| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC AOC | |
| 2 | L2₹12.2 L+₹92,760 (8.22%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹12.7 L+₹1.4 L (12.3%)Rejected-Finance | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹13.2 L+₹1.9 L (17.1%)Rejected-Finance | L4 | Rejected-Finance NOT A LOWEST BID | |
| 5 | L5₹13.5 L+₹2.2 L (19.9%)Rejected-Finance | L5 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹18.4 L
EMD Value
₹36,800
Closing Date
31 Jan 2020, 6:00 pmClosed
GE MH AND RH KIRKEE
GE MH AND RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIRS TO INTERNAL WATER SUPPLY CLEANING OF WATER TANKS AND OTHER RELATED WORKS AT MH AND RH AREA KIRKEE UNDER GE MH AND RH KIRKEE
2019_MES_310167_2
8089/E8
Open Tender
Civil Works
Works
180 days
KIRKEE AND AUNDH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE MH RH KIRKEE
₹36,800
Yes
14 Feb 2020
13 Jan 2020
1 Feb 2020
13 Jan 2020
31 Jan 2020
20 Jan 2020
Amount
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store and S & F 15 mm bore tubes, medium grade, galvanised, with all fitting & fixed complete to walls & ceiling or laid in floors all as specified and directed.
All as per item No 1 above but Fixing only tubes of 15 mm bore.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store and S & F 20 mm bore tubes, medium grade, galvanised, with all fitting & fixed complete to walls & ceiling or laid in floors all as specified and directed.
All as per item No 3 above but Fixing only tubes of 20 mm bore.
Taking up or down 25 mm bore steel tubing/kitec tubing and connections, including cleaning for re-fixing or removal to store and S & F 25 mm bore tubes, medium grade, galvanised, with all fitting & fixed complete to walls & ceiling or laid in floors all as specified and directed.
All as per item No 5 above but Fixing only tubes of 25 mm bore.
Cutting chases, pinning in brick walls, making good to facing where required and pointing in cement mortar (1:3) and making good , cutting n.exc 10cm girth , all as specified
S & F in repair PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32 mm bore PVC flush pipe etc complete all as specified and directed.
S & F in repairs PVC connection of 450 mm length, suitable for 15 mm bore pipe with PTMT nuts all as specified and directed.
S & F in repairs PVC connection of 600 mm length, suitable for 15 mm bore pipe with PTMT nuts all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises and M & L ceramic non skid coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc., as in floors etc laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile surface all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises and M & L glazed ceramic coloured tiles 350x250mmx7mm/450X350X7 mm thick conforming to IS 13712 Gde BII(b) set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 10mm thick rendering in cement mortar 1:4 as in skirting and dado all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises and M & L glazed ceramic coloured tiles 300x200mmx7mm thick confoRMing to IS 13712 Gde BII(b) set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 10 mm thick rendering in cement mortar 1:4 as in skirting and dado all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises and M&L vitrified ceramic coloured tiles 10 mm thk (Square/rectangular) area of each tile not exceeding 0.36 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1:6 all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises and M & L Vitrified ceramic coloured tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 as in skirting and dado all as specified and directed.
S&F in repair vitreous china wash basin white size 550x450 mm flat backexcluding taps waste chain and plug and porcelain stopper but including brackets cutting for pinning in ends of brackets of erecting stand but exclusive of fixing of supply and waste pipe all as specified and directed.
S&F in repair Vitreous china urinal flat back of size 465X355X265mm white (min) with grating & union for discharge pipe including Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Minimum weight 60gms) but excluding flushing cistern, flush pipe & waste pipe but fixing only automatic flushing cistern with bracket flush pipe etc complete all as specified and directed.
S&F in repairs PVC (SWR) pipes 110 mm dia single sockets, in any length rubber ring joints, laid in trenches or in floor or on wall all as specified and directed.
S&F in repairs PVC (SWR) 110mm dia bends any radius all as specified and directed.
S&F in repairs PVC (SWR) branch 110mm bore piecs, single ( single Y ) equal or unequal all as specified and directed.
S&F in repairs PVC (SWR) junction110mm bore single ( single t) equal or unequal all as specified and directed.
S&F in repairs (SWR) pipes 75 mm dia single sockets , in any length rubber ring joints, laid in trenches or in floor or on wall all as specified and directed.
S&F in repairsPVC (SWR) 75 mm dia bends any radius all as specified and directed.
S&F in repairs PVC (SWR) branch75 mm bore piecs, single ( single Y ) equal or unequal all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as specified and directed.
S & F in repairs wash down water closet ( European type) excluding fixing bolts, flushing cistern, & flush pipe but including connecting to existing out let pipe etc all as specified and directed.
S & F in repairs Plastic seat cover to EWC with aluminium hinging device all as specified and directed.
S & F in repairs PVC (SWR) multi floor trap with grating including jointing with solvent cement all as specified and directed.
S&F in repair 15 mm Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed.
S& F in repairs 75 mm Cast iron Nahni trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) using 20mm graded stone aggregate complete all as specified and directed.
S&F in repairs Toilet paper holder of brass chromium plated fixed to walls with chromium plated (CP) brass screws all as specified and directed.
S& F in repairs Soap dish,chromium plated fixed to plugs with chromium plated brass screws complete all specified and directed.
M&L for cleaning of Over head tank of any type (RCC or PVC) not exceeding 250 litre capacity from mouths of circulating pipes etc and dewatering complete by pumping motor set or manually and removing sludge/mud/scales etc settled at bottom, scrapping of floor/wall internally by wire brush and washing floor of tank and wall with diluted Sulphuric acid/bleaching powder to remove the algae thoroughly and clean till surface is clean in all respect and throwing out the sludge /muddy material along with foreign material from inside to outside where directed and writing letters or figures for date of cleaning and capacity of tank with synthetic enamel paint black background & letter /numbers in white colour & words size is 10 cm height on tank complete to the entire satisfaction of Engr-in-Charge and all as specified. ( Note :- Contractor will arrange necessary T&P required for execution of work as per ground in such a way to avoid hampering of water supply to user and same will be done as per instruction & as directed by Engr-in-Charge.)
All as per item No. 34 above but tank capacity exceeding 250 litre and not exceeding 500 litre all as specified and directed.
All as per item No. 34 above but tank capacity exceeding 500 litre and not exceeding 1000 litre all as specified and directed.
All as per item No. 34 above but tank capacity exceeding 1000 litre and not exceeding 2000 litre all as specified and directed.
S.R.M.K Enterprises
s.k.engineers
MANIYA CONSTRUCTION CO.
V.R.PRAJAPATI AND CO.
L.K.R.TIWARI CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .