, sockets,switches , PVC conduit complete all as specified and directed
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all fittings / fixing accessories and sunken modular GI metal boxes not less than 1.2 mm thick and white modular mounting cover plates with frame for mounting of modular switches, sockets, fan regulators etc as required for the following :- (a)(a) One light/exhaust point point controlled by one switch.
(b)One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc.
(c)One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board.
(d) One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size
S&F switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked
S&F for socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI marked.
S & F ceiling rose, surface Bakelite,isolated body three terminals complete all as directed.
S&F angle holder, insulated polycabonate body with back plate complete.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes not less than 1.2 mm thick and white modular mounting plates with frame for mounting modular switches, sockets as required for 3 pin 16 amps socket outlet controlled by one switch.
S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked
S&F for socket outlet, 5 Pin, 5 & 15 Amp flush type conforming to IS 1293 ISI marked
S & F 4 Way Novello vertical TPN distribution boards Double Door 415 V/50 Hz, protection class IP43 As per IS 8623 - III Impact resistance IK09 ,Provision for mounting Earth ,Leakage Relay, SVN Indications & MCCB RCD block way, MCCB+12 modules including taking out the old one. Make: HAGER Cat Pat No. VYV04DM or equivt make and model of LEGRAND/L&T
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 230 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces as per existing specified and directed .
Taking down existing unserviceable/old submain wiring surface /batten including PVC conduit complete all as specified and directed
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm all as specified and directed including taking down old one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
S&F MCB’s single pole, 10 KA ,6 Amp to 30 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996.the power loss per pole shall be low and shall be in accordance with IS 8828-1996,All cable entries shall be either from bottom or top .MCB shall be of C curve charactertics & shall have quick make and break non welding self wiping silver alloy contact for 10 KA short circuit both on manual & automatic operation .All the active ,live parts of MCBs should be out of human reach ,ensuring safty & conforming to IP 55 degree of protection .The MCBs must house transperent lebel holder to ensure circuit identification .The MCB must have fully insulated safty shutters.The MCB shall have lockable switching lever.The minimum electrical endureance shall be 20000 operations .The housing of MCB shall be mounted self-extinguishing DMC(Dough moulding compount).The short circuit current shall be brought zero within 4 t0 5 milliseconds from the time they are established complete all as directed.
S&F MCB’s single pole and neutal, 10 KA ,32 Amp to 40 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996.the power loss per pole shall be low and shall be in accordance with IS 8828-1996,All cable entries shall be either from bottom or top .MCB shall be of C curve charactertics & shall have quick make and break non welding self wiping silver alloy contact for 10 KA short circuit both on manual & automatic operation .All the active ,live parts of MCBs should be out of human reach ,ensuring safty & conforming to IP 55 degree of protection .The MCBs must house transperent lebel holder to ensure circuit identification .The MCB must have fully insulated safty shutters.The MCB shall have lockable switching lever.The minimum electrical endureance shall be 20000 operations .The housing of MCB shall be mounted self-extinguishing DMC(Dough moulding compount).The short circuit current shall be brought zero within 4 t0 5 milliseconds from the time they are established complete all as directed.
Supply and fix 4 Pole MCCB 12 to 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA
Supply & fix LED tube light along with fixture,18 W, 4 feet complete all as directed.
S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and directed
Earthing for poles & other machinery/equipment using 4 mm GI wire as earthing lead and MS galvanized plate of size 60 cm x 60 cm x 6 mm, as earth electrode.
S&F call Bell switch ( bell push) flush type 5 Amp 240 volt complete all as directed.
S&F call Bell AC 230 Volt, Single pole ding dong type complete all as directed.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 380 mm sweep with louver
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area , 3.5 core 35 sqmm
M & L for Excavation for taking out/laying cable in trenches in soft/loose soil not exc 1.5 m wide and not exceding 1.5 m deep for LT 1100 V under ground cable complete all as specified and directed by Engineer-in-Charge
Returning filling in including spreading, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing surplus soil to distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for narmada river sand, unwashed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed.
Supply and laying unreinforced precast concrete cable cover, class LV, type 1 with flat, size 250 mm x 150 mm x 40 mm complete all as directed at site. Make Mehtab or equivalent.
DEEPAK JAISWAL
Dev Enterprises
GHASI RAM SAHU
SUBIR KUMAR ROY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .