Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹50.5 L+₹1.3 L (2.70%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹50.6 L+₹1.4 L (2.94%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹51.5 L+₹2.3 L (4.76%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹55.3 L+₹6.1 L (12.4%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
7 Mar 2022, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR REPLACEMENT OF EARTHINGS COMPREHENSIVE MAINT TO DG SET INCLUDING REPAIR MAINTENANCE OF DOMESTIC COOLING APPLIANCES WATER COOLERS AND OTHER CERTAIN ALLIED WORKS UNDER GE I GOS
2022_MES_507106_1
8000/95/21-22/0994/E8
Open Tender
Civil Works
Item Rate
270 days
GOPALPUR-ON-SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹98,000
Yes
29 Mar 2022
10 Feb 2022
9 Mar 2022
10 Feb 2022
7 Mar 2022
28 Feb 2022
Amount
Excavation in trenches n.exc 1.5 M wide and n.exc. 1.5 M in depth and getting out in hard/dense soil complete all as specified and directed.
Returning filling in including spreading levelling and well ramming layer n.exc. 25 cm complete all as specified and directed.
Removing the excavated material n.exc. 50m and depositing where directed at level n.exc. 1.5m above the starting point complete all as specified and directed.
Taking up or down CI/GI/PPR of water mains of 150mm bore(including all fittings), with spigot and socket ends lead joints including burning out joints including turning water OFF or ON as necessary taking off and refixing covers, access doors etc complete all as specified and directed.
All as per item No :4 above but 100 mm bore.
Supply , laying, jointing & testing of 150mm bore DI Type K-9 pipe with socket & spigot ends, with cement morter zinc coated out side as per IS 8329/2000 in standard length suitable for and including push on tyton joints with rubber rings, laid in trenches complete all as specified and directed. Make: Jindal/TATA STEEL/SURYA or equivalent of higher cost. (Excavation and earth work, DI specials will be measured and paid seperately)
All as per item No 6 above but 100 mm bore pipe.
M& L for MS/CI/DI fittings up to 150mm bore such as collar, bends (any type radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces (all socketed or all flanged with an equal & other end tapering bellmouth or flanged plates, connecting pieces straight (both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces ( one end flanged & other end spigot or socket or tapering as bell mouth or flanged ) caps blank flanges heavy duty suitable for mechanical joint/flanged joint with and incl taking down old fitting of any type and any size complete all as specified and directed. Note: Certifiacte for Weight of fitting by the manufacturere shall be submitted before payment.
M & L for mechanical type joint made of MS sheet of size 6/8 mm thick along with rubber gasket nuts bolts and washers suitable for 80 mm bore of CI/DI pipe. Including Taking up or down old u/s joint complete all as specified and directed.
All as per item No 09 above but 100 mm bore.
All as per item No 09 above but 150 mm bore.
Provision of out sourcing for Manning & Operation of external services of water supply installation equipments such as operation of Pumps and Motors, DG Set, operation of valves by one operator in each shift duration 0600 hrs to 1400 hrs and 1400 hrs to 2200 hrs for pumping, supply and distribution of water within the proxmity of 1 km, including Sundays & holidays. Cleaning and dusting of all equipments including first hand minor repairs such as fixing of gland, replacement of packings, repair of electric junction connection etc, all as specified and directed for the DG set & pump house at 120 Inf Bn (TA) Bihar Bbsr-I for two shifts daily and having following equipments :- (i) Centrifugal pump set-02 Nos. (ii) DG Set 15 KVA (iii) chloronome plant (iv) Submersible pump set in Bore wells-01 No - 7.5 HP capacity (v) iron removable plant - 01 No.
S&F and testing 150 mm bore CI sluice valves of both ends flanged and drill with brass spindle and brass check nuts, hand wheel made out of CI complete suitable for tested hydrostatic pressure 15 Kg/Sqcm. (PN 1.6) and confirming to IS 780 complete all as specified and directed. Make: Kirloskar/Zoloto/BIR or equivalent of higher cost.
All as per Item 13 above but of size 100 mm bore
All as per Item 13 above but of size 80 mm bore
S&F 150 mm bore cast iron non return valve heavy duty ISI marked with jointing material flanged joint rubber gasket 6 mm thick nuts, MS nuts, bolts, washers including taking out of existing unserviceable one complete all as specified and directed. Make: Kirloskar/Zoloto/BIR or equivalent of higher cost.
S&F 100 mm bore cast iron non return valve heavy duty ISI marked with jointing material flanged joint rubber gasket 6 mm thick nuts, MS nuts, bolts, washers including taking out of existing unserviceable one complete all as specified and directed. Make: Kirloskar/Zoloto/BIR or equivalent of higher cost.
M&L for construction of brick masonary valve pit chamber internal dia (1200x1200x1200mm) including necessary excavation and earth work in any type in CM (1:4), 15 mm thick plaster and PCC 1:4:8 in base complete with valve pit cover GI Sheet 4 mm thickness fitted in 50x50x4 mm equal angle section conforming to Fe 290 Gde E-165 and locking arrangement with lock and key including two coat of synthetic enamel paint complete all as specified and directed.
M & L Cutting wild grassess, bushes, creepers, unwanted vegetations, etc. from inside/ surrounding of installation including cutting creapers from barbed/cattle fencing of the installation as and when directed and removing the spoil and deposit where directed & entire satisfaction of Engr-in-Charge. Note :- (a)The item shall be operated maximum four times in the entire period of the contract in the same installation (Area measured separately each time.) (b) Measurement of cleaning fencing will be measured based on the height between top line and bottom line of barbed wire/chain link/cattle fencing multiplying by the length involved.
S&F of 3 layer PP-R (polypopropylene random co-polymer) pipes SDR 11/PN16 UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain end brass threaded polypopropylene randum fittings laid in trenches 110 mm O/D complete with all connected fittings required incl taking down old unsv complete all as specified and directed. Make : KPT/SFMC/SUPREME or equivalent of higher cost.
S&F of 3 layer PP-R (polypopropylene random co-polymer) pipes SDR 7.4/PN16 UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain end brass threaded polypopropylene randum fittings laid in trenches 63 mm O/D complete with all connected fittings required incl taking down old unsv complete all as specified and directed. Make : KPT/SFMC/SUPREME or equivalent of higher cost.
All as per item No 21 above but 50 mm O/D complete all as specified and directed.
All as per item No 21 above but 32 mm O/D complete all as specified and directed.
S&F in replacement of PP-R gate valve 63 mm OD (brass insert) complete all as specified and directed. Make : SFMC/SUPREME/KPT (ISI mark) or equivalent of higher cost.
All as per item No 24 above but for size 50 mm O/D complete all as specified and directed. Make : SFMC/SUPREME/KPT (ISI mark) or equivalent of higher cost.
All as per item No 24 above for size 32 mm O/D complete all as specified and directed. Make : SFMC/SUPREME/KPT (ISI mark) or equivalent of higher cost.
S&F cast iron sluice valve 100 mm with brass spindles with flanged ends ISI marked PN1.6 type incl taking out old unsv complete all as specified and directed.
M&L cutting of road, pavement, hard standing by skilled labour known better to work with neatly for laying of GI/DI/PPR pipes suitable for working pressure and making good of disturbed surface of cutting road/hard standing/pavement by existing material or PCC as it look before cutting complete all as specified and directed.
M&L for construction of brick masonary valve pit chamber internal dia (900x900x900mm) including necessary excavation and earth work in any type in CM (1:4), 15 mm thick plaster and PCC 1:4:8 in base complete with valve pit cover GI Sheet 4 mm thickness fitted in 50x50x4 mm equal angle section conforming to Fe 290 Gde E-165 and locking arrangement with lock and key including two coat of synthetic enamel painting complete all as specified and directed
Taking down old unsv pump set 10 HP capacity, 3 phase KSD type-1030 with impellar from connected pipe line, dismantling existing motor/pump, rewinding motor by supper enamelled copper wire with existing size, insulation and varnishing complete, replace wornout ball bearing and gland packing of existing pump set and refitting the repaired pump set on pipe line, testing and commissioning complete all as specified and directed.
Taking down old unsv submersible pump set 7.5 KW/HP capacity, 7 stage, 3 phase KSB from bore well, repair/rewinding motor by super enamelled copper wire with existing size, insulation and varnishing complete, replace wornout ball bearing and items as required and refitting complete in all respect, testing and commissioning complete all as specified and directed.
Taking down old unsv booster pump 05 HP capacity, 3 phase from UG sump from existing connected pipe line, dismantling existing motor/pump, rewinding motor by supper enamelled copper wire with existing size, insulation and varnishing complete, replace wornout ball bearing and refitting the repaired booster pump on pipe line, testing and commissioning complete all as specified and directed.
Taking out 80 mm bore sluice valves repairing, refacing, regrinding, replacement of gland packing and refixing back to its original position including repacking of stuffing box of sluice valve spindle complete all as specified and directed.
All as per item No 33 above but 100 mm bore.
All as per item No 33 above but 150 mm bore.
M&L for cutting existing steel tubing/CI/PPR pipe line for alterations or additions for each cut mesaured of sizes 40 mm to 50 mm complete all as specified and directed.
M&L for refixing old tubing any make and size with connections in new or old position on walls, ceiling, floors, trenches etc complete all as specified and directed.
Supply and replacement of media filter of water pressure capacity 6-8 cum including taking out old unsv, servicing of iron removal plant and painting with spray matching with two coat of synthetic enamel paint complete all as specified and directed.
Comprehensive maintenance of DG Set including Alternator AMF Panel for routine check up of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 15 KVA DG Sets installations. (a) Every 200 hours/Six month whichever is earlier (b) Repeat the 'A' Checks (c) Service the oil bath type air cleaner (d) Replace the engine main lub oil filter element & sealing ring (e) Grease the water pump bearing (f) Clean the button filter (g) Replace the Air filter (h) Replace the filter element (Oil filter, fuel filter etc) complete. (j) Replace the lubricant oil (IC engine for Gen set application). Old oil should be drained out after warming the engine. (Use MIL-L 2104C mono-grade oils only/15W40 overlain cummins/equivalent) (k) Replace the engine and turbocharger lubricant oil filter element (l) Check oil level in the fuel pump and top up if required (m) Drain radiator after warming the engine, change the water (n) Knock out soot from the exhaust silencer (o) Check and tighten all fasteners to the specified torque (p) Check the tighten all hose connection check and tighten all lubricant and fuel connection.
Servicing of radiator assembly complete for cleaning after draining out cooling water/coolant, spaces cleaning the inter coller and replace unserviceable rubber hose pipes, circlip clamps, cleaning of raditor mix with appropriate cleaning agent, de-scaling by means of scale solvent as well as neutralising agent to arrest leakages by means of brazing etc including replacement of coolant for the capacity of DG Set 15 KVA complete all as specified and directed.
Supply and replacement of lead acid battery 75 Amp, 12 Volt, complete all as specified and directed. Make : EXIDE/AMCO or equivalent of higher cost.
Repair and servicing of 15 KVA Engine Kirlosker type RB 66/Cummins turbocharger assembly and replacing the service kit and reassembling testing complete all as specified and directed.
Servicing of self starter assembly of DG Set 24/12 Volts of 15 KVA capacity by disconnecting the self starter assembly from the engine and dismantling cleaning all accessories, replacing worn out parts like carbon brushes contact plates jumping levels etc and rewinding the fields coil and warnishing complete all as specified and directed.
Supply and replacement of Automatic voltage regulator (AVR) suitable for DG Set 15 KVA, complete all as specified and directed.
Supply, jointing, fixing or passing through pipe, trenches or ducts,commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 70 Sqmm 3.5 core for working voltage upto including 1100 volts confirming to IS - 7098 (Part-I) 1988, including taking down existing cable, complete all as specified and directed.
Supply only down rod of ceiling fan with medium grade of 15 mm size pipe complete with drilling holes, cutting and making threads as per site requirement up to 0.50 to 1 mtr, painting with two coats of synthetic enamel paint as existing complete all as specified and directed.
S&F Ceiling Fan regulator electronic step type as per sample complete all as specified and directed. Make : Indo Asian/Plaza/Havells/Anchor
S&F single pole and neutral enclosure with a two pin and earth plug socket 240 V with one MCB SP ‘C’ series rating 20 to 32 Amp incl taking down the old unsv complete all as specified and directed. Make : Polycab /C&S/Havells.
M&L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 Metres below normal ground level, connecting to the Galvanised iron earth lead wire 4mm dia, by means of bolts, nuts, check nuts and washers of galvanised iron and 4mm earth lead protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 75x50x6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR-2009 Part-I and connecting to earth test point including testing on complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanised iron strip 32mm X 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of GI and GI strip protected by provision of GI pipe light grade, 40mm bore upto test point including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metres long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron strip 32mm X 6mm size and protection pipe of 40 mm bore galvanised iron light grade.
S&F Test point block made of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed incl 3 nos of 8 mm dia 25mm long hex.head screws complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light, fan/exhaust fan, bell, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders, brackets, bell, bulk head fittings etc removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and also making good disturbed surfaces of wall, floors etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating FRLS electric cable 1100 volts cable and including PVC casing and caping of suitable size (as per conductor run) with all fittings/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly by providing lugs including sunk in pressed steel terminal boxes of 1.6 mm thick concealed in wall (duly painted with two coats of black bituminous paint over a coat of red oxide primer in and out sides) with and including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc and making good disturbed surfaces of wall and matching colour as per existing for one light point controlled by one, one way switch complete all as specified and directed. Make of wire : Plaza/Polycab/Havells.
All as per item No 60 above but for one fan/exhaust fan/bell point point controlled by one, one way switch
All as per item No 60 above but for one 5 Amp socket point controlled by one way switch on independent board.
All as per item No 60 above but for one 5 Amp Socket point controlled by one way switch on the same board with other switches.
All as per serial item No 60 above , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and directed. Make of wire : Plaza/Polycab/Havells.
M&L for socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed. Make : Indo Asian/ Plaza/ Havells/Anchor
M&L for socket outlet 2 in 1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and directed. Make : Indo Asian/ Plaza/Havells/Anchor
M&L for Switch piano flush button 5 Amps complete all as specified and directed. Make : Indo Asian/Plaza/Havells/Anchor
M&L for Switch piano flush type single pole one way 15 Amp complete all as specified and directed. Make : Indo Asian/Plaza/ Havells/Anchor
M&L for ceiling rose surface type, 65 mm x 50 mm two to three terminals/PVC/polycarbonate, isolated body fixed on PVC block complete all as specified and directed. Make : Indo Asian/Plaza/Havells/Anchor
S&F Ceiling Fan regulator electronic step type as per sample complete all as specified and directed. Make : Indo Asian/Plaza/Havells/Anchor
M&L for wooden rectangular block of size suitable for DB 8 way/DB 4 way TPN, closed recessed 3mm thick plastic laminated sheet complete all as specified and directed.
S&F PVC insulated copper wire 1.5 Sqmm, single core including taking out old unsv wire complete all as specified and directed. Make : Havells or equivalent in Polycab/Plaza.
S&F PVC insulated copper wire 2.5 Sqmm, single core including taking out old unsv wire complete all as specified and directed. Make : Havells or equivalent in Polycab/Plaza.
S&F LED light fitting 1 x 40 Watt LED Al batten complete with new generation LED T8 batten for multipurpose application made from extruded aluminium housing and polycarbonate diffuser complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size incl taking down the old USNV complete all as specified and directed. Make : Surya SLE BTN T8 40W Havells/Philips.
S&F LED light fitting 1 x 10 Watt T5 Al batten type, indoor decorative PC housing extruded T5 Al LED battens with extruded aluminium housing and integrated LED driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size incl taking down the old USNV complete all as specified and directed Make : Surya Cat No SLE BT 10 or equivalent in Havells/Philips.
S&F LED lamp 9 Watt complete all as specified and directed. Make : C&S Cat No LTHPLEDLAMP9WB22 or equivalent in Surya/Havells.
S&F new generation energy saving LED Bulk Head Plus fitting in engineering plastic housing with clear prismatic diffuser complete all as specified and directed. Make : Surya Part No SLE BLH 10W PLUS or equivalent in Havells/Philips.
M&L for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 15/18 watts for batten fitting, including plastic square board of required size complete all as specified and directed. Make : Indo Asian/Plaza/Havells/Anchor.
S&F recess/ceiling down lights 36 watt LED (600x600mm) size, ultra slim with extruded alumininium housing and milky diffuser complete including taking down old unsv complete all as specified and directed. Make : C&S Cat No LTCRSLM36WATT2x2 or equivalent in Surya/Havells.
Taking down and re-fixing, connecting existing electric meters, single/three phase complete all as specified and directed.
S&F switch socket combination multipurpose 2 in 1 3 pin, 5 Amp flush type complete. Make : Havells/Plaza/SSK/Polycab
S&F switch socket combination 2-in-1, 3/5 pin 5 and 15 Amp incl taking down the old USNV complete all as specified and directed. Make : Havells/Plaza/SSK/Polycab
S & F bell push piano (Flush type) 5 Amp 240 Volts incl taking down the old unsv complete all as specified and directed. Make : Anchor/Cona/Havells.
S & F bell/buzzer electric single phase 240 volt incl taking down the old unsv complete all as specified and directed. Make : Anchor/Cona/Havells.
S & F PVC conduit pipe 20 mm dia complete alongwith necessary fixing arrangement incl taking down the old USNV complete all as specified and directed.
S & F PVC casing capping 25mm complete alongwith necessary fixing arrangement incl taking down the old USNV complete all as specified and directed.
S & F MCB TPN 63 Amp 415 Volts incl taking down the old USNV complete all as specified and directed. Make : Polycab/Havells/ C&S.
S & F MCB TPN 40 Amp 415 Volts incl taking down the old USNV complete all as specified and directed. Make : Polycab/ Havells/C&S.
S&F Isolator DP 32A, 240 volts complete all as specified and directed. Make : Polycab/C&S
S&F MCB SP 10 to 32 Amp, 240 volt complete all as specified and directed. Make : C&S/Polycab/Havells.
S&F sheet metal enclosure for DB’s suitable for MCBs of single pole and neutral 8 way complete all as specified and directed. (Double door) with 200 amp rated bus bar. Make : C&S/Polycab/Havells.
S&F for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi-strand copper conductor including in PVC casing caping with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed. (Three runs of wire will be measured as single run)
S&F for sub main wiring two single core PVC insulated and unsheathed cable with 4 Sqmm multi-strand copper conductor including in PVC casing caping with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed. (Three runs of wire will be measured as single run).
M&L for complete removal of existing painting by scrapping the old surface, preparation of fan surface and applying spray painting with spray nozzle to ceilling fan of any make and any size with two coat of synthetic enamel paint as existing colour/shade over a coat of red oxide primer complete all as specified and directed.
Taking down ceiling fan & Exhaust fan of any make and any size for repair/replacement of defective spare parts and overhauling the fans by cleaning, greasing and replacement of old split pin, rubber reel, connected items and provide flexible wire of size 23/0.0076 for connection from ceiling rose to fan/exhaust fan, refixing the same and testing complete all as specified and directed. Note:- Rewinding, painting and supply of new components will be measured and paid separately under relevant items complete all as specified and directed.
M&L for rewinding the ceiling fan any make 1200/1400mm sweep and any size with super quality copper conductor adequate winding wire of existing size complete all as specified and directed.
M&L for rewinding the exhaust fan any make 300/450mm sweep any size with super quality copper conductor adequate size of winding wire of existing size, refixing the ball bearing, greasing complete all as specified and directed .
Supply only ball bearing of suitable size for ceilling fans any make, type and size complete all as specified and directed. Make : SKF /TATA /NBC
Supply only capacitor of 4 MFD, 240 Volt suitable for ceilling/exhaust fan complete all as specified and directed. Make :- Universal /Usha/ Electro
Supply only capacitor of 2.5 MFD, 240 Volt suitable for ceilling/ exhaust fan complete all as specified and directed. Make : Universal/ Usha/Electro
Supply only down rod of ceiling fan with medium grade of 15 mm size pipe complete with drilling holes, cutting and making threads as per site requirement up to 0.50 to 1 mtr, painting with two coats of synthetic enamel paint as existing complete all as specified and directed.
S&F PVC flexible pipe of size 15mm or 20 mm complete all as per site reqmt for protectin of wire complete all as specified and directed.
S&F Plastic enclosure without MCB SP & DP as required in site with fixing on wall/pole etc with binding/fixing material complete all as specified and directed. Make : C&S/Havells/Indo Asian.
S&F PVC insulated copper wire 1.5 Sqmm, three core including taking out old unsv wire complete all as specified and directed. Make : Havells or equivalent in Polycab/Plaza.
supply and replacement bolts, nuts and washers, rubber reel, capacitor clamp, split pin of appropriate size as required at site for ceiling fan of any size complete all as specified and directed.
S&F street light fitting LED type 15 Watt new generation energy saving powder coated pressure die cast aluminum high powder with heat resistant toughened glass with lens & IP65 with high power LEDs as light source and electronic driver with GI tubing 25/40 mm dia, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with 2 run of flexible copper conductor of size 1.5 sq mm cable from fitting to junction box, testing & commissioning complete all as specified and directed. Make : C&S Cat Part No LTESSI5WLED or equivalent in Surya/Havells.
S&F decorative LED post top lantern luminaire with milky diffuser and painted aluminium deflector complete with connecting of suitable size of wire incl taking down old unsv complete all as specified and directed. Make C&S Cat part No LTGLC20WHPLED/W or equivalent in Surya/Havells.
S&F 9W decorative LED extruded aluminium bollard light with integrate driver complete with connecting of suitable size of wire incl taking down old unsv complete all as specified and directed. Make: C&S Cat part No LTGLC9WLED or equivalent in Surya/Havells.
S&F SMD LED flood light 90 watt with prressure die cast aluminium housing complete with all accessories with connecting of suitable size of wire with suitable size of calmp, nut and bolts incl taking down old unsv complete all as specified and directed. Make: C&S Cat part No LTEF90WHPLED or equivalent in Surya/Havells.
S&F street light fitting LED type 45 Watt new generation energy saving powder coated pressure die cast aluminum high powder with heat resistant toughened glass with lens & IP65 with high power LEDs as light source and electronic driver with GI tubing 40mm dia, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with 2 run of flexible copper conductor of size 1.5 sq mm cable from fitting to junction box, testing & commissioning complete all as specified and directed. Make : C&S Cat Part No LTESSI45WLED or equivalent in Surya/Havells.
Supply and replacement RYB Indicating lamp for phases complete all as specified and directed.
Supply and replacement 30/32 Amp TPN plug and socket (metal clad) complete all as specified and directed.
Maint and servicing of window type/split type air conditioner including cleaning filter, washing with soap solution after removing from site and refixing the same complete all as specified and directed.
Supply and replacement of unserviceable compressor (sealed unit) from window type/split type air conditioner of capacity 1.5/2 Ton on position with nuts, bolts, rubber gromote and washers, flare nuts including taking out old unsv compressor of approved make.
Supply and replacement running capacitor 36/50/80 MFD suitable for 1.5/2 Ton window type and split type air conditioner including taking down old unsv complete all as specified and directed. Make : SARADA/KEIL/KELTRON/ORICAP
Supply and replacement starting relay assembly including coat & cover and clips suitable for window/split typeair conditioner complete all as specified and directed. Make : TECHNOMECH/KELTRON
Supply and replacement of blower motor suitable for 1.5/2 Ton window/split type air conditioner AC single phase 230 Volts including bushes, testing and commissioning complete all as specified and directed.
Supply and replacement of air filter Pad suitable for air conditioner 1.5 Ton capacity complete all as specified and directed.
Carrying out pressure leak test by nitrogen pressure for detecting leak in condensing unit, refrigerant pipe and repairing the leakage by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak, checking after repairs of leak pipe including transporting and carrying out T&P required at site for work of 1.5/2 Ton capacity air conditioner complete all as specified and directed.
Flushing out by N2 and CTC, vaccumnation, supply and charging of refrigerant gas into the system for 1.5 Ton capacity air conditioner complete all as specified and directed.
Dismantling of defective cooling indoor/outdoor unit of 1.5 Ton capacity of split type air conditioner complete with connected piping and corded remote control etc and refixing on wall/floor after carrying out repairs and servicing and making good the disturbed surfaces complete all as specified and directed.
Supply and replacement of condensing unit of 1.5 Ton capacity complete with connected lead and iron stand etc including taking down old defective complete all as specified and directed.
Supply and replacement of cooling coil assembly suitable for air conditioner 1.5 Ton capacity complete all as specified and directed.
Supply and replacement suction copper pipe line heavy ½” dia with foam insulation and flair nuts from indoor to out door unit of split type air conditioner 1.5 Ton capacity complete all as specified and directed.
Supply and replacement suction copper pipe line heavy 3/8” dia with foam insulation and flair nuts from indoor to out door unit of split type air conditioner 1.5 Ton capacity complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug socket 240 volt with one MCB DP ‘C’ series rating 20 to 32 Amp incl taking down the old USNV complete all as specified and directed. Make: C&S/Polycab/Havells.
Supply and replacement heating unit (element) ISI marked of 1500 watts triangular/circuler shape or as per sample required in existing geysers installed at site including rubber washers complete all as specified and directed. Make : Umpire/Wondercool/Ditz/ Toshiba
Supply and replacement thermostat range 0°-75°C for the geysers of 25 to 35 litres as per sample required in existing geysers installed at site complete, all as specified and directed.
Supply and replacement PVC threaded tough rubber flexible pipe/tubing of 15 mm size with PTMT nuts at both end 300/450 mm long for geysers inlet/ outlet connections, complete all as specified and directed.
Supply and replacement LED Indicator lamp rectangular/round type as required at site complete all as specified and directed.
Supply and replacement of starting relay assembly suitable for refrigerator 165-200 ltrs capacity as per sample complete all as specified and directed.
Supply and replacement thermostat switch for refrigerator 165-200 ltrs capacity complete all as specified and directed.
Supply and replacement cabin bulb 5 watt 230 Volts screw/pin type for refrigerators complete all as specified and directed.
Supply and replacement door gasket magnetic type suitable for refrigerator 165-200 ltrs capacity as per sample complete all as specified and directed.
Supply and replacement condenser coil suitable for refrigerator 165-200 ltrs capacity complete all as specified and directed.
Supply and replacement of compressor for 165-200 litre capacity refrigerator including taking out old unsv and fixing on position with nuts, bolts, rubber gromote and washers, connecting copper tubing by welding/flare nuts, complete all as specified and directed.
Carrying out pressure leak test by nitrogen pressure for detecting leakage in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairing of leak pipe including transporting & carrying out T&P required at site complete all as specified and directed for refrigerators 165-200 ltrs.
Flushing out by N2 and CTC, vaccumnation and supply and charging of refrigerant gas into the system of refrigerant for refrigerators 165-200 ltrs complete all as specified and directed.
S & F (in replacement) cooling coil for refrigerators 165-200 litre capacity after disconnecting the cooling coil from refrigerator, testing and flushing out the system and charging with refrigerant gas as per required quantity and testing complete all as specified and directed.
S&F in replacement candle like Carbon, membrance, sediment, alkaline, UV lamp and UV barrel for water fiiter any make/size as per sample complete all as specified and directed.
S&F in replacement SV Valve for water fiiter any make/size as per sample complete all as specified and directed.
S&F in replacement relay for water fiiter any make/size as per sample complete all as specified and directed.
S&F in replacement motor for water fiiter any make/size as per sample complete all as specified and directed.
S&F in replacement adopter for water fiiter any make/size as per sample complete all as specified and directed.
Dismantling of water cooler of 40-80 ltrs storage capacity from its position, taking out water from its water tank cleaning of water tank by washing powder and with fresh water externally and internally and storage tank without disturbing the existing position and connecting the water line including GI fitting when required and PVC pipe connection complete all as specified and directed.
Taking out defective gasket of storage water cooler top cover and supply & fixing new rubber gasket of existing size complete all as specified and directed.
S & F (in replacement) condensing coil suitable for 40-80 ltrs capacity water cooler of any make complete all as specified and directed.
Supply and replacement starting capacitor 60/80 Mfd including taking out old unsv complete all as specified and directed. Make : SARADA/KELTRON/ORICAP
S&F (in replacement) capacitor 4 Mfd suitable for blower motor of water cooler complete all as specified and directed. Make : SARADA/KELTRON/ORICAP
S&F (in replacement) thermostat suitable for water cooler any capacity complete all as specified and directed. (Make : ROCKWELL/INDFOSS)
S&F (in replacement) push/lift type self closing taps suitable for water cooler complete all as specified and directed.
S&F (in replacement) PVC float valve assembly with ball suitable for 15 mm bore pipe of water cooler complete all as specified and directed.
Supply and replacement of compressor including disconnecting suction/ discharge copper tubing of water cooler including taking out old unsv and fixing on position with nuts, bolts, rubber gromote and washers, connecting copper tubing by welding/flame nuts, detecting leak and repairs if any, complete all as specified and directed.
Carrying out pressure leak test by nitrogen pressure for detecting leak in condensing unit, refrigerant pipe and repairing the leakage by welding or brazing of condensing unit refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including transporting & carrying out T&P required at site for work of water cooler complete all as specified and directed.
Flushing out by Nitrogen and CTC, vacuum and supply charging of refrigerant gas as existing into the system for water cooler complete all as specified and directed.
Dismantling of unserviceable legs of water cooler and supply & fixing new legs of water cooler made out of 16 gauge MS sheet including welding/riveting and reinstalling the same after repairs / replacement complete all as specified and directed.
Removing defective condensing fan motor of water cooler single phase 230 V 50 HZ and opening and replacing of Blower motor and cutting out the burnt wiring and cleaning the slots of rotor and rewinding of the same with the existing size of super enamelled copper winding wire including insulation, varnishing, greasing, replacement of bushes, reassembling including testing and commissioning complete all as specified and directed.
S&F water pump for desert cooler any make and size as per sample complete all as specified and directed.
S&F cooling pad (benature/PVC ), (set of 3) for desert cooler any make and size as per sample complete all as specified and directed.
S&F capacitor 3.5 mfd complete all as specified and directed.
S&F float valve for desert cooler any make and size as per sample complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 8 cm below cable and 15 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.
Supply and laying Fly ash bricks in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, with aluminium conductor 1100 V grade laid in trenches/ along poles, ducts or through sleeve including taking out existing unserviceable cable of the following sizes complete all as specified and directed Make: Polycab/Havells/Gloster. Note : Earth work, sand cushioning and bricks will be measured and paid separately under relevant items. (a) 25 Sqmm 3.5 core.
(b) 10 Sqmm 2 core
S&F for GI tubing light grade with all fittings laid in trenches or under road crossing or fixed along walls/poles as protection pipe with clamps, nut, washer bolts (where necessary) bore of pipe 40mm including taking down existing pipe complete all as specified and directed.
S&F Thermal Magnetic release, MCCB 250 Amps 415 Volts, 4 pole 35 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete all as specified and directed. Make C&S Cat No CSE2N250ATM4P-* or equivalent in HPL/Indo Asian.
S&F Thermal Magnetic release, MCCB 125 Amps 415 Volts, 4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10 In complete all as specified and directed. Make C&S Cat No CSE1M125ATM4P-* or equivalent in HPL/Indo Asian.
S&F pole box of new technology made up of Thermoplastic Polycarbonate Pole box, install, testing and commissioning of Thermoplastic Polycarbonate Pole box which is shock, rust, dust, impact and water proof, halogen and silicon free, UV resistance with internally embedded gasket high grade gasket made of polyurethane. The thermoplastic pole box suitable size with degree of protection IP 65, type tested, system voltage – 230V , 50Hz, Capacity with temperature resistance of -40°C to 120°C, with cable entry ,suitable size of Glands, all as specified and duly mounted on steel tubluar pole with suitable MS flat with bolts nuts and washers complete including supply fixing and making provision of the following :- (a) MCB SPN 30/32 Amp.
M&L for Painting to existing steel tubular LT poles , 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminium paint superior quality of approved make on surface expose to view and making 30 cm wide strips (total 5 Nos) with white and black paint alternatively on external surface above PCC benching including prepration of old painted surface by scraping complete all as specified and directed.
S&F of 3 layer PP-R (polypopropylene random co-polymer) pipes SDR 7.4/PN16 UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain end brass threaded polypopropylene randum fittings laid in trenches 40 mm O/D complete with all connected fittings incl taking down old unsv complete all as specified and directed (ISI marked) Make : KPT/SFMC/SUPREME.
S&F of 3 layer PP-R (polypopropylene random co-polymer) pipes SDR 7.4/PN16 UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain end brass threaded polypopropylene randum fittings laid in trenches 25 mm O/D complete with all connected fittings incl taking down old unsv complete all as specified and directed (ISI marked) Make : KPT/SFMC/SUPREME
S&F in replacement of PP-R gate valve 25 mm (brass insert) O/D complete all as specified and directed. Make : SFMC/SUPREME/KPT (ISI mark)
S&F foot valve 50/63 mm dia CI/GI with complete fittings including taking out old unsv complete all as specified and directed.
Taking down unsv pump set 5 HP capacity from connected pipe line, dismantling existing motor/pump, rewinding motor by supper enamelled copper wire with existing size, insulation and varnishing complete, replace wornout ball bearing and gland packing of existing pump set and refitting the repaired pump set on pipe line, testing and commissioning complete all as specified and directed.
Taking down unsv booster pump 05 HP capacity, 3 phase from UG sump from existing connected pipe line, dismantling existing motor/pump, rewinding motor by supper enamelled copper wire with existing size, insulation and varnishing complete, replace wornout ball bearing and refitting the repaired booster pump on pipe line, testing and commissioning complete all as specified and directed.
Comprehensive maintenance of DG Set including Alternator AMF Panel for routine check up of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions complete all as specified and directed by the Engineer-in-Charge for 40 KVA DG Sets installations: (A) Every 50 Hours/One month whichever is earlier (a) Repeat the daily checks (b) Check oil level in the oil bath type air cleaner (c) Check the fan belt tension. The deflection should be within 8 to 10 mm at the Centre (for details pleaser refer to the maintenance manual) (d) Check the electrical connection
Comprehensive maintenance of DG Set including Alternator AMF Panel for routine check up of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions complete all as specified and directed by the Engineer-in-Charge for 40 KVA DG Sets installatons: (a) Every 200 hours/Six month whichever is earlier (b) Repeat the 'A' Checks (c) Service the oil bath type air cleaner (d) Replace the engine main lub oil filter element & sealing ring (e) Grease the water pump bearing (f) Clean the button filter (g) Replace the Air filter (h) Replace the filter element (Oil filter, fuel filter etc) complete. (j) Replace the lubricant oil (IC engine for Gen set application). Old oil should be drained out after warming the engine. (Use MIL-L 2104C mono-grade oils only/15W40 overlain cummins/equivalent) (k) Replace the engine and turbocharger lubricant oil filter element (l) Check oil level in the fuel pump and top up if required (m) Drain radiator after warming the engine, change the water (n) Knock out soot from the exhaust silencer (o) Check and tighten all fasteners to the specified torque (p) Check the tighten all hose connection check and tighten all lubricant and fuel connection.
Servicing of radiator assembly complete for cleaning after draining out cooling water/coolant, spaces cleaning the inter coller and replace unserviceable rubber hose pipes, circlip clamps, cleaning of radiator mix with appropriate cleaning agent, de-scaling by means of scale solvent as well as neutralising agent to arrest leakages by means of brazing etc including replacement of coolant for the capacity of DG Set 40 KVA complete all as specified and directed.
Repair and servicing of 40 KVA Engine Kirlosker type RB 66/Cummins turbocharger assembly and replacing the service kit and reassembling testing complete all as specified and directed.
Servicing of self starter assembly of DG Set 24/12 Volts of 40 KVA capacity by disconnecting the self starter assembly from the engine and dismantling cleaning all accessories, replacing worn out parts like carbon brushes contact plates jumping levels etc and rewinding the fields coil and warnishing complete all as specified and directed.
Opening the coupling and dismantling the alternator carefully by removing the flywheel and unservicable starting gear wheel, supply and fixing new starting gear for 40 KVA DG set, complete all as specified and directed.
Supply and replacement thermostat switch suitable for air conditioner 1.5 Ton capacity any make complete all as specified and directed.
Supply and replacement safety valve/high pressure valve 15 mm complete, all as specified and directed.
S & F LED light fitting 1 x 18 Watt LED Al batten complete with new generation LED T8 batten for multipurpose application made from extruded aluminium housing and polycarbonate diffuser complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size incl taking down the old USNV complete all as specified and directed. Make : Surya/Havells/Philips.
JAGANNATH REFRIGERATION INDUSTRIES
M/s MAA BHAIRABI ENTERPRISES
chauhan syndicate
HARAGOURI SUPPLIERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .