Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹9.5 L+₹1.7 L (22.2%)Rejected-AOC | L2 | Rejected-AOC BEING NOT LOWEST | |
| 3 | L3₹16.6 L+₹8.9 L (114.4%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ADMITTED |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
4 Jul 2023, 5:00 pmClosed
Shri Budha Ram,IDSE
AGE I AF CHIMNEY HILLS, CHIKKABANAVARA,BANGALORE
REPAIR AND MAINTENANCE OF PERIMETER SECURITY LIGHTS, STREET LIGHTS SOLAR LIGHT, SOLAR WATER HEATERS, AND OTHER MISC WORK AT 58 SU AF STATION CHIMNEY HILLS.
2023_MES_602264_1
8630/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AGE I AF CHIMNEY HILLS BANGALORE
As per tender document
8 documents required · 8 mandatory
₹500
Yes
AGE I AF CHIMNEY HILLS BANGALORE
₹18,000
Yes
21 Nov 2023
9 Jun 2023
5 Jul 2023
9 Jun 2023
4 Jul 2023
20 Jun 2023
9 Jun 2023 - 19 Jun 2023
Amount
Material and Labour for servicing of Solar street light fitting of 2x11/1x11 watt capacity including servicing of module cleaning, battery inspection, checking of distilled water in battery , inspection of electronic circuits all as specified and directed by engineer in charge. Note:-Battery charging ,disconnect ,connection cost one time if Battery discharge,is included in the above quoted rates
Supply and Fix in Repair Solar battery 110 AH 12 Volts ,C10 Rating all as specified and directed by engineer in charge . .Note -Manufacture warranty certificate shall be deposited by contractor before payment .
Supply and Pore battery electrolyte (distilled water with acid) once in every quarter for each battery all as specified and directed by engineer in charge.
Supply and Fix in repair luminaire assembley for 1x11 watt,efficacy 100 lumen/watt ,Total lumens 1100 , LED lamps (New solar light fittings) with complete accessories all as specified and as directed.
Material and Labour or repairs to solar water heater system by checking the leakage / sepage of the system if found rectified through the authorised dealers. Draining out the system by opening the cold water out let and hose to the bottom tank,dry out the system refilling the same after rectifing the leakes ,topping up with anti freeze solution of soft water,check the corrosion sacrificial anode,replace if found defective,clean the collector of capacity 100 LPD complete all as specified and as directed.
All as per Item ser No 5 here in before but capacity of 200 LPD
Supply and fix in Repair LED Driver ,suitable for Street light 50 to 70 Wattage,Input supply AC 85 to 265 V,Output supply DC 48 to 72 V,IP65 protected ,50 /60 Hz,THD <10% all as specified and directed
Supply and laying in repair CPVC pipes 20mm, SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S&F in repairs CPVC Ball valve suitable for 20mm dia pipe complete all as specified and directed
Supply and Fix in replacement of solar standalone street light having in-built SCC, 20 watts luminaire(one No.),Total Lumens output 2650 lumens, 50 Wp solar panel, Battery 24 Ah lithium ion , HDG tubular pole 5 mtr, etc including civil work for fixing the stand post complete all as specified and directed Make : Havells cat No SOLAR AIO 20 W or Eqvt
Supply and Fix in repair thoughened Glass 6mm for Solar Water Heater Flat Plate collector, fix and seal as recommended by the manufacturer and all as directed
Supply and fix in replacement LED street light 60 watt,Lumen efficacy 100 lumen/watt,Total Lumens 6000,5700 K Temperature made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete all as specified and directed by engineer in charge .
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core including dismantling of old U/S cable
All as per item no.13 above but 10 Sqmm 4 core
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in hard/dense soil for laying of cables all as specified and directed by engineer in charge.
Returning, filling in including spreading leveling, watering and well ramming in layers n. exc 25cms in hard/dense soil.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and spread dry vegetable Riddled soil in trenches for cable Cushioning.Note: for purpose of payment punned thickness only will be measured and paid.
Supply and lay burnt bricks, class 'B' designation 75 of size 230 mm x 115 mm x 75 mm for cable protection all as specified and directed by engineer in charge.
Supply and lay HDPE pipe ,6 kgf/cm2, 32 mm dia in trenches for road crossing/laid in floors etc.
Supply and fix for Hard PVC junction box (Make :- Sintex) of size 200x150x150 mm weather proof with bus bar for three phase and neutral link including MCB SP 6 Amps -1 No and necessary cable gland- 2 Nos for 10 sqmm 4 core cable and locking arrangement and fixing with existing PCC / steel tubler electric pole above the copping with suitable MS clamps, nuts & bolts and necessary electric connection etc.and necessary connection with suitable size cable complete all as directed .
Material and Labour for Aluminium painting to Steel tubular Street light pole for 5.5 mtr from top towards bottom and next 0.45 mtr Navy Blue and next 1.10 mtr white and 0.45 mtr Synthetic enameld paint yellow & black colour (Tiger cross) on Coping and writing pole No with white paint inside of black circle above the Navy blue painting and aluminium painting to GI bracket / pipe etc. above the copping and all as specified and and as directed.
Material and Labour in Replacement sub main wiring with two single core 1.5 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 1.5 sqmm multi stranded copper conductor FRLS cable as earth continuity conductor drawn into steel pole including accessories fixed on poles with proper bracings complete all as specified and directed. Note:- Two runs of 1.5 sqmm, one run of 1.5 sqmm conductors and one run of PVC conduit shall be measured as one unit.
Material and Labour in Replacement sub main wiring with two single core 1.5 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 1.5 sqmm multi stranded copper conductor FRLS cable as earth continuity conductor drawn into and including non-metalic rigid PVC conduit 20mm dia including accessories fixed on poles with proper bracings complete all as specified and directed. Note:- Two runs of 1.5 sqmm, one run of 1.5 sqmm conductors and one run of PVC conduit shall be measured as one unit
Material and Labour in Replacement sub main wiring with two single core 2.5 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 2.5 sqmm multi stranded copper conductor FRLS cable as earth continuity conductor drawn into and including non-metalic rigid PVC conduit 20mm dia including accessories fixed on poles with proper bracings complete all as specified and directed. Note:- Two runs of 1.5 sqmm, one run of 1.5 sqmm conductors and one run of PVC conduit shall be measured as one unit.
Marking of Street light pole made of Steel and RCC by writing letter of size not less then 5 CM /figures (i.e. MES and 01 to 150 etc ) on black back ground surface of 150 mm dia with white synthetic enamel paint including removing existing letter/figures complete all as specified and as directed.
Marking of Solar Street light pole made of Steel by writing letter of size not less then 5 CM /figures (i.e. MES and 01 to 150 etc ) on black back ground srface of 150 mm x 100 mm x 5 mm Steel plate with white synthetic enamel paint including Clamp fixed to existing pole complete all as specified and as directed.
Attending Electric Complaints for street lights/Security light/ Tower light/Flood light / Building light/Street Light LT UG Cable any type and capacity for continuous running, all as specified and directed by Engineer in charge. Note :(i) Complaints shall be attended by Electrician with in 48 Hrs . (ii) Any items consumed in the Light Complaints, shall be measured seprately with fixing charges . No attending charges shall be paid extra for Complaints for that complaint. (iii) Electric complaints attending charges is not paid when Any other item(New Electric fitting,Cable,Submain wiring etc) has been consumed already. (iv)If Contractor fails to rectify complaint with in 48 hrs ,Then 100 Rs per Complaints per 24 hrs shall be recovered in the RAR.(v) Ladder for fixing and repair work of LED Street light provide by the contractor.
Material and labour Corrugated PVC Pipe 20 mm dia all as specified and directed .
M&L in Repair Plain cement concrete1:3:6 type C1 using 20 mm graded stone aggregate as in Pole plinth foundation including necessary formwork, weathering slightly, rounded or chamferd angles and throating etc; including two coats of white wash complete all as specified and directed all as specified and as directed.
Supply and fix in repair Solar Water Heater Evacuated tube of length 1800 mm and dia 58 mm ,made of Super hard three layer borex silica ,fix and seal as recommended by the manufacturer and all as directed and specified by engineer in charge
S & F in replacement die cast aluminium IP66 LED Flood Light luminaire, 200 Watt capacity,efficacy 100 lumen/watt ,Total Lumen 20000 Watt all as specified and directed By engineer in charge .
S & F in replacement die cast aluminium IP66 LED Flood Light luminaire, 150 Watt capacity,efficacy 100 lumen/watt ,Total Lumen 15000 Watt all as specified and directed By engineer in charge .
S & F in replacement die cast aluminium IP66 LED Building Light luminaire with high power LEDs, 25 Watt of Luminious efficacy 120 Lumen /Watt,Total Lumens 3000,5700 K Temperature , capacity all as specified and directed by engineer in charge.
S & F in replacement die cast aluminium IP65 LED Flood Light luminaire with high power LEDs, 30 Watt of Luminious efficacy 100 Lumen /Watt,Total System Lumens 3000,6500 K, capacity all as specified and directed by engineer in charge.
S&F in replacement Post top lantern LED TYPE 35 Watt,Outdoor type ,5700 K Temperature,Lumen efficacy 80 Lumens/watt,total Lumens 2800 ,IP 65 Protection ,with decorative post top with 360 degree indirect light all as specified and directed by engineer in charge.Make- Wipro cat Part No LP07-431-XXX-57-CL/Havells Cat part No RUBYPT35WLED757PSYMTOPC/Bajaj Cat part No BGCT W4 LED WW
Material and labour in Repair for PCC of LED Bollard fitting by taking down Bollard fitting and demolishing existing PCC and Make New RCC pedestal of Size 400 mm x 200 mm x 200 mm including GI Sheet 2 Module Box ,Sunmica sheet and refixing the same Bollard fitting by Anchor fastener all as specified and directed .
S&F Street light Contactor ,Maximum optimum current 20 Amps ,AC1 type ,integrated auxiliary contact 1 NO,Control voltage 230 V for 4 pole all as specified and directed by engineer in charge.
Supply and fix Street light Timer ,Digital type ,all as specified and directed by enginneer in charge .
Supply and fix in replacement Straight hot shrink cable joint kit for LT ug cable of size 16/10 sqmm 4 core including excavation,refilling of earth work at undergruond cable fault position and making good surface at the fault position complete all as specified and as directed.Note-Cable fault Position shall be detected by the contractor by Manual exacavation upto 30 Mtrs Length .
Supply and fix in replacement Straight hot shrink cable joint kit for LT ug cable of size 10 sqmm 2 core including excavation,refilling of earth work at undergruond cable fault position and making good surface at the fault position complete all as specified and as directed.Note-Cable fault Position shall be detected by the contractor by Manual exacavation upto 30 Mtrs Length .
S & F in replacement GI pipe bracket 25 mm medium grade dia not exceeding 1.2 mtrs long bend to shape suitable for fixing street light to PCC/steel pole including suitable size MS clamps, bolts, nuts, washers, etc.
M&L Painting work of Cross arms structure of Solar hot water system 100 LPD and PVC Tank 200 LPD Capacity with two coats of black paint over one coat of red oxide primer all as specified and directed by engineer in charge.
M&L Painting work of Cross arms structure of Solar hot water system 200 LPD Capacity and its PVC Tank 500 LPD Capacity with two coats of black paint over one coat of red oxide primer all as specified and directed by engineer in charge.
Material and labour PVC insulated,PVC round sheathed multicore industrial cable of size 3 Core ,2.5 Sqmm for voltage grade upto 1100 V,as per IS 694 all as specified and directed by engineer in charge.
Supply & Fix in repair Solar hot water Tank 100 LPD capacity,made of Low carbon steel with porcelain coating ,Outer tank made of Mild steel ,Insulated with PUF 55 mm all as specified and directed by engineer in charge .
Supply & Fix in repair Solar hot water Tank 200 LPD capacity,made of Low carbon steel with porcelain coating ,Outer tank made of Mild steel ,Insulated with PUF 55 MM all as specified and directed by engineer in charge .
Supply and fix Non Return valve ,15 mm dia ,Made of Brass all as specified and directed by engineer in charge.
Supply and fix Non Return valve ,20 mm dia ,Made of Brass all as specified and directed by engineer in charge.
S & F in repair heating element 2 KW of any type suitable for Solar Hot water system as per directed and specified by engineer in charge.
S & F in repair heating element 1.5 KW of any type suitable for solar hot water system as per specified and direcetd by engineer in charge.
Supply and fix in repair LED Driver ,suitable for Bollard fittings 7.8 Wattage Wattage,Input supply AC 85 to 265 V,Output supply DC 55 to 70 V,IP65 protected ,50 /60 Hz,THD <10% all as specified and directed
Forge Engineering & Electricals
SP ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .