Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹93.6 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹1.5 Cr+₹56.7 L (60.2%)Rejected-AOC 56 ARUNACHALAM MAIN ROAD AMBAL NAGAR PORUR CHENNAI TAMIL NADU 600116 | THIRUVALLUR | TAMIL NADU | 600116 | 2 | Rejected-AOC L2 | |
| 3 | 3₹1.7 Cr+₹79.1 L (84.0%)Rejected-AOC | 3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
7 Nov 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cheif Engineer Hydro
5th,floor,Eastern wing,NPKRR maaligai,Annasalai.Chennai-2
Rectification of sheared Runner bolts by dismantling all Turbine assemblies, Refurbishment of existing Runner with existing turbine shaft, re-assembling,re-alignment of whole unit and Re- Commissioning of the Unit-I 100 MW at Kadamparai PH
2022_EB_258295_1
HE-2443
Open Tender
Electrical and Maintenance Works
Works
90 days
Kadamparai PH
Refer tender documents
4 documents required · 4 mandatory
₹0
₹1.2 L
Yes
1 Dec 2022
27 Oct 2022
7 Nov 2022
27 Oct 2022
7 Nov 2022
27 Oct 2022
Amount
Charges towards the Releasing of the Cooling water pipes, Balancing pipes, Air Pipe lines, Greasing lubrication system pipe lines, Supervisory and Control circuit connections of the Turbine pit area of after proper identification marking.
Charges towards the Dismantling of coupling bolts and Nuts between Generator and Turbine shaft assembly and Removal of the Intermediate shaft (weight: 8500 kg approx) with proper lifting Arrangements such as Lifting Beams, Lifting Stools, muffs and required Bolted/welded Lifting Frame materials with special Tools and Tackles as required at site. Note: (The 1 number of muffs, 2 nos of Lifting beams, 4 nos of 12 T Capacity Hand operated chain Block Trolley Hoists, and 30/150T EOT crane will be provided by TANGEDCO.
Charges towards the Dismantling and Removing the Turbine Guide bearing internals and Oil sump with supporting Ribs after proper prior marking.
Charges towards the Dismantling and Removal the shaft seal Assembly Counter weights, Shaft seal Top cover and shaft seal, Studs, Shaft cone, Static seal and its connected components after proper prior marking.
Charges towards the Dismantling and Releasing of all the Guide Apparatus (G.A) such as Guide vane servomotor's Connecting rods, Links, Levels, Arms and Removal of the Regulating Ring with proper prior marking.
Charges towards the Dismantling and Removal of 24 Numbers of Guide vane Assemblies such as Cover plates, Guide vane Top bearings, and Guide vane bearing Housings, hubs, Levers, Links and seals with proper prior marking.
Charges towards the Dismantling and Removal of the Turbine Top Cover Assembly (weight: 47T ) with Assembling components with proper prior marking.
Charges towards the Dismantling and Removal of the Turbine shaft (weight : 8000 kg approx ) and Runner (weight 15000 kg approx ) after removal of sheared bushes and Runner Bolt and nuts with proper prior marking and required Lifting Arrangements such as Lifting Beams, Lifting Stools, muffs and Bolted,/ welded Lifting Frame materials with special Tools and Tackles as per site requirement. Note: (The 1no muffs , 2 nos of Lifting beams, 4 nos of 12 T capacity Hand operated chain Block Trolly ,Hoists and 30/150 T EOT crane will be provided by the TANGEDCO.
Supply of Guide vane end seals (Quantity :48 numbers) Moulded synthetic Rubber material as per sample suitable for the dismantled guide vane assembly during the Rectification works.
Supply of Runner Stud bolts and nuts (Quantity:6 sets) of size M56 x 265mm Long of B-S- 970 grade material for studs and M56 Hex Nuts of BS-3692 Grade-8 material for nuts. Specifications and dimensions as per the sample one suitable for Reconditioned Turbine shaft with Runner reassembling works.( 1 set = Stud Bolt-1 No.+ Nut 1 No. )
Supply of Runner shear Bushes (Quantity: 6 sets) for the application of 100 MW torque transmission, of size Dia 103 x 205 mm Long or as per finished Bore of Turbine Shaft and Runner, with Retaining Bolts of Size M16 x 220mm long as per sample suitable for Reconditioned Turbine shaft with Runner reassembling works. (1 set = Shear bush1 No. + Retaining bolt 1 No.)
Supply of various sizes fasteners, such as M 24 X 75 mm length HT bolt and nut (10.9 Grade), M 30 X 90 mm length HT bolt and nut (10.9 Grade), M 30 X 155 mm length HT bolt and nut (10.9 Grade), M 36 X 160 mm length HT bolt and nut (10.9 Grade). M 16 X 65 mm length HT bolt and nut (10.9 Grade, M 12 X 30 mm length HT bolt and nut (10.9 Grade), M 12 X 35 mm length HT bolt and nut (10.9 Grade) etc., Supply of Various sizes of O rings and Rubber cords such as 5 mm Dia, 6 mm Dia, 8 mm Dia, 10 mm Dia, 12mm Dia etc., Consumables Such as Molykote grease, M seal, anabond , Gaskets, welding electrode DA gas, Oxygen gas, cotton waste, baniyan waste, emery sheat, auto gasket maker etc.,
Charges towards the Clearing off the burrs and scratches on the upper and lower Wearing ring surfaces, Guide vane faces, Top and bottom cheek plate surfaces and polishing the same, equivalent to the undamaged sectors of the components with respect to its original profile.
Charges towards the Boring and Reaming of existing Turbine shaft and Runner for the correction of the Shear bush holes to match with the turbine shaft Flange holes that suit with the existing runner at factory by using Horizontal/Vertical CNC machines. Note: Shear bush holes in the shaft will be enlarged from 102 to 103/104 according to the ovality of shaft flange/Runner. The same size has to be maintained in Runner. The cost is including transportation of Runner & Turbine shaft from Power House to factory and back to Power House.
Charges towards Complete Re-assembling and Re-alignment of the Reconditioned existing Runner and reconditioned existing Turbine shaft by using suitable new shear bushes and stud bolts & nuts in respect to the wearing Ring, Labyrinth and the machine centre vertical Axis. The prescribed Accuracies in BHEL Manual have to be followed in Re-erection and Re-alignment i.e within the limits of TGB throw 0.09mm and LGB throw 0.03mm based on TGB and LGB bearing condition
Charges towards Complete Re-assembling of 24 Numbers of Guide vane Assemblies such as Cover plates, Guide vane Top bearings, Guide vane bearing Housings, hubs, and end seals after required Rectification works on these components. Re-alignment and Renewal of the worn-out fasteners, O-rings , dowels and minor Assembling parts as required The Re-assembling accuracies to be followed as per BHEL standards. i.e All the Guide vanes adjacent gaps should be within +/- 0.25 mm.
Charges towards the Complete Re-assembling of Turbine Top Cover Assembly (weight:47T ) after Rectification works, Re-alignment, and Renewal of the worn-out fasteners, worn out Dowels, O-rings and minor Assembling parts as required. The Re-assembling accuracies to be followed as per BHEL standards. While Re-assembling the Top cover the accuracy of Equi-Distance between Top and bottom cheek plates have to be maintained Top cover Flanges Tightening Torque should be 1650 kgm.
Charges towards the Complete Re-assembling of the released Turbine Shaft Top cover and Shaft Seal Assembly such as Static seal, Shaft Cone, Shaft Seal, Stud, Shaft Seal Cover, Counter Weights and Re-alignment of the shaft seal assembly with grubbed shaft cone on the shaft and connected components after the Rectification works by Renewal of the worn-out fasteners, O-rings, dowels and minor Assembling parts as required. The Re-assembling accuracies to be followed as per BHEL standards. i.e The nominal static clearance is 0.75mm between inner cover and shaft OD. (The shaft end seal, shaft cone and counter weights will be supplied by M/s. TANGEDCO)
Charges towards the Complete Re-assembling of the entire dismantled TGB Components such as Turbine Guide bearing oil sump with supporting Ribs, all the Bearing internals, Re-aligning back , O-rings and minor Assembling parts. (All the rubber O-rings, fasteners, worn out dowels have to be renewed and other minor assembling parts is concerned of the above dismantled old materials have to be renewed.) The Re-assembling accuracies as per the BHEL Standards i.e (TGB Clearances : 0.15 to 0.20mm )
Charges towards the Complete Reassembling of all the Guide Apparatus (G.A) such as Guide vane servomotors, Links, Levers, Arms and the Regulating Ring, after the Rectification works with perfect Re-alignment and Renewal of worn-out fasteners, O-rings and minor Assembling parts. The Reassembling accuracies are to be followed as per the BHEL Standards. The Guide vane levers assembly to be set to slip Torque of 5000/6500 Kgm. For Links slip Torque is 12500/16250 Kg. Complete Re-Erection of the dismantled Intermediate shaft by coupling with the existing Generator Rotor and Turbine shaft which includes renewal of worn out fasteners for the coupling guard and minor assembling parts ( The coupling stud bolts tightening Torque has to be 2.315 Tonne metres with a nominal elongation of bolts to 0.265mm).
Charges towards the Complete Reassembling of all the Cooling water pipes, Balancing pipes, Air Pipe lines, Greasing lubrication system pipe lines, Supervisory and control circuit connections from the works with the Renewal of worn-out fasteners, O-rings and minor Assembling parts.
Charges towards the Complete Re-alignment of the whole unit (Comprising of Generator, Rotor, Turbine, Turbine shaft, Intermediate shaft and all the Rotating parts with the Existing static components and fixed References of the unit-1. The Values achieved in leveling, Rotor centering, Run-out readings, throw, Labyrinth and bearing clearances by the Re-alignment have to be as per BHEL recommended standards. i.e UGB, LGB, TGB radial clearance is within 0.2mm; Turbine Labyrinth clearance within 1.0mm; lower wearing ring axial clearance to be within 10mm + 1mm; TGB radial throw within 0.09mm; LGB radial throw within 0.03mm.
Charges towards the Dynamic Balancing of the whole Rotor assembly of the Unit to achieve the accepted vibration Levels, as per I.S. (Vibration in Top Bracket and in all the three GTGB, GBGB and TGB Bearings have to be proved to be within the Limits as furnished in Special condition Point– A) and Successful Commissioning of the Unit-1 of Kadamparai power house, for a continuous running of 72 Hours with full load. (Within prescribed Parameters as furnished in Special condition Point – B).
CGST in % (For Bidders inside TamilNadu)
SGST in % (For Bidders inside TamilNadu)
IGST in % (For Bidders outside TamilNadu)
SHREE ABIRAMI ENGGINEERING WORKS
NELLAI ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .