Electrical work in connection with "Provision of booster pump with associated electrical work for watering facilities at TKJ in c/w train shifting from NDLS to TKJ station".
79-SRDEE-G-DLI-2026-27
79-SRDEE-G-DLI-2026-27
Open
6 Months
Unknown (Unspecified Location)
₹0
₹1.2 L
19 May 2026
19 May 2026
27 May 2026
A-Electrical work in connection with "Provision of booster pump with Above/
Supply, fixing, testing and commissioning of Pump & allied fittings Pump sets 40 HP. 1 1 set=3 Nos (Pump set of 40 HP each along with Electric motor)., total head-35 Mtrs, discharge-200 Cu.m/hr. Pump should be of standard manufacture such as M/s Kirloskar Brothers and Motors, M/s Crompton Greaves Limited or equivalent & as per explanatory note.
Supply, fixing, testing and commissioning of Pump & allied fittings Common skid Mounting for pumps sets & as per explanatory note.
Supply, fixing, testing and commissioning of Pump & allied fittings Basket type in Line strainer 200 mm. for pumps sets & as per explanatory note.
Supply, fixing, testing and commissioning of Pump & allied fittings Suction manifold with fittings & fitment work & as per explanatory note.
Supply, fixing, testing and commissioning of Pump & allied fittings Delivery manifold with fittings & fitment work & as per explanatory note.
Supply, fixing, testing and commissioning of Pump & allied fittings Butter Fly valve 150 mm & as per explanatory note.
Supply, fixing, testing and commissioning of Pump & allied fittings Non return valve 150 mm & as per explanatory note.
Pump & allied fittings Flow meter 150 MB & as per explanatory note.
Pump & allied fittings Electrical Operated valve 150 MB (Main Bore) with fittings 150 mm & as per explanatory note.
Supply, fixing, testing and commissioning of Pump & allied fittings 1.5 Sq mm 6 core copper cable & as per explanatory note.
Supply, fixing, testing and commissioning of Pump & allied fittings hydro pneumatic Tank & as per explanatory note.
Supply, fixing, testing and commissioning of Pump & allied fittings Cable for pumps to panel 16 sq. mm copper 3.5 core & as per explanatory note. 1366823.0
Supply, fixing, testing and commissioning of Electrical & Control Items Control panel inclusion of the following (i) to (ix) (i) Design, fabrication, transportation, supply, erection and commissioning of LT cubical panel 3 phase and neutral 415 V., 4 wire, free standing floor mounted, LT panel made up of 14 SWG CRCA (Cold Rolled Carbon Annealed) sheet after seven tank process and painting with EPOXY powder coating. The panel shall consist of suitable rating TPN (Triple Pole Neutral) tinned copper bus bar supported with DMC/AMC barriers and colour coded with heat shrinkable sleeves. The metering shall be provided as specified. The panel shall have short circuit with standing capacity of minimum 50 KA(RMS) power frequency test and consist of the switch gear as mentioned below. The panel shall be mounted on channels including supply and fixing as per specification. The complete work has to be carried out by the contractor including masonry work. 13 After execution, all the feeder cables have to be connected to new panel with suitable cable glands as per the requirement of the Engineer at site. Air condition provision is to be made for entire control panel. The panel consists. (ii) 1 No. of 400 A., 4 Pole, 36 KA, MCCB (Molded case circuit Breaker) & 400 A Change over for incoming. (iii)4 No. of 100 A., 10 KA 4 Pole MCCB out going. (iv)1 No. of 36 A., 10 KA 4 pole MCB (Miniature Circuit Breaker) out going. (v)1 No. of 32 A., 10 KA 4 pole MCB out going. (vi)Along with multi functional digital meter similar to model No. EM-VIFPE of M/s HPL make with suitable ratio CTs (Current Transformer) along with selector switches, LED phase indication pilot lamps (3 No's), and tinned copper bus bar of 1000 V along with rubber chequered sheets of size 1 m x length of panel of 12 mm thick as per IS 5424-1 No., complete. (vii) Suitable set of capacitor 40 KVAR with auto manual APF Relay. (viii) VFD (Variable Frequency Drive) 1 No. PLC 1 No. HMI, with pressure treasures. (ix)Suitable 40 HP star delta starter with auto manual selection mode. And same starter will work on VFD and command will be to VFD by PLC (Programmed Logic Control) & as per explanatory note.
Supply, installation, testing & commissioning of 2 KVA on line UPS with battery 72 volt, 42AH should have input, output protection complete with trolley as per relevant IS/IEC standard & as per explanatory note.
Supply, fixing, testing and commissioning of LT distribution board recessed mounting double door type made up of CRCA sheet sheet with anti corrosion treatment, IP 54 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IEC: 61439 or latest of make ABB, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IEC:60947 or latest, IE rules and 15 site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit. 40A 2P RCBO 30/100 mA= 01 No. (Incoming) 6-32A MCB SP "C" Series =18 Nos. (Outgoing) It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal, reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables & as per explanatory note.
Design, Supply, fixing, testing and commissioning of front operated double door type weather proof feeder pillar body made of CRCA sheet sheet with anti corrosion treatment and suitable having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following 16 MCCB's fixed in it of make: Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947 or latest with digital measuring instrument & bus-bar arrangement and as per IS, IE rules and site requirement. It should be dust and vermin proof, conforming to IEC:60947 and powder coating as per latest relevant IS. 4P MCCB 630Amps on load change over switch (COS)= 01 No. (Incoming) 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release = 02 No. (outgoing) 4P MCCB 125Amps 36 kA with adjustable thermal & fixed magnetic release = 04 No. (outgoing)
Supply and recessing/fixing of PVC conduit pipe of 25mm size conforming to IS:9537 Part-III:1987 (or Latest version) with accessories junction box, bends etc. including making chase, plastering/clamping etc. as per site requirement conforming to IS 9537 (Part 3) latest & as per explanatory Note.
Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi 18 stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version), and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per technical specification including connections, testing and commissioning & as per Explanatory Note. Size = 1x1.5 sq.mm.
Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi 19 stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version), and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per technical specification including connections, testing and commissioning & as per Explanatory Note. Size = 1x2.5 sq.mm
Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi 20 stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version), and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per technical specification including connections, testing and commissioning & as per Explanatory Note. Size = 1x4.0 sq.mm
Supply, fixing, testing and commissioning of following modules, GI box alongwith 21 modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per Explanatory Note. Size= 6 Module
Supply, fixing, testing and commissioning of following modules, GI box alongwith 22 modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per Explanatory Note. Size= 08 module
Supply, fixing, testing and commissioning of 6A modular type switch complete 23 including connections etc. as required as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per explanatory Note.
Supply, fixing, testing and commissioning of 16A modular type switch complete 24 including connections etc. as required as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per explanatory Note.
Supply, fixing, testing and commissioning of modular type socket 5/15A multi pin 25 complete including connections etc. as required as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per explanatory Note.
Supply, fixing, testing and commissioning of modular type 3 pin socket 5/6A 26 complete including connections etc. as required as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per explanatory Note.
Supply, fixing, testing and commissioning of 4-feet long surface mounting 36-40watt, 5700K,CRI>80, LED Luminaire as per CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev- '3') or 27 latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest, IS, IE rules and site requirement. Fitting shall be environmentally friendly, long life, corrosion resistant, impact proof IP 66 with PC housing & opal finish cover suitable for wet location similar to Make - Havells Model No. MAGNUM NEO or equivalent. Fitting shall be suitable for operation on single phase 240Volt, 50 Hz AC supply complete & as per explanatory Note.
Supply, fixing, testing and commissioning of 45-50 watt LED based street light luminary with cool white light, pressure die cast aluminum housing, IP 66 or better having system complete confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note.
Supply, fixing, testing and commissioning of 380mm sweep, 1400 rpm (approx) 29 propeller type exhaust fan complete in all respect as specification and as per site requirement, including grouting of nut, bolts, washer and with the suitable fasteners conforming to IS 2312 & IS 302 or latest and other relevant IS/IEC standards. Make Bajaj, Usha, Havells, Orient or equivalent and as per explanatory note
Supply, fixing, testing and commissioning of 400 mm sweep wall mounted fan complete conforming to relevant IS/IEC standards & as per Explanatory Note.
Supply, fixing, testing and commissioning of 25A/32A, 30mA DP RCCB AC type 31 confirming to IS12640-1 & IEC 61008-1 with 10KA short circuit with stand capacity complete with enclosure conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per Explanatory Note.
Supply, fixing, testing and commissioning of Float type mercury level switch with 12 mtr cable for On/Off as per level and as per IS & IE rule & as per explanatory note.
Supply, fixing, testing and commissioning of suction and delivery transducers fittings with pressure gauge as per site requirement and as per IS & IE rule & as per explanatory note.
Supply, installation, testing, commissioning of control panel for electrically operated through GSM based/ mobile for 4 or 5 nos. of valves with auto manual selection valve and as per site requirement. SIM to be supplied by Indian Railway along with Recharge & as per explanatory note.
Supply of one computer table, two chairs and one steel almirah size 1500 x 900 x 600 mm. (One set = one table + 02 chairs + one almirah) & as per explanatory note.
Supply, fixing and commissioning of 3 core flat PVC insulation and sheathed with 36 multistrand flexible copper conductor 1100 volts suitable for submersible pump (for maximum conductor temperature 70 deg. C to 85 deg. C approx, water proof, confirming to IS-694 latest as per IS/IE rules and site requirement) & as per explanatory note. Make: Finolex, Havells, Polycab, KEI or equivalent. 3Cx6 sqmm
Supply, fixing, testing and commissioning of Elbow of following size, 100 mm & as per explanatory note.
Supply, Fixing, Testing and Commissioning of GI nipple of 1' long of the size 100mm & as per explanatory note.
Supply, Fixing, Testing and Commissioning of MS Flange of size 4" suitable for 100 mm NRV & Gateway complete & as per explanatory note.
Supply, fixing, testing and commissioning of CI NRV of make Zoloto, Kartar, Karan or equivalent as per site requirement of following size 100 mm
Supply, fixing, testing and commissioning of ISI marked water cooled vertical type 41 monoblock submersible pumps of capacity 20 HP, 2 stage, 1450 LPM, 42 meter head, SS impellar and copper rotar and sutaible size ISI marked cable & as per explanatory note, Make Falcon, KSB, Crompton, Kirloskar or equivalent.
Supply & testing of ISI marked water cooled vertical type monoblock submersible 42 pumps of capacity 20 HP, 2 stage, 1450 LPM, 42 meter head, SS impellar and copper rotar and suitable size ISI marked cable & as per explanatory note, Make Falcon, KSB, Crompton, Kirloskar or equivalent.
Supply, fixing, testing and Commissioning of 20 HP fully automatic star-delta starter for submersible pump with overload current range 20-32amp, with single phase protection, Dry run, over voltage and under voltage, phase reversal. Make L&T MUG 20H with IADSM, Subtech, Havells, Rockwell or equivalent with all accessories and site requirement conforming to relevant IS/IEC standard & as per explanatory note.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD 44 (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 or latest fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1400mm, service value >= 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) conforming to CPWD DSR(E&M) 2025 & as per Explanatory Note.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV 45 grade of following size direct in ground including excavation((upto 75-100 cm depth and not less than 35 cm wide ), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory Note. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV 46 grade of following size direct in ground including excavation((upto 75-100 cm depth and not less than 35 cm wide ), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory Note. Above 95 sq. mm and upto 185 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation 47 including excavation(upto 75-100 cm depth and not less than 55 cm wide & maintaining gap not less than 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest and explanatory note. Above 35 sq. mm and upto 95 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation 48 including excavation(upto 75-100 cm depth and not less than 55 cm wide & maintaining gap not less than 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest and explanatory note. Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. In case of any demolition of PCC, RCC, 49 road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory Note. Above 35 sq. mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. In case of any demolition of PCC, RCC, 50 road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory Note. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Earthing with 40 mm dia GI pipe class 'B' 4.5 meter long earth electrode as per 51 IS:3043 (latest version)to achieve earth resistance less than 5 ohms including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mmx 400 mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per drawing & as per explanatory Note.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required as per IS:3043 (Latest version) and as per explanatory Note
Supplying and laying 25 mm X 5 mm G.I strip confirming to relevant IS as per IS:3043 53 (Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) & as per explanatory Note.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
TECHSPEC-IRev.3.pdf
ATTACHMENT
TECHSPEC-IIRev.4.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-11.pdf
ATTACHMENT
ExplanatoryNote-79.pdf
ATTACHMENT
TenderDocument-79.pdf
ATTACHMENT
ModifiedSpecialConditionsofContract.pdf SPECIAL CONDITIONS
ATTACHMENT
ModifiedSpecialConditionsofContract.pdf
ATTACHMENT
Download all tender documents and submit your bid