Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
26 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA
PROVN OF 01 X 6 MEN GUARD ROOM,FOL DUMPSTORE, LADY OFFICER TOILET,RAIN SHED FOR PATHWAY AND SPECIAL REPAIR TO BUILDING NO TS 693 AT VARIOUS LOCATION UNDER GE NAGROTA.
2022_MES_550794_2
GEN-07/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NAGROTA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹94,000
Yes
31 Oct 2022
7 Oct 2022
28 Oct 2022
7 Oct 2022
26 Oct 2022
13 Oct 2022
Amount
BUILDING WORK NOTE:-THE WORKS LIES IN DIFFERENT LOCATIONS CONTRACTOR SHALL QUOTE THEIR RATES ACCORDINGLY
Excavating in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for foundation etc. and getting out in Sof t/ loose soil
M & L PCC 1:4:8 type D-2 (Using 40 mm grade aggregate) in foundation, filling and mass concrete
Use and waste of formwork for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces
Use and waste of formwork for sides of columns posts, struts,piers square or rectangular or polygonal rough finished surface of concrete all as specified.
M&L for form work to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, shelves,incluiding sub ports, overhangs, etc. also splays between floors and beams etc. for fair finished complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engineer-in-Charge.
M&L Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in foundation, plinth beams,footings etc,.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in columns.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in floor or roof beams
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttressescomplete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in 1:6 all as specified and as directed by Engineer-in-charge.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified.
M & L TMT bar 10mm dia and over cut to length bend to shape required indd cranking bending spirally for column, hooking ends & binding with and incld mild steel wire (annealed) not less than 0.90mm dia or securing with chips as directed
M & L TMT bar but 5mm dia and over upto and including 10mm dia in stirrups, spacers and bindersincluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip as directed
M & L for mild steel work as in grills/guard bars,Hand rail,screw bolt etc. with ends of bars shouldered or revited conforming to Fe.290.Gde-E-165 complete all as specified.
M&L rendering 15 mm thick on external faces brick /concrete surfaces other than fair faces of wall in cement mortar 1:4 rendering is to be finished even and smooth (without using extra lime or cement all as specified and directed.
M & L preparation of new decorated surfaces of external walls and applying two coat of cement base paint over a coat of primer complete as specified and directed
M&L for rendering 15 mm thick in CM 1:6 on other than fair face of brick work/ stone wall surfaces finished even and smooth with out using extra cement all as specified.
Preparing new plastered surfaces of wall and applying two coats of oil bound distemper over 1 to 2 mm thick wall care putty over a coat of primer on walls etc all as specified .
M&L for Rendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement including two coat of white wash on ceiling including preparation of surface .
M&L for glazed ceremic tiles 350x250x7 mm/450x300x7mm thick, as in dado, vertical surfaces set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 10 mm thick rendering in CM (1:4) complete all as specfied and directed.
M&L for 25mm thick PCC type BO 1:2:4 (12.5mm graded aggregate in flooring finishing rough to recieveing Top layer for flooring complete all as specified and directed.
Machine cut kota stone flooring 18-20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) (Each stone not less than 55 cms x 55 cms) complete all as pecified and directed.
Machine cut kota stone slab 18-20mm thick in skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) over 15 mm thick rendering in CM ( 1:4) including taking out of existing dado.
S & F pressed steel frames made of size 1.25mm thick MS steel for door with one or more rebates incl lugs, hold fast, lock strike plate etc complete of size 105 x 60mm including one coat of red oxide primer and PCC 1:3:6 as in back fill to chowkats all as spfd.
M&L 35 mm thick 2nd class hard wood, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), complete all as speciied.
S&F 35mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive gauge etc without sash bar but with lock rail fitted with cut and mitered beads.
Solid PVC Door Frames of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheetto be fitted in the MS frame welded/sealed to the styles and rails with suitablePVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawings.
S & F Box type Steel ventilators top hung double shutters (inside for wiremesh & out side for glass), incl guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing.
S & F Box type Steel windows side hung double shutters (inside for wiremesh & out side for glass), incl guard10mm square bar ,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing.Steel window shall be conforming to relevant IS complete all as shown on drawing No- CEUZ/TD/1302/09 sheet No- 1/3 to 3/3 directed by Engr-in-Charge.
S&F in repair Galvanised mild wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5 m above the starting point
Returing filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick.
M&L for PCC (1:3:6) 75 mm thick Type C-2, using 40mm graded stone aggregate as in floors in bed to recive tiles /path tiles etc.
M&L for colored non skid ceramic tiles 7to 8 mm thick, area of each tile exc 0.11 sqm but n exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in colored cement over and incl 15 mm thick screed bed or bedding layers of cement mortar 1:6 to match Shade, pattern, laying etc of tiles complete all as specified and directed.
Painting two coats with synthetic enamelled paint over one coat of pink primer on new wooden urfaces of any description exceeding 10cm width/girth including preparation of surfaces
M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing with sand paper to make surface even and smooth complete all as specified
M&L for 20mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors including taking down complete all as specified and dirceted.
M&L for 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors including taking down complete all as specified.
S&F Rotational moulded polyethene water storage tank 500 ltr capacity hoisted and fixed in position including dismantling of existing tank and including PVC float valve 20 mm bore . Make:-vectus,sintex
Cutting chases,pinning for tubing and making good to facing where required and pointing in cement mortar 1;3 ,cutting exc 10cm but n.exc 20cm girth all as specified and as directed by Engineer-in -Charge.
S&F 3 mm thick sheet glass ordinary quality glazing with steel pins,oil putty to steel windows and, beads nails etc to wooden surfaces as in square exc 0.50 sqm in each pane, all as specified. Make:Saint Gobain
S&F in repair angle valve with wall flange , cast copper alloy, chromium plated fency type screwed for 15 mm iron pipe, complete all as specified. Make:- PARRYWARE/JAQUAR
S&F in repair CP Bib taps,long body, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified complete all as specified. Make:- PARRYWARE/JAQUAR
S & F in repair 15 mm bore pillar taps fancy type cast copper alloy chrominium plated fancy typewith capstan heads, chromium plated, screwed down high pressure with or without lettered "Hot or Cold" with long screwed shanks and fly nuts screwed for iron pipe.
S&F in repair Vitreous china wash down water closet white colour, Size(570x390x400) with 'S' trap, closed pattern with flat bottom, complete all as directed. Make:- PARRYWARE/JAQUAR
S&F for 110mm bore Cast Iron (SWR) 'P' or 'S' trap, including fixed with solvent cement complete all as specified and directed.
S&F in repair flush Cistern with Drainage L-Bend Pipe with Gasket & Installation Kit (Suitable for EWC), complete all as specified. Make:- PARRYWARE/JAQUAR
S&F in repair 450mm Long Braided Hose with Two 15mm Nuts & Rubber Washers (Both Side) Without Nipple (Suitable for Geysers) complete all as specified. Make :- Jaquar, Cat No- ALD-CHR-805B or equivalent in kohler/ Artize.
S&F UPVC (SWR) Type-B pipes single socketed, 110 mm dia, in any length with rubber ring joints, laid in trenches or on wall complete all as specified. Make:- Astral, Supreme, Finolex.
S&F in repair Wall Hung Basin with Fixing Accessories Set, Size : 510 x 400mm, including cuppling and pvc waste pipe complete all as specifiedMake:- PARRYWARE/JAQUAR
S & F butt hinges of mild steel cold rolled medium weight of size 100mm as specified.
S&F Aluminium anodised, barrel tower bolts size 200 mm of extruded section and fixed complete all as specified. (ISI Marked)
S&F Aluminium handles, cast type, anodised Size-150mm, anodised section and fixed complete all as specified. (ISI Marked)
S&F Aluminium alloy, anodised, sliding door bolt Size- 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed cpmplete all as specified.
M & L for PCC 1:3:6 C-1 (using 20mm graded crushed stone aggregate) as in plinth protection ( 50mm thick ) finished even and fair all as specified.
Surface excavation no t exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil.
S & F in repair mild steel helical/ordinary rat tail rod pattern door spring 300mm including roller and roller plate complete fixed with welding all as specified. Make:- ( ISI Marked)
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) with average thickness 50 mm laid in two layers of 25 mm thickness each with wire netting of 0.60 mm dia and size of mesh 12 mm x 12 mm laid between the two layers finished even and smoothes in roof padding all as specified and as directed Note:- The wire mesh shall be measured and paid separately under the respective item below.
Supply only 25 mm size, wire netting of galvanized iron chicken mesh, 0.71 mm dia complete all as specified and directed.
Material and labour APP based polymeric membrane minimum weighing 3.5 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified laid over a coat of bituminous primer @ 0.40 ltr /Sqm & finished with applying bitumen grade 85/25 coat @ 1.2 Kg /Sqm. APP membrane shall be laid by torching with 75mm overlap in longitudinal direction and 100mm overlap in transverse direction all as directed and finished with applying one coat of aluminium paint as directed by Engineer-in-Charge and laid as per paticular specification of CA
Hard core of broken stone or boulder of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface.
20mm thick screed or screed bedding in cement mortar 1:4 as a sub base to chequred tile
Chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick , set, jointed and pointed in neat slurry in with grey cement and pigmentsincluding removing old tiles,padding if observed on roof , all as specified.
PCC 1:2:4 type B-1 as in surface channel all as spd and directed
PCC 1:2:4 type B-1 as in coping all as spd and directed
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms ,moulds,mitred/stopped ends etc
Material and labour Cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) in foundation filling and mass concrete complete all as specified.
Precast cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover all as specifed including form work complete all as specified.
S&F 150 mm diameter Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified.
S&F On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc complete for 30 user conventional type all as specified.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80m dia X 3.0m effective depth complete all as specified.
S&F Brass CP basin mixer fancy type for mixing hot & cold water screwed down for iron pipe and fixed of 15mm bore dia of pipe
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm.
S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for ironpipe and fixed. (Minimum weight 210 gms) complete screwed for iron pipe or brass ferrule of size 20 mm bore.
S&F for brass chromium plated jet spray for pedestal pattern seat with flexible tube of length 1.5 mtr complete all as specified and directed
S&F health faucet/ hand jet/ hand shower brass chromium plated with flexible tube of length 1.5 mtr length complete all as specified and directed
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls
S&F 110 PVC (SWR) bends
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
S&F PVC (SWR) floor trap with grating including jointing to waste pipe in solvent for 75mm bore including CP grating cover with or without hole complete
S&F PVC (SWR) 'S’ trap of 110 mm bore
S&F LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 10 users
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2m dia X 1.5m effective depth
RCC NP2 200 mm diameter Pipes laid on 150 mm thick bed of PCC 1:4:8 with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional.
Material and labour for Factory made mechine pressed precast concrete interlocking paver block any shape and size top layer with grey cement and pigment of thickness 80mm in different colour and pattern ,laid over 25mm thick dry sand and joint filled with dry sand complete all as specified and as directed by Engineer-in-Charge.
Excavation for post holes (or in similar hole ) each n.exc 0.50 Cum including dismantling PCC including disposal of surplus n.exc 50m all as specifed and directed by Engineer -in- Charge.
M&L for PCC 1:3:6 type C-2 (20mm graded aggts) in foundation filling and mass concrete all as specified and directed
M&L for posts and struts in fencing of angle, tee including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed etc complete all as specifed
Fixing chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete.
Supply only Chain link fencing with or without line wires,any type and mesh size and any type of standards and dia of wire ( as directed by Engineer-in-charge) fixed with rails, staining bolts etc ( rails, staining bolts will be measured in seperate Item)
S & F in repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc.,(each line wire to be measured separatley) complete all as specified. as directed.
Ornamental and intricated design frame work in steel gate complete drilled welding for fixing of steel sheeting or other covering, hooks hinges or steel hanging doors fittings also fastening and fixing complete as directly in Eng-in-Charge.
S&F 10mm thick Poly carbonated sheet having any colour and jointing stiruups fixed as per specification and drawing.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm eachand n exc 4 sqm and removing from site.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles.
Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided.
Taking down wooden roof trusses above 4mtr & upto 8mtr, coupled rafters all as specified and directed
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc.
S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
Curtain rod 25mm dia aluminum brass polished with ends bulbs rings of required size including bracket complete all as directed.
Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over screed bed or beddding layer of CM 1:4, 15 mm thick complete all as specified and directed.
Non-skid coloured tiles 400x400x7mm thick as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over 25mm thick PCC (1:2:4) type B1, over screed bed or beddding layer of CM 1:4, 15 mm thick including including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) , removing serviceable tile to store and rubbish off the premises complete all as specified.
Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 15mm cement rendering in cement mortar 1:4, including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) , removing serviceable tile to store and rubbish off the premises complete all as specified.
PCC 1:3:6 C-1 (using 20mm graded crushed stone aggregate) as in plinth protection ( 75mm thick ) finished even and fair all as specified.
Providing number plate of size 450 x 300x20mm in CM 1:4 and writing building No of height 8 to 10cms with luminous paint through grooves of size 12 x 12mm ( Base: Black, grooves : orange)
Rotational moulded polyethene water storage tank 500 ltr capacity hoisted and fixed in position including PVC float valve 20 mm bore and including dismantling of existing water storage tank complete.
S&F gratting doom 100mm dia of PTMT
S&F gratting doom 125mm dia with waste hole of PTMT
Shower rose brass chrominium plated 125mm size complete all as specified and directed.
Soap dish PTMT fixed with including chromium plated brass screws and wooden/plastic cleats ( Minimum weight 105gm).
Towel rail 600mm long of PTMT fixed with including chromium plated brass screws and wooden/plastic cleats ( Minimum weight 190gm).
S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white including fixing bolt and flush pipe and PVC seat cover with necessary connection complete all as specified.
Supply and fix 10 ltr capacity PVC valveless, syphonic action type flushing cistern low level white with inlet, ball valve, float and handle including connection to pipe complete all as specified.
Dismantling cast-iron/PVC pipes including fittings taking out of trenches or walls as required dia of pipe upto 100mm.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 110mm bore.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75mm bore.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 75mm bore.
S&F PVC (SWR) Bends any radius for 110mm bore.
S&F PVC (SWR) Bends any radius for 75mm bore with oval access door.
S&F PVC (SWR) floor trap with grating including jointing to waste pipe in solvent for 75mm bore including CP grating cover with or without hole complete.
S&F GI T Grid system in ceiling 600 x 600 mm module which includes providing and fixing wall angle along the perimeter of the room with nylon sleeves and wooden screws at 300 mm center to center. Suspending the main tee of size from the soffit, soffit cleat, rawl plugs and wire rod and levelling spring clip at 1200 mm center to center cross tee, interlocked into the pre-cuts in the main tees at 600 mm center to center in direction perpendicular to the main tee to make a grid of 600 x 1200 mm. 600mm cross tees are interlocked in the pre cut slots in the 1200 mm tees at 1200 mm center to center in direction parallel to the main tee. Cross tees having length more than 600 mm are to be supported independently. 4.5 mm thick E board with square edge of size 595 x 595 mm be placed in the grid of 600mm x 600 mm. Size of grid is specified by manufacturers
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc
Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custedy for taking credit all as specified and as directed by Engr-in-Charge
Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt, oiling & greasing and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete, all as specified and directed by Engr-In-Charge.
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) PVC casing caping in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly complete all as specified for the following;- (a) One light point controlled by one switch 5 Amp.
(b) One ceiling fan/exhaust fan point controlled by one switch 5Amp
(c) One socket out let 5Amp controlled by one switch on same board.
(d) One socket out let 5 Amp controlled by one switch on independent board.
All as per item No 138 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board.
All as per item No 138 here in before but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4 sqmm cable as earth continuity conductor for controlled by two pin and earth plug and socket complete with one single pole MCB 20 amp 240V
S&F switch piano flush type 5 Amps single pole one way complete,
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete.
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type complete.
S&F of ceiling rose surface type 65mm x 50mm 2 to 3 terminal complete .
Supply and fixing swing type wall mounting fan 450 mm sweep single phase AC 230/240V complete for wall mounting incl grouting, holding down bolts, nuts, and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to fan. Make per model No Airboll Hi-speed of Havells and equivalent in Bajaj / CG.
Supply & fixing heavey duty Exhaust fan 450 mm sweep single phase AC 230/240V complete with louvers Make : Havells/ Bajaj/CG
Supply & fixing Ceiling fan 1200 mm sweep 5 star rated single phase AC 230/240V complete as per model No Fusion of Havells and equivalent in Bajaj / CG
S&F Single pole & neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp 240V
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete.
S&F MCB DP 63 Amps 10 KA 230 volts "C" series complete
S&F MCB single pole 6 to 30 Amps 10 KA 230 volts "C" series complete
M&L Integrel sleek extruded batten aluminium /CRCA channel fitting with LED 18 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V 50 Hz.
S&F white powder coated CRCA housing with LEDs 36W, 230 V, 50 Hz Surface mounting LED 2 feet x 2 feet luminaries, Sweamless front frame with flat white hight transmission acrylic cover complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size.
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link TPN 4 way suitable for MCCBas incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar including 125 A MCCB as incomer 16 KA complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all as directed by Engr-in-Charge at site incl taking out of exsing UNSV DB with MCBs.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
Supply and fixing wall mounted busbar chamber 415V, 3 Phase 4 wire, 50Hz AC supply system fabricated from stainless steel with 3mm thick for outer cell TPN aluminium busbar of cap 100 Amp 4 pole 8 ways complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sq mm as earth continuity conductor connected to commen earth and earth dolly complete incl taking out existing UNSV service connections.
Supply and install stationary water heater (Geyser) vertical storage type of 25 Ltr capacity electric driven closed vented 5 star marked suitable for operation for single phase 240 volts, inner container made out of stainless steel, 1500 watt, pressure rating 60 N/Sqmm, class-1, 5 star with all necessary fittings, cutting out holes in existing cement concrete/bricks walls built in cement mortar, supply, fixing, grouting new purpose make mild steel bolts with screwed end 8mm dia and 100mm long alongwith one washer and one Hexagonal nut at screwed end for fixing the geyser all as specified and directed including making good the disturbed surface to match with the existing surface and finishes complete as per model No Senzo of Havells and equivalent in Bajaj / CG.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete.
S&F building security light luminaries eenergy saving and envirnment friendly long life LED light of 25W made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistanve of IK07, including GI bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle 120 degree, fixed with and including two nos 25x4 mm size flat mild steel clamp made to shape and suitable size nuts, bolts and washers etc including taking down of existing light fitting and complete ,all as specified and directed.
S&F baton integrated LED channel of 5W, 230V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, Power Factor not less then 0.9 as per Cat No BCLSB 05 WH of Bajaj or or equivalent in in approved make
M&L LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz .
S&F for lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. Anchor (Penta) or equivalent model of Cona/Havells/HPL
S&F for LED bulb 7 watt complete all as specified and directed. Make Bajaj /Havells
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete.
Supply and laying or fixing of cable 1100 volts grade cable PVC insulated aluminium conductor un-armoured of 16 Sqmm 2 core flat or circular, served with inner sheathing of pace tape and overall PVC sheathed in service connection suspended by insulated hangers not more than one Mtr apart including 4 mm dia suspension GI wire, complete all as specified and as directed by Engr-in-Charge.
Supply and laying in trenches/on piller/on wall GI water tubing 20 mm bore dia medium grade ISI marked with all fitting (such as tee,elbow,socket,union,short, pieces) including testing etc. complete all as specified and directed.Make: Jindal/suraya/(Note:Exacavation and earth work shall be measured and paid separately)
S & F Gunmetal globe (Class 2) or gate valves (brass insert),with iron wheel head screwed both ends for iron pipe size 50 mm dia all as specified and directed by engr -in charge.
S & F Gunmetal globe (Class 2) or gate valves (brass insert),with iron wheel head screwed both ends for iron pipe size 20 mm dia all as specified and directed by engr -in charge.
M&L for brick masonary valve pit of size 60x60x90 cm (internal dimensions of chamber) including 23cmthick wall built in CM 1:6, 15mm thick plain cement plaster internally in CM 1:4 and flush pointing externally as the work proceeds, PCC 1:5:10 type E2 in foundation 156x156cm size 40mm thick PCC 1:2:4 type B-1 in floor, 50mm thick PCC 1:2:4 as coping over brick work, MS sheet cover of size 112x112cmx3 mm thick fixed to angle frame made out of 40x40x3mm angle iron, MS handle to sheet cover, MS hinges welded to frame and sheet cover, painted with two coats of synthetic black paint over a coat of red of red oxide primer on steel work , two coats of white wash on plaster work including excavation and earth work in any type of soil complete all asspecified and directed.internal and externally on steel work incl excavation and earth work all as spd and directed.
Cutting of existing pipe laid 80 mm dia for inserting Tees for new connection of 50 mm dia all as specified and directed by Engr-in - charge
U K Engineering Works
ASHWANI KUMAR KHAJURIA AND SONS
Bidder Name
U K Engineering Works
ASHWANI KUMAR KHAJURIA AND SONS
Karmnaya Construction
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .