Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59,963Accepted-AOC NO 22 AISHWARIA COMMERCIAL COMPLEX 196 T V SWAMY ROAD WEST RS PURAM COIMBATORE TAMIL NADU 641002 | COIMBATORE | TAMIL NADU | 641002 | ₹59,963 Quoted ₹59,962.88 | L1 | Accepted-AOC Lowest Bid Amount |
| 2 | L1₹69,288Accepted-AOC | ₹69,288 Quoted ₹69,288.42 | L1 | Accepted-AOC Lowest Bid Amount |
| 3 | L2₹1.3 LRejected-Finance 1 23 10 ROJA FIRST STREET ALAMEEN NAGAR SURVEYOR COLONY MADURAI 625 007 | MADURAI | TAMIL NADU | 625007 | ₹1.3 L | L2 | Rejected-Finance Highest bid amount quoted |
| Sl No | Description | Qty | Unit | GM ELECTRONICS L3 | Bright Power Solutions L1 | I square systems L2 |
|---|---|---|---|---|---|---|
| 1.00 | FUNCTION GENERATOR
• Frequency range: 0.1 Hz to 5 MHz
• Display: 4 to 6 digit LED display
• Output waveforms: Sine, triangle, square,
± pulse, ± ramp
.• Amplitude: 0–20 Vpp.
• Rise time: < 100 ns.
• Distortion: < 1% within specified frequency range
• Power supply: 230 V ac±10%, 50–60 Hz.
• Output amplifier protection: Short-circuit and ±15 V | 2 | No | 53,114 ₹62,674.52 | 51,016 ₹60,198.88 | 50,816 ₹59,962.88 Lowest |
| 2.00 | Strain Gauge Trainer Kit
•AC mains power supply: 230 V ±10%, 50 Hz
• Metal foil strain gauge mounted on
beam/cantilever.
• Strain measurement under applied load.
• Wheatstone bridge arrangement.
• Signal conditioning and amplification circuit.
• Instrumentation amplifiers with 3½ digit display for strain / output voltage.
• Zero and gain adjustment controls.
• Provision for applying calibrated loads.
• Table-top trainer with labelled panel.
• Test points for signal measurement.
• Built-in DC power supplies and wooden closed cabinet.
• Supplied with patch cords and User manual. | 1 | No | 9,000 ₹10,620 | 8,378 ₹9,886.04 Lowest | 8,468 ₹9,992.24 |
| 3.00 | TEMPERATURE MEASUREMENT KIT
• Sensors:
RTD (PT-100), Thermocouple (Fe-K/J-type), and/or Thermistor (NTC).
• Display: 3½ digit LED/LCD digital display
(typically 200 mV FSD).
• Temperature source: Portable water kettle or
heater block.
• Signal conditioning: On-board circuitry for
amplification, linearization, and cold junction
compensation.
• Test points: Multiple 2 mm / 4 mm banana sockets for monitoring input/output signals.
• Power supply: 230 V ac, 50 Hz, single-phase.
• Accessories: Glass thermometer, 10 k NTC
thermistor probe, K-type thermocouple probe,
patch cords and User manual. | 1 | No | 8,950 ₹10,561 | 8,325 ₹9,823.5 Lowest | 8,470 ₹9,994.6 |
| 4.00 | Cathode Ray Oscilloscope
Bandwidth: DC to 30 MHz (-3 dB)
- Sensitivity: 1 mV/div to 5 V/div
- Display Modes: CH1, CH2, Dual
(CHOP/ALT), Add, Sub
- Timebase: 0.2 μs/div to 0.5 s/div
(essential for slow bio-signals)
- Magnification: X 10 Sweep Magnifier
- Triggering: Alt Triggering, Auto, Norm, - TV-V/H with Source Selection (CH1, CH2, Line, Ext).
- Input Impedance: 1 MOhm || 25pF
- Included Accessories: Two 60 MHz
passive probes, Power Cord, and
User Manual | 2 | No | 42,600 ₹50,268 | 42,016 ₹49,578.88 Lowest | 42,370 ₹49,996.6 |
Tender Value
Refer Docs
Closing Date
9 Jun 2026, 4:45 pmClosed
The Principal
GPTC Chekkanurani Madurai
Purchase of Equipments for ECE Department
2026_DoTE_678345_1
2535/A1/2026
Limited
Electronics Equipment
Supply
GPTC Chekkanurani
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
27 Jul 2026
26 May 2026
10 Jun 2026
26 May 2026
9 Jun 2026
26 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | FUNCTION GENERATOR
• Frequency range: 0.1 Hz to 5 MHz
• Display: 4 to 6 digit LED display
• Output waveforms: Sine, triangle, square,
± pulse, ± ramp
.• Amplitude: 0–20 Vpp.
• Rise time: < 100 ns.
• Distortion: < 1% within specified frequency range
• Power supply: 230 V ac±10%, 50–60 Hz.
• Output amplifier protection: Short-circuit and ±15 V | 2 | No | - | - |
| 2 | Strain Gauge Trainer Kit
•AC mains power supply: 230 V ±10%, 50 Hz
• Metal foil strain gauge mounted on
beam/cantilever.
• Strain measurement under applied load.
• Wheatstone bridge arrangement.
• Signal conditioning and amplification circuit.
• Instrumentation amplifiers with 3½ digit display for strain / output voltage.
• Zero and gain adjustment controls.
• Provision for applying calibrated loads.
• Table-top trainer with labelled panel.
• Test points for signal measurement.
• Built-in DC power supplies and wooden closed cabinet.
• Supplied with patch cords and User manual. | 1 | No | - | - |
| 3 | TEMPERATURE MEASUREMENT KIT
• Sensors:
RTD (PT-100), Thermocouple (Fe-K/J-type), and/or Thermistor (NTC).
• Display: 3½ digit LED/LCD digital display
(typically 200 mV FSD).
• Temperature source: Portable water kettle or
heater block.
• Signal conditioning: On-board circuitry for
amplification, linearization, and cold junction
compensation.
• Test points: Multiple 2 mm / 4 mm banana sockets for monitoring input/output signals.
• Power supply: 230 V ac, 50 Hz, single-phase.
• Accessories: Glass thermometer, 10 k NTC
thermistor probe, K-type thermocouple probe,
patch cords and User manual. | 1 | No | - | - |
| 4 | Cathode Ray Oscilloscope
Bandwidth: DC to 30 MHz (-3 dB)
- Sensitivity: 1 mV/div to 5 V/div
- Display Modes: CH1, CH2, Dual
(CHOP/ALT), Add, Sub
- Timebase: 0.2 μs/div to 0.5 s/div
(essential for slow bio-signals)
- Magnification: X 10 Sweep Magnifier
- Triggering: Alt Triggering, Auto, Norm, - TV-V/H with Source Selection (CH1, CH2, Line, Ext).
- Input Impedance: 1 MOhm || 25pF
- Included Accessories: Two 60 MHz
passive probes, Power Cord, and
User Manual | 2 | No | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_814978.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .