The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less ; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfillment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference. (Ref:- GM/Engg. letter no. CE/G/Arb & Cont. Mgt./Tender Circular/Pt. I/317 dtd. 11.03.2025)
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Similar nature of work means- "Any work of supply, installation, testing and commissioning of Railnet Network or any networking system using switches / Router/Wi-Fi/ IP based CCTV in govt. Sector/ Semi Govt. / Govt. undertaking / PSU - Indoor/Outdoor"
Tenderer should submit relevant document regarding completion and execution of any of the work mentioned in para 1.1 above for fulfilling Technical Eligibility Criteria of Similar Nature of Work.
29 conditions · 4 needing a document upload
GST Registration details should be attached
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also,as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding.Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under GST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/ UTGST/ SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority.
In case the successful tenderer is not liable to be registered under GST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
JPO to prevent the damages of underground utilities :- The contractor shall conform to JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures (Ref:- RB Letter No. 2021/Tele/5(2)/3-Part (1) (3425647) dtd. 12.06.2023 ). The biddder is requested to go through the same (copy attached) before quoting their offer. The stipulations of the JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures are to be strictly followed till the currency of the contract.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfillment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference. (Ref:- GM/Engg. letter no. CE/G/Arb & Cont. Mgt./Tender Circular/Pt. I/317 dtd. 11.03.2025)
S&T Portion of work for (1) Station development work at Soro under Amrit Bharat Station Scheme of Kharagpur Division (2) Railnet connectivity for construction of new 70 beds R/Room instead of 100 bedded Running Room at NMP.
ST-OT-ABBS-SORO-Stn
ST-OT-ABBS-SORO-Stn
Open
Works - General
9 Months
Paschim Medinipur, West Bengal
₹0
₹1.2 L
5 Jun 2026
12 May 2026
22 May 2026
90 items across 2 schedules · ₹53,54,278.47 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Depth 1.0 meter, Width 0.3 meter. | Kilometre | 1.50 | 59,091 | 88,636.5 |
| 2 | Excavation of trenches including clearing of roots of trees etc.in hard/rocky soil by chiselling up to a depth of 0.5 meter to 0.8 meter and width 0.3 meter at the bottom, supply & placing split RCC pipes with collar (for jointing pipes) of 100 mm nominal diameter to Spec. No. IS: 10262-1982 or latest and IS-456-2000 as per SEM Drawing No. 15-D3 (Sheet-2) on sieved soil of 30mm over cable and concreting(1:2:3) throughout the length upto a layer of 75mm approximately, then back filling the trench by digging and carrying earth from a distance of maximum 30 meters and then ramming of soil after cable laying. This includes Split RCC Pipes with collar and all the materials for concreting are to be supplied by the contractor. Materials inspection shall be done by Railway Site Engineer. | Metre | 330.00 | 490 | 1,61,700 |
| 3 | Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 mtr. For Track/ pucca road/platform crossing/ level crossing as per SEM Drawing No.15-D5 including supply, transportation and laying of DWC pipes (full) with collar(for jointing pipes) Inner diameter/Outer diameter:103mm/120mm to Specification No.14830(Part-2):2001 as per SEM Drawing No. 15-D4,in trench and drawing of cable through DWC pipes with collar(for jointing pipes) including back filling and ramming after cable laying as specified in Tech. Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables (Cable laying charges is included). This includes repairing and plastering of platform/pucca road after cable laying. Material inspection shall be done by Railway Site Engineer. | Metre | 90.00 | 576 | 51,840 |
| 4 | Cutting and smoothening of inside surface of sizes 80 mm deep and 170 mm width for single/multiple cable chase in concrete or hard rocks or platform or cemented floor. This work includes laying and covering of cable laid in the chase with standard sizes Second class/Fly Ash brick placed and embedded longitudinally and plastered on the top of the bricks and curing 72 hrs. as per Drawing No. Con/SK/T/1 for the following. (i) Single cable/Multiple cable (upto 3) (see Note 4 of Drawing no. Con/SK/T/1). Note: Bricks, sand and cement shall be supplied by the contractor at site and to be inspected by Railway Site Engineer before placing in the chase. | Metre | 300.00 | 213 | 63,900 |
| 5 | Supply, transportation and fixing of Galvanised Iron Pipe (make: TATA/Jindal or better) with threaded collars (for jointing pipe) of 80 mm nominal bore Specification No. IS: 1239, thickness 3.2 mm medium grade, on bridges, culverts, drain or at places as per instruction of the site Engineer including supply and transportation of materials required for fixing the pipe as per SEM Drawing No.15- D7 including drawing of cables inside the pipe with masonry work at bridge entry and exit of the culvert and curing for 72 hours and pipes are to be clamped at max. 2 meter apart with drilling of holes on the pipe at 10 cm apart for the following S&T Cables. The Galvanized iron pipes and other materials required for fixing to be supplied by the contractor. Material inspection shall be done by Railway Site Engineer before use. This also includes dismantling of released GI Pipe/Trough and released material should be returned at concerned store. | Metre | 78.00 | 848 | 66,144 |
| 6 | Supply of HDPE pipe with OD/ID 40mm/33mm, Thickness 4mm with suitable couplers, plugs, end caps, spacer, T band etc. as per Specification No. RDSO/SPN/TC/45/2013 Rev-2.0 or latest. | Kilometre | 4.00 | 47,042 | 1,88,168 |
| 7 | Transportation of cables in rolls with or without wooden drums (S&T Cables) from concerned store to the site of works. | Drum-Km | 1.00 | 1,938 | 1,938 |
| 8 | Laying of S&T Cables (Signal/Quad/Power) in the excavated trench to Drawing No. CON/SK/T/5. Transportation and supply of 'U' clamps, anchoring of cable at every 10 mtrs interval with 'U' clamp on trench to Drawing No. CSTE/CON /CABLES/81. Transportation, supply and placing of cable demarcating lead belt to Drawing No. CON/SK/T/6 punched at an interval of 30 mtrs. and wrapped round each cable throughout the cable route and also at every track/Road/ platform crossing as above specified in Technical Circular No. 2/1988 & 01/2010 issued by CSTE/SER and guarding the cables collecting empty drums with left over cable and return to the stores of stock holder. | Kilometre | 1.00 | 16,845 | 16,845 |
| 9 | Transportation including loading/ unloading of Optical Fibre Cable along with HDPE pipe from the stores of SSE/Store or from any store of SE Railway to the site with care and laying of OFC as per procedure and returning empty cable drums with or without left over cable to the stores of SSE/Store. It includes supply and placing of warning & Detection tape orange colour of 100 mm. Wide printed in black as "CAUTION OFC CABLE" at every 1 meter interval (Minimum) and laid in the trench in station section and as directed by the Representative of Railway. | Kilometre | 3.00 | 28,910 | 86,730 |
| 10 | Execution of Full Apparatus Case with pit, concrete foundation, surrounding earth work, erection, installation as per Drawing No. Con/SK/T/8 and wiring as per SEM Drawing No.19-D8 or as per direction of site engineer. Fixing of Hylam sheet strip of size approx. 925mmx100mmx3mm (including supply) with hole on both side for writing & terminal description, terminals, fuse blocks, relay and other accessories for signal/track circuit, termination of cable with number embossed ferrules, bunching of cables with PVC tape, earthing of cable armour as required. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anticorrosive paint and subsequent two coats of Aluminium paint outside and red oxide inside and lettering etc. This includes transportation of 25 mm/12mm Hylam sheet for shelf or as required and also includes minor modification in L/Boxes as per site requirement .The contractor shall supply of 4 no. of foundation bolts 22 mm dia. x 450 mm long with 2 flat spring washers, one nut is to be used for each set, sand for filling up cable pit inside the apparatus case and bolts, nuts, screws, MS Clamps for fixing equipment/cable. Note: - Part payment shall be released after completion of- (i) Foundation- 40%, (ii) Erection - 10%, (iii) Wiring, earthing, testing - 20%, (iv) Painting, writings - 10%, (v) Plastering, sand filling & etc. - 10%, (vi) Commissioning - 10%. | Numbers | 2.00 | 7,613 | 15,226 |
| 11 | Supply of 6 Core Armoured Mono mode OFC cable as per Specification No. IRS:TC 55- 2006 Rev.1 or latest. | Kilometre | 6.00 | 18,821 | 1,12,926 |
| 12 | Supply of PVC insulated Single core Multi- strands copper conductor 3 Core 2.5 sq.mm power cable with ISI marked to IS:694 latest. | Metre | 2500.00 | 86 | 2,15,000 |
| 13 | Supply of basic material to construct unit Maintenance Free Earth for Single Earth consisting as per Spec. No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/ RDSO/E&B/002. (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm dia. min. with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound of RDSO approved brand supplied in sealed bags of min 30-35 Kg.- 1 Nos. (c ) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1no.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1no.(e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1no. It includes (i)Supply of 35 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.- 10 m. (ii)Supply of 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 m. (iii)Supply of 10 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipments to SEEB10 m. As per RDSO spec. for Desire Earth Resistance less than 1(one) Ohms. | Set | 3.00 | 14,748 | 44,244 |
| 14 | Installation of Single Maintenance Free Earth pit as per RDSO Drawing No. SDO / RDSO/ E&B/001 which includes the following:-a) Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia. to the depth of approx. 3 meter. b) Insertion of 3.0 meter electrode and penetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400mmX400mmX50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint. | Set | 3.00 | 5,076 | 15,228 |
| 15 | Supply of Class B & C Surge protection Device (SPD) - Type I & II with Visual Indication and Potential free contact to remote monitoring as per Specification No. RDSO/SPN/165/2012 Ver 3.0 or latest and IEC standard 61643 for Single line 230V AC application with handling Lightning surges of 10/350 microseconds and Switching surges of 8/20 microseconds .One Set consists of 3 nos. of SPD (2 No. of B Class (L-N, N-E) and one no. of C Class (L-N) all enclosed in a Box with KEMA or VDE certified as per latest IEC 61643-11-2011 Standard. Class B &C Surge protection device required with Three modules only. | Set | 2.00 | 5,000 | 10,000 |
| 16 | Supply of cable fault locator complete with all necessary accessories including rechargeable battery pack and charger Liquid Crystal Display (LCD) with back light. Low Insulation Faults Mode Max. Low Insulation Faults Mode Max. Range: 20 Km etc. | Numbers | 1.00 | 1,32,915 | 1,32,915 |
| 17 | Supply of Insulation tester 100V, 100 MOHMS with lead cables, Analog Display, metal body hand driven. | Numbers | 2.00 | 2,513 | 5,026 |
| 18 | Supply of Earth Tester (Analog 4 terminal) Range 0-10/0- 100 OHMS Double with accessories. | Numbers | 1.00 | 4,042 | 4,042 |
| 19 | Supply of LAN tester UTP cable tester similar to make of Voltec/D-Link. | Numbers | 4.00 | 531 | 2,124 |
| 20 | Supply of KRONE TOOL for inserting wire into insulationdisplacement connectors similar to krone make. | Numbers | 5.00 | 340 | 1,700 |
| 21 | Supply of managed SDH (STM-1 Add/Drop MUX and upgradeable to STM-4) fully wired for 2 X 63 MB and equipped for 21E1s and with STM1 (L1.1) aggregate interface including power supply, order wire, Ethernet card, sub rack, inbuilt DDF, installation material and all other accessories, manuals etc. as per TEC. Specification GR SDH 04/02, March 02 or with latest amendment. The contractor will supply all other accessories as mentioned in the above said TEC Specifications and system will have provision of different redundancy cards as per the TEC Specifications. Note: It shall be possible to increase capacity from 21E1 to 63 E1s by adding / inserting tributary cards. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH equipment with all cards to the 48V Bus including supply of wires and connectors. Termination of all E1s on DDF taking PVC cable over runway or a wall. At the terminal station, one port may be disabled if required as per instructions given by site engineer in-charge. | Numbers | 2.00 | 1,67,855 | 3,35,710 |
| 22 | Installation, wiring, testing & commissioning of managed SDH (STM-1 Add/Drop MUX and upgradable to STM-4) fully wired for 2 X 63 MB and equipped for 21 E1s and a Virtual Container (VC)-12 with STM-1(L1.1) aggregate interface including power supply, order wire, Ethernet card, sub rack, inbuilt DDF, installation material and all other accessories, manuals etc. as per TEC. Specification GR SDH 04/02, March 02 or with latest amendment. | Set | 2.00 | 19,386 | 38,772 |
| 23 | Supply of 2 MB programmable Primary Digital Drop/Insert multiplexer with conference facility As per Specification No. IRS: TC-68/2012 Amd.1 or latest wired for 30 Circuits complete with power supply, Control and Basis/Common cards (i.e. PSU- 02TME-01,LPC-01) Remote control supervision facility and all other accessories etc. The mux shall equipped with fallowing interface cards A) 2W/4W E&M interface card (4ckts per card)-04 nos. B) FXO Exchange loop interface card (4CKTS per card)-2 nos. C) FXS Subscriber interface card(4CKTS per card)-02 nos. | Numbers | 2.00 | 1,26,312 | 2,52,624 |
| 24 | Installation, wiring of all 30 channels up to krone modules, testing and commissioning of 2 Mb Programmable Primary Digital drop insert multiplexer as per RDSO Specs. No. - IRS/TC/ 68/2012 Rev.0 with Amendment No.1 or latest. It includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and commissioning of the system. | Set | 2.00 | 12,631 | 25,262 |
| 25 | Supply of Thermo shrink jointing (TSF) kits for jointing underground Quad cable 0.9mm diameter conductor for straight through joint, condenser joints, Y-(Derivation) joint, Loading Coil Joint, Transformer Joint as per Specification No. IRS - TC - 77 / 2012 Rev.3 with Amd. 3.0 or latest. | Numbers | 6.00 | 2,833 | 16,998 |
| 26 | Execution of Straight joint on Quad cable/ jelly filled Telecom cable using Thermo- shrink/Universal jointing kit (RTSF). This includes excavation of cable joint pit of size 1.2m x 1.2m x 1.0m for jointing of cables, back filling and ramming after jointing. | Numbers | 8.00 | 1,196 | 9,568 |
| 27 | Supply of Fibre Distribution Management system (FDMS)/LIU for 12 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec. GR/FDM/01/02 April'2007 or latest. This include supply of installation accessories as per technical specification. | Numbers | 2.00 | 2,168 | 4,336 |
| 28 | Installation and commissioning of Fibre Distribution Management system (FDMS) for 12 Fiber complete withall accessories with patch cord & pigtail as per TEC Spec. with latest amendment. This include supply of installation accessories as per technical specification. | Numbers | 2.00 | 1,736 | 3,472 |
| 29 | Supply of Fibre Distribution Management system (FDMS)/LIU for 24 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec. GR/FDM/01/02 April'2007 or latest. This include supply of installation accessories as per technical specification. | Numbers | 3.00 | 3,033 | 9,099 |
| 30 | Installation and commissioning of Fibre Distribution Management system (FDMS) for 24 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec. with latest amendment. This include supply of installation accessories as per technical specification. | Numbers | 3.00 | 3,342 | 10,026 |
| 31 | Supply, transportation and installation of joint enclosure for 6/12 fibres optical fibre cable complete with all accessories (sealing with mechanical clamp facility) for splicing of Optical Fibre cable. | Numbers | 21.00 | 1,250 | 26,250 |
| 32 | Supply of 24 Fiber OFC Joint Closure as per Specification No. RDSO/SPN/TC/68/ 2014 Rev 1.0 or latest complete with all accessories (sealing with mechanical clamp facility). | Numbers | 6.00 | 1,555 | 9,330 |
| 33 | Splicing of Optical Fiber Core and routing in joint closure/FDMS as per instruction of site Engineer. | CORE | 246.00 | 127 | 31,242 |
| 34 | Supply, transportation and installation of RCC joint chamber with two piece top cover and bottom cover with holes for drainage and cable entry, as per Drawing No. RDSO/TCDO/COP-21(a). This includes trenching for jointing pit, back filling and ramming of the pit after placing the joint closure and cable loop in the chamber including dry sand upto 600mm height without causing any damage to same and consolidation of soil as well as disposal of excess soil. | Numbers | 4.00 | 4,004 | 16,016 |
| 35 | Supply of 20 Pair CT box made of 16 SWG CRC sheet with disconnection and reconnection (Wago type). The CT Box should be grey colour powder coated with terminal, washer, nut & bolt should be of brass .There shall also be locking arrangement. | Numbers | 14.00 | 2,995 | 41,930 |
| 36 | 20 pair C.T. Box | Numbers | 14.00 | 762 | 10,668 |
| 37 | Supply of covered 19" racks 42 U complete with all fitting for housing the subrack SDH ADMs & PD Mux fully wired including, Power supply distribution system, DDF, Internal wiring and other accessories, runway ladder etc. The components of the rack are specified below- (i) Rack size 2200 HX 600 WX 600 D (ii) Fixed side panels 42U X 600 D (iii) Front glass door plain 42U X 600D (iv) Rear MS door plain 42 U X 600W (v) Levelling screws-4 Nos. (vi) Compact Fan Module working with 48 V DC- 2 Nos. (vii) Earth connecting kit-1 No. (viii) Cable manager with cable loops-2 Nos. (ix) Krone mounting bracket-01 No (x) Caster with breaks-2Nos (xi) 20" length 1" width 5 mm thickness copper strip with 12 Nos. of holes including SS bolts & nuts for every hole to connect cables-2 Nos. (xii) 10A single pole DC MCB-2 Nos. (xiii) 6 A single pole DC MCB-2 Nos. | Numbers | 1.00 | 29,892 | 29,892 |
| 38 | Supply of 9U Rack with 19 inch standard dimension, wall mounting, front glass door with lock and two key, with rack fixing Multi point AC power strip, cable organiser with wall fixing screws. | Numbers | 10.00 | 5,121 | 51,210 |
| 39 | Supply of 24 port L-2 Non-PoE switch CISCO or similar with 2 SFP ports with 3 years warranty complying Specification No. RDSO/SPN/TC/83/2020 Rev.2.0. | Numbers | 1.00 | 22,954 | 22,954 |
| 40 | Supply of SC to SC Single Mode Simplex/Duplex Fibre Optic Patch Cable 5m length. | Numbers | 52.00 | 169 | 8,788 |
| 41 | Supply of High power 250 W PA Amplifier. Make: Ahuja or similar. | Numbers | 1.00 | 9,761 | 9,761 |
| 42 | Supply of High power 1000 W PA Amplifier. Make: Ahuja or similar. | Numbers | 1.00 | 37,687 | 37,687 |
| 43 | Supply of STP CAT-6 Cable (Shielded Twisted Pair) STP compliant with latest EIA/TIA-568-B2-1. | Metre | 2135.00 | 33 | 70,455 |
| 44 | Supply of RJ-45 CONNECTOR of reputed make such as Dlink or better. | Numbers | 100.00 | 4.51 | 451 |
| 45 | Supply of Push button telephone instrument single with caller id facility equivalent to Beetel M 53/ Binatone Concept 700/Panasonic KXTX 880MX. | Numbers | 10.00 | 745 | 7,450 |
| 46 | Supply of Telephone instrument single push button FCT telephone make VISION TEK 81G, SIMADO FX 11, AEGIS or similar. | Numbers | 2.00 | 2,601 | 5,202 |
| 47 | Cement Concrete of proportion 1:3:6 (Cement: Sand: Stone chips of 25mm nominal size) for miscellaneous items. It includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). Note: All materials required for foundation are to be supplied by the contractor. | cum | 6.00 | 3,036 | 18,216 |
| 48 | Supply of 1 inch (25mm) PVC casing capping in rectangular shape with separate Casing & Capping, double lock, heavy duty & ISI mark with IS:14927 or latest with minimum 1 mm thickness. | Metre | 400.00 | 29 | 11,600 |
| 49 | Supply of PVC conduit pipe rigid plain ended conduit size 1 inch (25 mm) IS:9537(part-3) and 9537 (Part-1) 1980 with latest amendment ISI marked with minimum 1.2 mm wall thickness & one socket at every 3 meter pipe. | Metre | 2000.00 | 23 | 46,000 |
| 50 | Transportation and Fixing of PVC Conduit pipe/channel/casing caping on wall or structure with drawal of Telecom/Power /Data cable with proper finishing. | Metre | 2400.00 | 13 | 31,200 |
| 51 | Supply of C series MCB 2 POLE 32 AMP with metal enclosure. Make Schneider, Legrand, L&T, Havells. | Numbers | 4.00 | 517 | 2,068 |
| Schedule total | ₹24,78,569.5 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRGCC April 2022
ATTACHMENT
BankMandateForm.pdf
ATTACHMENT
BankGuarantee-converted.pdf
ATTACHMENT
LCform.pdf
ATTACHMENT
EngagementofretiredRlyEmpCertificate.pdf
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
AnnexureVA.pdf
ATTACHMENT
SpecificationofIPbasedSIPNonExecutivePhone.pdf Specification SIP Phone
ATTACHMENT
DetailsofInspectionAuthority_1.pdf
ATTACHMENT
JPOCableCut19FEB2024.pdf
ATTACHMENT
RlyBoardsLetter2021Tele523part13425647.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
SpecificationofIPbasedSIPNonExecutivePhone.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .