Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.7 CrAccepted-AOC NO 95 DEVELOPED ELECTRONICS INDUSTRIAL ESTATE PERUNGUDI CHENNAI 600 096 | CHENNAI | CHENNAI | TAMIL NADU | 600096 | ₹4.7 Cr Quoted ₹4.0 Cr | 1 | Accepted-AOC 1st lowest bidder |
| 2 | 2₹4.4 Cr+₹39.9 L (9.93%)Rejected-Finance | ₹4.4 Cr+₹39.9 L (9.93%) | 2 | Rejected-Finance Highest |
Tender Value
Refer Docs
EMD Value
₹4.9 L
Closing Date
24 Nov 2023, 4:00 pmClosed
DY HE BC
OFFICE OF DY H E BC, ADMIN BUILDING, 2ND FLOOR, KHINDIPADA, MULUND(W) MUMBAi-400082.
Maintenance contract of instrumentation system and Operation and Comprehensive maintenance contract of Flow test laboratory at Bhandup complex for three 03 years 2024 to 2027
2023_MCGM_950368_1
DyHE/BC/23/20/ODN
Open Tender
Electrical and Maintenance Works
Item Rate
1095 days
MUMBAI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹4.9 L
WORLI ENGINEERING HUB MUMBAI
25 Apr 2024
6 Oct 2023
29 Nov 2023
6 Oct 2023
24 Nov 2023
6 Oct 2023
11 Oct 2023
Amount
CMC Of Automation of 9 tunnel & Middle Vaiterna 1st Year
Man power 3 Nos. Engineers 1st Year
Man power 12 Nos Helpers 1st Year
Vehicle charges for 4 Vehicles 1st Year
CMC Smart 8 Nos Actuators Veravali Res 2. 1st year
CMC Of Automation of 9 tunnel & Middle Vaiterna 2nd Year
Man power 3 Nos Engineers 2nd Year
Man power 12 Nos. Helpers 2nd Year
Vehicle charges for 4 Vehicles 2nd Year
CMC Smart Actuators 8 Nos Veravali Res 2. 2nd year
CMC Of Automation of 9 tunnel & Middle Vaiterna 3rd Year
Man power 3 Nos Engineers 3rd Year
Man power 12 Nos. Helpers 3rd Year
Vehicle charges for 4 Vehicles 3rd Year
CMC Smart Actuators 8 Nos Veravali Res 2. 3rd year
O&CM of flow test lab 1st year
Calibration of Master flow meter at Flow test lab
O&CM of flow test lab 2nd year
O&CM of flow test lab 3rd year
Supply and Laying of 3 C X 2.5 mm2 Copper Armored Cable FME 2018 Item No. R2-ME-2-3-f
Supply and laying of Signal cable 2 Pair, 1 mm2 G. I. wire armoured,individual pair screen, overall screened,annealed tinned stranded Cu conductor
Excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 Cu. Mtr. = 2.2 RMT. FME 2018 Item No. R2-ME-2-8
Excavating the trenches and refilling the same after the cable is laid in approved manner (Size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 Cu. Mtr. = 2.2 RMT. And reinstatement. FME 2018 Item No. R2-ME-2-9
Supply & Laying of double wall corrugated ( DWC) pipes of HDPE for underground cable protection as per IS 14930 Part II. ( 90 mm OD / 76 mm I.D.) FME 2018 Item No. R2-ME-2-22-d
Replacement of of terminal housings for multi path ultrasonic flow Meters
NISH TECHNO PROJECTS PVT. LTD
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .