Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.8 L+₹9,549.46 (1.66%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹6.2 L+₹50,697.86 (8.83%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹6.3 L+₹54,126.24 (9.43%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹7.1 L+₹1.4 L (23.8%)Rejected-Finance 00 BAJRANG CHOK MAHOBA MAHOBA UTTAR PRADESH 210427 | MAHOBA | UTTAR PRADESH | 210427 | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
1 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF MEMAURA
AGE (I) AF MEMAURA
REPAIR/MAINT OF STREET/SECURITY LIGHTS,HIGH MAST LIGHTS,BOLLARDS AND OTHER ALLIED WORKS AT AF STN MEMAURA
2024_MES_652442_1
8336/E8
Open Tender
Electrical and Maintenance Works
Works
183 days
AGE (I) AF MEMAURA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) AF MEMAURA
₹19,000
Yes
11 Oct 2024
6 May 2024
3 Jun 2024
6 May 2024
1 Jun 2024
20 May 2024
Amount
Dismantling and taking down carefully defective/non fuctional LED street light fittings from its existing position and refixing the same after repairing/replacement of unserviceable spare parts including re-assembling and testing complete all as specified and directed. (Note : Spare parts/component of street light and other light fitting shall be measured and paid seprately under respective items.)
Supply and fix in replacement LED street light fittings 35 watt complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection complete all as specified and directed.
Supply and fix in replacement LED street light fittings 60 watt complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection complete all as specified and directed.
Supply and fix in replacement LED flood light 50 watt 230 V, Warm White, AC outdoor type with thermal management in multiple optics and equipped with IP66 ,protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fix in replacement LED flood light 150 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 ,protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fix in replacement LED flood light 250 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 ,protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fix in replacement aluminium round Decorative LED post top lantern 40 watt with transparent diffuser, 230 volts AC outdoor type, IP 65 with impact and corrosion resistant, pole mounted complete with driver and lamp complete.
Supply and fixing in replacement LED strip lights, having IP65 rating, warm white (3000K) colour temp, complete all as specified and directed.
S & F in replacement of 6W decorative LED extruded aluminium mini bollard light, warm white, rectangular shape with integrated driver etc including cable connections complete all as specified and as directed.
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable/pipe etc. complete all as specified and as directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soft/loose soil, complete, all as specified and directed.
Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point, complete, all as specified and directed.
Material and labour for providing sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed.
Supplying & laying burnt clay bricks, sub class 'B', laid in trenches over cable protection complete all as specified and directed.
Taking up/down old U/S 6/10/16 sqmm 2/4 core XLPE insulated & armoured Al cable all as specified and directed.
Supply, laying and testing of LT cable 1100 volt grade XLPE insulated underground electric cable PVC bedded and sheathed steel wire/strip armoured aluminum stranded conductor of size 6 Sq mm 2 core complete all as specified and directed.
All as per item No - 16 but size 10 Sqmm 2 core
All as per item No - 16 but size 10 Sqmm 4 core
All as per item No - 16 but size 16 Sqmm 4 core
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
M&L for 40mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for 25mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in replacement street light bracket made out of GI tubing 40mm bore medium grade n.exc 1.5 metre long bent to shape as directed including suitable MS clamp of FI 50x6mm with MS bolts nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S & F in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 Nos of single pole MCB SP 0.5-3 Amp 'C' series inside the box and all specified and directed.
Supply and fix in replacement LED driver sutable for 35 watt to 90 watt LED fittings including connection all as specified and directed.
Supply and fix in replacement LED driver sutable for 120/150 watt LED fittings including connection all as specified and directed.
M&L painting of LT steel tubular pole with one coat of aluminium paint including brackets and synthetic enamel painting of Air Force blue (0.75M above foundation) and 02 Nos alternate layer of red & yellow colour self adhesive reflectic tape of 100MM width & writing pole number on black background with white lettering after scraping /cleaning well the existing rusted surface complete all as specified and directed.
M&L painting of LT octagonal pole bottom portion with two coat of Air Force blue (0.75M above foundation) over a coat of red oxide primer & 02 Nos alternate layer of red & yellow colour self adhesive reflectic tape of 100MM width & writing pole number on black background with white lettering after cleaning well the existing surface complete all as specified and directed.
S & F MCB single pole 240 volts, 'C' curve of rating 0.5 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
S & F MCB TPN 415 volts, 'C' curve of rating 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
S & F in replacement Contactor of rating 40 Amps 440 V, triple pole with auxiliary contacts for AC circuit, DIN mounting confirming to IS/IEC 60947-4-1 complete all as specified and directed. Make : L&T /BCH/ Siemens/Schneider.
S & F Analog type timer, 220 V AC, curent rating 16 Amps, ON-OFF-ON type, Daily programmable, DIN rail mounting and testing on completion complete all as specified and directed. Make : Havells/L&T /ABB or equivalent.
Material and labour in replacement 1.5 sqmm three core copper PVC insulated sheathed cable drawing into inside the Pole / bracket of street light including making hole of 15 mm dia on bottom & top complete all as specified and directed.
M&L for earthing complete with galvanized steel pipe electrode 40 mm bore, medium grade 2.50 meters length, buried in ground vertically to a depth n.less than 3.75 mtr below normal ground level and connected with GI earthing wire 4 mm dia by means of bolts, nuts and washers made of galavanised iron and steel earth wire protected by 15 mm bore light grade GI pipe incl PCC work as per sketch No - 2 of SSR Part -I (2009) pit cover slab of size 300x300x50 mm with handle as shown in drawing funnel, wire mesh 20 mm dia GI pipe medium grade for watering, charcoal and slat in alternate layers incl necessary earth work and excavation in soft/loose soil and removal etc incl testing complete all as specified and directed including tesing on completion.
Supply and Installation in replacement of LED Aviation obstruction light aluminium alloy housing, red coloured poly carbonate dome and accessories including fixing of 3 m long GI tubing 50 mm dia complete all as specified and directed. Make BAJAJ/ Havells or equivalent.
Excavation in post holes (or similar holes ) each not exceeding 0.5 CUM, getting out, returning, filling in and ramming earth or borken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M & L for PCC (1:3:6) type C2 (using 40mm graded crusehd stone aggregate ) as in foundation of pole including necessary form work complete all as specified and directed.
M & L Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:4 all as specified and as directed.
M & L for 15 mm thick rendering in cement morter (1:4) on fair face of brick or concrete surface finished even and fair all as specified and as directed.
S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of gate lights and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
Unnati Engineers
M/S KAUSHIK CONSTRUCTION
m/s pal associates
HINDUSTAN TRADING COMPANY
Industrial Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .