Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | ₹8.7 L Quoted ₹9.2 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹9.5 L+₹30,812.07 (3.36%)Rejected-Finance | ₹9.5 L+₹30,812.07 (3.36%) | L2 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | YS CONSTRUCTION L1 | m/s sahu enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Disconnecting and taking down existing ceiling/exhasut fan any type and capacity and refixing to the same/other location including testing complete after repair as spfd and directed. | 400 | Job | 22 ₹8,800 | 20 ₹8,000 Lowest |
| 2.00 | M&L for Strip opening of AC ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete and all as specified. | 300 | Job | 25 ₹7,500 Lowest | 25 ₹7,500 Lowest |
| 3.00 | Rewinding of AC ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing ,with gun metal bush ,fan shaft ,ball bearing complete connection with flexible wire of appropriate size two core copper wire upto connector block complete and all as specified. | 200 | Each | 300 ₹60,000 | 250 ₹50,000 Lowest |
| 4.00 | S&F in Replacement of fan capacitor AC 440 volts 2.5/3.15mfd 50HZ complete and all as specified. Make : Epcos/Usha/Havells. | 200 | Each | 25 ₹5,000 Lowest | 35 ₹7,000 |
| 5.00 | S&F in Replacement of fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge. | 160 | Each | 195 ₹31,200 | 185 ₹29,600 Lowest |
| 6.00 | S&F in replacement of fan blade set steel 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan all as required at site. | 35 | Set of Three | 110 ₹3,850 Lowest | 150 ₹5,250 |
| 7.00 | S&F in Replacement of fan motor with body 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan all as required at site. | 30 | Each | 850 ₹25,500 | 500 ₹15,000 Lowest |
| 8.00 | S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin complete all as per sample of size 45 Cm long. | 15 | Each | 30 ₹450 Lowest | 30 ₹450 Lowest |
| 9.00 | All as per item No 8.00 but of size 1 to 2 Mtrs long | 10 | Each | 50 ₹500 Lowest | 90 ₹900 |
| 10.00 | All as per item No 8.00 but of size 3 to 4 Mtrs long | 10 | Each | 160 ₹1,600 Lowest | 180 ₹1,800 |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
28 Jun 2025, 6:00 pmClosed
Offg GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR MAINT OF CEILING FAN, EXHAUST FAN, WALL FAN AND GEYSERS OF OTM MD ACCN OF DMSRDE, MES COLONY AND WAR MEMORIAL COLONY UNDER GE I R AND D KANPUR
2025_MES_710445_1
8438/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kanpur
As per Appx A of NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹26,000
Yes
13 Aug 2025
26 May 2025
30 Jun 2025
26 May 2025
28 Jun 2025
9 Jun 2025
26 May 2025 - 7 Jun 2025
Amount
Disconnecting and taking down existing ceiling/exhasut fan any type and capacity and refixing to the same/other location including testing complete after repair as spfd and directed.
M&L for Strip opening of AC ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete and all as specified.
Rewinding of AC ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing ,with gun metal bush ,fan shaft ,ball bearing complete connection with flexible wire of appropriate size two core copper wire upto connector block complete and all as specified.
S&F in Replacement of fan capacitor AC 440 volts 2.5/3.15mfd 50HZ complete and all as specified. Make : Epcos/Usha/Havells.
S&F in Replacement of fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge.
S&F in replacement of fan blade set steel 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan all as required at site.
S&F in Replacement of fan motor with body 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan all as required at site.
S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin complete all as per sample of size 45 Cm long.
All as per item No 8.00 but of size 1 to 2 Mtrs long
All as per item No 8.00 but of size 3 to 4 Mtrs long
S&F in Replacement of lower and upper canopy of fans of ceiling fans of suitable size required at site as directed by Engr-in-Charge.
Cleaning thoroughly ceiling fans 1200mm / 1400mm sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fan any size / make / sweep for carry out repair/greasing, oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete and all as specified.
Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including ball bearing necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete and all as specified.
Cleaning thoroughly exhaust/wall/podestal fan 225 mm to 450 mm sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
S&F in replacement of fan blade set steel heavy duty suitable for exhaust/ pedestal/air circulator fan 225 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
S&F in replacement of fan motor with body suitable for exhaust fan 225 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
S&F in replacement of fan blade set plastic suitable for exhaust/ pedestal/air circulator fan 225 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
M & L for providing PVC rounded 3 core 0.75 sqmm copper cable and making necessary connection complete all as specified & directed.
All as per item No 19.00 but copper cable of size 1.5 Sqmm.
All as per item No 19.00 but copper cable of size 2.5 Sqmm.
S&F in Replacement of for taking down/out desert cooler from existing place and removing old paint from the body of desert cooler and applying painting on desert cooler external body, fan and pump with a coat of synthetic enamel grey paint , internal body with a coat of synthetic enamel black paint with brush painting at site after proper dusting cleaning and scraping old painted surface and refixing on same/other location after painting complete all as specified and directed.
M & L in replacement of side panels of desert cooler made out of 22 SWG mild steel sheet of size not more than 0.70x0.80 mtr to match with existing cooler as per sample complete with jalli, wood wool pad , fastners painting with two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed.
Supply and fixing in replacement of water lifting pump submersible type 220 -240 Volts 50 HZ as per sample complete all as specified and directed. make as approved by GE.
Supply & fixing in replacement of kit fan motor of desert cooler as per sample, 230 volts complete with blades, fixing legs, nuts, bolts, washers etc of complete all as specified & directed.
S&F in replacement of ready made wood wool pad size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified & directed.
M & L for disconnecting, dismantling, refixing and rewinding of kit fan motor upto 450 mm sweep of desert coolers 230 volts AC 50 C/S with super enamelled copper conductor wire of existing gauge as original including replacement of bush -02 Nos shaft -01 No ring-01 No & clamp-04 Nos complete all as specified & directed
S&F in Replacement of desert cooler stand using angle iron (40 x 40 x 6 mm) making square type platform of min size 800 x 800mm and fixing through two angle iron piece for horizontal support and two angle iron piece for 45 degree angle vertical support into the walls of any type / height as required on site by means of required nuts, bolts, fastners, welding work etc to form a platform suitable for fixing the desert cooler of any size & type compete all as specified and directed. Note: Angle iron should be painted with a coat of red oxide primer and two coat of synthetic enamel paint. Minimum 20 cm length of the angle iron should be inserted into the wall and fixing the same through required PCC work. Cutting chases in walls required for fixing the angle iron support shall be finished with cement mortar 1:4 and surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor.
S&F in Replacement of dismantling, taking out old u/s clamp and fixing with new clamp for kit fan motor of desert cooler as per site requirement with nuts & washers complete all as spfd and directed..
S&F in Replacement of old u/s indicator lamps and replaced with new all as spfd and directed.
S&F in Replacement of old PVC Water distributor four way including PVC pipe as per sample connection comeplete and all as spfd and directed.
S&F in replacement of existing UNSV desert cooler blade as per sample and fix in the desert cooler and all as specified and directed by Engr-in-Charge.
S&F in Replacement of capacitor AC 440 volts 4 mfd 50HZ complete and all as specified. Make : Epcos/Usha/Havells.
Taking down old u/s storage type water heater geyser of cap 25/50 Ltrs from existing location all as spfd and directed.
Fixing only storage type water heater geyser on wall after reapir and replacement of old unserviceable with gutties/anchor bolts or nuts & bolts and fixing the same in existing /other location complete all as specified and directed.
M&L for spray painting of outside surfaces of geyser with two coats of white synthetic enamel paint after preparing surface with and including writing MES No. complete all as specified and directed.
M&L for opening the geyser and replacement of glass wool for insulation of geyser of 25 to 50 ltrs capacity of any make / type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC flexible connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed.
S&F in Replacement of old u/s thermostat switch of geyser 25 to 50 ltrs capacity and replaced with new as per sample with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply as per sample complete all as specified and directed.
S&F in Replacement of u/s heating element of cap 2 KW and replaced with new and testing on completion as per sample complete all as specified and directed by Engineer-in-Charge
All as per item No 43.00 but heating element of capacity 1.5 KW.
S&F in Replacement of old u/s syphon assembly of geyser 25 to 50 ltrs ltr capacity and replaced with new stainless steel syphon as per sample and all as spfd and directed/
S&F in Replacement of 25 liters storage water heater with glass coated anti rust tank with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply , indating lamp connection complete all as specified and directed by Engineer-in-Charge.
S&F in Replacement of single pole and neutral enclousere with a top pin, earth plug and socket copmlete with one SP MCB 25 Amps, 240 Volts.
S&F in replacement of plug top 15 Amps all as spfd and directed.
S & F in replacement of indicator LED bulb square / round type complete with necessary connection wire of red & green colour all as spfd and directed.
Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of window type air conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed by Engr in charge.
Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the window AC of 1.5 / 2 Ton capacity including necessary welding with existing refrigerant pipe, supply & testing complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay shall be measured and paid separately if required under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate. (iii) Old unserviceable hermetic sealed unit and other materials obtained from the window type AC will be accounted under Schedule of credit and same shall become the property of the Contractor
S&F in replacement of cooling coil of window type AC any cap up to 2 ton all as spfd.
S&F in replacement of front grill of window AC suitable for 1.5/2 ton cap as per sample all as spfd and directed.
S&F in replacement of rotary type sealed compressor of window AC 1.5/2 Ton cap as per sample all as spfd and directed.
S&F in replacement of Air blower moter as per sample suitable for window/split type AC of 1.5/2 Ton capacity single phase as per sample all as spfd and directed.
S&F in replacement of starting capacitor suitable for window/split AC of rating 45 - 100 Mfd as per sample all as spfd and directed.
S&F in replacement of starting relay suitable for Window/split AC of capacity 1.5 / 2.0 Ton as per sample.
S&F in replacement of thermostat switch as per sample for window/split type AC of 1.5 /2.0 Ton capacity all as spfd.
S&F in replacement of condenser fan blade suitable for window/split type AC of any make & capacity all as spfd and direceted.
Disconnecting electrically and opening the cover of split AC 1.5/2 ton cap inner/outer unit and servicing incluiding cleaning / removing all dust / mud, oil and other foreign particle from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete including servicing, oiling, greasing complete air conditioner and checking of electrical connection and testing complete all as directed by Engineer-in-Charge.
Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the Split type AC of 1.5 / 2 Ton capacity and fixing only new spares as per model / capacity including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas and testing complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay shall be measured and paid separately under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate.
S&F in replacement of sealed compressor, rotary type, of any make as per sample suitable for split type AC of 1.5/2 Ton capacity all as spfd and directed.
S&F in replacement of Inlet / outlet control valve for outdoor / indoor unit of suitable size, of any make & any type all as spfd and directed.
S&F in replacement of discharge grill of outdoor unit of any size and type for split AC’s all as spfd and directed.
Disconnecting electric , dismantling and taking out outdoor unit split type AC 1.5 ton and S&F in replacement outdoor unit spilt type AC 1.5 ton with connected accessories connection complete all as spfd and directed.
Supply and fixing in replacement of defective remote control hand set with "AAA" batteries for window/split type AC's, of any model / make complete all as specified and directed.
Supply and fixing in replacement of display indication on LCD screen assembly mounted on indoor unit (cooling unit) for split type AC’s, of any model / make complete all as specified and directed.
S&F in Replacement of micron filter suitable for window / split type AC of 1.5 Ton capacity complete all as specified and directed.
S&F in Replacement of capacitor suitable for window/split AC of rating 06 - 20 Mfd as per sample all as spfd and directed.
S&F in Replacement of condenser / cooling coil for air conditioner of suitable size complete as per site requirement and as directed.
Disconnecting electric , dismantling and taking out indoor unit split type AC 1.5 ton and S&F in replacement indoor unit spilt type AC 1.5 ton with connected accessories connection complete all as spfd and directed.
Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC with cooling tubing and other accessories with carefully and deposited to MES store yard complete with outer/inner unit, copper tubing, drain pipe and remort all as spfd and directed.
M&L for fixing/installation of split AC inner/outer or both unit as received from item No 73 with all accessories and making all coonection of copper tubing/drain and electrically and testing on completion all as spfd and directed. Note : Refrigrant and other connecting items i.e copper tube/ drain pipe will be measured and paid seperately under respective item if required.
supply and fixing in replacement copper tube of as per sample including brazing etc. complete all as specified and directed.
supply and fixing in replacement of foamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness complete all as specified and directed.
supply and fixing in replacement of foamed polythene insulating pipe of 8 mm internal dia and 7 mm wall thickness complete all as specified and directed.
S&F in replacement of Main control circuit (PCB) for window/split type AC's, of any model / make complete all as specified and directed.
S&F in replacement of PVC flexible drain pipe 15mm to 25mm dia all as spfd and directed.
M & L for vacuum pump pressurising the system, leakage testing , welding work complete including charging with refrigerant R -22 / R-134a/R-410 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice and after charging gas including testing in all respect for window / split type air conditioner 1.5 / 2.0 TR capacity complete all as specified and as directed.
Supply & fix in concealed or fixed on wall of rigid non-metallic PVC conduit medium grade of size 20/25 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends for drain of AC all as spfd and directed.
Disconnecting, dismantling and taking out old burnt winding of transformer and re-winding the same with super enameled copper winding wire (existing size) for 1 to 5 KVA voltage stabilizers including all necessary insulating material and testing complete and refixing the same in same/other location after repair incl nut, bolt and washers etc all as spfd and directed. Note :
Supply and fixing in replacement of Main relay of voltage stabilizer 1 to 5 KVA as per sample.
Supply and fixing in replacement of Main control circuit (PCB) of voltage stabilizer 1 to 5 KVA as per sample.
Supply and fixing in replacement of replacement of sensor transformer of voltage stabilizer 1 to 5 KVA as per sample.
Supply and fixing in replacement of Time delay relay, 2-3 minute over / low voltage 180 Volts AC and high voltage 260 Volts AC of voltage stabilizer 1 to 5 KVA as per sample.
Supply and fixing in replacement of voltage stabilizer 4 KVA copper wound voltage stabilizer for 1.5 Ton air conditioning complete all as directed by Engineer-in-charge
Taking out water cooler of any make and type of capacity 40 / 80 ltrs from position and cleaning/serviceing the complete condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed.
Disconnecting and taking out defective water cooler of any make for capacity 40 / 80 ltrs for repair including making all electrical/water connection and testing all as spfd and directedall as spfd and directed.
S&F in replacement of sealed compressor as per sample suitable for water cooler of capacity up to 40 / 80 Ltrs as per sample.
S&F in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd as per sample for water cooler.
S&F in replacement of Running capacitor 10-30 Mfd as per sample for water coller/ window ac/ split ac/refrigerator.
S&F in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs as per sample.
S&F in replacement of Starting relay/over load protector of water cooler as per compressor requirement.
S&F in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement.
S&F in replacement of PVC flexible pipe transparent (as per sample) for water cooler.connection complete all as specified
S&F in replacement of PVC float valve with rod & ball for water cooler. Make: Prayag or equivalent.
S & F in replacement of condenser coil with copper tube and aluminium fins for water coolers suitable for up to 40 / 80 Ltrs capacity of any make and type complete all as specified and directed.
M & L for vacuum pump pressurising the system, leakage testing , welding work complete including charging with refrigerant R -22 / R-134a (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice and after charging gas including testing in all respect for any tyep water cooler 40/80 ltrs capacity complete all as specified and as directed.
Point wiring in replacement of one fan/exhaust point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per srl item No 100.00 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controleed by one switch.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts.
S&F switch piano flush button single pole one way 15/16 amps 230 Volts.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts.
M&L for ceiling rose surface bakelite 3 terminals.
S & F in replacement of gun metal iron gate valve 15mm dia with iron wheel head, screwed both ends for iron pipe, ISI marked, complete all as specified .
S & F in replacement of CP push type bib tap 15mm dia for water cooler connection complete, ISI marked, complete all as specified .
M&L in replacement for 6 sqmm 3 core PVC insulated and PVC round sheathed multicore annealed bare copper conductor (flexible) industrial cable for voltage grade 1100 volt connection complete and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge.
m/s sahu enterprises (BID ID -3339910)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .