Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹7.9 L+₹2,067 (0.26%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹7.9 L+₹2,858.50 (0.36%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹8.4 L+₹53,267 (6.78%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical category not eligiable |
Tender Value
₹8.4 L
EMD Value
₹16,800
Closing Date
10 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AIR FORCE STATION AMRITSAR
ASST. GARRISON ENGINEER (I) AIR FORCE STATION AMRITSAR - 143001
REPAIR / REPLACEMENT OF LT DISTRIBUTION NETWORK AND ASSOCIATED WORKS AT AIR FORCE STATION AMRITSAR UNDER AGE (I) AF AMRITSAR
2022_MES_571318_1
AGE (I) AF/ASR/T-17/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) AIR FORCE STATION AMRITSAR
Class E and category b (i)
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AIR FORCE STATION AMRITSAR
₹16,800
Yes
16 Feb 2023
26 Dec 2022
12 Jan 2023
26 Dec 2022
10 Jan 2023
28 Dec 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cables and foundation of poles etc by mechanically and getting out complete all as spceified and directed by Engr-in-charge.
Returning, filling in trenches (soil) including spreading leveling and well ramming in layers not exc 25 cm thick complete all as spceified and directed by Engr-in-charge.
Removal of surplus excavation soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as spceified and directed by Engr-in-charge.
M&L sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts. complete all as spceified and directed by Engr-in-charge. Note: Punned down thickness (overall 18cm), shall be considered for measurement and payment.
M&L, locally available , sub class 'B' bricks (old size) laid flat and dry in trenches over the cable for protectionprependicular to the direction of cable adjacent to each other complete all as spceified and directed by Engr-in-charge.
M&L, GI pipe light grade 80 mm dia bore for cable protection fixed to pole or under road/ pavement, complete including MS clamps, nuts, bolts etc complete all as spceified and directed by Engr-in-charge.
M&L, GI pipe light grade 40mm dia bore for cable protection fixed to pole or under road/ pavement, complete including MS clamps, nuts, bolts etccomplete all as spceified and directed by Engr-in-charge.
Supply, Laying, jointing and commissioning, LT under gound cables XLPE insulated screened PVC bedded galvanized steel strip armoured electric powder cable (heavy duty) with alumininum conductor cross sectional are 120 Sqmm 3.5 core LT, 1100 volts grade , laid in trenches , along poles or passing with through pipe or laid under floor or through/ on walls etc, complete all as spceified and directed by Engr-in-charge.
Supply, Laying, jointing and commissioning, LT under gound cables XLPE insulated screened PVC bedded galvanized steel strip armoured electric powder cable (heavy duty) with alumininum conductor cross sectional are 95 Sqmm 3.5 core LT, 1100 volts grade , laid in trenches , along poles or passing with through pipe or laid under floor or through/ on walls etc, complete all as spceified and directed by Engr-in-charge.
Supply, Laying, jointing and commissioning, LT under gound cables XLPE insulated screened PVC bedded galvanized steel strip armoured electric powder cable (heavy duty) with alumininum conductor cross sectional are 16 Sqmm 4 core LT, 1100 volts grade , laid in trenches , along poles or passing with through pipe or laid under floor or through/ on walls etc, complete all as spceified and directed by Engr-in-charge.
Supply, Laying, jointing and commissioning, LT under gound cables XLPE insulated screened PVC bedded galvanized steel strip armoured electric powder cable (heavy duty) with alumininum conductor cross sectional are 50 Sqmm 3.5 core LT, 1100 volts grade , laid in trenches , along poles or passing with through pipe or laid under floor or through/ on walls etc, complete all as spceified and directed by Engr-in-charge.
Supply, install, test and commissioning in replacement of factory made tested (Including CPRI type tested certificate ) LT panel board cubical outdoor type of size 0.75 x 0.75 x 0.40 mtrs, plate mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminium bus bar of rating 400 Amp installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 40X40X6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 4.0 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size etc all as deviated with the following fitments:- (a) MCCB 4 pole 415 volt 250 amp rating bracking capacity 36 KA incoming (Adjustable Overload 40-100%). (b) Bus bar: Providing suitable size of Bus bar of aluminium 400 amp rating with coloured heat shrinkable insuated sleeves 415 volts as per IS of suitable size mounted on DMC/epoxy insulator
Supply and fixing Three phase Voltmeter Digital type class 0.5 incl of Make HPL or equivalent to Havells,Bajaj . complete all as spceified and directed by Engr-in-charge.
Supply and fixing Three phase Ammeter Digital type class 0.5 of Make HPL to Havells,Bajaj complete all as spceified and directed by Engr-in-charge.
Supply & Fixing MCCB 630 Amp Four pole 415 volts Breaking Capacity 50 KA with Adjustable thermal & fixed magnetic setting as per existing fixed on site, complete all as spceified and directed by Engr-in-charge.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (1991)incl dismanteling of existing unserviceable erth pit, the desired value of resistance should be less than 3 Ohm. Providing a suitable size of Placard at each Earthing as per sample complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron strip 25X4mm as earth lead by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (1991)dismanteling of existingunserviceable erth pit, the desired value of resistance should be less than 3 Ohm. Providing a suitable size of Placard at each Earthing as per sample complete all as specified and directed by Engr-in-Charge.
Material and labour for GI strip 25mm x 4mm fixing with porcelain insulators on roof and floor, complete all as spceified and directed by Engr-in-charge.
Supply and fixing pre-casted RCC earth pit cover for replacing broken/ unserviceable pit cover including cleaning the surronding area (60 x60 cm), complete all as spceified and directed by Engr-in-charge.
Supply and fixing funnel alongwith wire mesh in replacement of missing/ unserviceable item, complete all as spceified and directed by Engr-in-charge.
Supply & fixing porcelain supporting insulator of existing size / adequate size fixing on wall / roof for insulating and supporting the lightning strips to protect during lightning, complete all as spceified and directed by Engr-in-charge.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as as specified and directed by Engr In charge.
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as as specified and directed by Engr In charge
Demolition of cement concrete ( unreinforced) of any description and in any position not otherwise specially provided for including removal of debries out of defence land complete all as specified and directed
Material and labour for 100 mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in sub base of floors, complete all as specified and directed.
Material and labour for 75 mm thick plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in floors, finished the surface even and fair, complete all as specified and directed.
Material and labour for providing chemical earthing of advance system of Copper pipe Chemrode 3 mtrs long 50mm dia and inner strip of copper as earthing electrodesand filled with conducting concrete back fill compounds with the permanent sealings at both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connecting the strip/wire to the load. To ensure the moisture content and electrical conductivity, each earthing pit shall be provided with minimum 03 bags of 25 kgs chemical compound. An arrangement for connection of copper cable suitable size from rod to be made with given Terminal point with SS Nut Bolts, provision of polymer chamber with cover, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil, the desired value of resistance should be less than 1 Ohm, Entire work will be executed by OEM, complete all as specified and as directed.
Repair to Solar Street lights of any type and size including thorough checking of electric connections, batteries, panels etc and replacement of old defective cables & lugs , charging of existing battiries, connecting accessories and making the light completely functional (replacement of following items, if required for making the light functional shall be measured and paid for under respective item here-in-after) completeall as directed.
S&F Battery 12 volt, 60 AH , Make – Exide/ Su-kam/Amco/Luminous/Instapower complete all as directed.
S&F Container of housing battery make as approved the Engineer-in-charge complete all as directed.
S&F LED solar light fitting 12 watt including auto cut mechanism of approved make complete all as directed.
S&F Solar panel suitable for 60 watt complete all as directed.
Preperation of solar light poles with two coats of synthetic enamal paint of approved shade over a coat of red oxide primer after necessary all as specified and directed by Engr-in-Charge
Supply and fixing Gong bell 4" single phase 220/250Volt AC and /or DC, complete all as spceified and directed by Engr-in-charge.
Supply and fix timer switches 415 V three Phase of 6KW digital 24 Hrs type with contactor fitted inside steel enclosure complete with all connecting accessories all as specified and directed by Engineer in charge. Cat Part No: HXTS03060 of Havells or equivalent.
Bracket made out of GI pipe light grade 25 mm dia 1.50 mtr long duly welded with MS pipe capacity of 100mm dia ,30 cm long with holes ,nuts ,bolts and fixing on the top of pole complete all as specified.
Bracket made out of GI pipe light grade 40 mm dia 1.50 mtr long duly welded with MS pipe capacity of 100mm dia ,30 cm long with holes ,nuts ,bolts and fixing on the top of pole complete all as specified.
Note: The Total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit.
kapoor and co
pee kay construction
M/S SIMRAN WALIA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .