Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹7.0 Cr
EMD Value
₹14.1 L
Closing Date
30 Nov 2026, 1:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
14 conditions · 3 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V=Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of" total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Annual Contractual Turnover Data for the Previous 3/4 Years should be submitted as per Annexure-IX. (Annexure VIB of Tender Documents)
Technical Eligibility Criteria: (a)The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (i)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed any of the following during last 07seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40%of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(i): Separate completed works of minimum required values for each component shall also be considered for fulfillment of technical eligibility criteria. (c) Similar nature of Work is defined as "Similar nature of Work is defined as "Supply, installation, testing and commissioning of any LT/HT Electrical Work. ." Note: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Similar nature of Work is defined as "Supply, installation, testing and commissioning of any LT/HT Electrical Work".
40 conditions · 9 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
AT TSK Division- Provision of facade lighting of 10 Nos of Amrit Bharat Stations of TSK Division and decorative Street Light in Circulating area at SLGR,SRTN,AGI, MXN ,JTTN,GLGT,NLP,DMC,SPTR & MZS.
LV-T-14-TSK-970~NFR
LV-T-14-TSK-970
Open
Works - General
15 Months
Tinsukia, Assam
₹0
₹14.1 L
6 Nov 2026
6 Nov 2026
16 Nov 2026
54 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,07,08,206 | ||
| for details. | Breakup | — | — | ||
| Supplying Installation, Testing and Commissioning of Circular/ Rectangular/square LED RGB / RGBWW / RGBNW / RGBA/ RGBW (as per site requirement) Facade Floodlight/ Projector luminaire for facade lighting with Pressure Die-cast aluminium housing, powder-coated finish, with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, the scale shall be provided for rotation degrees. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection and impact resistance of IK 07. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 5/10/15/20/25/30/40/45/60 degree. Luminaire should have efficacy of minimum 35 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. Luminare should have dimmer,strobe control also.The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. Lifetime of complete luminaire(LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS: (IS10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with Integral male/female water proof connectors/jumper IP 68 etc. as required. | — | — | — | 1,21,38,956 | |
| — | 540.00 | — | — | ||
| Supplying Installation, Testing and Commissioning of LED RGB/RGBWW/ RGBNW/ RGBA/RGBW suitable for exterior use having IP68 rating (as per site requirement). Flexible light strip of 5 mtr standard length with 12-15 Watt per meter. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control.Minimum System lumens 450 lumens/meter and System Lumen Efficacy > 30lm/w. Luminaire light beam spread - 100-110°, The Strip should have IP 68 protection and is offered IP 68 rated connectors to join the LED Strips in continuity. The luminaire must be offered with Aluminium channel for mounting the strip lights. The product should be complete with all accessories and Driver. Lifetime of complete luminaire (LED, Driver, Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C.Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 24 V DC, Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. | — | — | — | 52,32,060 | |
| — | 456.00 | — | — | ||
| Supply, Installation,Testing and Commissining of Recess mounted LED wall washers of 15 W(Colour temperature as required), tilted 70° outwards and swivels 350° to offer best illumination on the wall. THD <10%(Canopy soffit recessed downlights) | — | — | — | 14,31,840 | |
| for details. | Breakup | — | — | ||
| "Supplying Installation, Testing and Commissioning of LED RGB/RGBWW/RGBNW/ RGBA/ RGBW (as per site requirement) Linear Profile / Wall Washer luminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, having the rotation degrees scale shall be provided. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. CRI>80, SDCM<5,THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. Thereshould be options of beam angles of 10/20/30/40@47<44@ asymmetric degree. Luminaire should have efficacy of minimum 40 lm/W for RGB/ RGBNW/ RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow,medium, wide or asymmetric as per the requirement Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to +50°C and shall have impact resistance of IK 07. Lifetime ofcomplete luminaire (LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with Integral male/female water proof connectors/jumpers of IP68 etc. as required." | — | — | — | 1,67,57,750 | |
| — | 248.00 | — | — | ||
| Supply, installation of decorative wall light 15 Watt IP 66 LED UP-down Luminaire with wall surface mounting using COB LED as light source. | — | — | — | 20,33,600 | |
| — | 80.00 | — | — | ||
| Supply installation of compact, light weight, energy saving,LED 15 Watt IP66 LED spike light using COB LED as light source. | — | — | — | 6,20,000 | |
| — | 40.00 | — | — | ||
| Supply, installation, testing and commissioning of decorative architectural wall mounted light fitting of traditional lantern type, suitable for outdoor/indoor architectural applications, comprising weather-resistant decorative body with black finish, clear transparent protective panels, decorative top canopy and wall mounting bracket, complete with E27 lamp holder, suitable LED lamp, necessary internal wiring, terminals, fixing hardware and all other accessories, complete in all respects as required for satisfactory operation. | — | — | — | 5,64,000 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of Carina Chandelier with Asfour Almaaza Crystal & Gold Finish, complete with multi-tier decorative metal framework, central suspension stem, symmetrically arranged curved light arms and ornamental detailing. The chandelier shall be provided with high-quality Asfour Almaaza faceted crystal pendants and cascading crystal drops arranged in multiple tiers, including the lower crystal fringe, as per approved design. The metal body and decorative components shall have premium Gold Finish. Complete with suitable LED/light sources, lamp holders, internal wiring, connectors, ceiling canopy, suspension arrangement, mounting hardware and all necessary accessories for proper installation and safe operation. Overall dimension shall be approximately 1530 mm diameter x 2300 mm height, suitable for indoor decorative/architectural lighting applications, complete in all respects as per manufacturer's specifications and Engineer-in-Charge's instructions. | — | — | — | 19,30,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCAPRIL2022WITHALLACS.pdf
ATTACHMENT
AnnexuresSectionVII.pdf
ATTACHMENT
TenderDocumentTSK970.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .