Loading
Loading…
Loading…
Tender Value
Refer Docs
Closing Date
9 Jun 2026, 4:45 pm5d left
The Principal
GPTC Chekkanurani Madurai
Purchase of Equipments for ECE Department
2026_DoTE_678345_1
2535/A1/2026
Limited
Electronics Equipment
GPTC Chekkanurani
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
26 May 2026
26 May 2026
10 Jun 2026
26 May 2026
9 Jun 2026
26 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | FUNCTION GENERATOR
• Frequency range: 0.1 Hz to 5 MHz
• Display: 4 to 6 digit LED display
• Output waveforms: Sine, triangle, square,
± pulse, ± ramp
.• Amplitude: 0–20 Vpp.
• Rise time: < 100 ns.
• Distortion: < 1% within specified frequency range
• Power supply: 230 V ac±10%, 50–60 Hz.
• Output amplifier protection: Short-circuit and ±15 V | 2 | No | - | - | item1 |
| 2 | Strain Gauge Trainer Kit
•AC mains power supply: 230 V ±10%, 50 Hz
• Metal foil strain gauge mounted on
beam/cantilever.
• Strain measurement under applied load.
• Wheatstone bridge arrangement.
• Signal conditioning and amplification circuit.
• Instrumentation amplifiers with 3½ digit display for strain / output voltage.
• Zero and gain adjustment controls.
• Provision for applying calibrated loads.
• Table-top trainer with labelled panel.
• Test points for signal measurement.
• Built-in DC power supplies and wooden closed cabinet.
• Supplied with patch cords and User manual. | 1 | No | - | - | item2 |
| 3 | TEMPERATURE MEASUREMENT KIT
• Sensors:
RTD (PT-100), Thermocouple (Fe-K/J-type), and/or Thermistor (NTC).
• Display: 3½ digit LED/LCD digital display
(typically 200 mV FSD).
• Temperature source: Portable water kettle or
heater block.
• Signal conditioning: On-board circuitry for
amplification, linearization, and cold junction
compensation.
• Test points: Multiple 2 mm / 4 mm banana sockets for monitoring input/output signals.
• Power supply: 230 V ac, 50 Hz, single-phase.
• Accessories: Glass thermometer, 10 k NTC
thermistor probe, K-type thermocouple probe,
patch cords and User manual. | 1 | No | - | - | item3 |
| 4 | Cathode Ray Oscilloscope
Bandwidth: DC to 30 MHz (-3 dB)
- Sensitivity: 1 mV/div to 5 V/div
- Display Modes: CH1, CH2, Dual
(CHOP/ALT), Add, Sub
- Timebase: 0.2 μs/div to 0.5 s/div
(essential for slow bio-signals)
- Magnification: X 10 Sweep Magnifier
- Triggering: Alt Triggering, Auto, Norm, - TV-V/H with Source Selection (CH1, CH2, Line, Ext).
- Input Impedance: 1 MOhm || 25pF
- Included Accessories: Two 60 MHz
passive probes, Power Cord, and
User Manual | 2 | No | - | - | item4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_814978.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid