Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹51.2 L+₹13.2 L (34.8%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Mar 2022, 6:00 pmClosed
GE AF SRINAGAR
GE AF SRINAGAR AF STN SRINAGAR 190007
REPAIR/ MAINTENANCE OF ALUMINIUM DOOR, WINDOW, FALSE CEILING, ROLLING SHUTTER, ROOF TRUSSES, GATE AND OTHER MISC WORK UNDER GE(AF) SRINAGAR
2022_MES_508414_1
GE(AF)SGR- 20 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF SRINAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) SRINAGAR
₹80,000
Yes
10 May 2022
16 Feb 2022
24 Mar 2022
16 Feb 2022
23 Mar 2022
2 Mar 2022
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 Sqm but n exc 4.00 Sqm each complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutters of any description, area exceeding 1 sqm and not exceeding 2.00 sqm each complete all as specified and as directed by Engineer-in-Charge
Resecuring or easing and adjusting without taking down shutters of any description, area exceeding 1 sqm and not exceeding 2.00 sqm each, complete all as specified and as directed by Engineer-in-Charge
M&L for Easing of Aluminium shutters of door / CB / Sliding windows shutters, area exceeding 1 Sqm but n. exe 2.5 Sqm each (One unit shall comprise of one window / CB / Showcase irrespective of number of leaves) for easing and adjusting by tightening of joints, adjustement of tower bolts, sliding bolt etc for smooth function / properly closing / opening, complete all as specified and directed.
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size, mortice lock etc all as specified below complete all as specified and directed. (a) Frame (top & side) section shall of size 101.60 x 44.75 x 2.4 mm ( Section No 14021) (b) Vertical Members of shutter Section shall be be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be be of size 83.50 x 44.45 x 2.00 mm (Section No 19581)
(d) Lock rail (Middle member) of shutter Section shall be be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be be of 0.80 mm thick (Section No 19370). Note:- (i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx A (ii) Floor door spring will be measured & paid separately.
Supply fabricate & fix in position aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) three track window ( two shutters glazed & one shutters wire gauge) with frame, glazed with 4 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below, complete all as specified and directed. (a) Frame (top & side) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20831) (b) Frame (bottom) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20832)
(c) Top & side Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55 (Section No 20738) (d) Shutter Interlock Section shall be be of size 18.00 x 40.00 x 1.45 (Section No 20737) (e) Bottom Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55 (Section No 20736) Note:- Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx A
S&F aluminium powder coated minimum thickness of power coated 50 micron of approved colour ventilator, partially glazed and partially louvers, outer frame & mullion fabricated with aluminium section of size 82.50 mm x 38.00 mm x 1.50 mm thick (Cat No 20036), half portion glazed with 4 mm thick frosted glass including rubber beading, & glazing clip, half portion louvers of 40 mm wide & 4 mm thick frosted glass with aluminium louver patti, S.S wire gauge of 0.36 mm dia and 1.40 width of aperture fixed with 25 x 3 mm think aluminium strip with screw to upper half portion of ventilator including all fitting & fixture and fixed in position complete. Note:- (i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx A
S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty / wooden beads / aluminium beading in square or rectangular area n exc 0.5 Sqm in each pane including Hacking out old broken glass complete all as specified and directed by Engineer-in-Charge. Note:- Old rubber bead / aluminium snap beading / wooden bead retrived from demolition of glass to be reused for fixing of new glass.
S&F Figured Glass pin head type 4 mm thick, ordinary quality and glazing with oil putty / wooden beads / aluminium beading in square or rectangular area n exc 0.5 Sqm in each pane including Hacking out old broken glass complete all as specified and directed by Engineer-in-Charge. Note:- Old rubber bead / aluminium snap beading / wooden bead retrived from demolition of glass to be reused for fixing of new glass.
S&F Floor door stopper of aluminium alloy body, double legged with rubber shoe fixed to door, Overall length of cover plate 100 mm all as specified and directed by Engineer-in-Charge
S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in position.
S&F in repair Aluminium (Extruded Section body) Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed
S&F in repair wooden panelling of second class softwood 12 mm thick with tongue and groove joint fixed in any position over and including wooden framework in second class softwood with plain fillets square or rectanglular in section clean sawn, secuired with nails / screws of sectional area exc 13 Sqcm and n exc 25 Sqcm at n exc 90cm centre to centre in both direction and including threee coats of french polishing on all the exposed surfaces, complete all as specifed.
Supplying, fabricating and fixing wall panelling / cladding of aluminium composite panel of any colour any type of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick mineral core sandwiched between two aluminium sheets (each 0.5mm thick ). The aluminium composite panel wall panelling / cladding sheet shall be coil coated, with Kynar 500 based PVDF lumiflon based fluoropolyer resign coating of approved colour and shade on exposed face and polymer (service) coating on the face fixed over and including base frame fabricated with aluminium square pipe of size 25 mm x 40 mm with 1 mm wall thickness including stainless steel screws, nuts bolts, washers cleats, weather silicone sealant for groove filling etc complete all as per manufacturer instruction & as directed including taking down old panelling / cladding complete.
Supply & fix in repair stainless steel letters of height exc 200 but not exc 300 mm, fabricated with 2.5 mm thick stainless steel sheet of grade 304, bright finish, fixing of letters on wall / columns / ACP sheet all directed by Engineer-in-Charge. Note:- Font of letters shall be as approved by GE.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets & snap grid complete all as specified and directed by Engineer-in-Charge.
M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre, intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
M&L for Providing and fixing Gypsum Board 12 mm thick (water proof) in ceiling fixed with screw or as per manufacturers instructions including necessary jointing and taping, complete all as specified and directed by Engr-in-Charge.
S&F snap grid for false ceiling of size 600 mm x 600 mm grid EXPOSED GRID SYSTEM fabricated with glavanised iron powder coated section all as shown on serial page No 185 of SSR part II (2020 print) complete all as specified directed by the Engineer-in-Charge.
S&F particle boards or tiles of size 600 mm x 600 mm 12 mm thick for insulation and acoustic purposes, fixed or laid / inserted to timber / GI / Aluminium framework with screws, complete all as specified and directed by Engineer-in-Charge.
S&F in repair particle boards or tiles of size 600 mm x 600 mm 12 mm thick for insulation and acoustic purposes, fixed or laid / inserted to timber / GI / Aluminium framework with screws, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new wooden surface ceiling board of any descreption over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-In-Charge.
S & F in repair Non asbestos fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 6 mm thick fixed or laid / inserted to timber / GI / Aluminium framework with screws complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previouly untreated surface of ceiling board of any descreption including cornices and applying two coats of oil bound distemper colour / tint as approved over one coat primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted ceiling surface and applying one coats of distemper oil emulsion complete all as specified and as directed by Engineer-in-Charge
S&F in repair second class hardwood fillets bullnosed, splayed, chamfered or rounded on one edge or face of sectional area exc 6 Sqcm but not exc 13 sqcm fixed with secured / nails complete all as specified and directed by Engineer-in-Charge.
S&F in repair second class hardwood fillets bullnosed, splayed, chamfered or rounded on one edge or face of sectional area exc 13 Sqcm but not exc 25 sqcm fixed with secured / nails complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any deccreption not othervise specifically provided, complete all as specified.
Demolition of cement concrete (unreinforced) in ground floor and in paving n exc 15 cm thickness (below or above ground level), complete all as specified.
M&L for hardcore of brocken stone boulder of gauge n exc 63 mm, deposited, sprade and levelled in layers n exc 15 cm thick watered and rammed to true surface.
M&L for 100 mm thick cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in Sub base for path / flooring complete all as specified and as directed.
Material & Labour for road side kerb with factory made Precast cement concrete block of mix 1:2:4 type B-1 using 20 mm graded stone aggregate, not exc 100 mm in thickness & set in CM 1:3 including making joints with or without grooves (thickness of joints except at sharp curve shall not be more than 5 mm), including making drainage opening wherever required complete.
M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge.
M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified.
Demolition of Brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
All as per item No 37 above here-in-before but except bricks. Note:- Old brick retrieved vide item No 36 above shall be reused.
M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan any radius in half brick thick wall built in cement mortar 1:4 using old size bricks complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster of any description on brick or stone masonary wall, etc including racking out joints, hacking for key, scrubbing down with water etc, all as specified.
M&L for Rendering 15 mm thick in cement and sand mortar 1:6 on brick work or cement concrete surfaces of walls including finishing the surface even and smooth with using extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete surfaces of walls including finishing the surface even and smooth with using extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L for Rendering 5 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling, including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for Preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge
M&L for applying 3 mm thick cement base wall care putty in two coats on plastered surface of wall, and making the surafce even & smooth for reciving distemper / paint of any descreption all as specified & directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over one coat of primer all as specified and directed. Note:- Cement base wall care putty where ever directed will be applied and will be measured & paid seperatly
M&L for Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge
M&L for preparation of newly plastered surfaces of walls including sides and soffits of beams, fascias, parapets etc and applying two coats of cement base paint over one coat of primer, colour and tint as ordered, complete all as specified and directed by Engineer-in-Charge.
M&L for prepation of new plastered surface of walls including sides and soffits of beams, fascias, parapets etc and applying two coats of weather proof exterior emulsion paint, over one coat primer colour and tint as ordered, complete all as specified and directed by Engineer-in-Charge.
M&L for screed bed or bedding layers of 15 mm thick for laying floors in CM 1:4 complete all as specified.
M&L for 10 mm thick rendring / backing coat in cement mortar (1:4) to receive wall tiles, complete all as specified.
M&L for rubbur molded glossy finish Chequered cement concrete tiles of size 30 cm x 30 cm x 25 mm thick, in white cement with pigment, set, jointed in neat cement slurry & pointed in coloured cement, as in floors / path / hardstanding, laid over screed bed complete all as specified and directed.
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including rubbish off the premises, all as specified..
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over screed bed.
All as per item No 54 above here-in-before but in Skirting
M&L for double charged colour vitrified ceramic tiles 10 mm thick (square) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over existing screed bed, set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L for double charged colour vitrified ceramic tiles 10 mm thick (square) polished, area of each tiles n.exc 0.36 sqm for skirting / dado etc laid over existing backing coat, set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Material and labour 1st quality vitrified parking tiles of approved shade, of size 300 mm x 300 mm x 10 mm thick as in floors / path etc, set & jointed in neat cement slurry & pointed in matching coloured polymer cement based grout to match complete. Make: Johnson Endura meteor (Korneto Biege) or equivalent make mention in Appx A.
S&F in repair 1.5 mm thich Polycarbonate sheet fixed with self tapping stainless steel screw and washer complete all as specified and directed by Engineer-in-Charge.
S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers.
S&F in repair 12 mm thick toughned glass as in doors, partitions and similar work including cutting to shape, drilling holes required and machine molding edges complete
M&L for etching on toughened glass designed and pattern as approved by Engr-in-Charge
S&F stainless steel handle 450 mm size & 25 mm dia suitable for toughened glass door complete all as specified and directed by Engineer-in-Charge.
S&F 2 levers stainless steel floor lock suitable for toughened glass door complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings Fe- 290 (Gde E- 165) (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for rolled mild steel work in roof trusses (framed), trussed, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe 410-W (Gde E-250) quality A complete all as specified and directed by Engineer-in-Charge
M&L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, wind Tie etc Fe 410-W (Gde E-250) quality A complete all as specified and directed by Engineer-in-Charge
S&F in repair MS works as in holdfast, and similar work and similar small articles conforming to Fe 290 Gde E-165, complete all as specified and directed by Engineer-in-Charge
M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
S&F in repair superior quality venetian blinds horizontal or vertical type including Powder coated hardware fitting complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint, in camouflage pattern complete all as specified and as directed by Engineer-in-Charge
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for fixing holdfasts, etc including necessary formwork, complete all as specified and directed by Engineer-in-Charge
Taking down top assembly complete (except curtain & side bracket) of rolling shutter area exc 5 Sqm but not exceeding 10 square meter each, push pull or manual type and re-fixing the same in same position after necessary repairs such as cleaning, oiling, greasing, cleaning of the side guided channels, replacement of rusted nuts and bolts, including welding / grinding as require for proper and smooth function. Note: (i) Unserviceable spare part such as suspension shaft, spring, ball bearing etc if found unserviceable will be replace with new one and the same will be measurable & paid separately under respective items of this Sch
S&F in repairs hood cover fabricated with 1 mm thick mild steel sheet, made to hexagonal square or circular contour and stiffened with angle / flat stiffeners at top and bottom edges and fixed to bracket plate as existing complete all as specified and directed by Engineer‐in‐Charge
S&F in repairs 100 mm size safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed by Engineer‐in‐Charge
S&F in repairs 150 mm size mild steel handle fabricated with mild steel flat for rolling shutter complete all as specified and directed by Engineer‐in‐Charge
Supply and fix in repairs 1.25 mm thick mild steel strip of rolling shutters made to shape for inter locking measured Flat including two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F in repairs lock plate of riveted construction fabricated with 3.15 mm thick mild steel sheet, reinforced with mild steel angle section of size 35 x 35 x 5mm size at the bottom, interlocked with bottom most lath section of curtain so as to provide contact against the cill, when closed, fitted with sliding bolts with arrangement for locking with pad locks, one handle for widths upto 2.5 m, and two handles for widths of above 2.5 m complete all as specified and directed by Engineer‐in‐Charge.
S&F in repairs 40 mm bore mild steel pipe heavy duty as in suspension shaft for rolling shutter, cut to size including necessary drilling / grinding etc complete all as specified and directed by Engineer‐in‐Charge
S&F in repair Steel rolling shutters 1.00 mm thickness of laths, push pull or manual type without ball bearing, including top cover, anchoring rod, hasp and staple, guide channel, erected in position as directed complete all as specified and directed by Engineer in charge.
S&F in repair Steel rolling shutters 1.25 mm thickness of laths, push pull or manual type without ball bearing, including top cover, anchoring rod, hasp and staple, guide channel, erected in position as directed complete all as specified and directed by Engineer in charge.
M&L Welding in repair exc 2.5 cm and n. exc 5 cm in length, thickness of metal to be welded n exc 6mm, welding of hinges, helical door spring, tower bolt clips, MS Flat in steel window for fixing wiremesh, etc complete all as specified and direcetd by Engineer-in-charge.
Dismantling of Plain or corrugated steel sheeting any gauge, thickness, in roof coverings including ridges, hips, valleys and flashings etc complete all as specified and as directed by Engineer-in-Charge.
S&F Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with hooks L type or J type or cranked hook bolts , in roofs, walls etc with grade of zinc coating 275, Complete.
All as per item No 85 but except Sheets using sheet retrived vide item No 84 above
S & F Plain, galvanised, mild steel sheeting, 0.63 mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, Complete.
M&L for Preparation of new zinc (or galvanised) steel and iron roof surfaces of any description over 10 cm width or girth to receive painting, by coating with mordant solution including washing and cleaning, etc and applying two coat of synthetic enamel paint over one coat red oxide primer in Camouflage pattern complete all as specified and directed by Engineer-in-Charge
Taking down of sliding type steel hanger doors shutters area exc 25 Sqm but n. exc 40 Sqm each leaf for reparing and refixing of shutters in same opening including cleaning of guide channel complete all as specified. Note:- repairing will be measured & paid seperatly.
S&F in repair Heavy duty Marathon Mild steel wheel, dia of wheel exc 200 mm and n.exc 300 mm and width of wheel exc 75 mm and n.exc 100 mm with mild steel plate of existing size, fixed to Hanger door shutters complete all as specified and as directed by the Engineer-in-Charge. Note:- Taking down & refixing of hangre door shutters will be measured & paid seperatly.
S&F mild steel galvanised fastener of 150 mm length and 10mm dia, fixed to concrete / masonary wall including drilling hole complete all as specified & directed
M&L for 75 mm thick PCC 1:2:4 type B2 using 40 mm graded stone aggregate as in floor, and finish the surface even & smooth without extra cement complete all as specified.
M&L for 200 mm thick PCC 1:2:4 type B2 using 40 mm graded stone aggregate as in floor, and finish the surface even & smooth without extra cement complete all as specified.
M&L for Forming contraction joints (Dummy) in concrete pavement, 25 mm deep x 10 mm wide priming & filled with sealing compound Grade 'A' all as specified and as directed.
M&L machine cut mirror polished kota stone slab flooring 20-25 mm thick as in floor, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, laid over and including 20 mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in -Charge.
M&L machine cut mirror polished kota stone slab flooring 18 - 20 mm thick as in dado / skirting, risers of steps laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, laid over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in -Charge.
M&L for Providing, plain cement concrete 1:2:4 type B1, using 20 mm graded stone aggregate, as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in -Charge.
Dismantling of timber scantlings 40 Sqcm and over in section, in any position in unframed work
S&F Second class hard-wood in scantlings, wrought faced, 40 Sqcm and over in section, in any position in unframed work complete all as specified and directed by Engineer-in -Charge.
S&F aluminium partition fabricated with aluminium powder coated (minimum thickness of powder coating 50 micron) section for side & top rail of size 101 mm x 44 mm x 2.5 mm (section 20102) for middle rail (horizontal / vertical) of size 101 mm x 44 mm x 2.5 mm (section No 20057), partly glazed with 5 mm thick tinted glass and partly paneled with 12 mm thick prelaminated particle board with both side decorative laminated including glazing clip, rubber bead, fixed in position as stander practice complete all as directed by the Engineer-in-Charge. Note:- Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx 'A'
M/S LUCKY BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .