| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-Finance | ₹28.1 L | L1 | Accepted-Finance Admitted |
| 2 | L2₹28.4 LAccepted-Finance | ₹28.4 L | L2 | Accepted-Finance Admitted |
| 3 | L3₹28.5 LAccepted-Finance | ₹28.5 L | L3 | Accepted-Finance Admitted |
| 4 | L4₹28.6 LAccepted-Finance | ₹28.6 L | L4 | Accepted-Finance Admitted |
| 5 | L5₹28.9 LAccepted-Finance | ₹28.9 L | L5 | Accepted-Finance Admitted |
| Sl No | Description | Qty | Unit | GEETA CONSTRUCTION L6 | Sri Gupta Construction L3 | RAMESH GURUNG L5 | PRASAD PRADHAN AND SON L4 | SUNIL PRADHAN L2 | MS BRAHMA CONSTRUCTION L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for ‘B’ check servicing all as per manufacturer instructions, including cost of following ‘B’ check spares and minor spares required for carrying out the check like nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolant in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolant from engine and near by spare parts of engine of capacity 62.5 kVA,complete including testing after repair for its smooth functioning :-
(a) Lubricating oil filter - 01 No
(b) Fuel filter - 02 Nos
(c) Minor spares and waste cotton for cleaning - 01 Kit
Note : 1. Quoted rate deemed to be included fuel filter kits and lubricating oil filter kits and minor spares required for check.
2. Engine oil, Coolant for radiator, distilled water and new air filter element shall be measured and paid separately under relevant items of this schedule. | 1 | Each Job | 15,000 ₹15,000 | 14,282 ₹14,282 | 15,208 ₹15,208 | 14,279 ₹14,279 | 14,922 ₹14,922 | 14,779 ₹14,779 |
| 2.00 | All as per item No 01 above but DG set of capacity 50 KVA etc. complete all as specified and as directed by Engr-in-Charge.
(a) Lubricating oil filter - 01 No
(b) Fuel filter kit - 01 No | 1 | Each Job | 13,500 ₹13,500 | 13,060 ₹13,060 | 13,904 ₹13,904 | 13,774 ₹13,774 | 13,643 ₹13,643 | 13,512 ₹13,512 |
| 3.00 | All as per item No 01 above but DG set of capacity 40 KVA etc. complete all as specified and as directed by Engr-in-Charge.
(a) Lubricating oil filter - 01 No
(b) Fuel filter kit - 01 No | 1 | Each Job | 12,000 ₹12,000 | 11,500 ₹11,500 | 12,166 ₹12,166 | 12,052 ₹12,052 | 11,938 ₹11,938 | 11,823 ₹11,823 |
| 4.00 | All as per item No 01 above but DG set of capacity 30 KVA etc. complete all as specified and as directed by Engr-in-Charge.
(a) Lubricating oil filter - 01 No
(b) Fuel filter kit - 01 No | 1 | Each Job | 11,210 ₹11,210 | 10,220 ₹10,220 | 10,863 ₹10,863 | 10,761 ₹10,761 | 10,659 ₹10,659 | 10,557 ₹10,557 |
| 5.00 | All as per item No 01 above but DG set of capacity 25 KVA etc. complete all as specified and as directed by Engr-in-Charge.
(a) Lubricating oil filter - 01 No
(b) Fuel filter kit - 01 No | 2 | Each Job | 9,200 ₹18,400 | 9,185 ₹18,370 | 9,776 ₹19,552 | 9,684 ₹19,368 | 9,593 ₹19,186 | 9,501 ₹19,002 |
| 6.00 | All as per item No 01 above but DG set of capacity 10 KVA etc. complete all as specified and as directed by Engr-in-Charge.
(a) Lubricating oil filter - 01 No
(b) Fuel filter kit - 01 No | 1 | Each Job | 6,800 ₹6,800 | 6,715 ₹6,715 | 7,155 ₹7,155 | 7,088 ₹7,088 | 7,021 ₹7,021 | 6,954 ₹6,954 |
| 7.00 | Supply only engine oil grade 15W40 against 'B' check servicing and as per the capacity of engine model and as per manufacturers recommendation etc. complete all as specified and as directed by Engr-in-Charge. | 45 | Ltr | 620 ₹27,900 | 610 ₹27,450 | 651 ₹29,295 | 645 ₹29,025 | 639 ₹28,755 | 633 ₹28,485 |
| 8.00 | Supply only coolant against 'B' check servicing for radiator of water cooled engines of any make/capacity and as per manufacturers recommendation etc. complete all as specified and as directed by Engr-in-Charge. | 70 | Ltr | 390 ₹27,300 | 366 ₹25,620 | 380 ₹26,600 | 376 ₹26,320 | 373 ₹26,110 | 356 ₹24,920 |
| 9.00 | Supply and topup / replace distilled water for battery or radiator of engine etc. complete all as specified and as directed by Engr-in-Charge. | 20 | Ltr | 60 ₹1,200 | 60 ₹1,200 | 59 ₹1,180 | 59 ₹1,180 | 58 ₹1,160 | 57 ₹1,140 |
| 10.00 | Supply only Air filter suitable for DG set Engine of make Kirloskar and capacity 62.5 KVA etc. complete all as specified and as directed by Engr-in-Charge. | 1 | Each | 3,750 ₹3,750 | 3,660 ₹3,660 | 3,893 ₹3,893 | 3,857 ₹3,857 | 3,820 ₹3,820 | 3,783 ₹3,783 |
Tender Value
₹25.7 L
EMD Value
₹51,400
Closing Date
15 May 2026, 6:00 pmClosed
GARRISON ENGINEER
GE 867 EWS, C/O 99 APO
REPAIR/MAINT OF DG SETS DG SET PANEL MECHANICAL LOUNDARY LIGHTING CONDUCTOR E/M EQPT AND ALLIED WORKS AT KALIMPONG AND SERWANI MIL STN UNDER GE 867 EWS
2026_MES_761966_1
8587/E8
Open Tender
Civil Works
180 days
KALIMPONG
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE 867 EWS
₹51,400
18 Jun 2026
24 Apr 2026
22 May 2026
24 Apr 2026
15 May 2026
8 May 2026
M&L for ‘B’ check servicing all as per manufacturer instructions, including cost of following ‘B’ check spares and minor spares required for carrying out the check like nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolant in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolant from engine and near by spare parts of engine of capacity 62.5 kVA,complete including testing after repair for its smooth functioning :- (a) Lubricating oil filter - 01 No (b) Fuel filter - 02 Nos (c) Minor spares and waste cotton for cleaning - 01 Kit Note : 1. Quoted rate deemed to be included fuel filter kits and lubricating oil filter kits and minor spares required for check. 2. Engine oil, Coolant for radiator, distilled water and new air filter element shall be measured and paid separately under relevant items of this schedule.
All as per item No 01 above but DG set of capacity 50 KVA etc. complete all as specified and as directed by Engr-in-Charge. (a) Lubricating oil filter - 01 No (b) Fuel filter kit - 01 No
All as per item No 01 above but DG set of capacity 40 KVA etc. complete all as specified and as directed by Engr-in-Charge. (a) Lubricating oil filter - 01 No (b) Fuel filter kit - 01 No
All as per item No 01 above but DG set of capacity 30 KVA etc. complete all as specified and as directed by Engr-in-Charge. (a) Lubricating oil filter - 01 No (b) Fuel filter kit - 01 No
All as per item No 01 above but DG set of capacity 25 KVA etc. complete all as specified and as directed by Engr-in-Charge. (a) Lubricating oil filter - 01 No (b) Fuel filter kit - 01 No
All as per item No 01 above but DG set of capacity 10 KVA etc. complete all as specified and as directed by Engr-in-Charge. (a) Lubricating oil filter - 01 No (b) Fuel filter kit - 01 No
Supply only engine oil grade 15W40 against 'B' check servicing and as per the capacity of engine model and as per manufacturers recommendation etc. complete all as specified and as directed by Engr-in-Charge.
Supply only coolant against 'B' check servicing for radiator of water cooled engines of any make/capacity and as per manufacturers recommendation etc. complete all as specified and as directed by Engr-in-Charge.
Supply and topup / replace distilled water for battery or radiator of engine etc. complete all as specified and as directed by Engr-in-Charge.
Supply only Air filter suitable for DG set Engine of make Kirloskar and capacity 62.5 KVA etc. complete all as specified and as directed by Engr-in-Charge.
Supply only Air filter suitable for DG set Engine of make Kirloskar and capacity 50 KVA etc. complete all as specified and as directed by Engr-in-Charge.
Supply only Air filter suitable for DG set Engine of make Kirloskar and capacity 40 KVA etc. complete all as specified and as directed by Engr-in-Charge.
Supply only Air filter suitable for DG set Engine of make Kirloskar and capacity 25 KVA etc. complete all as specified and as directed by Engr-in-Charge.
Supply only Air filter suitable for DG set Engine of make Kirloskar and capacity 10 KVA etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair of lead acid battery 12 Volts 180 AH having 36 Month warranty including filling of electrolyte, initial charging of battery etc incl making connection with self starter etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair of lead acid battery 12 Volts 150 AH having 36 Month warranty including filling of electrolyte, initial charging of battery etc incl making connection with self starter etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair of lead acid battery 12 Volts 75 AH having 36 Month warranty including filling of electrolyte, initial charging of battery etc incl making connection with self starter etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set 1 x 50 KVA etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set 40 KVA etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set 25 KVA etc. complete all as specified and as directed by Engr-in-Charge.
M&L for descaling and servicing the radiator of DG set 62.5 to 30 KVA of make Kirloskar by internally and externally by using chemicals, to remove deposit on fins and soldering the tubes and tank etc for arresting leakage and re-fixing after replacement of unserviceable hose pipes with clamps and filling of Collent, etc. complete all as specified and as directed by Engr-in-Charge. Note : Coolant excluding will be mesured and paid under respective item.
M&L for descaling and servicing the radiator of DG set 25 to 10 KVA of make Kirloskarinternally and externally by using chemicals, to remove deposit on fins and soldering the tubes and tank etc for arresting leakage and re-fixing after replacement of unserviceable hose pipes with clamps and filling of Collent, etc. complete all as specified and as directed by Engr-in-Charge. Note : Coolant excluding will be mesured and paid under respective item.
M&L for dismantling the unserviceable FIP from DG set engine and taking it to reputed workshop for cleaning, overhauling/servicing and calibration with prescribed overhauling kit of any capacity DG set with replacement of unserviceable parts/spares as required for repair/replacement of injectors, re-fixing the FIP and checking the same for its smooth functioning on DG set etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repairs battery terminal leads of 2AWG (35sqmm) copper wire single core PVC insulated 1.5m long of colour coding red or black complete with brass terminals fixed at site with petroleum jelly etc. complete all as specified and as directed by Engr-in-Charge.
Cleaning of DG set fuel tank capacity upto 62.5 to 40KVA by draining out residul oil and removel of sludge from bottom of the tank etc. complete all as specified and as directed by Engr-in-Charge.
Cleaning of DG set fuel tank capacity upto 30 to 10 KVA by draining out residul oil and removel of sludge from bottom of the tank etc. complete all as specified and as directed by Engr-in-Charge.
Dismantling ,cleaning ,overhauling testing and refitting of fuel injectors of DG set engine of capacity 10 to 62.5 KVA including removal of injectors from cylinder head, cleaning with suitable chemicals replacenment of nozzle ,lapping ,calibration on injector testing machine replacenment of seals/washers ,reassembly and refitting in position etc. complete all as specified and as directed by Engr-in-Charge.
Dismantling of Alternator from DG set ,cables,coupling,foundation bolts shifting to workshop ,opening the covers and strip of burnt damaged stator winding including cleaning of slots, and rewinding of stator with proper super enamelled copper winding wire of approirate gauge ,slot insulation by using unsulating paper,wedges,lacing, varnishing and baking in oven etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair MCB SP 6 to 32 A, 240V,50Hz, C series breaking capacity 10KA etc. complete all as specified and as directed.
S&F in replacement of Power contactor 4 pole 415 Volt, 100Amps including all electric cionnections as per existing etc. complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Power contactor 4 pole 415 Volt, 160Amps including all electric cionnections as per existing etc. complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Power contactor 4 pole 415 Volt, 63Amps including all electric cionnections as per existing etc. complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Auxilary contact unit 4 pole 415 Volt, 16A including all electric cionnections as per existing etc. complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Auxilary contact unit 2 pole, 415 Vot, 16A including all electric cionnections as per existing etc. complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Auxilary contact unit 4 pole, 415 Vot, 10A including all electric cionnections as per existing etc. complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Auxilary contact unit 2 pole, 415 Vot, 10A including all electric cionnections as per existing etc. complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Spare coil for contact unit 2 pole, 415 Vot, 10A Model no L&T MCX-32 including all electric cionnections as per existing etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair 12 & 24 V DC 3 Phase Auto mains failure Microprocessor based relay for Genset ,with 2 Digit, 7 Segment display have LED indicator for input status,DG fault input status, battery status suitable for DG set AMF panel board etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair 415 V AC Protective Relays for over voltage,under voltge, phase reversal relay suitable for AMF/LT panel board etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair fully automatic battery charger input 230V AC and output 12V DC,10 Amp for 12 Volt battery etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair multifunction meter flush mounting accuracy class 1.0 in AMF panel etc. complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of CT 100/5A ratio, 5 VA, CL-1 of DG set Panel /Feeder pillar box etc. complete all as specified and as directed by Engr-in-Charge.
S&F MCCB with Thermal - magnetic release of 63-100 Amps, 4 Pole, 415V, 25 KA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable etc. complete all as specified and as directed.
S&F MCCB with Thermal - magnetic release of 125 Amps, 4 Pole, 415V, 25 KA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable etc. complete all as specified and as directed.
S&F MCCB with Thermal - magnetic release of 200 Amps, 4 Pole, 415V, 36 KA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable etc. complete all as specified and as directed.
S&F MCB, Tripple Pole & Neutral, 40-63 Amps, 415 volts, 50 Hz, 16 KA etc. complete all as specified and as directed.
Labour only for attending breakdowns of DG sets/AMF panels through skilled technician from reputed service centre of DG sets with necessary tool kits, checking Engine and alternator for defects, carryout necessary repairs works to rectify the defects without major overhauling/opening of Engine or Alternators, replacing of worn out parts of AMF panel/DG set and testing DG set for its smooth functioning on full load etc. complete all as specified and as directed by Engr-in-Charge. Note : 1. Necessary spares required to rectify the defects shall be measured and paid separately as supply only under relavant items. 2. The complaint shall be attended and rectifed within 24 hours from time of reporting by Engr-in-Charge or his authorised representative. 3. Any Major defects shall be reported on priority to Engr-in-Charge to avoid undue delay in fuctioning of installation.
Supply only rubber hose pipe set (oil Hose/ radiator hose /CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 20 KVA to 75 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set etc. complete all as specified and as directed by Engr-in-Charge.
Supply only Flywheel ring with proper setting and alignment for upto 62.5 KVA etc. complete all as specified and as directed by Engr-in-Charge.
M&L for disconnecting, dismantling and repairing of turbo charger assembly for DG set including replacement of Kit Turbo Repair , Shaft, Sleeve Turbocharger, Support Turbocharger Seal etc including testing and refixing to its original position properly etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair of automatic voltage regulator (AVR) card of three Phase 415 Volt ,50Hz for alternator of capacity upto 62.5kVA of any capacity etc. complete all as specified and as directed by Engr-in-Charge.
Dismantling unserviceable battery charging dynamo from DG set of rating 1 x 12 / 2 x 12 Volts complete repairs and servicing including replacement of bushes, bearings, Carbon brushes, rectifiers, rewinding of field magnet coil / rotor armeture coils and any other minor parts required all as directed and fixing on engine including testing/commissioning complete for DG set having any capacity upto 62.5kVA etc. complete all as specified and as directed by Engr-in-Charge.
Dismantling old unserviceable Self starter of Diesel engine and supply and fixing new self starter of working voltage 12 volt/24 Volt DC and same as per existing model suitable for fixing on engine set including testing after installation etc. complete all as specified and as directed by Engr-in-Charge.
M&L for disconnecting and taking down burnt self starter, 12 volts DC, from 20 KVA to 62.5 KVA DG sets for repairing including replacement of bendex pinion, bush set, winding of armature and winding of field coil assembly etc and reassembling the same as original complete refixing in its original position including testing etc. complete all as specified and as directed by Engr-in-Charge.
Repair and servicing of existing DG set PCB/ control board including replacenment of burnt electronic components such as resistors capacitors ,Ics relays ,diodes,transistors ,tracks soldering cleaning ,testing etc. complete all as specified and as directed by Engr-in-Charge.
S&F of DG set controller rmodule AMF Type suitable for 10 to 62.5 KVA DG set with display push buttons ,auto /manul operation ,protection (over/under voltage,frequency over load engine protection inculding taking down old unserviceable controller with connections and calibaration of engine sensors such as oil pressure .engine temperature etc. complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches in soft/ loose soil not exc 1.5 mtr wide and not exc 1.5 mtr deep in for lying of electric cable, pole foundation and stays etc and getting out, trimming the sides, forming bottom surfaces to required level etc. complete all as specified and as directed.
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 250mm thick after cable are laid and tested etc. complete all as specified and as directed.
Removing excavated material (Surplus soil) to a distance not exc 50m and depositing where directed at level not exc. 1.5m above the starting point etc. complete all as specified and as directed.
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, total 23 CM complete all as specified. Note - for measurement purpose punned thickeness 18 CM shall be considered etc. complete all as specified and as directed.
S&L sub class B bricks having minimum compressive strength 75 Kg/Sqcm laid in trenches for cable protection etc. complete all as specified and as directed.
M&L in repair for GI pipe light grade 40mm bore with all fittings to be laid in trenches or in floors/fixing with pole,including complete etc. complete all as specified and as directed.
M&L for Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, etc. complete all as specified and as directed by Engr-in-Charge.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel including suitable cable lugs and electric connections all as specified at site cable size of size of 70 Sqmm 3.5 Core etc. complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel including suitable cable lugs and electric connections all as specified at site cable size of size of 50 Sqmm 3.5 Core etc. complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel including suitable cable lugs and electric connections all as specified at site cable size of size of 35 Sqmm 3.5 Core etc. complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel including suitable cable lugs and electric connections all as specified at site cable size of size of 25 Sqmm 4 core etc. complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel including suitable cable lugs and electric connections all as specified at site cable size of size of 10 Sqmm 4 core etc. complete all as specified and as directed.
Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts including with protection pipe etc. complete all as specified and as directed by Engr-in-Charge.
Routine maintenance of Laundry Machine of 30 kg capacity consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set complete including dismantiling laundry machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing etc. complete all as specified and as directed by Engr-in-charge.
Routine maintenance of Dryer of 30 kg capacity consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set complete including dismantiling laundry machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing etc. complete all as specified and as directed by Engr-in-charge.
Routine maintenance of Extractor 15 kg capacity consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set complete including dismantiling laundry machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing etc. complete all as specified and as directed by Engr-in-charge.
Routine maintenance of Laundry Machine 30 kg capacity V belt consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set complete including dismantiling laundry machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing etc. complete all as specified and as directed by Engr-in-charge.
Routine maintenance of Automatic drain valve assembly consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set complete including dismantiling laundry machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing etc. complete all as specified and as directed by Engr-in-charge.
Routine maintenance of Suspension bearing house assembly consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set complete including dismantiling laundry machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing etc. complete all as specified and as directed by Engr-in-charge.
M&L for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised iron strip of size 25 X 4mm earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel,20mm dia GI medium grade watering pipe, 40 mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer etc. complete all as specified and as directed.
S&F in replacement Substation sign board made out of 3 mm thick aluminium composite panel sheet 1200 mm x 1200 mm including retro reflective sheeting on both side fixed on 50 mm dia stainless steel pipe of grade -304 (non scratchable) of wall thickness not less than 14 gauge including providing letters of not less than 75 mm height fixed on position with 50 mm dia stainless steel pipe (wall thickness of pipe shall be not less than 14 guage and vertical height of board above GL should be 2.4 m & below GL 60 cm deep ) and stainles steel pipe embedded in PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in post holes of size 250 mm x 600 mm including 6 mm thick mild steel base size 200 mm x 200 mm X 600 mm including 6 mm thick mild steel base plate of size 200 mm x 200 mm x 6 mm thick for anchoring of post applying of two coats of anti corrossive paint on anchoring plate and writing letters and numbers on both sides of the board in English and Hindi (as required at site) should be as per IRC 30-1968 using 3M material, numbers of letters exc 50 but n exc 250 on each of the board etc. complete all as specified and as directed by Engr-in-Charge.
S&F Symbol on FirstAid box with red colour with white background having following items : (a) Alcohol or non alcohol antiseptic wipes, Band-Aids, cotton Balls, Cotton Swabs, Bandages, Hydrogen Peroxide, Gauge Saline, Dressing, Adhesive bandages, Moleskin, Gloves, Goggles, Surgical mask, Apron, Trauma shears, Alcohol rub, Thermometer, space blanket, Penlight, paracetamol etc. complete all as specified and as directed by Engr-in-Charge.
Supply and installation CO2 4.5 Kg IS: 15683 (Squeez grip valve) carbon Di-oxide agent type fire extinguisher, ISI marked (ISI15683:2018) CE and EN certified, Containing CO2 gas having purity 99.7% filled in seamless cylinder, coated with High glossy PU paint, ISI marked Dual spindle valve with aluminium wheel and collar/Squeeze grip brass valve, aluminium siphon tube, High durability Vinyl label, QR code label with printed serial number, Individually packed in 7 ply corrugated paper box with wall bracket, screw & plugs etc. complete all as specified and as directed by Engr-in-Charge.
Supply and installation ABC fire 4 Kg IS: 15683 Powder based agent type fire extinguisher, ISI marked (ISI15683:2018) CE and EN certified, stored powder based filled in seamless cylinder, coated with High glossy PU paint, ISI marked Dual spindle valve with aluminium wheel and collar/Squeeze grip brass valve, aluminium siphon tube, High durability Vinyl label, QR code label with printed serial number, Individually packed in 7 ply corrugated paper box with wall bracket, screw & plugs etc. complete all as specified and as directed by Engr-in-Charge.
Supply and installation of Fire ball Extinguishers IS: 15683 Powder based agent type fire extinguisher, ISI marked (ISI15683:2018) CE and EN certified, box with wall bracket, screw & plugs etc. complete all as specified and as directed by Engr-in-Charge.
M&L for EM Installation board of Size of the board 900 MM x 1200 MM (Electric shock treatment chart ,instructions chart,Electreic safety chart,IS charts,fire charts )made of 3 mm thick ACP (Aluminium composite panel) with powder coated aluminium frame around the board of fitted with high quality printed vinyl sheet including hanging / fixing arrangement on surface of wall in installation. The given layout shall be drawn using different colour with location and other details etc. complete all as specified and as directed by Engr-in-charge.
M&L for EM Installation board of size of the board 600x 900 MM (VCB inf ) made of 3 mm thick ACP (Aluminium composite panel) with powder coated aluminium frame around the board of fitted with high quality printed vinyl sheet including hanging / fixing arrangement on surface of wall in installation. The given layout shall be drawn using different colour with location and other details etc. complete all as specified and as directed by Engr-in-charge.
M&L for EM Installation board of size of the board 1600 mm x 1000 mm ( VCB Main Lay out chart) made of 3 mm thick ACP (Aluminium composite panel) with powder coated aluminium frame around the board of fitted with high quality printed vinyl sheet including hanging / fixing arrangement on surface of wall in installation. The given layout shall be drawn using different colour with location and other details etc. complete all as specified and as directed by Engr-in-charge.
S&F Sign of size 300 mm X 500 mm reading in Blue background made out of 3 mm thick opaque PVC foam board with computer cut, PVC vinyl painted foam board with white letters properly spaced to provide good legibility with mirror fasteners etc. complete all as specified and as directed by Engr-in-charge.
S&F Sign of size 300 mm X 300 mm reading in Blue background made out of 3 mm thick opaque PVC foam board with computer cut, PVC vinyl painted foam board with white letters properly spaced to provide good legibility with mirror fasteners etc. complete all as specified and as directed by Engr-in-charge.
S&F Sign of size 450 mm X 450 mm reading in Blue background made out of 3 mm thick opaque PVC foam board with computer cut, PVC vinyl painted foam board with white letters properly spaced to provide good legibility with mirror fasteners etc. complete all as specified and as directed by Engr-in-charge.
S&F Sign of size 100 mm X 450 mm reading in Blue background made out of 3 mm thick opaque PVC foam board with computer cut, PVC vinyl painted foam board with white letters properly spaced to provide good legibility with mirror fasteners etc. complete all as specified and as directed by Engr-in-charge.
S&F Sign of size 300 mm X 450 mm reading in Blue background made out of 3 mm thick opaque PVC foam board with computer cut, PVC vinyl painted foam board with white letters properly spaced to provide good legibility with mirror fasteners etc. complete all as specified and as directed by Engr-in-charge.
Supply, fabrication and fixing of acrylic sheet of size 600 mm x 900 mm from clear/opal acrylic of 3 mm thick with high quality vinyl printing (multi colour) pasted on surface ,including cutting edge finishing pasting of vinyl, and fixing on wall with screws rawl plugs stanf off spacers etc. complete all as specified and as directed by Engr-in-Charge.
Supply, fabraction and installation of fire bucket and confirming to IS 256:1974 ,with 4 nos galavanised ,ild steel fire bucket - 04 nos stand made of mild steel frame suitable for hanging fire bracket incuding canopy made of GI sheet painted with red colour etc. complete all as specified and as directed by Engr-in-Charge.
M&L for fabrication of display board for earth pit nos, location and periodical test results for lightening arrester earthing, made of MS sheet 3.0 mm thick sheet, rectangular welding on 12 mm dia rod of height from ground level 30 cm including fixing in PCC 1:2:4 with 20 cm X 20 cm X 20 cm (below ground level) grade aggregate foundation. Dimension of board shall be 30 cm X 25 cm.The instruction shall be written on black painted board with white letters not less than 2 " size for all type of boards etc. complete all as specified and dierected by the Engr -in-charge. Note : (a) All necessary MS sheet, aluminium screws and PCC works etc are deemed to the rate quoted by the contractor
Dismantling of post or struts embedded in concrete, brick work, masonry etc (wood, steel or R.C.C.) of any section, including taking out embedded portion and making good distrubed ground etc. complete all as specified and as directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out in soft/loose soil, including returning, filling in and ramming earth or broken rubble mixed with earth arround, in layers not exceeding 25 cm, watering, and removing surplus soil to a distence n exc 50 m and making good surface etc. complete all as specified and as directed.
M&L Plain cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in foundations, filling and mass concrete etc. complete all as specified and as directed.
S&F MS work of joist, channel, angle or tee sections, fixed independently as in post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc: flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc, and simillar work conforming to Fe-290 Gde E-165, etc. complete all as specified and as directed.
S&F for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut of 5 to 10mm diameter of neck, exc 5cm but not exc 10cm long, etc. complete all as specified and as directed.
M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, etc. complete all as specified and as directed.
Dismantling of fencing wire mesh of any type etc. complete all as specified and as directed.
Supply only chain link MS galvanised fencing any size or type etc. complete all as specified and as directed.
Fixing only chain link fencing including line wires,, any mesh, size and type to any type of standards, rails, straining bolts, welding work including provision of winding wire etc. complete all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc. complete all as specified and as directed.
M&L for brick work with sub class 'B' old size bricks, straight or curved on plan exc. 6m mean radius built in cement mortar (1:4), etc. complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces and finished the surfaces even and smooth without using extra cement etc. complete all as specified and as directed.
M&L for Hardcore of broken stone or boulders of gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15Cm thick, rammed etc. complete all as specified and as directed.
Supply only PVC flat twin core unarmoured Aluminium cable of size 4 Sqmm etc. complete all as specified and as directed.
Supply only PVC flat twin core unarmoured Aluminium cable of size 6 Sqmm etc. complete all as specified and as directed.
Supply only PVC flat twin core unarmoured Aluminium cable of size 10 Sqmm etc. complete all as specified and as directed.
S&F in repalcement of Cone shaped LED Bollard light fittings, 10W, IP 65, diffuser at the upper portion, 0.5 mtr long including fixing arrangemets and eletric connection including excavation of pit and laying cement concrete foundation of size 300 x300 mm using 1:2:4 complete form work with base plate arragenments with anchor bolts including junction boxof size 93x93x 62 all necessary electrical connections etc. complete all as specified and as directed by Engr-in-Charge. Make : crompton Cat PAt No : LBLSN-10-CDL or eqvln Phlips/Havells
NOTE : In case doubling/duplicancy of BOQ items, the lowest quoted rate shall be applicable for payment.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
Tender.pdf
Tender Documents • 0.76 MB
BOQ_853507.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid