Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Lowest quoted bidder | |
| 2 | L2₹5.0 L+₹48,805 (10.9%)Rejected-AOC NO 22 KUNNIJI NAGAR 1ST STREET EAST TAMBARAM CHENNAI 600 059 TAMIL NADU | CHENNAI | CHENNAI | TAMIL NADU | 600059 | L2 | Rejected-AOC Other than L1 bidder | |
| 3 | L3₹5.5 L+₹1.0 L (22.9%)Rejected-AOC NO 1 116 GANGAI AMMAN KOVIL STREET SORANJERY PATTABIRAM CHENNAI 600072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L3 | Rejected-AOC Other than L1 bidder | |
| 4 | Rejected-Technical NO 6 BAJANAI KOIL CROSS STREET CHATHIRAM PATTABIRAM CHENNAI 600 072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | - | Rejected-Technical NO remark in WLR |
Tender Value
₹6.8 L
EMD Value
₹13,600
Closing Date
23 Apr 2021, 6:00 pmClosed
AGE(I) Navy Chennai
AGE(I) Navy Chennai Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
REPAIRS TO EXTERNAL WATER SUPPLY, PIPELINE, PUMP SET AND CLEANING OF BOREWELL ETC AT TS AVADI UNDER AGE(I) NAVY CHENNAI
2021_MES_433119_1
AGE(I)/NAVY/CHN/8189 of 2020 - 21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹13,600
Yes
14 Jul 2021
26 Mar 2021
24 Apr 2021
26 Mar 2021
23 Apr 2021
9 Apr 2021
27 Mar 2021 - 2 Apr 2021
Amount
Supply and laying in repair in trenches steel water tubing 25 mm dia,medium grade, galvanized including all fittings and taking up or down existing tubing with all connections for taking into credit, complete all as specified and as directed.
All as per Sl item No. 01 above but for 40mm dia
All as per Sl item No. 01 above but for 50mm dia
Supply and fixing in repair steel water tubing 25mm dia,medium grade, galvanized including all fittings, on walls, ceilings or laid in floors, and taking up or down existing tubing with all connections for taking into credit, complete all as specified and as directed.
All as per Sl item No. 04 above but for 40mm dia
All as per Sl item No. 04 above but for 50mm dia
Supply and fix, in repair gun metal gate valve, 25mm dia, with iron wheel head confirming to IS 778 class I, screwed both end for iron pipe and removing unserviceable gate valve, complete all as specified and directed.
All as per Sl item No. 07 above but for 40mm dia
All as per Sl item No. 07 above but for 50mm dia
Taking out the old unservicable sluice valve and supply and fix CI Sluice Valve Class PN 1.6 100 mm dia conforming to IS 780 with flanged and drilled ends and of any pattern including necessary jointing and jointing materials complete (with rubber gasket, bolts and nuts etc., ) all as specified an as directed.
Removing unserviceable foot valve/ check valve of 40mm dia from the suction pipe of the pump set, supply and fix New check valve, heavy duty of gun metal, both ends threaded and end leaf spring loaded vertical type, complete all as specified and directed.
All as per Sl item No. 11 above but for 50mm dia
Flushing the bore well of size 150mm dia, 60 metre deep by means of Air compressor of capacity not less than 650 CFM at 150 PSI pressure for not less than four hours till the clear vwater comes out.
Repairs to 5 HP capacity electric driven centrifugal pumpset, replacement of spares in the existing position complete all as specified and directed. Make: Kirloskar/ Ventura/ Suguna/ Tulu (Note: Rewinding and supply of Spares will be paid under seperate items here in after)
Rewinding of motor starter coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge.
Supply only Ball bearing (drive and non dirve end)
Supply only Electrodynamically balanced bronze impeller.
Supply only Gunmetal bush.
Repairs to 5 HP capacity submersible pumpset,3 Phase, 440 volts including replacement of spares complete all as specified and directed. Make: Kirloskar/ Ventura/ Suguna/ Tulu (Note: Rewinding and supply of Spares will be paid under seperate items here in after)
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge.
Supply only Stainless steel shaft
Supply only Ball bearing
Supply only Stainless steel bush
Supply only Water seal
Supply only Submersible cable 3 core, copper stranded 2.5 sqmm flat type
Lifting of pumpset from bore well 76 metres deep and lowering into borewell after repair
Supply and replacement of DOL Starter 3 phase, 440 Volts with relay range up to 10 HP, including taking down old unservicable one, complete all as specified and directed.
Supply and replacement of star delta starter, open execution type with single phase protection and relay range from 13 – 32 Amps, 3 Phase, 440 Volts including taking down old unservicable one, complete all as specified and directed.
Supply and fix Ammeter size 96 mm square type, range 0 to 60 Amps and dismantling the existing unserviceable ammeter from the panel board complete all as specified and directed.
Supply and fix voltmeter size 96 mm square type range 0 to 500 volts and dismantling the existing unserviceable voltmeter from the panel board complete all as specified and directed.
Supply and fix CI fitting for spigot & socketed pipe up to 150 mm bore having bends 9 any type, radius and angle, tapers any type, Staright, bend, increasing, decreasing or double socket etc , Tee pieces, single branch , "y" Junction, double branch, cross all sockets or socket and spigot collars, caps and plugs, complete all as specified and as directed. Make :Electro steel/ Kejriwal/NECO/Kesoram
Material and labour for running lead joint for 100 mm dia CI pipe including spun yarn and other accesories, complete all as specified and as directed.
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead
Material and labour for cast iron pipes 100mm bore, with spigot ends centrifugally cast, Class LA, in any length, laid in trenches, including taking out old unserviceable pipe, complete all as specified and as directed. Make :Electro steel/ Kejriwal/NECO/Kesoram
Material and labour for preparation of old painted surfaces of LT panels and spray painting with two coats of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old painted surfaces of pipe lines and accessories like pump and motor along with panels of pump house and spray painting with two coats of synthetic enamel paint complete all as specified and directed.
Cleaning and removing of sludge/mud from the sump, 6 mtr dia and 6 mtr depth including making necessary arrangement as required and removing the mud from the site to the place as directed by the Engr-in-Charge.
Cleaning and removing of sludge/mud from overhead reservoir 25 feet staging, 3000 GLNS including making necessary arrangement as required and removing the mud from the site to the place as directed by the Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm obtained from excavation complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
Sri Sankar Enterprises
Mariammal Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .