Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC | ₹33.2 L Quoted ₹33.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹35.6 L+₹1.8 L (5.33%)Rejected-Finance | ₹35.6 L+₹1.8 L (5.33%) | L2 | Rejected-Finance being other than lowest |
| 3 | L3₹36.4 L+₹2.6 L (7.74%)Rejected-Finance | ₹36.4 L+₹2.6 L (7.74%) | L3 | Rejected-Finance being other than lowest |
| Sl No | Description | Qty | Unit | M/S N JADUMANI SINGH L1 | Ms SATISH CHAND AGARWAL L2 | M/s Nongmaithem Construction L3 |
|---|---|---|---|---|---|---|
| 1.00Schedule 'A' | ||||||
| 1.01 | Material and labour for conducting ‘B’ check of DG Set 500 KVA capacity Make: Kirloskar at 183 MH DG sets of above capacity installed at 183 MH to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Check for any diesel lekage from any point and rectify if observed.
(v) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.
(vii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(viii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(ix) Check exhaust pipe, flange and lagging Repair if found damaged.
(x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xi) Checking of all hoses and cleanup,change/tighten if required. (xii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 1 | Each Job | 22,595 ₹22,595 Lowest | 23,000 ₹23,000 | 23,500 ₹23,500 |
| 2.00 | Material and labour for conducting ‘B’ check of DG Set 160 KVA capacity Make: Kirloskar at High Lift Pump House DG sets of above capacity installed at above location to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Cleaning the fuek tank with the help of kerosene oil including replacement of level indicator pipe.
(v) Check for any diesel lekage from any point and rectify if observed.
(vi) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vii) Check leakage of smoke from exhaust system/silencer,Repair if required.
(viii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(ix) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(x) Check exhaust pipe, flange and lagging Repair if found damaged.
(xi) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xii) Checking of all hoses and cleanup,change/tighten if required. (xiii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiv) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 1 | Each Job | 16,220 ₹16,220 Lowest | 16,850 ₹16,850 | 17,500 ₹17,500 |
| 3.00 | Material and labour for conducting ‘B’ check of DG Set 100 KVA capacity Make: Kirloskar at 183 MH & 57 MDSR, DG sets of above capacity installed at above location to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Check for any diesel lekage from any point and rectify if observed.
(v) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.
(vii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(viii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(ix) Check exhaust pipe, flange and lagging Repair if found damaged.
(x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xi) Checking of all hoses and cleanup,change/tighten if required. (xii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 2 | Each Job | 13,230 ₹26,460 Lowest | 13,540 ₹27,080 | 14,500 ₹29,000 |
| 4.00 | Material and labour for conducting ‘B’ check of DG Set 62.5 KVA capacity Make: Kirloskar at 183 MH & KLP Pump House, DG sets of above capacity installed at above location to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Check for any diesel lekage from any point and rectify if observed.
(v) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.
(vii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(viii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(ix) Check exhaust pipe, flange and lagging Repair if found damaged.
(x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xi) Checking of all hoses and cleanup,change/tighten if required. (xii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 2 | Each Job | 12,108 ₹24,216 Lowest | 12,250 ₹24,500 | 13,000 ₹26,000 |
| 5.00 | Material and labour for conducting ‘B’ check of DG Set 30 KVA to 45 KVA capacity Make: Kirloskar at 27 R&O Flt & E/M complaint Cell, DG sets of above capacity installed at above location to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Check for any diesel lekage from any point and rectify if observed.
(v) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.
(vii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(viii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(ix) Check exhaust pipe, flange and lagging Repair if found damaged.
(x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xi) Checking of all hoses and cleanup,change/tighten if required. (xii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 2 | Each Job | 12,005 ₹24,010 Lowest | 12,458 ₹24,916 | 12,685 ₹25,370 |
| 6.00 | Supply only the following spare parts/items for DG set capacity 500 KVA complete as specified and as ditected. (Make : Kirloskar) (Note: Make of spares parts shall be of the same original manufacturer as per existing) :- (6.01) Diesel fuel filter assembly (Pre filter & Micro filter) | 2 | Each | 4,855 ₹9,710 Lowest | 5,100 ₹10,200 | 5,120 ₹10,240 |
| 7.00 | (6.02) Air filter assembly | 2 | Each | 4,356 ₹8,712 Lowest | 4,450 ₹8,900 | 4,895 ₹9,790 |
| 8.00 | (6.03) V' belt as per existing make/model | 1 | Each | 1,625 ₹1,625 Lowest | 1,758 ₹1,758 | 1,854 ₹1,854 |
| 9.00 | (6.04) Fuel pipe | 1 | Each | 2,258 ₹2,258 Lowest | 2,356 ₹2,356 | 2,569 ₹2,569 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
24 Jun 2026, 6:00 pmClosed
GE 869 EWS
GE 869 EWS PIN-913869 C/o 99 APO
REPAIR/MAINT OF DG SETS, AMF PANELS, LT PANEL AND ALLIED WKS AT LMS UNDER GE 869 EWS.
2026_MES_769113_1
8755/E8
Open Tender
Civil Works
Item Rate
210 days
LEIMAKHONG MIL STN
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
GE 869 EWS
₹66,000
Yes
1 Aug 2026
2 Jun 2026
25 Jun 2026
2 Jun 2026
24 Jun 2026
17 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Schedule 'A' | |||||
| 1.01 | Material and labour for conducting ‘B’ check of DG Set 500 KVA capacity Make: Kirloskar at 183 MH DG sets of above capacity installed at 183 MH to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Check for any diesel lekage from any point and rectify if observed.
(v) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.
(vii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(viii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(ix) Check exhaust pipe, flange and lagging Repair if found damaged.
(x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xi) Checking of all hoses and cleanup,change/tighten if required. (xii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 1 | Each Job | - | - |
| 2 | Material and labour for conducting ‘B’ check of DG Set 160 KVA capacity Make: Kirloskar at High Lift Pump House DG sets of above capacity installed at above location to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Cleaning the fuek tank with the help of kerosene oil including replacement of level indicator pipe.
(v) Check for any diesel lekage from any point and rectify if observed.
(vi) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vii) Check leakage of smoke from exhaust system/silencer,Repair if required.
(viii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(ix) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(x) Check exhaust pipe, flange and lagging Repair if found damaged.
(xi) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xii) Checking of all hoses and cleanup,change/tighten if required. (xiii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiv) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 1 | Each Job | - | - |
| 3 | Material and labour for conducting ‘B’ check of DG Set 100 KVA capacity Make: Kirloskar at 183 MH & 57 MDSR, DG sets of above capacity installed at above location to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Check for any diesel lekage from any point and rectify if observed.
(v) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.
(vii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(viii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(ix) Check exhaust pipe, flange and lagging Repair if found damaged.
(x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xi) Checking of all hoses and cleanup,change/tighten if required. (xii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 2 | Each Job | - | - |
| 4 | Material and labour for conducting ‘B’ check of DG Set 62.5 KVA capacity Make: Kirloskar at 183 MH & KLP Pump House, DG sets of above capacity installed at above location to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Check for any diesel lekage from any point and rectify if observed.
(v) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.
(vii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(viii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(ix) Check exhaust pipe, flange and lagging Repair if found damaged.
(x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xi) Checking of all hoses and cleanup,change/tighten if required. (xii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 2 | Each Job | - | - |
| 5 | Material and labour for conducting ‘B’ check of DG Set 30 KVA to 45 KVA capacity Make: Kirloskar at 27 R&O Flt & E/M complaint Cell, DG sets of above capacity installed at above location to carry out maintenance / servicing as given below all as directed:-
(i) Change of diesel filter/oil filter/Air filter/top up/replacement of engine oil, coolant if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts & bolts of DG set and its accessories.
(iv) Check for any diesel lekage from any point and rectify if observed.
(v) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.
(vii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order
(viii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged.AVM to be provided by contractor.
(ix) Check exhaust pipe, flange and lagging Repair if found damaged.
(x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.
(xi) Checking of all hoses and cleanup,change/tighten if required. (xii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (Note :- Spares parts/ Engine oil/coolant /distilled water etc. will be measured and paid separately .) | 2 | Each Job | - | - |
| 6 | Supply only the following spare parts/items for DG set capacity 500 KVA complete as specified and as ditected. (Make : Kirloskar) (Note: Make of spares parts shall be of the same original manufacturer as per existing) :- (6.01) Diesel fuel filter assembly (Pre filter & Micro filter) (Set of 02 Nos) | 2 | Each set | - | - |
| 7 | (6.02) Air filter assembly | 2 | Each set | - | - |
| 8 | (6.03) V' belt as per existing make/model | 1 | Each | - | - |
| 9 | (6.04) Fuel pipe | 1 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.27 MB
BOQ_861316.xls
BOQ • 0.52 MB
TENDER8755.pdf
Tender Documents • 1.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .