Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC AT PO KALAMCHHUIN DIST ANGUL PIN 759103 | KALAMCHHUIN | ANGUL | ODISHA | 759103 | L1 | Accepted-AOC techno-commercially eligible L-1 bidder. | |
| 2 | Rejected-Technical AT KUMUNDA PLOT NO 6233 8830 PRAGATI NAGAR ANGUL ODISHA | ANGUL | ANGUL | ODISHA | 759143 | - | Rejected-Technical AS PER NIT | |
| 3 | Rejected-Technical AK PO GHANTAPADA TALCHER ANGUL ODISHA | TALCHER | ANGUL | ODISHA | - | Rejected-Technical AS PER NIT |
Tender Value
₹11.0 L
EMD Value
₹13,800
Closing Date
15 Mar 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
STAFF OFFICER (ENM), HINGULA AREA
STAFF OFFICER(ENM), OFFICE OF THE GM HINGULA AREA, MCL, TALCHERPO NS NAGAR, ANGUL, ODISHA, 759148
Diversion of 6.6KV P-5 feeder from existing TP at Puri Sahu chowk towards west side due to diversion of 33KV Hingula feeder of Balram OCP.
2024_MCL_302656_1
MCL/GM/HA/EnM/ e-Tender/23-24/56 Dt.25.02.24
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
BALRAM OCP, HINGULA AREA
AS PER NIT
4 documents required · 4 mandatory
₹13,800
7 May 2024
26 Feb 2024
18 Mar 2024
26 Feb 2024
15 Mar 2024
27 Feb 2024
26 Feb 2024 - 1 Mar 2024
Amount
Item Description/ Heading
Erection of metallic pole of following length in cement concrete 1:3:6(1Cement: 3 coarse sand:6 graded stone aggregate 40mm nominal size) foundation including excavation & refilling etc. as required. (Above 11m and up to 13 m)
Supplying & erection of stay set complete (galvanized) with 19/20 mm dia x 1.8 metres long stay rod, anchor plate of size 45cm x 45cm x 7.5mm, thimble, stay clamps, turn buckle (20mm x 60cm), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation & refilling etc. as required.
Supply of steel for H.T. overhead lines.
Fabrication & erection of steel materials for H.T. overhead lines.
Supply of 11KV,5KN polymer pin insulator- 32mm dia (total length of pin should be 404.40mm & thread part of the pin should be 165.10mm)
Supply of 11KV, 90KN polymer disc insulator.
Supply of 11KV, 90KN polymer disc insulator hardware fittings.
Erection of disc/pin insulator for 11KV/ 33 KV overhead lines as required.
Erection of all aluminium conductor of 7/3.40mm to 7/4.00mm(125sqmm) diameter and above including binding etc.
Supply of 08 SWG G.I. wire
Erection of G.I. wire No. 8 SWG including binding etc.
Making of G.I. net cradle guard and its erection with fabrication & erection of its steel materials.
Excavation of earth and Earthing with G.I earth plate 600mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meters long etc. with charcoal/coke and salt as required.
Erection of GOAB for HT Overhead line including steel materials, pipe etc.
Complete maintenance of 11KV grade, 800Amps double break GOAB Switches with proper alignment for smooth operation including change of post insulator ,conductor ,steel materials, nut bolts and other accessories as per requirement
Supplying and erection of three piece polymer make type lighting arrestor suitable for 3 wire, 6.6kv overhead lines with rated voltage 6KV (rms) with a nominal discharge current rating of 5KA and complete with galvanised clamping arrangement ,G.I. bolts ,nuts, washers etc. as required
Supply and fixing of Nut & Bolts.
Change of polymer make 33/11 KV grade pin insulator on a single pole. Shifting of materials from workshop to worksite & worksite to workshop, dismantling of 3 sets porcelain pin insulator & erection of 3 sets polymer pin insulator including binding etc. as required.
Change of polymer make 33/11 KV grade disc insulator & pin insulator on a double pole.Shifting of materials from workshop to worksite & worksite to workshop, dismantling of 6 sets ( 3 nos disc insulator & one set hardware / set ) of porcelain disc insulator & 3 sets porcelain pin insulator & erection of 6 sets of polymer disc insulator & 3 sets of polymer pin insulator including restringing of disc to disc&binding etc. as required
Change of polymer make 33/11 KV grade disc insulator & pin insulator on a triple pole &four pole structure. Shifting of materials from workshop to worksite & worksite to workshop, dismantling of 6 sets ( 3 nos disc insulator & one set hardware / set ) of porcelain disc insulator &9 sets porcelain pin insulator & erection of 6 sets of polymer disc insulator &9 sets of polymer pin insulator including restringing of disc to disc&binding etc. as required.
Strengthening of base of damaged HT pole by muffing.
Dismantling of Pole/street light standard/Strut embedded in cement concrete foundation etc. as required.
Dismantling of Overhead line comprising of copper / aluminum overhead conductor, G.I wire, Cross arms, insulator etc. as required.
Loading and unloading of materials from E&M workshop to worksite and work site to workshop.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
Sachin Kumar Pradhan
SANJAY KUMAR SINGH
techsummary_313524.pdf
PDF • 0.39 MB
finsummary_313524.pdf
PDF • 0.37 MB
LOA_56.pdf
PDF • 1.83 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .