Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.9 L+₹8.6 L (22.3%)Rejected-AOC SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹49.3 L+₹11.0 L (28.7%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹49.5 L+₹11.2 L (29.1%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹50.5 L+₹12.2 L (31.8%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹94,680
Closing Date
2 Jul 2021, 5:00 pmClosed
GE GOMANTAK VASCO
GE GOMANTAK VASCO PIN 403802
Provision of Temporary Medical Inspection Room (Flu Covid-19) at INHS Jeevanti Provision of covered boat shed for demo boat at NIH Goa and Replacement of Damaged Roof Sheeting of Various Bldgs due to damaged caused by Cyclone Tauktae at NTRW(G)
2021_MES_451989_1
8277/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE GOMANTAK
₹94,680
Yes
9 Nov 2021
16 Jun 2021
3 Jul 2021
16 Jun 2021
2 Jul 2021
22 Jun 2021
Amount
Schedule 'A' Part I - B/R PORTION
Excavation over areas n exc 1.5 m deep and getting out in soft/disintegrated rock for foundation. all as specified and directed by Engr in charge.
Excavation in post holes(or similar holes) complete all as specified and directed.
M&L cement concrete type C-1 , 1:3;6 (using 20 mm graded aggregate) as in post hole and coping incl necessary form work all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F Rolled mild steel Roof trusses (framed), trussed purlins crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. GDE Fe410-0 or Fe 310-O
Applying two coats of Anti corrosive paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome
Dismantling asbestos cement (corrugated, semi corrugated etc) in roof coverings
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Supply & Fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Anodised aluminium snap grid frame work for false ceiling all as specified size of grid 605x605mm.
S&F hangers 6mm GI(Up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long complete all as specified for false ceiling all as specified .
Supply & Fixing 10 mm thick PVC insulation panels in ceiling board with EPS of net to 1mm printed PVC sheet suitably placed in false ceiling grid all as per specification and drawing
S&F powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F aluminium powder coated Door shutters alumium section weighing 0.55kg/sqm including necessary joining cleats glazing clips rubber neoprene packing handles 2 nos in each door hinges anodised
S&F aluminium powder coated window and ventilator shutters side hung type without sash alumium section weighing 0.55kg/sqm including necessary joining cleats glazing clips rubber neoprene packing anodised aluminum snap beading ,screws anodised aluminium fittings such as peg stays 150mm long(1no) hinges type B-21 100mm long (2no) suitable handle (1no) complete all as specified and directed by Engineer in charge.
S&F 5.5mm thick sheet glass,ordinary qauality and glazing with oil putty in square n exc 05 sqm in each pane
S&F for stairs(framed) including stringers tread,landing ,balusters ,hand rails etc Fe 290(Gde E-165) including cleats brackets etc complete.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock all as specified and as directed
M&L for Cement concrete (1:4:8) type D2 as in foundations, filling and mass concrete all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar, complete all as specified.
M&L for Pre-cast cement concrete type C1 (1:3;6) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4) complete all as specified and as directed.
Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by Engineer-in-Charge. Note : Debris shall be removed outside MD land
M & L 15 mm thick rendering on fair faces of concrete in CM 1:6 finish the surface even & smooth without using extra cement complete all as specified and directed
M & L 15 ( 10+5) mm thick rendering in two layer on fair faces of concrete in CM 1:4 finish the surface even & smooth without using extra cement complete all as specified and directe( NOTE : II nd coat 5mm thick with WPC )
Supply only Liquid water proofing compound.
Material & Labour for providing two coats of oil-bound distemper over a coat of alkali-resistand primer on new plastered surfaces including necessary preparation to surfaces complete all as specified and as directed
Material & Labour for providing one coats of oil-bound distemper over a coat of alkali-resistand primer on old plastered surfaces including necessary preparation to surfaces complete all as specified and as directed
Material & Labour two coats of acrylic emulsion extenior paint (anti fungal painting-APEX or Equivalent) over a coat of acrylic amulsion primer including preparation of new concrete surface of any description all as specified and directed by Engr-in-Charge.
M & L preparation of new plasterd surfaces on wall and applying two coats of cement base paint over one coat of primer all as specified and directed by Engr in charge.
M&L Hardcore broken stone or boulders of gauge exc. 63 mm but n exc 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to true surface
Material & Labour for 100 mm thick PCC type C-2, 1:3:6 (using 40 mm graded aggregate), as in sub base of floor. all as specified and directed by Engr in charge.
M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor finish CM: 1:4 all as specified and as directed.
M&L 50mm thick Sand filling under floors or in foundations including watering and consolidation
M&L for Non Skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular area) of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm set and jointed in neat cement slurry and pointed by matching cement.
M & L Glazed ceramic tiles in vertical surface 300x200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour tiles.
M & L Rendering a backing coat of 10mm thick in CM 1:4 to receive skirting/backing coats of tiles.
Returning, filling in , including, spreading, levelling, watering and well ramming in layers not exc 25cm thick soil complete all as specified and directed
Removing excavated materials (soft/dis integrated rockl) to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
Supply & Fixing Vitreous China wash basin, white,ovel shaped back, size 630x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets.
Supply & Fixing Pillar taps, 15mm dia, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe
Supply & Fixing CP stop cock/angle cock 15mm dia, fancy type with capston heads screwed both ends for iron pipe or for unions
Supply & Fixing Bib taps, 15mm dia, cast copper alloy, fancy type, with capston head, screwed down, screwed for iron pipe or for brass ferrule
Supply & Fixing PVC connections 15 mm size with PTMT nuts of length 600m fixed in repair.
M&L 75 mm dia PVC(SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors
Demolition of stone slabs and tiles of any description or thickness in floors,aprons etc laid dry or laid dry and pointed.
M&L for machine pressed precast concrete interlocking paverblock any shape and size conforming to IS 15658-2006 of 80mm thick M40 grade with grey cement and pigment
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engr-in-Charge
Supply & Fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, for 1000 ltrs capacity.
Material & Labour PCC type B1, 1:2:4 (using 20 mm gradee aggregate) for coping all as specified and directed.
Schedule 'A' Part II - INTERNAL ELECTRIFICATION
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall/ceiling and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light point controlled by one, one way switch 06 Amps.
All as per item No 2 but 2/3 pin socket out let 5 Amps with 1.5 Sqmm on independent board.
All as per item No 2 here-in-before but for 2 in 1 three pin socket outlet 15/20 Amps on independent board with 4 Sqmm cable FRLS copper conductor multistranded including 4 sqmm PVC insulated and unsheathed FRLS copper conductor cable as earth continuity wire all as specified and directed by Engr-in-Charge.
Supply & Fixing modular switch 1 way 6A, 1 module, 230 volts.
Supply & Fixing modular switch one way 16 Amps, 1 module, 230 volts.
Supply & Fixing modular socket 6 Amps-2/3 pin combined, 2 module.
Supply & Fixing modular socket 6A/16A-2/3 pin combined, 2 module.
Supply and fix ceiling rose surfaces bakelite 65 x 50 mm three terminals including supply and fix PVC plate or square blocks.
Supply & Fixing stepped type 2 module modular electronic fan regulator flush type including removal of old one.
Supply & fixing MCB, 6 to 32 Amps, single pole, C Series, 10 KA, 240 volts.
Supply and fixing MCB 32 Amps TPN, C Series, 10 KA, 415 volts.
Supply & Fixing MCB protected socket of 20 Amps with sheet metal enclosure including plug top of 25 Amps complete with one single pole 240V with 20 Amps MCB including disconnecting and removal of old one. Make : Havells Cat Part No. DHDMCSN0251020 or equivalent in Legrand/C&S/Anchor
Supply & Fixing sheet metal enclosure DB, 4 way, TPN, double door factory made powder coated including neutral and earth link connector flush fixed in wall complete including dismantling of old one complete all as specified and directed.
Supply and fixing LED tube light fitting surface and wall mounted batten with 20 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete made up of polycarbonate complete all as specified and directed.
Supply and fixing suspended LED tube light fitting with 40 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete including suspension system for hanging the tube light complete all as specified and directed.
Supply & Fixing submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLS copper conductor cable drawn in and including 25/32mm wide PVC conduit concealed with all accessories as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as directed by Engineer-in-Charge.
Supply and fixing Earth continuity conductor or main earthing lead of 16 sqmm PVC insulated copper conductor drawn in through concealed steel conduit/pipe and connecting from existing earthing to Distribution box complete.
Supply & fixing brushless direct current (BLDC) ceiling fan 1200mm sweep (ISI Marked), 230 volts, 26 Watt includung connection rod as per existing size of length of GI pipe medium grade including dismantling of old one and depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Orient/Havells/Bajaj
M/L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI earth strip 25x4mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation disintergrated hard rock filling earth of 15 mm thick and privision of earth pit provision of 20mm dia eith funel PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr-in-Charge.
Tara Construction
JINTECH
SACHIN CONSTRUCTIONS
M/S. M M S ENTERPRISES
M/S Kartik Enterprises
KIRAN TRADERS
CVs CONSTRUCTIONS
M/s Abhay Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .