Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.9 LAccepted-Finance | ₹29.9 L | L-1 | Accepted-Finance Responsive |
| 2 | L-2₹36.9 LRejected-Finance | ₹36.9 L | L-2 | Rejected-Finance Not-responsive |
| 3 | L-3₹37.1 LRejected-Finance SHOP NO 5 BACHAT BHAWAN UNA TEHSIL UNA HP 174303 | UNA | UNA | HP | 174303 | ₹37.1 L | L-3 | Rejected-Finance Not-responsive |
| 4 | L-4₹37.2 LRejected-Finance | ₹37.2 L | L-4 | Rejected-Finance Not-responsive |
Updated dates
Tender Value
₹35.6 L
EMD Value
₹71,100
Closing Date
30 Jan 2026, 11:00 amClosed
Executive Engineer Electrical Division HPPWD Una
Executive Engineer Electrical Division HPPWD Una
.
2026_PWD_126186_1
NIT No. 8318-8342 dated 13/01/2026
Open Tender
Electrical Works
730 days
Una
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
₹71,100
6 Mar 2026
19 Jan 2026
30 Jan 2026
19 Jan 2026
30 Jan 2026
19 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class PVC Conduit having wall thickness minimum 2.0 mm , with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make:- Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge.
Group - C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class PVC Conduit having wall thickness minimum 2.0 mm , 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make:- Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge.
Wiring for Group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor singlecore cable etc as required.Make :-Anchor (Roma classic )/ L&T(Entice)/ Legrand (Myrius) as approved by Engineer-In-Charge
Group c
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge
5/6 amp Modular switch
5 pin 5/6 amp socket outlet
Telephone socket
Modular Blanking Plate
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.Make :-Anchor (Roma classic )/ L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engieer-In-Charge.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge.
Supplying and fixing RJ 45 JACK including connections but excluding modular plate etc. as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge.
Supplying and fixing Computer board comprising 3 nos 5 amp modular switches & Sockets , G.I box 2 module for jack box and G.I Box 12 module for 5 amp switchs and 5 amp sockets comprising sheet cover for each 2 module metal box , one no computer jack (RJ-45)with shutter including connections etc as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required .Make:-Finolex/Polycab/Plaza as approved by Engineer-In-Charge
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make:-Finolex /Polycab/Plaza as approved by Engineer-In-Charge
3 x 1.5 sq. mm
3 x 4 sq. mm
Supplying and fixing of following sizes of Heavy class FRLS PVC Conduit having wall thickness minimum 2.0 mm along with accessories in surface/recess including cutting the wall and making good as required.Diplast/BEC/Polyfit.or as approved by Engineer-In-Charge(for Networking, CCTV, Fire alarm etc.)
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable,IS 7098 1.1 KV grade of following sizes on wall surface with appropriate size lugs, gland as required.Make:-Plaza/POLYCAB/Havells /Finolex as approved by Engineer-in-charge.
Armoured cable 50 sq. mm (3.5 core)
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Make:-Plaza/POLYCAB/ Havells /Finolex as approved by Engineer-in-charge.
50 sqmm (3.5core)
Supplying and fixing Ding Dong bell suitable for single phase, 230 volts, complete as required.Make :-Anchor (Roma classic )/ L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge
Providing, Installation, testing and commissioning of BLDC ceiling fan including five year warranty with socket type 2 module regulator,including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mmt win twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.Five star rating Make:- Usha (Technoaire BLDC without remote)/Orient/,Crompton as approved by Engineer-In-Charge
Ceiling Fan 1200 mm sweep
Providing and installation exhaust fan of 300mm Light duty size in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required: Make:- Usha/Orient/Crompton as approved by Engineer-in-charge(Five year warranty)
Providing and installation exhaust fan of 300 mm Heavy duty five year warranty size in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make:- Usha/Orient/Crompton as approved by Engineer-in-charge(Five year warranty)
Supplying and fixing exhaust fan louver shutter for 300 mm.exhaust fan on the existing wall,painting etc, as required,
Supply and fixing of 40 watt Round type LED fixture having system lumen efficacy of 120 lumens/watt . Housing made up stainless steel with P.F.>0.95 ,THD<10% ,CCT 6500K CRI 80, UGR<23,IP20 protection.The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 220 to 240V . Make Philips/Wipro/Jaquar as approved by Engineer-in-Charge.(five year warranty)
Supplying and fixing LED batten 10 watt (+/- 5%)Watts, with clear glass cover with Aluminium housing optical material polystyrene and optical cover material polycarbonate having efficacy 120lm/W and luminious flux 2000 lumens having P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 6500 K with CRI of minimum > 80. The Input voltage 230 volt AC . Fixture have Surge Protection 4kV complete with all accessories, connections, testing and commissioning etc. Make:- wipro /Philips/Jaquar as approved by Engineer-in-Charge (Five YEAR WARRANTY )
Supplying and fixing LED batten 35 watt (+/- 5%)Watts, with clear glass cover with Aluminium housing optical material polystyrene and optical cover material polycarbonate having efficacy 130lm/W and luminious flux 4550 lumens having P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 6500 K with CRI of minimum > 80. The Input voltage range 23O VAC . Fixture have Surge Protection 4kV complete with all accessories, connections, testing and commissioning etc. Make:- wipro /Philips/Jaquar as approved by Engineer-in-Charge (Five YEAR WARRANTY )
Supply and fixing of Led fixture 1X4FT 33 W+/- 1W with Surface Mounted aluminium housing and Polycarbonate diffuser,minimum system efficacy of 100lm/W with P.F.>0.95 with THD<20% ,CCT6500 K,CRI 80,Surge Protection 2 Kv, IP20.The LED with Useful life of 50000 Hrs at L70. The Input voltage 230 Volt AC .including ,hanging arrangement ,complete in all respect. Make Philips/Wipro as approved by Engineer-in-Charge.(five year warranty)
Supply and fixing of surface led downlighter in 12 W (+/- 5%)watts in Round Shape with minimum system lumen efficacy of 100 lm/W and total luminous flux 1500 with Pressure Die cast Aluminium hOUSING and HET diffuser and polycarbonate mounting box P.F.>0.90 ,ATHD<15% ,CCT 6500K/4000K, CRI > 80,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 220V to 240V .Fixture have Surge Protection 4 kV and inbuilt short circuit protection .Isolated Driver including ,cutting arrangement ,complete in all respect. Make:- Philips/Wipro/jaquar as approved by Engineer-in-Charge.(five year warranty)
Supply and fixing of surface led downlighter in 18 W (+/- 5%)watts in Round Shape with minimum system lumen efficacy of 100 lm/W and total luminous flux 1500 with Pressure Die cast Aluminium hOUSING and HET diffuser and polycarbonate mounting box P.F.>0.90 ,ATHD<15% ,CCT 6500K/4000K, CRI > 80,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 220V to 240V .Fixture have Surge Protection 4 kV and inbuilt short circuit protection .Isolated Driver including ,cutting arrangement ,complete in all respect. Make Philips/Wipro/jaquar as approved by Engineer-in-Charge.(five year warranty)
Supply and fixing of 2X2 Led fixture 36 W (+/- 5%)Watts surface/recess mounted fixture with CRCA Housing with white powder coating with pc diffuser having efficacy 140lm/W and luminious flux 5040 lumens having P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 6500 K with CRI > 80. The Input voltage 230 Volt AC .Fixture have Surge Protection 4kV complete with all cutting, accessories, connections, testing and commissioning etc as required :Make Philips/Wipro/Jaquar as approved by Engineer-in-Charge.(five year warranty)
Supplying and fixing 1.5 ton invertor split type air conditioner Hot and Cold with five year warranty , advanced filter ,E saver mode , quit mode, dual display ,auto clean ,anti bacteria filter jet Cool on/off timer sleep mode compressor cord less remote complete in all respect as per comprising to ISI with latest amendment suitable to operate on 230 volt /240 volt +_ 10 % AC supply capable to perform the function of cooling dehumidification air circulation ventilation and fitting in size of nominal cooling capacity and drain pipe 20 mm dia approximately 3mtrs long 2 nos copper pipe with insulator for inlet and outlet approximatey 3 mtrs long including carrigae of material with in all leads and lift. Make -Daikin (Model:FTHT50), O Genral/Mitsubsi, Voltas, LG as approved by the Engineer Charge.Warranty on product one year,on PCB five year & on compressor 10 year.
Supplying and fixing of voltage stabilizer upto 4 KVA having specification Digital display, led indicator & audible alarm, Input voltage range 130-300V, & built in protection ,over voltage ,Under volltage , overload, short circuits high temperature,and low oil levels and also have bypass switchin ,efficiency 98%,torodial core including connections, testing and commissioning as required: Make:- Microtek ,V Gaurd ,voltas , dolphin or its equivalent as approved by Er-in-charge(Warranty Three year )
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required.Make:-Usha/jaquar/Bajaj/Recold or as approved by Engineer-in-charge
25 Liter capacity water heater (Cat-A)
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-The panel should be approved /Tested from the CPRI lab.& should confirmed to IES 61439 Part I & Part II. i) 300 mm Deep
Cubical panel Overall Size(H) 1000MM X (W) 1000 MM X(D) 300 MM
Providing and fixing 160 AMP , four pole, 415 volts, On-Load change open execution in existing panel , including making connections, etc. as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty).
Supplying and fixing of MCCB Four pole following rating and breaking capacity with thermal magnet in release complete with connection ,testing and commissioning etc as required. Make:- L&T/ Legrand/Hager/ ABB as approved by Engineer-In-Charge (five year warranty)
32 amp -18KA
63 amp -18KA
Supplying and fixing , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.) Make:- L&T Cat. No. (SL96072)/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)
Single pole 5-32 amp
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of double poles in the existing MCB DB complete with connections etc. as required:-Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,10 KA residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)
Supplying and fixing of Segregated tripple pole and neutral 8 ways surface/ recess mounting, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, with provision to mount MCCB incomer, DP MCB/RCCB sub-incomer in each phase and SP MCBs as outgoing (but without MCB ’s and incomer),complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachable gland plate, cable interconnections, including earthing etc. as required.Make:- L&T/ Legrand/ Hager/ ABB as approved by Engieer-In-Charge (five year warranty)
Segregated tripple pole and neutral 8 ways
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar, detachable gland plate, interconnections, with appropriate rating copper lugs, gland , powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)
MCBDB 12WAY Double Door.
MCBDB 16WAY Double Door
Supplying and fixing copper strip bus-bars suitable for 300 Amp. 415 volts capacity 4 No. each of cross-sectional area (31.75mmx6.35mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-:
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-:
S/F indicator set R Y & B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.
S/F Shock treatment chart on the existing wall etc as required including carriage of material within all leads and lift.
supplying and fixing CT coil 600/5 amp with burden of VA 15 accuracy class -1 Make:- Automatic Electric Ltd/L&T/Legrand as approved by E-in- charge.
S/F rubber mat 1x 2 meter long 12mm thick infront of main panel as required including carriage of material with in all leads and lift.
Supplying and fixing true power make advanced earthing system having pure copper pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect. make :- True power /Earth plus/Ashloka as per best satisfaction of Engineer-in -charge.
Supplying and laying lighting arrestor 1mtr copper electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer )
Supplying and laying 20 mm X 3 mm copper strip as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit including conections,as required.Make:-D-Link/KEI/Polycab as approved by Engineer-in -charge.
Supplying and fixing Loaded Wall- Wall Mount 2u Dimensions 44 X57 X20 CM Front Glass Door(tinted,toughened) with LOCK &KEY, 2PAIRS OF I9" Mounting Rail with U-Marking welded Side walls !U Cable Manager (1) Hardware Packet (1Pkt)3 socket 5amp .power distribution Unit(1NO) . D-Link(Code No DGS-1008A) Digilink, Cisco/ as approved by Engineer-in-Charge.
Supplying and fixing D- link DGS-1008 A 8-port 10/100/1000Mbps Unmanaged standalone gigabit switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .Make:- D-Link(Code No DGS-1008A) Digilink, Cisco as approved by Engineer-in-Charge.
Supply and fixing of IP20 Smart PIR Occupancy Sensor having 360 degree Detection Pattern with maximum dectection Diameter of 6 meters at maximum height of 4.5 meters haviing Power consumption of 1.8 Watt with Off Delay Timing of 1-90 minutes complete with all accessories, connections, testing and commissioning etc.as required. complete with all accessories, connections, testing and commissioning etc.as required. Make Philips/Wipro/Osram/Jaquar/panasonic as approved by Engineer-in-Charge.(five year warranty)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined withconnectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.Make Legrand/ MK as approved by Er in charge.
100 mm width X 50 mm depth X 1.6 mm thickness
Providing and commissioning of self supporting stool type ladder heavy duty made out of aluminium section of 115 mm ribbed nonislip steps with large plateform of size 482x380 mm ,150mm brake type tyre castors for easy movement ,handrails 1 meter railing height from plateform for climbing comfort,guard rail 1 meter railing height from plate form complete in all respect as required. Required size
8 ft Height.
Supplying and fixing of DLP 105x50 mmPVC adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap .Make:-Legrand /MK as approved by Engineer-in charge.
Supplying and fixing Surge protection device protection against indirect/direct lighting surges maxiumum dicharge current- I max upto 50 KA/ 3 pole+neutral Type 1+2 .Make :L&T(AUSP 121PN50)/Legrand /Hager/ ABB as approved by Engineer-in -charge.
Supplying and laying of HDPE Pipe 90 mm dia for supplying and drawing of armoured cable complete in all respects as required.Make :-Duke/Dolphin /Poly
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.42 MB
SBD.pdf
Tender Documents • 4.25 MB
BOQ_185996.xls
BOQ • 0.33 MB
undertaking.pdf
Additional Documents • 0.38 MB
Download all tender documents and submit your bid