| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.8 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹89.1 L+₹7.3 L (8.97%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹97.5 L+₹15.7 L (19.3%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹99.6 L+₹17.8 L (21.8%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | Rejected-Technical FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | - | Rejected-Technical Rejected, due to requisite category not found |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
3 Apr 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
AUGMENTATION OF EXTERNAL SERVICES NEAR BUILDINGS NO R 32 AND R 33 AT RS AREA AND AUGMENTATION OF ELECTRICAL SUPPLY NEAR BUILDING NO R 29 AT RS AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2022_MES_571032_3
8303/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (NW) Navy Nagar, Colaba
Class C and Category b(i)
and b(ii)
8 documents required · 8 mandatory
₹1,000
GE NW NAVY NAGAR COLABA MUMBAI
₹1.6 L
Yes
11 May 2023
14 Mar 2023
4 Apr 2023
14 Mar 2023
3 Apr 2023
21 Mar 2023
14 Mar 2023 - 27 Mar 2023
Amount
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. and getting out Hard/ dense soil complete all as specified and directed by Engr-in-charge.
All as per item No 01 above but exc.1.50m and n.exc. 3.00m depth.
M & L for 150mm internal dia salt glazed stone-ware drain pipe Grade'A' laid in trenches and jointed complete all as specified and directed by Engr-in-charge.
M & L for RCC drain pipes,150 mm dia confirming to class NP3, laid in trenches and jointed with collars complete all as specified and directed by Engr-in-charge.
M & L for RCC drain pipes, 200 mm dia confirming to class NP3, laid in trenches and jointed with collars complete all as specified and directed by Engr-in-charge.
M & L for RCC drain pipes, 300 mm dia confirming to class NP3, laid in trenches and jointed with collars as specified and complete all as specified and directed by Engr-in-charge.
M&L Cement concrete bed to drain pipe and packing under haunching against side of pipes after laying in PCC (1:3:6) type C-2 using 40mm graded stone aggregate for 150mm dia pipe complete all as specified and directed by Engr-in-charge.
All as per item No 7 above but for 200 mm dia pipes
All as per item No 7 above but for 300 mm dia pipes
M & L Brickwork with subclass ‘B’ bricks (old size), straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed by Engr-in-charge.
M&L Plain cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping / kerbs / surface chanel etc including necessary form work including weathering slightly rounded or chamfered angles and throating as directed complete
M & L Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces of wall finished surface fair and even complete all as specified and directed by Engr-in-charge.
S&F prefabricated cast iron work grade FG 150, unmachined in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors. dampers, stop valve boxes, balusters and similar works (weight of each articles exceeding 5 kg) complete all as specified and directed by Engr-in-charge.
M&L for Hard core of broken stone / boulders, broken to gauge n exc 63mm complete all as specified and directed by Engr-in-charge.
M&L for Cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in sub base, plinth protection, mass concrete, Pavings, hardstanding etc complete all as specified and directed by Engr-in-charge.
M&L for Machine pressed precast concrete interlocking paver block with grey cement & pigment, glossy finish (reflective type, any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, as in pavements to required level & gradients, set, jointed with clean dry sand and cushioning complete all as specified and directed by Engr-in-charge. (Note : Sand cushioning shall be measured and paid separetely).
M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm in any type of soil all as specified. ( For item No 1 & 18 above, rate deemed to be included for earth work and form work required as per site requirement & as directed by Engineer-in-Charge.
Removing demolished/excavated materials and debris laid at Navy Nagar outside MD land .
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removal of debris out side MD land all as specified.
M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of CI pipes, foundation and hardstanding finishing even and fair without using extra cement all as specified.
Removing excavated material exc 250m but n.exc 500m and depositing where directed all as specified.
M & L for CI specials confirming to IS - 1538, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 100/150 mm bore pipes (joints and joining material shall be measured and paid seperately)
M & L for DI specials confirming to IS - 9523:2000, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 150/200 mm bore pipes (joints and joining material shall be measured and paid seperately)
M & L for run lead joint with pig lead including pumping out / bail out water and necessary excavation and earth work in any type of soil,to repair the joints for following sizes of pipes :-
150 mm bore
100 mm bore
M & L for Cutting existing DI pipes and reducing for insertion of DI fittings to required length in position for following sizes :-
200 mm bore
150 mm bore
M & L for Cutting existing cast iron pipes and reducing for insertion of CI fittings to required length in position for following sizes :-
150 mm bore
100 mm bore
S&F sluice valves flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class P N 1.6, confirming to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts, washers welding works complete including pumping out accumulated water all as specified and directed of following size.
150 mm bore
100 mm bore
M & L construction of brick masonery valve chamber of size 1.2 x 1.2 x 1.2 M (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified. (Note:- Necessary excavation, returning filling and removal of debris included in item rate)
Supply and fix cast iron pipes with spigot and socket centrifugally cast class `LA' in any length laid in trenches including nut, bolts, washer, gasket, welding work etc of following sizes.
150 mm bore
100 mm bore
Supply and fix DI pipes with spigot and socket centrifugally cast class `K9' in any length laid in trenches including nut, bolts, washers, rubber gasket, flanges, welding works etc of following sizes.
200mm bore
150mm bore
Supply/ Fixing of steel water tubing, galvanised, Medium grade 80 mm dia with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece of full length.
Supply and fix gun metal gate valve 80 mm dia with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified.
Material and labour for rubber gasket joint of following sizes complete all as specified and directed
200 mm bore
100 mm bore
Suplly, installation, commissioning and testing of minimum capacity of 630 KVA 11KV/433Volt or next nearest higher capacity as per OEM design, prefabricated HV/LV Sub- Station, factory made, designed, tested and ready to install and fully confirming to IES- 62271-202 (IES 61330), outdoor type, IP-54, enclosure made with high quality pre-galvanised steel sheet 2mm thick for load bearing and 1.5mm thick for non-load bearing members, tropicalised to meet Indian weather conditions, including all the partition sheets & doors with base of the enclosure of 4mm thickness. with following below items, with and including cable ducting from RMU to transformer and transformer to LT panel and capacitor panel inside the Substation, with and including all civil foundation work all as per OEM/manufacturer's recommendations, illuminations and power sockets inside the substation, necessary radium stickering work / danger notice board indication as per IS. complete all as per manufactureres instructions and all specified and directed by Engineer-in-charge. Prefabricated Sub station shall be consist of the following fittings:-
A) 11KV, SF6 Ring main Unit 3 way Complete with non extensible motorised operated, indoor 2 Nos 630 Amp load break switch as incomer & 1 No 630 Amp Vacuum circuit breaker as outgoing with self powered DPX relays. RMU shall be with STC 21 KA for 3 sec & with internal Arc of atleast 20 KA for 1 sec for both tank and cable box. RMU tank shall be made of 2mm thick stainless steel with manual TIG welding & with front cable termination, RMU coupling shall be from side only, complete all as specified and directed by Engineer-in-Charge.
B) Transformer double wound, step down, 11000/433 volts, oil type, minimum 630 KVA capacity or next nearest higher capacity as per OEM design, ONAN, Dyn 11, core type with copper conductor. Oil immersed ONAN suitable for Unitized substation housed in a enclosure with corrugated tank arrangement hermetically sealed. Transformer shall be provided with Off circuit Rotary type tap switch so as to provided for a voltage adjustment on H.V, from +5% to -5% (in step of 2.5%) of rated voltage of 11000 voits in 4 equal steps (5 position) to obtain rated voltage of 433 volts on LV side including cable box on LT and HT side , with 12 KV system highest voltage at HV side, 28 KV (rms) HV power frequency, 75 kVp HV impulse withstand voltage, trasnformer shall be designed for losses as per IS 1180 Part 2 Efficiency level II and for 110% continuous overfluxing withstand capaibility, complete with first fill of new transformer oil having dielectric strength not less than 60 KV, suitable mounting arrangement complete and other standard accesssories all as per IS:1180 (Part 1) : 2014 specification.
(viii) Digital multifunction meter -01 set with RS 485 with LAN port hub complete with remote monitoring system with GPRS/GSM modem with SIM card and 2 year data charges complete fo monitoring all parameters such as Voltage/current/KW/ KVAh/KWh, PF frequency etc as per OEM design (ix) Control wiring shall be of minimum 2.5 sqmm PVC copper conductor cable with proper colour code. (x) The enclosure to be tested for Internal Arc fault test for atleast 20 KA for 1sec confirming to IEC 62271-202. The temperature rise test for enclosure K 10 class. Note: (i) The Contractor shall submit technical specifications and General Arrangement drawings of OEM for approval before placing order. (ii)The Contractor shall make all necessary arrangements for pre-despatch inspection at manufacturer site for pre-commissioning test as per IS by rep of Accepting Officer. Commissioning test will be carried out in the presence of Engineer-In-Charge and electrical inspector of the deportment. The cost for the same is deemed to be included in quoted rate.(iii) The quoted rate as per IS inclusive earth work for foundation, Cement concrete foundation as per OEM design, necessary T&P for transportation and installation complete.(iv) The quoted rate inclusive of supply of PSS of next nearest higher capacity as per OEM design without any extra cost.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 95 Sqmm 3 Core and complete all as specified and directed by Engineer -in -Charge Make: Polycab/Havells/Gloster/KE
Supply and fix cable jointing kit, End Termination Joint indoor for 11KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 95 sq mm complete all as specified and as directed by Engineer-in-Charge. Make- Raychems, Densons, M Seal, Birla - 3M
Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 300 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls by proper clamping complete including connecting properly by means of thimbles/lugsand, cable glands etc all as directed by the Engr-in-Charge. Make: Polycab/Havells/Gloster/KEI
Same as Item No 38.00 above but size 185 Sq mm, 3.5 core
Same as Item No 38.00 above but size 120 Sq mm, 3.5 core
Same as Item No 38.00 above but size 95 Sq mm, 3.5 core
Same as Item No 38.00 above but size 35 Sq mm, 3.5 core
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
Supply, filling, spreading levelling and well ramming the river sand around cable in trenches for cable cushioning all as specified and directed. Note : Punned thickness shall be measured and paid.
Supply and laying un-reinforced pecast concete cable covers class LV, Type 1, flat, size 250mmx 150mm x 40mm all as specified and directed.
Cutting existing road surface or hard standing, bituminous topping 15 cm but n exc 30cm girth for laying of pipes/ cables and making good distrubed surface to match with existing complete.
M & L for cement concrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in foundations, filling and mass concrete finished fair and even comlpete all as specified
M&L for GI pipe ,light grade 80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
M&L for GI pipe, light grade 100mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M & L for fixing of old interlocking paver tiles/blocks of any sizes recovered form item SI. No. 43 including laying over 50 mm thick sand bed compacted complete as specified and directed.
M & L for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of existing size and existing type and including laying over 50 mm thick sand bed compacted complete as specified and directed. ( Note : The quoted rate inclusive of cost of sand cushioning)
M&L for High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 40mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 75mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 100/110mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
Supply and fix cable jointing kit Straight Through Joint for 1.1KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
Supply and fix cable jointing kit Straight Through Joint for 1.1KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
M&L for supply installation and testing of LT panel board, factory made pedestal cubical double door outdoor type, CPRI approved, modular construction fabricated out of 3.15 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front & back side opening system including air louvers at both side, rain shed 15 cm all around, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x400mm ), platform mounted having minimum clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 50x50x5 mm thick, front and rear opening with double shutter and having locking arrangement with 50 mm lock make Navtal or Harrison with three keys and including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Standard/ Legrand)
Incoming: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 250 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, Reshab or L&T. (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 40x6mm suitable length-04 Nos
Outgoing: - (i) MCCB 100 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (ii) MCCB 63 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No.s Make: Schneider, L&T or Legrand. (iii) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note :- Before fabrication of panel, the contractor has to take approval from accepting officer on drawing.
M&L for supply installation and testing of LT panel board, factory made pedestal cubical double door indoor type, CPRI approved, modular construction fabricated out of 2.00 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front & back side opening system including air louvers at both side, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x400mm ), platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 50x50x5 mm thick, front and rear opening with double shutter and having locking arrangement with 50 mm lock make Navtal or Harrison with three keys and including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Standard/Legrand)
Incoming: - (i) Air circuit breaker, 1600 Amps, 50 kA,, FP, manual draw out type, with LCD display 4 Nos aux contact, fault trip indication, shunt trip coil mechnical interlocking with lock and key arrengements complete all as specified. (ii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability - 01 Nos. (iii) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, Reshab or L&T. (iv) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (v) Tinned copper bus bar strips made of copper of size 40x10mm suitable length-04 Nos
Outgoing: - (i) MCCB 400 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No.s (ii) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No.s (iii) MCCB 100 Amp 4 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02No.s (iv) All outgoing MCCB shall be connected through spreader and copper strip not less than 5 mm thick strip. Note :- Before fabrication of panel, the contractor has to take approval from accepting officer on drawing.
M & L for earthing with copper earth plate electrode 600mm x 600mm x 3.15 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to the connecting copper strip 20 x 3 mm and including GI pipe 40 mm dia light grade for protection to the extend of 7.5 mtr as earthing lead by means of copper nuts, bolts as per connecting to equipment with provn charcol and salt complete all as per electric plate No 5 of SSR Part-1 including PCC chamber with RCC cover watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion complete.
M & L for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm and Earthpit with cover returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces after taking out old/unserviceable one complete and testing on completion all as specified and directed by Engr-in-Charge
Shree Ayyappa Engineering
AGRAWAL ASSOCIATES
NOEL ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .