Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 CrAccepted-AOC | ₹9.2 Cr | L1 | Accepted-AOC BEING LOWEST AND REASONABLE TENDER |
| 2 | L2₹11.0 Cr+₹1.8 Cr (19.8%)Rejected-Finance | ₹11.0 Cr+₹1.8 Cr (19.8%) | L2 | Rejected-Finance NOT BEING THE LOWEST |
| 3 | L3₹11.4 Cr+₹2.2 Cr (24.0%)Rejected-Finance | ₹11.4 Cr+₹2.2 Cr (24.0%) | L3 | Rejected-Finance NOT BEING THE LOWEST |
| 4 | L4₹11.6 Cr+₹2.5 Cr (26.9%)Rejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹11.6 Cr+₹2.5 Cr (26.9%) | L4 | Rejected-Finance NOT BEING THE LOWEST |
| 5 | Rejected-Technical B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | - | - | Rejected-Technical Not meeting eligibility criteria as per NIT for unelisted firm. Under Govt work experience and Average Annual turnover for last 2 years. |
Tender Value
₹7.9 Cr
EMD Value
₹7.2 L
Closing Date
2 Aug 2019, 6:00 pmClosed
CE (NAVY) MUMBAI
26, ASSAYE BUILDING, COLABA MUMBAI - 400005
PROVISION OF SINGLE LIVING ACCOMODATION FOR TRAINEE JUNIOR SAILORS AT INS HAMLA
2018_MES_220774_3
87710
Open Tender
Civil Works
Lump-sum
600 days
BHANDUP
As tender document
9 documents required · 9 mandatory
₹3,000
Yes
GE (P) BHANDUP
₹7.2 L
Yes
24 Mar 2020
4 Jul 2019
9 Aug 2019
4 Jul 2019
2 Aug 2019
19 Jul 2019
5 Jul 2019 - 8 Jul 2019
Amount
SCH 'A' PART-I "BUILDINGS & STRUCTURES" Total of Schedule 'A' Part-I B/F from Serial Page No.32
SCH 'A' PART- II "SITE CLEARANCE, EXCAVATION & EARTH WORK. Total of Schedule 'A' Part-II B/F from Serial Page No. 33
SCH 'A' PART-III "INTERNAL WATER SUPPLY" Total of Schedule 'A' Part-III B/F from Serial Page No. 35
SCH 'A' PART-IV "INTERNAL ELECTRIFICATION" Total of Schedule 'A' Part-II B/F from Serial Page No. 38
SCH 'A' PART-V "ROAD/ HARDSTANDING/ CULVERTS" Total of Schedule 'A' Part-IV B/F from Serial Page No. 40
SCH 'A' PART-VI "AREA DRAINAGE" Total of Schedule 'A' Part-V B/F from Serial Page No. 41
SCH 'A' PART- VII "SEWAGE DISPOSAL" Total of Schedule 'A' Part- VII B/F from Serial Page No.43
SCH 'A' PART-VIII "EXTERNAL WATER SUPPLY" Total of Schedule 'A' Part-VI B/F from Serial Page No. 45
SCH 'A' PART-IX "EXTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-VI B/F from Serial Page No. 47
SCH 'A' PART-X "HOT WATER SUPPLY " Total of Schedule 'A' Part-VI B/F from Serial Page No. 49
SCH 'A' PART- XI " MISCELLANEOUS ITEMS"
INTERNAL ELECTRIFICATION
Supply and fixing energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of 5:29 1.5 sqmm from ceiling rose to ceiling fan complete In all respect all as specified and directed Make : Havells Model No ES-50 premium or equivalent in Orient / Polar
Supply and fixing heavy duty metallic body with metallic blades legs, ISI marked energy efficient BEE five star rated exhaust, 450 mm sweep with louvers and connecting up including provision of three core flexible copper wire of size 1 5 sqmm from ceiling rose to exhaust fan complete in all respect all as specified and directed. Make : Bajaj / CG
Supply and fixing heavy duty metallic body with metallic blades legs, ISI marked energy efficient BEE five star rated exhaust, 225 mm sweep with lovers and connecting up including provision of three core flexible copper wire of size 1 5 sqmm from ceiling rose to exhaust fan complete in all respect all as specified and directed. Make : Bajaj / CG
Supply and fixing MCB, SPN, 6-40 Amps, 240 Volt 50 HZ. 10 KA, ‘C‘ series including making electrical connection with the help of Iugs / thimbles all as specified and directed. Make: Siemens / Legrand / ABB / HaveIls / C&S
Supply and fixing MCB, SP, 06.32 Amps, 240 Volt 50 HZ. 10 KA, ‘C‘ series including making electrical connection with the help of Iugs / thimbles all as specified and directed. Make: Siemens / Legrand / ABB / HaveIls / C&S
Supply and fixing MCCB, TPN, 63 Amps, 415 Volt 50 HZ. 16 KA, having fixed thermal and overload rating including making electrical connection with the help of Iugs / thimbles all as specified and directed. Make: Siemens / Legrand / ABB / HaveIls / C&S
Supply and fixing RCBO of 2 Pole, 25 Amp rating with sensitivity of 30 mA suitable for 240 Volts all as specified and directed. Make: Siemens / Legrand / ABB / HaveIls / C&S
Supply and fixing 1x18 watts LED light fitting 230 volt indoor with Integral sleek extruded polycarbonate LED channel with acrylic cover suitable for surface / wall mounting with inbuilt electronic control gear, bipin holders, connector block etc complete with all accessories internally pre wired and including connecting lead, three core 1.5 Sqmm, FRLS flexible copper multistranded conductor cable from ceiling rose to tube light fitting complete all as specified and directed. Make: BN108C LED COS PSU CDL WH of Philips or equivalent in Wipro/Jaquar.
Supply and fixing 1x10 watts LED light fitting 230 volt indoor with Integral sleek extruded polycarbonate LED channel with acrylic cover suitable for surface / wall mounting with inbuilt electronic control gear, bipin holders, connector block etc complete with all accessories internally pre wired and including connecting lead, three core 1.5 Sqmm, FRLS flexible copper multistranded conductor cable from ceiling rose to tube light fitting complete all as specified and directed. Make: Bajaj Cat Part No. BCLSB 18 WH or equivalent of CG / Phillips / Wipro.
Supply and fixing angular holder, PVC body including LED lamp 5W complete with wring etc complete all as specified and directed. Make : Bajaj / CG / Philips / Wipro or equivalent.
S&F LED security light fitting luminaire 1 x 45 watts Integral, as per IS 16102 part II 2012 with Single piece, pressure due cast aluminium housing with efficiently designed heat sink to deliver proper thermal management and heat resistant toughened glass fixed with SS screw, ingress Protection IP-66, prewired complete set including bracket made of GI pipe light grade 50mm dia bent to required shape of 1 5 m length along with the clamps and nuts bolts for fixing the bracket to the pole including electrical connection etc complete all as specified and directed. Make: - Bajaj cat part No BRTFG 45W LED or equivalent in Wipro / Philips
Supply, installation,, Testing and commissioning LT Panel indoor type cubical panel board IP 52 free standing floor mounted made out of 2 mm thick CRCA sheet, duly powder coated, compartmental design with looking arrangements weather and vermin proof with proper ventilation slots complete of suitable size and comprising of following items:-
(a) INCOMER (i) MCCB 160 Amps 415V 36 RA 4 pole -1No (b) OUTGOING (i) MCB TPN 63 Amps 415V 16 kA 4 pole 04 Nos (ii) RCBO 2P 25 Amps 415V 30 MA 1 Nos. (c) BUS BAR (i) 250 Amps TPN with colour coded heat shrinkable sleeve
INTERNAL WATER SUPPLY
Supply & fixing gun metal globe or gate valve 40 mm dia with iron wheel hand screwed both ends for GI pipe conforming to IS-778 with ISI marked including required fittings and one union with each valve for easy maintenance complete all as specified and directed.
S&F for concealed stop cock 15 mm dia extra heavy body with adjustable wall flange
S&F angular stop cock 15 mm dia
S&F Health faucet with flexible pipe
S&F two way bib tap 15mm dia
" EXTERNAL WATER SUPPLY"
Supply and fix sluice valve of size 80 mm long type with cast iron body bonnet wedge stuffing box gland thrust plate hand wheel of grey cast iron spindle of stainless steel nut body seal ring and wedge facing ring lead tin, bronze bolt nut of high carbon steel bounate gasket of compressed fibre glands packing of jutehaving flanged & drill type nominal pressure rating, PN 1 i.e 10 kgs/Sqcm unit conforming to IS -14846-2000 including material & labour for jointing flanged joint with rubber fibre jointing ring bolt nut & washer etc including necessary earth work. complete all as specified and directed. Make : Kirloskar/Leader/L&T (Audco)/Venus or equivalent from the list of makes.
Material and labour for construction of valve chamber of size 600 x 600 x 600 mm (internal dimensions built in brick masonary on 15 cm thick PCC foundation (1 : 4 : 8) type D-2 using 40 mm graded stone aggregate over 100 mm thick hard cor with brick work masonary in cement mortar 1:4 using 'B' class bricks and rendering in cement mortar 1: 4, 10 mm thick internally including exposed surfaces of external surfaces, MS cover made out of 3 mm thick MS sheet on angle iron framework made out of 40 x 40 x 3 mm duly embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with hold fast made out of MS flat iron 25 x 6 mm x 300 mm long and 40 mm thick PCC coping 40 mm thick 1:2:4 type B-0 using 12.5 mm graded stone aggregate with handle hinges with locking arrangement & applying two coats of synthetic enamel paint over a coat of red oxide primer to all exposed steel surfaces complete all as specified and directed by Engineer-in-Charge.
" EXTERNAL ELECTRIC SUPPLY"
Supply and fix highly efficient high power LED street light fitting 45 watt with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP65 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete all as specified and directed. Make : CG Cat No. LSTP-45-CDL or equivalent of Bajaj /Philips/Wipro
M&L for 7 mtr long hot dipped galvanised octagonal poles with top A/F 70 mm bottom A/F 155 mm made out of 3mm thick HT sheet along with base plate of size 260 x 260 x 16mm including 1500 mm long single arm backet made out of 48 mm dia GI pipe and M20 x 700 m long 'J' type EN8 grade foundation bolts along with template including the following:- (a) MCB SP 6A 230V, 10KV mounted on 3mm thick hylam sheet - 1 No (b) 4 way connector bolt type 2 Nos alongwith locking arrangement weather proof and water proof control space Note: (a) The rate quoted deemed to include the cost 50 mm PVC pipe from cable trench to centre of the pole concrete and 'J' type EN8 grade foundation bolts (b) The rate quoted deemed to include the cost of connecting of incoming and outgoing cable in new octagonal poles through PVC pipe including taking out loop extending upto junction box connecting complete including necessary earth work.
Supply and provide 3 core 2.5sqmm PVC copper cable multi standed drawn through inside octagonal pole from the bottom connector to fitting including providing necessary lugs complete all as specified and directed.
Addition/Alteration of the existing LT panel to accommodate and including MCCB 160 Amps 4 pole, 50Hz 415 Volts, 16 KA complete with bus bar connection with copper conductor of suitable copper cable, lugs etc sheet metal enclosure made out of 2mm thick MH sheet powder coated and matching with the existing panel complete all as specified and directed.
"HOT WATER SUPPLY"
Supply, installing, testing and commissioning of Solar Water Heater of minimum capacity 100 LPD, comprising of the followings : (a) Solar Panel with Evacuated Tube Collector (ETC) made out of Borosilicate glass 2100mm long and 58mm outer dia. (b) Stainless steel tank made out of SS 304L (Low carbon content) with zinc alume outer cladding, horizontal mounting and direct coupling with solar panels including Hi density injected PUF insulation (50mm thickof density as specified in Particular Specifications) with electrical backup (3KW with thermostat) and necessary DTC (Differential Temperature Control) with display comprising of contactors, timer and sensor prewired complete in and including fixed in powder coated MS box and mains from ground floor (G+3) complete with MS powder coated steel supports all as directed: 01 No. Make of Solar Water System: Racold/TATA BP Solar/BHEL/ Maharaja Whiteline/ Usha Note: The rate quoted shall also be deemed to include the cost of erection of the system all as per manufacturer instructions subject to final approval of GE.
S&F 500 Litres capacity Rotational moulded polyethylene 3 layered (ISI marked) water storage tanks (Cylinderical vertical) hoisted and fixed in position including provision of Ball brass valves high pressure with polythene float and flynut complete, 25mm bore, fixed with brass rod and high-density plastic ball, screwed for iron pipe of 25mm bore and also including making connections, provision of all the fittings, fixed in and including 2.5 mtrs height PCC platform complete all as specified and directed. Make : Sintex/ Rotomex/ Polycon or equivalent from the list of makes.
"COOLING APPLIANCES (WATER COOLER AND REFRIGERATOR)"
Supply errect test and commissioning of storage type water cooler with inbuilt UV Purifier of storage capacity 80 ltrs and cooling capacity 60 litres per hour wih comfort level water outlet temp 17°C ± 1°C and storage tank, front, rear and side panels are made out of stainless steel SS304 and 2 Nos of faucets one for cold water and one for normal water with maximum water flow 1.5 lpm including 3 stages of purification (Sedimention/carbon/UV purification) with operating temperature 15°C to 45° C and working with AC, 180-250 Volts supply complete connected with 3 core 1.5 sqmm PVC multistrandard copper conductor flexible cable complete all as specified and directed. Make: Bluestar Model No. SWCSDLX680UVA or equivalent in Voltas/Carrier. Note : The rate quoted deemed to include the cost of water connection from existing water line and 15 mm dia PVC flexible pipe.
Supply and install 5 star rating refrigerators, electric driven (single phase) with gross capacity 253 ltr, gross freezer capacity 69 ltr, gross refrigerant capacity 184 ltrs, frost free, double door with stand complete all as specified and directed. Make : Samsung Model No, RT28M3954U3 or equivalent in Godrej/LG.
Supply, installation and commissioning of metal top deep-freezer, twin door with locking arrangement, high density PUF insulation, energy efficient compressor with the following specifications: (a) Gross capacity : 300 litres (b) Net capacity : 292 litres (c) Temperature range : -180c (d) Power supply : Single phase 230 volts 50Hz of capacity (e) Refrigerant : R-134a (f) PUF insulation : 60 mm Make : Bluestar/Voltas or equivalent.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA
" PILE FOUNDATION WORK"
Erecting pile equipment of any type complete with all accessories centering in position and removing on completion of each pile and MS liner
Boring / drilling into any type of soil for 600 mm, 700 mm & 800 mm dia cast-in-situ piles using RDM (Rotary drilling method) using Betonies, slurry all as required getting out and disposal of soil to a distance outside MD land and disposing at a place all as specified and directed by Engineer-in-charge
Boring / drilling into Soft / disintegrated rock for 600 mm,700 mm,& 800 mm dia cast-in-situ piles using RDM (Rotary drilling method), using Betonies, slurry all as required getting out and disposal of soil to a distance outside MD land and disposing at a place all as specified and directed by Engineer-in-charge
Boring / drilling into Hard rock for 600 mm, 700 mm & 800 mm dia cast-in-situ piles using RDM (Rotary drilling method) using Betonies, slurry all as required getting out and disposal of soil to a distance outside MD land and disposing at a place all as specified and directed by Engineer-in-charge Note for item Nos 18.02 to 18.04 (a) Reinforced controlled cement concrete, reinforcement will be measured and paid separately (b) Spoil mixed with betonite slurry (obtained from boring) shall be deposited outside MD land and depositing at a place as directed by Engineer-in-charge. The unit rate quoted against item Nos 18.02 to 18.04 shall interralia be deemed to include this operation and no extra payment shall be admissible on this account (c) Boring of piles shall be measured and paid from marked average ground level to bottom of pile
M&L for RMC M 30 design mix concrete as per IS 456 of 2000 using 20 mm graded stone aggregate in pile cap and piles of any length / size including cutting and knocking down waste concrete complete all as shown on drawing. Note: RCC will be measured and paid from cut off level and rate quoted shall be inclusive of cutting and knocking of RCC wast above cut off level.
S & F TMT bars 10 mm dia over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & as directed
S & F TMT bars in stirrups 5 to 10 mm dia, cut to length, bent to shape, required, including cranking,/ bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire(annealed) not loss than 0.9mm dia or securing with clips all as specified & as directed
Mild steel liner 6 mm thick for bored-cast-in-situ concrete piles as required including applying 140 micron DFT coal tar epoxy protective coating all as shown on drawing and as specified and directed by Engineer-in-charge.
M & L Testing of pile (Initial Load Test) all as specified and indicated on drawing including bringing at site all testing materials & equipment complete & removing of the same after completion of satisfactory testing for 600, 700 & 800 mm dia pile.
M & L Testing of pile (routine Load test) all as specified and indicated on drawing including bringing at site all testing materials & equipment complete & removing of the same after completion of satisfactory testing for 600, 700 & 800 mm dia pile.
M & L Testing of pile (Integrity Test) all as specified and indicated on drawing incl bringing at site all testing materials & equipment complete & removing of the same after completion of satisfactory testing for 600, 700 & 800 mm dia pile.
rawassa construction
NITYA NAND AND SONS CONTRACTORS PVT LTD
Idustrial products India
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .