Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L1 | Accepted-AOC Accepted for lowest rate quoted | |
| 2 | L2₹38.3 L+₹89,900 (2.40%)Rejected-Finance | L2 | Rejected-Finance Reject due to highest rate quoted | |
| 3 | L3₹39.0 L+₹1.6 L (4.28%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance Reject due to highest rate quoted | |
| 4 | L4₹40.9 L+₹3.5 L (9.37%)Rejected-Finance NOT FOUND | L4 | Rejected-Finance Reject due to highest rate quoted | |
| 5 | L5₹41.0 L+₹3.6 L (9.63%)Rejected-Finance | L5 | Rejected-Finance Reject due to highest rate quoted |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
5 Sept 2023, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
ADDITION/ALTERATION WITH CONVERSION OF LT OVERHEAD INTO UG CABLES INCLUDING PROVISION OF LT PANELS FOR ELECTRIC DISTRIBUTION SYSTEM AND OTHER ALLIED WORK AT OFFICERS ENCLAVE AND CONNECTING AREA AT AF STN ARJANGARH UNDER GE AF GURGAON
2023_MES_612806_1
GE/GUR-/NIT-26/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹87,000
23 Sept 2023
8 Aug 2023
7 Sept 2023
8 Aug 2023
5 Sept 2023
22 Aug 2023
Amount
Dismantling of ACSR or AAC conductor complete all as specified and as directed.
Dismantling cross arms of MS channel or angle sections etc complete and setting for reuse or tpt to store complete all as specified and as directed.
Disamntling insulators any type any size complete all as specified and as directed.
Dismatling earth wire or copper conductor , service feedre or distribution span complete all as specified and as directed.
Supply, Fabricate, installation, testing and commissioning of CPRI approved outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 2 mm thick CRCA sheet (Make -Tata/ sail) ( load bearing members 2 mm thick and non load bearing members such as doors partitions etc of thick ness 1.6 mm thick ), with gland plates at bottom with suitable Brass chromium plated glands, with cadmium plated high tensile nut and bolts washers, suitable barrel copper lugs for cable terminations complete, with locking arrangements complete ,sheets bend, folded, cut with CNC machine for the accuracy of diamensions +/-0.5%, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars MCCB's with suitable size copper bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and as directed and comprising of the following (Near Old Officer's Mess/Mayur).
(a) Bus bar Aluminum - 600 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
b) MCCB four pole 440 V, 320-400 Amp,36 KA adjustable thermal and magnetic release -01 No ( As Incomer)
(c) MCCB four pole 440 V, 160-200 Amp,36 KA , adjustable thermal and magnetic release - 01 No
(d) MCCB four pole 440 V, 125-160 Amp,36 KA , with thermal and magnetic release - 01No
(e) MCCB four pole, 100-125 Amps 36 KA, with thermal and magnetic setting - 02 Nos
(f) MCCB four pole, 43-63 Amps 36 KA, with thermal and magnetic setting - 03 Nos
(g) MCB TPN, 63 Amps, 10 KA, 'C' Series-02 Nos as spare.
(h) MCB SPN 40 Amps 'C' series-03 Nos for misc supply.
(k) ON/OFF LED indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 1Set of three
(l) LED Multifunction meter accuracy class 1.0,input voltage 17 to 520V Ac, flush typ, 96x96 mm size, Model Vega of L&T / equivalent make of ABB/ siemens, suitable to measure parameters such as A,V,F,KW,KVA,KVAr,KVARh,Phase angle ,THD etc-01 No.
Supply, Fabricate, installation, testing and commissioning of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following (PANEL NO.2. MAIN PANEL OMQ SUB STN).
(a) Bus bar Aluminium - 1000 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
(b) MCCB 630 Amps, 50 Hz, 415 V with rupturing capacity 50 KA, Adjustable Thermal Mangnetic range -02 Main incomer
(c) On load change over switch 630 Amps, 415 Volts, open execution-01
(d) MCCB 250 Amps 3 pole 36 KA, with adjustable thermal magnetic range as out going- 04 No. (03 Nos for Panel No. 4, 5, & 6 and MAP Qtrs)
(e) MCCB 160 Amps 3 pole 36 KA with adjustable thermal magnetic range as out going- 03 Nos. (01 Nos for Panel No. 3 and 01 Nos for APFC Panel, 01 Nos spare)
(f) MCCB 100 Amps 3 pole 25 KA with adjustable thermal magnetic range as out going- 02 Nos. (Spare)
(g) MCB TP 63 Amps, 10 KA, 'C Series
(h) MCB SPN 40 Amps, 10 KA, 'B' Series
(j) Digital multifuctional meter (Make : L&T), 4410 Series, Cat No. WL441010OOOO
(k) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 11 Set of three
Supply, Fabricate, installation, testing and commissioning of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following (PANEL NO.4, DISTRIBUTION PANEL OMQ-04 TO 13).
(a) Bus bar Aluminium - 400 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
(b) MCCB 250 Amps 4 pole 36 KA, with adjustable thermal magnetic range as in coming - 01 No.
(c) MCCB 63 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 12 Nos. (10 Nos for OMQ-4 to 13, 02 Nos spare)
(d) MCB TP 63 Amps, 10 KA, 'C Series
(e) MCB SPN 40 Amps, 10 KA, 'B' Series
(f) Digital multifuctional meter (Make : L&T), 4410 Series, Cat No. WL441010OOOO
(g) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 13 Set of three
Supply, Fabricate, installation, testing and commissioning of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following (PANEL NO.5, DISTRIBUTION PANEL OMQ-14 TO 21).
(a) Bus bar Aluminium - 400 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
(b) MCCB 250 Amps 4 pole 36 KA, with adjustable thermal magnetic range as in coming - 01 No.
(c) MCCB 63 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 10 Nos. (08 Nos for OMQ-14 to 21, 02 Nos spare)
(d) MCB TP 63 Amps, 10 KA, 'C Series
(e) MCB SPN 40 Amps, 10 KA, 'B' Series
(f) Digital multifuctional meter (Make : L&T), 4410 Series, Cat No. WL441010OOOO
(g) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 11 Set of three
Supply, Fabricate, installation, testing and commissioning of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following (PANEL NO.6, DISTRIBUTION PANEL OMQ-22 TO 32) .
(a) Bus bar Aluminium - 400 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
(b) MCCB 250 Amps 4 pole 36 KA, with adjustable thermal magnetic range as in coming - 01 No.
(c) MCCB 63 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 13 Nos. (11 Nos for OMQ-22 to 32, 02 Nos spare, 01 No for sewage pump)
(d) MCB TP 63 Amps, 10 KA, 'C Series
(e) MCB SPN 40 Amps, 10 KA, 'B' Series
(f) Digital multifuctional meter (Make : L&T), 4410 Series, Cat No. WL441010OOOO
(g) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 15 Set of three
Supply, Fabricate, installation, testing and commissioning of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following (PANEL NO.3 DISTRIBUTION PANEL OMQ-1 TO 3).
(a) Bus bar Aluminium - 250 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
(b) MCCB 160 Amps 4 pole 36 KA, with adjustable thermal magnetic range as in coming - 01 No.
(c) MCCB 125 Amps 3 pole 25 KA with adjustable thermal magnetic range as out going- 01 Nos. (OMQ-01)
(d) MCCB 63 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 04 Nos. (02 Nos for OMQ-2 & 3, 02 Nos spare)
(e) MCB TP 63 Amps, 10 KA, 'C Series
(f) MCB SPN 40 Amps, 10 KA, 'B' Series
(g) Digital multifuctional meter (Make : L&T), 4410 Series, Cat No. WL441010OOOO
(h) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 14 Set of three
Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 240 sq mm complete all as specified and as directed.
Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 150 sq mm complete all as specified and as directed.
Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 120 sq mm complete all as specified and as directed.
Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 50 sq mm complete all as specified and as directed.
Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 25 sq mm complete all as specified and as directed.
Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 16 sq mm complete all as specified and as directed. (FOR SECURITY LIGHTS). Note for item No. 11 to 16. 1. The rate quoted by the contractor deemed to be inclusive of suitable size aluminium lugs at any required length at both ends of cable. 2. Suitable size of cable chromium plated stainless steel grands etc.
M&L for Cutting existing road surfaces or hard standing 0.45 mtr depth and 0.3 mtr width (22 CM thick comprising bituminous topping) for laying of pipes/cables and making good to the disturbed surfaces to match with existing complete all as specified and as directed. Note : Rate quoted by the contractor deemed to be inclusive of PCC 1:2:4 to be required to making good the disturbed surface to match with existing.
M & L for GI tubing (light grade) with all necessary fitting laid in trenches/under road crossing, or fixed on poles/walls/under floor etc complete all as specified and as directed for the following sizes:-
a) 40 mm bore.
b) 50 mm bore.
c) 80 mm bore
Excavation in trenches in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for pipes and getting out complete all as specified and as directed.
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and as directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and as directed.
M&L for sand cushning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and as directed.
Supply and lay well burnt brick class B as protection to cable in cable trenches complete all as specified and as directed.
Supply and fixing TPN DB's 4 way vertical type 415 V, double door suitable for housing of 100 Amps MCCB as main incoming complete all as specified and as directed.
Supply and fixing MCCB 63 Amps, 3 Pole, 16 KA, fixed type, suitable to be fixed in 4 way TPN DB complete all as specified and as directed.
Suply and fixing 240 V, 10 KA, 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity SP 40 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 2 core 10 sq mm complete all as specified and as directed. (for distribution having single phase)
Supply, laying, jointing and testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 35 sq mm complete all as specified and as directed. (for distribution having single phase). Note for item No. 27 to 28. 1. The rate quoted by the contractor deemed to be inclusive of suitable size aluminium lugs at any required length at both ends of cable. 2. Suitable size of cable chromium plated stainless steel grands etc.
S & F sub main wiring for circuit of size 10 sq mm 2 core (FRLS) alongwith earth wire of 6 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including PVC conduit of suitable size complete all as specified and as directed. (FOR SPN DB's)
M&L for earthing to switch gear/MCB DB with mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of galvanised iron nuts, bolts and washer, earth lead connected to eqpt as directed, earth plate surrounded with adequate quantity of charcoal dust mixed with common salt to a packed thickness of 15 cm all around the plate including necessary earth work, PCC chamber and reinforced PCC cover made by PCC 1:3:6 type C-1 as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with 6mm dia MS bar at 150mm c/c both ways with 10 mm dia MS round bar as handle, 20 mm bore GI pipe medium grade for watering and 15 mm dia GI pipe light grade for protection of earth lead up to 7.5 mtr with funnel, wire mesh etc with and including testing complete all as specified, as shown in electrical plate No 3 of MES sch Part I and as directed. (for TPN DB's)
M&L for Earthing complete for sub station equipments with galvanized steel earth pole electrod of size 600x600x6.3mm thick burried directly in the ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below the ground level, connected to galvanised iron strip 32 x 6mm by means of nuts, bolts,check nuts and washers of galvanised or steel all as specified or shown in electrical plate No. 3 of SSR-2009( Part-l), including ncessary earth work and excavation in any strata, GI pipe 40mm dia light grade for protection of galvanised iron earthing strip upto 7.5 mtrs, including concrete chamber of PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) having copping in PCC (1:3:6) Type C-1using 20mm graded stonr aggregate. Intemal surface of concrete chamber shall be plastered with 12mm thick cement mortar (1;4) and 50mm thick RCC cover in proportion (1:2:4) type B-1using 20mm graded stone aggregate, reinforced with 8mm dia tor bar@ 80mm c/c both ways and charcoale dust common salt etc.,funnel testing point, 8 mesh per liner inch, including test point , testing, complete . (04 Nos for transformer, 02 Nos for APFC panel, 02 Nos for Main receiving panel, 02 Nos for 02 Pole structure, 04 Nos lightening arrestor at 2 pole structure, 02 Nos for DG set, 01 Nos for street light poles) complete all as specified and as directed.
S&F pole box for street light dust and vermin proof with hinged door and locking arrangement make Sintex model GSJB 3020 complete with 4 way connector 2 Nos. of capacity 60 amps incl one MCB SP C series 06 amps 10 KA capacity for Security light connection with flexIble wire 3 core 2.5 sqmm with suitable size of PVC conduit and including suitable clamps & suitable size brass chrome plated glands-02 nos at bottom for cable entry and exit complete all as specified and as directed.
M&L for Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed. (for loop boxes and fixing of GI pipe with pole)
Supply and fixing MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with rupturing capacity 36 KA complete with sheet metal enclosure and extended terminals all as specified and as directed.
M&L for cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded aggregate) incl form work complete all as specified and as directed.
A B K Enterprises
M/S Rohit Enterprises
shiv shanker enterprises
GULSHAN SINGH GHAI AND SON
M/S Anand Enterprises
Commercial Traders
akhil enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .