8165 SPECIAL REPAIRS TO ORs MD ACCN BLDG NO 55 15 16 17 AND 18 AT ZOZILA LINE AT ASI AND SPECIAL REPAIRS TO TOILET OF BLDG NO P 87 AT AIPT UNDER GE CENTRAL PUNE
2020_MES_343395_1
8165 SPECIAL REPAIRS TO ORs MD ACCN BLDG NO 55/15
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (Central) Pune
As per tender
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹57,800
Yes
6 Aug 2020
8 May 2020
24 Jun 2020
8 May 2020
22 Jun 2020
1 Jun 2020
Amount
Demolition of Cement concrete in ground floor or paving n.exc 15 cm thickness (below or above ground level) and removing rubbish off the premises all as directed.
Demolition of cement concrete of any description & in any position not otherwise specifically provided for.(Roof Kerbs) and removing rubbish off the premises all as directed.
Demolition of reinforced cement concrete of any description and in any position and removing rubbish off the premises complete all as directed.
Demolition of brick work or stone/ boulders masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles and removing from site complete all as directed.
Taking down chowkhats or frames not exc 1.5 sq m each (with out taking off shutter from the frame) and removing from site complete all as directed.
All as per item No 5 here-in-before but area exc 1.50 sqm and n exc 4.00 sqm each.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing u/s tiles and rubbish off the premises complete all as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors etc and removing from site complete all as directed.
Taking down cement plaster on brick of stone walls or concrete surfaces etc incl racking out joints, hacking for key, scrubbing down with water etc and removing rubbish off the premises complete all as directed.
Dismantling of battens for tiles of any size including tilting fillets spacing exc. 15 cm and removing from site complete all as directed.
Dismantling of single layer manglore pattern tiles and ridge in roofing and removing from site complete all as directed.
Dismantling ceiling boards of any type or any description of any thickness including cover fillets etc complete and removing from site complete all as directed.
Dismantling timber scantling 40 Sqcm and over in section as in unframed work and removing from site complete all as directed.
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof covering and removing from site complete all as directed.
Demolition and breaking of drain pipes AC/CI/PVC including all fittings set in cement mortar or adhensive all as directed of 75 mm to 110 mm dia.
Taking down GI tubing & connection 15mm bore laid in floor / trenches or fixed to walls and removing from site complete all as directed.
All as per item No 16 here-in-before but 20 mm bore.
M & L RCC (1:1.5:3 ) type B-1 (20mm graded aggregate) in slabs supported on walls, beams and columns and in shelves and the like complete all as specified and directed.
All as per item No 18 here-in-before but in beams, cantlevers, lintels over 1.5 m spam etc.
All as per item No 18 here-in-before but in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
M & L for PCC (1:3:6) type C1 using 20mm graded agg. for fixing hold fasts etc. complete all as specified and directed.
M & L for precast PCC solid block masonary exceeding 10 cm in width with solid blocks of PCC (1:5:8) grade C-5 and setting in cm(1:6) complete all as specified and directed.
M & L for precast PCC solid block masonry n. exc 10 cm width, using blocks of Grade D4 (1:5:8) set and jointed and built in cement mortar 1:4 complete all as specifed and directed.
M & L PCC (1:3:6) type- C-1 (using 20 mm graded stone aggregate) as in roof kerbs , rounded or chamfered on edges, including necessary form work complete all as specified and directed.
Cutting openings through brick wall built in cement mortar, for door, windows and other openings or enalrging existing openings, etc or cutting out defective masonry for underpinning including providing fixing and removing, shoring, cleaning and rubbish off the premises complete all as directed.
Cutting holes in brick built in CM for inserting hold fast and making good dismantled portion in CM 1:3 exc. half brick but n.exc. one brick thick wall complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
All as per item No 27 here-in-before but cutting exc 10cm but n exc 20cm girth.
Use and waste of formwork to sides and soffits of floor and roof beam beamhaunching girders, bressummers, lintels, cantilevers shelvesincluding support overhanging etc also splys between floors and beam etc, flat rough finished surface of concrete complete all as specified and directed.
All as per item No 29 here-in-before but to soffits of suspended slab such roof slab, floor slab etc.
M & L for 2nd class hardwood, clean sawn, scantling secured with nails as in fillet, rafter, purlins etc over 40 sqm in section complete all as specified and directed.
M & L for plain fillets, square rectangular or triangular in section exc 13 & n exc, 25 sqcm, clean sawn, secured with nails or brads complete all as specified and directed.
S & F 35 mm thick Flush shutters, solid core construction, with particle board core and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed.
S & F 35 mm thick glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, The size of the rail and stile as per IS 1003 (part -I), Kiln seasoned and chemically presure treated as specified and directed.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, in opening as per specification and drawing complete.
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles end plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded seat to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement and fixed in the frame at site as per specification and drawing all as specified in SSR part II complete.
S & F mild steel butt hinges, medium weight 100mm size complete all as specified and directed.
S & F mild steel barrel tower bolts, 200 mm long stove enamelled black, with bright bolt complete all as specified and directed.
S & F mild steel pressed handle,150 mm long oval type, stove enamelled black complete all as specified and directed.
S & F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed.
S & F 75 mm long stainless steel butt hinges for PVC door shutters complete all as specified and directed.
S & F in repairs 200 mm size aluminium, anodised barrel tower bolts of extruded section and fixed to shutter complete all as specified and directed.
S & F in repairs 150mm size extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
S & F in repairs 75 mm long of aluminium anodised barrel tower bolts of exttruded section complete all as specified and directed.
S & F 125 mm size hasp and staple safety type aluminium with steel hinge pin incl bolt to hinge plate and fixed witth screws complete all as specified and directed.
S & F in repair 30mm width of flap brass continuous (piano) hinges for cup board shutter complete all as specified and directed.
S & F 125 mm long brass fancy type cupboard handles fixed with nuts, screws and washer of brass polished complete all as specified and directed.
S & F Megnetic catcher for cabinets all as specified and directed
S & F aluminium powder coated fancy type curtain rod 25mm bore complete all as specified and directed.
S & F aluminium powder coated brackets suitable for 25mm bore curtain rod (minimum projection from wall 75mm) fixed in wall including drilling, rawl plug, screws etc complete all as specified and directed.
S & F in repairs 300 mm long MS ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
S & F mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking bending spirlly for hooping for column, hooping ends and binding with and including mild steel wire not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F mild steel TMT bar 8mm dia cut to length bent to shape required including cranking bending as in stirrups, binding with and including mild steel wire not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F MS work in small articles such as hold fast etc. all as specified and directed.
S & F for mild steel clamps, bands straps, supports or stays for soil waste pipe & rain water pipes including fixing clamps with coach screws etc complete all as spd and directed.
S & FL mild steel rolled section as in joist, channel, angle, rafter, purlins or tee sections, fixed independently, without connecting plates etc (cut to ordinary lengths i.e within 20 mm of the length indicated) confirming to Fe-290 (Gde E-165) complete all as specified and directed.
S & F framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, framed work of watertanks and similar work confirming to Fe 290 Gde -E-165 complete all as specified and directed.
S & F Steel windows with side hung shutters including projecting type hinges with steel handle, steel peg stay, complete with glazing bars, dovetailed or welded. complete all as specified and directed.
S & F steel ventilators with top hung shutter including hinges steel peg stay, complete all as specified and directed.
S & F pressed steel frames of size 125x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified and directed.
S & F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S & F three track aluminium powder coated sliding window with two or more shutter witth 4 mm thick tinted glass , one shutter of stainless steel wire cloth 0.36 mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing, handle lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified directed by Engr-in-Charge. (a) Bottom frame 20620 (b) Top frame & Verrtical 20621 (c) Handle (side) 20606 (d) Shutter inter lock 20724 (e) Shutter top & Bottom 20844 (f) Glazing Clip 19352
S & F Aluminum single leaf door on pivots of powder coated frames alongwith hydraulic door closer (Aluminium Extruded section), door lock, handles, 5mm thick tinted glass in top and 12mm thick prelaminated particle board (both side laminated) in bottom panel, fixed with rubber beading and glazing clips and using as given in 'JINDAL' Catalogue complete all as directed by Engineer-in-Charge.
M & L for aluminium anodised louvered ventilator using aluminium section including frosted glass 4mm thick and stainless steel wire mesh 0.36mm dia of wire and 1.40mm aperture complete all as specified and directed.
S & F Pre painted galvalume aluminium zinc coating GI basedcorrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /clading to wall xed with self taping screws as specified and directed.
All as per item No 65 here-in-above but plain sheet on ridges.
M & L for 10 mm thick gypsum board sheet for ceiling on and including Aluminium powder coated grid work 60cm x 60cm with using 36.5 mm x 23.5mm x 1.5mm thick main tee, 23.5 x 23.5mm x 1.28mm cross tee, and 25mm x 25mm x1.5mm angle fixed to wall for false ceiling including necessary nuts for securing frame work to ceiling suspended @ 120cm C/C both ways, size of grid shall be 605mm x 605 mm complete all as specified and directed.
M & L for POP false ceiling 12 mm thick plain gypsum board on and including GI grid frame work consisting grid and GI main tee 32 x 24 mm, cross tee 25 x 24 mm and angle of walls of size 20 x 20 mm all made out of 0.50 mm GI sheet size of grid not less than 600 x 600 mm hung from ceiling using 2 mm GI wire suspendors spacers at 1.2 mtr c/c on main runners including making nitches for lights, fans, decorative/ concealed light fittings and fasteners if required complete and including two coats of oil bound distemper over a coat of primer all as specified and directed by Engr-in-Charge.
M & L for decorative POP cornices/ moulding of pattern of cross section area exc 13 sqcm and not exc 25 sqcm complete all as specified and directed.
S & F in repair 18 mm thick MDF board prelaminated both side with decorative choice lamination as in Office Cabinet, pelmet box,drawer, CB shutter etc fixed with screw including 6mm thick, 1st Class HW (TW) beading all around on edging to timber frame work all as specified and directed.
S & F in repair 5 mm thick MDF board prelaminated one side with decorative choice lamination as in Office Cabinet, pelmet box,drawer, CB shutter etc fixed with screw including 6mm thick, 1st Class HW (TW) beading all around on edging to timber frame work all as specified and directed by Engr-in-Charge .
M & L for water proofing treatment to RCC roof slab, walls, chajjas ets, shall be carried out as specified below and as directed by Engineer-in-Charge including taking down old waterproofing tratement. (a) M&L for 10mm hick plaster screed bed layer in CM 1:3 on concrete surfaces. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coatt of approved bitumnous primer @ 0.20kg/Sqm of area complete all as specified. (c) Laying App polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 kg/Sqm and 4mm thick with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakagge & seepages and rectifying the same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specifed & as directed by Engr in Charge.
M & L chamfer, splays or arris in facework to granite exc 15 mm but n exc 50 mm wide complete all as specified and directed.
M & L PCC 1:4:8 type D-2 (40mm graded stone aggregate) for sub base 75mm thick complete all as specified and directed.
M & L for PCC (1:2:4) type B0 25 mm thick (12.5 mm graded aggregate) in floor to receive top layer like tiles etc complete all as specified and directed.
M & L for PCC (1:2:4) type B2 using 40mm graded aggregate 100mm thick as in hard standing complete all as specidied and directed.
M & L for non skid digital coloured ceramic tiles (of any colour) in flooring 7 to 8 mm thick area of each tile exceeding 0.11 sqm and not exc 0.18 sqm with joint free tiles set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick cement screed bed in CM 1:6 complete all as specified and directed.
All as per item No 77 here-in-before but area exc 0.06 sqm and n exc 0.11 sqm each.
M & L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, over and including 15 mm thick cement screed bed in CM 1:6 complete.
M & L Glazed Digital ceramic tiles in verticle surfaces of size 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick plaster in C:M 1:4 as abacking coat complete all as specidied and directed.
All as per item No 80 here-in-before but glazed ceramic tiles of size 300 x 200 x 7 mm.
M & L (Dark shade) Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 all as specified and directed.
M & L (Light shade) Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 all as specified. and directed.
M & L (Light shade) Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10 mm thick cement screed in cm (1:4) in verical surfaces such as skirting /dado complete all as specidied and directed.
M & L for machine cut Kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mix with pigment to match the shade of the slab over and incl rubbing and mirror polishing complete incl 15mm thick screed bed in CM 1:6 complete all as specidied and directed.
M & L for granite 16 to18 mm thick (of any type,any colour) work (table rubbed and polished) for wall lining/ (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. with and including sereed bed 10mm thick in CM (1:3) complete all as specified and directed.
M & L granite ( of any type ) work ( table rubbed and polished ) 18 to 20 mm thick in steps, jambs, pillars, window cill , cooking platform and flooring in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite with and including screed bed or bedding layer 15 mm thick, in CM 1:6 on stone masonry surfaces complete all as specidied and directed.
M & L for coloured glazed chequered cement concrete tiles of size 30 cm x 30 cm x 25 mm thick, with grey cement and pigments, jointed and pointed in neat cement slurry complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work or stone surfaces in CM 1:6finished even and smooth w/o using extra cement complete all as specidied and directed.
M & L for rendering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or stone surfaces in CM 1:4 including mixed with WPC @ 3% by the weight of cement or as per manufacturer's instruction complete all as specidied and directed. Note : WPC shall be measured and paid separately.
Supply only integral water proofing compound.
M & L for 5mm thick plastering in CM 1:3 on concrete on fair faces of bricks or concrete surfaces of ceiling finished even and smooth with thin layer of sagol finish complete all as specified and directed.
M & L for preparation of newly plaster surface of wall and apply two coat of cement base paint complete all as specidied and directed.
M & L for preparation of newly plaster surfce of wall and apply two coats of old bound destemper over a coat of primer complete all as specidied and directed.
M & L complete removal of existing treatment and applying two coats of oil bound distemper over two coat of wall care putty complete all as specified and directed.
M & L for preparation of new wooden surface exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of new untreated surfaces of steel of any description exc 10cm width or girth not other wise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
All as per item No 97 here-in-before but n exc 10 cm in width or girth.
M & L for preparation of old surface of wall and apply one coat of washable acrylic distemper complete all as specified and directed.
All as per item No 99 here-in-before but one coat of white wash.
All as per item No 99 here-in-before but one coat of cement base paint.
S & F 15mm bore GI water tubing medium grade with all fittings and fixed complete to wall or ceiling as specified & directed.
All as per item No 102 here-in-before but 20mm bore.
S & F 110 mm bore PVC SWR pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
All as per item No 104 here-in-before but 75 mm bore.
S & F for 75 mm bore SWR pipes single socketed in any length with rubber ring joints fixed to wall including clamp etc complete all as specified and directed.
S & F PVC (SWR) bends with oval access door of 110 mm bore complete all as specified and directed.
All as per item No 107 here-in-before but 75mm bore.
S & F PVC 75mm bore SWR junction (single 'T') equal or unequal complete all as specified and directed.
All as per item No 109 here-in-before but 110 mm bore.
S & F 110 mm bore PVC SWR vent cowl complete all as specified and directed.
All as per item No 111 here-in-before but 75mm bore.
S & F low density polyethylene pipes (LDPE) 32mm dia of pressure rating 6 Kgs/Cm2 fixed complete to walls ceilings or in floors etc complete all as specified and directed.
All as per item No 113 here-in-above but 40mm dia
M & L PVC (SWR) floor trap with steel grating 75 mm dia including jointing to waste pipe including removing old traps complete all as specified and directed.
S & F PVC Connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S & F in repair chromium plated 15mm dia bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipes complete all as specified and directed.
S & F in repairs 15 mm dia chromium plated 2 way bib cock with wall flange confirming to CAT No. F2002161 of "Cera" or of equivalent model of specified make here in after complete all as specified and directed.
S & F in repair 15mm dia Angular stop clock with wall flange cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron unions complete all as per model No CON-053KN of (Make : Jaquar or equivalent model of specified make given here-in-after all as specified and directed.
S & F chromium plated 15mm dia pillar taps , cast copper alloy with crutch or butterfly handle, screwed down, high pressure or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipes complete all as specified and directed.
S & F in repairs chromium plated pillar cock with 200mm Extension body Cat No. 29021 of make Jaguar ‘‘Fusion' Quarter Turn Series or equivalent all as specified and as directed.
S & F in repairs vitreous china squatting pan Orissa pattern wash down water closet of size 580x440 mm, white, with integral foot rests with P or S trap complete all as specidied and directed.
S & F vitreous china wall hung wash down water closet, with "P" or "S"trap of size 510x365x380 mm snow white colour including soft close cover , outlet/intel gasket confirming to CAT No S1041106, 'CARNIVAL CLEAN RIM' of cera or equivalent model of specified make given here-in-after all as specified and directed.
S & F vitreous china wash hand basin white flat back size 550x 400 excluding taps waste chain and plug and porcelain stopper but incl necessary brackets CP brass wastes coupling and other fittings all as specified and directed.
S & F oval shaped coloured vitreous china WHB table top colonia snow white, fancy type of overall size 595 x 380mm, cat No 7751 of cera or of equivalent model of specified make specified here-in-after including 32mm CP waste coupling, PVC waste pipe etc complete, including granite slab counter of black colour as approved and of size 1.20mtr x 0.60mtr including cutting nitches rounding edges etc complete, horizontally supported by 01 No, of 20mm thick granite slab one side mirror polished complete all as specified and directed by Engr-in-Charge.
S & F PVC flushing cistern low level 10 ltrs capacity including brackets for flush tank, PVC flush pipe and all necessary fittings etc complete all as specidied and directed.
S & F in repairs 5.5mm thick mirror of any size mounted on A.C building board 6mm thick including powder coated aluminium frame complete all as specified and directed.
S & F in repairs, brass CP soap dish confirming to Cat No CAN-1131N as mentioned of make "Jaquar" or quivalent model from specified make all as specified.
S & F in repairs Health faucet as confirming to CAT No. ALD-573 as mentioned of make "Jaquar" or equivalent model from specified make all as directed.
S & F in repairs chromium plated Towel rail 600mm long incl brackets complete all as specified and directed.
S & F in repairs, vitreous china,Half stall type urinal, coloured, with urinal censor complete with necessary fittings all as specified and directed. Make :– Hindware, Senso Art Cat No 60018 Starwhite or equivalent model from specified make all as directed.
S & F in repairs CP toilet paper holder confirming to CAT No. ACN-1151 N of "Jaquar" or equivalent model form specified make all as directed.
S & F in repairs shower rose of chromium plated any colour fixing with 15mm bore pipe complete all as specified and directed.
S & F grating dooms 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed.
S & F in repairs chromium plated towel rail 24" long including built in side brackets as per Cat No. 7711 of make Jaguar ‘QUEEN'S COLLECTION' Series or equivalent model from the specified make all as specified and directed.
S & F repair sheet glass (5-8mm thick) corner shelf 450x100mm including CP railing with bracket complete all as specified and as directed.
S & F stainless steel plate rack made of 1.00 mm thick sheet grade SS- 304 of standard size 36"x36"x8" and of approved quality of finish all as spd and directed.
S & F stainless steel sink with drainage board made of stainless steel 1 mm thick with plugs washers and waste including bedding in cement mortor or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm and bowl size 410 mm X 330mm X 160 mm complete all as specified and directed.
S & F in repairs door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed (Al die cast body) complete all as specified and directed.
S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F 3mm thick sheet glass ordinary quality with oil putty in square n.exc 0.50Sqm in each pane complete all as specified and directed.
S & F in repairs Rotational moulded polyethylene water storage tank double layered, 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ ceiling rose/ light fittings, removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified and directed.
Taking down the existing unserviceable main switch / DBs of any type / capacity / description as existing at site including MCCBs any type and capacity and making good the disturbed surfaces to match with the existing finishes all as specified and directed.
Taking down the existing unserviceable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified and directed.
Taking down ceiling fan of any sweep, keeping with safe custody and refixing the same with replacement of unsv 3 core PVC insulated PVC sheathed 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal, over hauling the fan complete including spray, painting with one coat of synthetic enamelled paint including filling cavities with filler, one coat after cleaning all dust etc all as specified and as directed.
M & L for point wiring complete with and including single core FRLS PVC insulated un- sheathed flexible bright annealed multi stranded copper conductor cables 1.5 sqmm (22/0.30mm) 1100 Volts grade ISI - 694 marked, drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as required at site, totally concealed in walls /floors/ceiling/roofs etc. including all conduit/accessories/fittings/junction boxes/inspection covers etc. of heavy grade, ISI marked and modular type sunken boxes with cover factory made including 1.5 sqmm 1100 V grade FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earth wire connected to common earth dolly at other end, complete all the specified and directed. Note- (i) Making good of distrubed surfaces matching with the surrounding will be done by contractor without any extra cost (ii) Cutting in chases and making good will be done by contractor without any cost.
a) One light/fan point controlled by one, One-way switch complete all as specified.
b) One 5 pin 5Amp Socket outlet point on same board with other switches including earth wire complete all as specified.
All as per Item No 148 here-in-above but with stranded copper conductor 2.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent board, including PVC insulated multistranded FRLS copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.
M & L for Point wiring using colour coding as per IS with 1.5 Sq mm multistranded copper conductor single core FRLS PVC insulated sheathed 1100 Volts, ISI-694 marked drawn through and including Casing & Capping on wall /roof/ floor along with suitable fittings, with ISI marked PVC boxes of suitable size for mounting switches/sockets etc along with1.5 Sq mm copper conductor FRLS, PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for the following :-
One light point controlled by one, one way switch.
One ceiling fan point controlled by one, one way switch and regulator.
One three pin 5 Amps socket outlet point controlled by one No one way switch on same board.
One three pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One bell point controlled by one switch.
All as per Item No 150 here-in-above but with stranded copper conductor 2.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated multistranded FRLS copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
S & F modular switch 6A SP one - way 230V white / ivory finish complete all as specified and directed.
S & F modular switch 16A SP one - way 230V white / ivory finish complete all as specified and directed.
S & F modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified and directed.
S & F modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified and directed.
S & F for Switch piano, flush type single pole, one way 5 Amp all as specified and directed.
S & F for Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed.
S & F for Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed.
S & F for Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed.
S & F for ceiling rose 2/3 terminals, PVC/ polycarbonate, isolated body ISI marked complete all as specified and directed.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed.
S & F for Bell, AC. 230 volts, single pole complete all as specified and directed.
S & F for Bell push, flush type, 5 amp complete all as specified and directed.
S & F MCB DB, SPN, sheet metal enclosure, 8 way with 200 amps rated bus bar double door, fixed on wall and making good to disturbed surfaces, and connecting with existing cable complete all as specified and directed.
S & F DB 4 way TPN double door, with mounting arrangements for MCBs and wall fixing arrangements all as specified and directed.
S & F for MCB double pole of rated capacity 32 amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified and directed.
S & F for MCB Single pole rated capacity 6 to 32 amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified and directed.
S & F for MCB four pole of rated capacity 63 amps, 415 volts 50 Hz 10kA C-curve complete all as specified and directed.
M & L for Sub main wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid 20 mm PVC rigid , ISI marked and its accessories duly PVC conduit in wall/ roof / floor including one run of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/ main board complete all as specified and directed.
S & F LED Tube light fittings wall mounted, 18 W LED 6500K with Opal white Poly Carbonate diffuser provided with high efficient integral constant current LED Driver 230 V etc. complete with mounting batten including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to connector Conforming to Cat Part No. BLRB DB 118 & BLRB18 W CW LED Make :- Bajaj or Equivalant in Philips/ Havells complete all as specified and directed.
S & F bulkhead luminaries including LED bulb 10W Make Bajaj Cat part No 112334 BIBWP 10W LED or equivalent in Philips/ Havell's complete all as specified and directed.
S & F in replacement of round recessed mounted pressure die - cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation of cap 15W LED downlighter of white/neutral white color temperature etc, prewired and all accessories complete all as specified and directed Make - Cat part No. ENDURAHODLR15WLED857MOD of Havells or equivalent model in Philips/ Bajaj.
S & F for wall mounted LED tube light fitting 10 watts with output of 1000 lumens , box type (decorative) light fitting, 230 volts with extruded CRCA sheet coated heat sink provided for efficient heat dissipation and integrated electronic driver connector block etc, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 2' x 10 watts complete all as specified and as directed. Make :- Make Bajaj Cat part No BCLSB 10 NW or Equivalant in Philips/ Havell's.
M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete.
L.T Associate
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .