Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC 20421 STREET NO 9 AJIT ROAD BATHINDA | BATHINDA | BATHINDA | PUNJAB | L1 | Accepted-AOC L1 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
8 Jan 2020, 4:00 pmClosed
EXECUTIVE ENGINEER
EE WSS DIVN NO1, FEROZEPUR
Augmentation of Water Supply Scheme Sidhu Block Ghall Khurd Distt. Ferozepur under PRWSS sub component 1a(iii)
2019_WB_41467_1
TENDER FOR VILLAGE SIDHU UNDER 1AIII
Open Tender
Civil Works
Item Rate
390 days
FEROZEPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
TIA
₹56,000
Yes
24 Jun 2020
4 Dec 2019
9 Jan 2020
4 Dec 2019
8 Jan 2020
4 Dec 2019
Amount
Drilling trial bore using telescopic method with suitable rig to extract water samples of different strata’s encountered during drilling to check water quality with respect to Physical & Chemical Analysis, Heavy Metals & Uranium etc. The payment for testing water sample will be paid extra as per the quoted rates against relevant items of this bid. However the rates includes analysis of sand of all strata from where the water sample have been collected. (It should be ensure that the water sample is collected by an officer of rank not less than SDE)
Drilling of 600 mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site complete in all respect.
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
(b) 150mm nominal diameter (weight 21.6 kg per meter) 5.4 mm thickness
Supplying, fixing of lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest ISI Marked, Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore. (c) 150 mm internal diameter (slot size 0.75 mm) 5.00 mm thickness
Supplying, fixing and lowering of Stainless Steel Socket as per IS: 8110-2000 or latest ISI Marked, Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore complete in all respect
(a) 150 mm internal diameter
Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect.
(b) 150 mm internal diameter
Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Collection of water sample after last development testing of sample from approved laboratory (Phisical, chemical, Heavy Metal & Urenium Analysis) sample got tested from govt. lab. free of cost.
Testing of Water sample for Heavy Metal from approved laboratory (Toxic material such as arsenic, lead, mercury, pesticide etc.
Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect
(c) 150 mm internal diameter
Supplying & fixing of ball plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
(b) 150mm internal diameter (weight 21.6 kg per meter) 5.4 mm thickness
Supplying & fixing of M.S. Clamp of size 150mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Development and stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
(a) Capacity of Air compressor 300 cfm at 250 PSI
Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc. complete in all respect.
Supplying at quarry site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from dust, dirt or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per acual length of pipe)
Supplying and fixing Mild steel centring guide made out of 32mm x 6mm thick M.S. bar complete in all respect.
Constructing one No. of 25 KL (25000 litres) Capacity with sill level not less than 15.50m height upto FSL 18 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing C.I. D/F expansion joints conforming to (IS-1536-1989) or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and C.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow CI double flanged pressure pipes horizontally cast in sand moulds as per IS 7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. In case the safe bearing capacity of sail is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling within lead of 5 km, including overflow haudi complete in all respects.
Construction of Pump Chamber 2.20 X 2.20m size including Gravil Pit and cost of electric wiring as per DWSS standard design, Drawing & Analysis, complete in all respects. With gravil pit (Including Carriage of Material)
Provision for Sanitary Latrine near Pump Chamber ( as per IHHL)
Providing, Stringing out PVC pipes 10 kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width Complete in all respect. (Mechanically ) (10kgf/ cm2) Pressure.
110mm o/d PVC Pipe 10 Kg2/Cm2
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 02No. With each of Size 0.9m x 0.9m
Construction of V-NOTCH Haudi (Size 1.80 m x 0.90m ) excluding cost v-notch as per standard design and drawings of Public Health Department.
Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications.(as per AC slip no 11) for Manually Excavation including speicals (6kgf/ cm2) Pressure
63mm o/d PVC 6kg/cm2
90mm o/d PVC 6kg/cm2
Providing, Stringing out PVC pipes 6kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width. (Mechanically ) (6kgf/ cm2) Pressure
PVC pipe 63mm o/d 6Kg2/Cm2
PVC pipe 110mm o/d 6Kg2/Cm2
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. As per analysis A13
Dismantling of cement concrete road and restoration in original condition. (As per Analysis attached) 90mm o/d PVC Pipe
Contractor shall quote rates only for dismantling of metalled road and back filling with excavated earth, fully compacted. The restoration of the metalled road to its original condition will be done by the concerned department I.e PWD (B&R)/PMB/ Panchayti Raj.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 1 No. With each of Size 0.6m x 0.6m
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications. Along with 200ltr of sodium hypochlorite in container.
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set of 5.00 BHP KSB or equivalent make capable of delivering 200LPM against a head of 54.00mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 50 mm & length 40 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 85 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects
Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Annexure A12 – 2 & Drawings D-12 & D-17.
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 (as per Analysis A-8)
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. (As per Analysis).
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-9
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 & Analysis A-5 including Carriage of material
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-6 complete in all respects . including Carriage of material
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7 & Analysis A-11. including Carriage of material
Providing & fixing MS Sign Board as per standard size of DWSS as per analysis A-24 & Drawing D-20
Providing house hold connection lying, jointing, fixing, testing MDPE / G.I. pipes (as approved by Engineer-in-charge) including cost of Excavation, Refilling, C.I bib cock as per IS:210 with stainless steel spindle, 20mm o/d MDPE pipe 2.50m (length on average basis), 3"i/d clamp, G.M. ferule ISI marked, connection of 10mm i/d ferrule medium, specials such as tees, bends sockets, elbows, nipples (100mm & 150mm), Union couplings, GI hooks etc and gun metal peet valve (heavy pattern) with hand wheels on MDPE pipe lines laid in the ground or inside building, cutting threading, making hole in wall and testing in trenches in the ground all material should be ISI marked (to the approval of Engineer-in-charge) Complete Job in all respect including cost of carriage. (Refer CSR item Nos. 28.34 b, 30.65 b, 28.40 a, 28.43 a, 28.46)
O&M of scheme for 3 Month after execution of work at site. Including Sallary of Pump Operator , Electricity Bill and Bleaching Powder
Carriage of Surkhi, sand, bajri, ballast, stone, boulders, kankar, building rubbish
Carriage of material excluding initial lead of 5 Km
Fine Sand From Jalalabad (Av. Lead 60 Km)
Course Sand From Pathankot (Av Lead 225 Km.)
Bajri / Gatka From Pathankot (Av Lead 225 Km.)
Boring with 200mm i/d MS Casing pipes and withdrawing the same after completion of tubewell is required to be abunded on the bases of non availability of portable water
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .