Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount |
|---|---|---|
| 1 | ₹11.1 L M S M A CONTRACTOR VILLAGE RAIPUR MASJID WALIGALI SEC 126 NOIDA U P PH 98102345032 |
Tender Value
₹70.4 L
EMD Value
₹70,391
Closing Date
8 Aug 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Civil, Electrical, Interior and E and M etc
NSL/CEO/IIPA/NIT/2025/766
NSL/CEO/IIPA/NIT/2025/766
Open Tender-Domestic
Miscellaneous
New Delhi, Delhi
₹2,950
₹70,391
7 Oct 2025
31 Jul 2025
8 Aug 2025
8 Aug 2025
8 Aug 2025
BILL OF QUANTITIES (BOQ)
S.No. Sub-Head DSR Amount (in Rs.) NDSR Amount (in Rs.)
1 CIVIL & INTERIOR WORKS 9,08,458.25 11,92,810.00
GRAND TOTAL 70,39,076.00
GRAND TOTAL 70,39,076.00
Digitally signed by AMIT
RENOVATION WORKS AT COURTYARD (RIGHT WING) IIPA, NEW DELHI
S.No. Ref. No. / DESCRIPTION UNIT QTY RATE AMOUNT MARKET RATE AMOUNT
Providing and fixing double scaffolding system (cup lock type) on the exterior side of
building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding
in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre
centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube
challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining
1 24.2 it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying sqm 225.00 338.25 76,106.25
chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners,
connecting with the building etc, wherever required, if feasible, for inspection of work at required
locations with essential safety features for the workmen etc., complete as per directions and approval
of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for
payment purpose. (2) The payment will be made once only for execution of all items for such works.
1.1 13.110 PAINT Finishing walls with textured exterior paint of required shade :
13.110.1 Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. SQM 250.00 169.20 42,300.00
Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer using structural steel etc. as required.
10.25.2 STEEL WORKS In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works kg 3,200.00 172.60 5,52,320.00
3 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.61.1 ENAMEL PAINT Two or more coats on new work SQM 1,500.00 155.90 2,33,850.00
Preparation of complete set of civil and interior finishing drawings including details. A qualified
professional for the purpose shall be appointed after due appproval from Engineer In Charge.
Providing and fixing of terracota jaalis on wall as per approved design and sample at all levels
5 MR jaali complete including all fixing accessories as required complete in all respects as per instructions of nos 120.00 2,700.00 3,24,000.00
engineer-in-charge.
Providing and fixing 6mm thick poly-carbonate sheet with 40% transparency as per vendor and to be
matched with existing on roof of the attrium including cost of removing of existing roof sheet and
dumping/ storing the same as per instruction of Project in charge, including cost of all necessary fixing
arrangement, framing wherever required complete with all respect as per manufecturer details and
specification and instruction of Project in charge/ Architect. (the cost to including scaffolding). The
cost to include dismantalling of existing roof sheet and disposing it to nearest duping yard.
Digitally signed by AMIT
RENOVATION WORKS AT COURTYARD (RIGHT WING) IIPA, NEW DELHI
SUB HEAD NDSR AMOUNT (Rs.) DSR AMOUNT (Rs.)
2 LIGHTING FIXTURES Rs. 7,092.00 Rs. 36,701.00
3 CABLE TRAY Rs. - Rs. 47,880.00
4 SOLAR PANEL Rs. - Rs. 44,67,000.00
5 FIRE DETECTION Rs. - Rs. 37,584.00
GRAND TOTAL Rs. 49,37,808.00
GRAND TOTAL Rs. 49,37,808.00
Digitally signed by AMIT
RENOVATION WORKS AT COURTYARD (RIGHT WING) IIPA, NEW DELHI
DSR-2022/ Description
S.No Unit Qty Rate MR Amount DSR Amount
Point wiring for light point /Fan/Exhaust Fan point/ call bell point using 2 runs of 1100 V grade 1.5 sqmm &
one run of 1.5 sq.mm FRLS insulated multistranded copper wires, in & including 25 mm dia , MS conduit
1.1 surface/ concealed in wall / ceiling conferming to IS 732 including all accessries such as junction boxes ,
conduit bends, elbows and ceiling rose , and anodised GI switch box with modular switch ,modular plate
and the box covered with front plate
a 1.3.3 One light point controlled by one 6A switch Per Pts 7.00 1,845.00 12,915.00
Secondary light point controlled by same switch
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed steel conduit as required.
a 1.7.1 2x1.5sqmm+1x1.5sqmmearth wire 150.00 327.00 49,050.00
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Per
2 X 4 sq. mm + 1 X 4 sq. mm earth wire Per
1.3 1.3.3 Exhaust fan point including of ceiling rose near fan. Per Pts 2.00 1,845.00 3,690.00
Wiring for twin control point wiring using 1.5 sqmm copper conductor FRLS PVC insulated copper
conductor cable drawn through 25 dia MS conduit laid in surface/concealed over false ceiling or in
slab/wall chases including ,2way modular switches,modular plate ,suitable GI box and earthing the point
with 1.5 sqm FRLS PVC insulated copper conductor single core cable as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supply and fixing of following sizes of MS conduit along with accessories in surface /recess including
1.6 1.20 painting in case of surface conduit,or cutting the wall and making good the same in case of recessed
conduit as required
Total of Wiring carried over to summary 0.00 3,41,551.00
2 LIGHTING FIXTURES
Providing & Fixing Heavy Duty 4 Blade, 15" Exhuast Fan complete with all hardware and connectors etc., as
per the direction of the engineer In charge
1.3 LED Down lighter (SMD Type) (System lumen efficacy >135 lm/Watt)
Digitally signed by AMIT
RENOVATION WORKS AT COURTYARD (RIGHT WING) IIPA, NEW DELHI
DSR-2022/ Description
S.No Unit Qty Rate MR Amount DSR Amount
Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round
/square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and
construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating
voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge
protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified
Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life
time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80
extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) ,
SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the
specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.).
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its
own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections
with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with
Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from
NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as
approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum
housing such that LED junction temperature shall not rise above 90°C).
Powder coated die cast / Extruded aluminum Body including trim.
Total of Light Fixture carried over to summary 7,092.00 36,701.00
Supply, fabrication and fixing of steel frame work in position for cable tray/Panels fabricated out of 10 mm
dia GI rods, ISA-40 MS angle iron, ISMC-50 channels, flats etc.complete with providing of Anchor fastners
3.1 and all necessary hardwares as required for fixing, including cutting, bending, welding, drilling, bolting etc.
as per design as required and painted with one coat of primer and two coats of enamel paint of
approved shade.
Supply and fixing of Perforated type 2mm thick Hot dip Galvanised G.I. cable tray of following sizes
complete with bend/tee joints, coupling plate & nuts bolts etc. as required for fixing and including the cost
of providing loop earthing with 2 nos. 50 mm x 6 mm GI earth strips complete as per specifications, as
required and as below.
Total of cable tray carried over to summary 0.00 47,880.00
Digitally signed by AMIT
RENOVATION WORKS AT COURTYARD (RIGHT WING) IIPA, NEW DELHI
DSR-2022/ Description
S.No Unit Qty Rate MR Amount DSR Amount
Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE
specifications as amended, consisting of Mono/ Poly Crystalline silicon solar cells, net metering facility, necessary
protections, earthing, mounted on Aluminium/ GI structure of suitable strength with following components complete
as required:-a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS
14286/ IEC 61215, IS/ IEC 61730- Part-, IS/ IEC 61730-Part-2 .Solar Photovoltaic Module conversion efficiency shall not
be less than16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt
DSR Solar capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power
photovoltic Conditioning Unit(PCU)of 350-800 VDC Input volt age range and 400 VAC, three phase, 4wire, 50Hz+/-2.5Hz, output
power plant voltage suitable to generate ACP ower with efficiency not less than 97%, total harmonic distortion less than 3% and
2019 suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit
the Grid Voltage Frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box &
Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with
glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f)Connections &
Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power
and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of
necessary channel/ conduit lugs and other accessories etc. as required.
Total of cable tray carried over to summary 0.00 44,67,000.00
Digitally signed by AMIT
ESTIMATED COST FOR FA & PA SYSTEM
A. SITC OF FIRE ALARM SYSTEM & ACCESSORIES : MR. DSR.
Sr. No DSR 2022. No. Description Unit Qty Unit Rate Total amount Total amount
Sr. No DSR 2022. No. Description Unit Qty Unit Rate Total amount Total amount
Supplying, installation, testing & commissioning of intelligent analog
1 17.2.4 addressable photothermal detector complete with mounting base Pcs 4.00 2,858.00 11,432.00
complete as required.
Supplying, installation, testing & commissioning of response indicator on
2 17.2.5 surface/recessed MS Box having two LED, metallic cover complete with all Pcs 2.00 276.00 552.00
connections etc as required.
Supply and fixing of following sizes of MS conduit along with accessories in
2 1.20 surface /recess including painting in case of surface conduit,or cutting the
wall and making good the same in case of recessed conduit as required
Digitally signed by AMIT
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT IIPA.pdf
Tender Document
BoQ iipa.pdf
Tender Document
SCC IIPA.pdf
Tender Document
GCC PMC 2022 Upto Amendment 13.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
Forms.pdf
Tender Document
make list IIPA.pdf
Tender Document
corrigendum-4062-corrigendum-I.pdf
pdf • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .