Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹16.1 L+₹2.6 L (19.2%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹16.8 L+₹3.3 L (24.7%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹17.8 L+₹4.3 L (31.7%)Rejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹18.8 L+₹5.3 L (39.1%)Rejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE
REPAIR AND MAINTENANCE OF HT SWITCH GEARS, HT CABLES, AND OTHER CONNECTED WORKS AT DGQA OFFICE AND GUNATHA VIHAR UNDER GE (NORTH) BANGALORE
2021_MES_437864_1
86063/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bangalore
As per Tender Documents
6 documents required · 6 mandatory
₹500
GE(North) Bangalore
₹40,000
Yes
HQ CWE ARMY BANGALORE
19 Jul 2021
23 Apr 2021
24 May 2021
23 Apr 2021
22 May 2021
8 May 2021
23 Apr 2021 - 30 Apr 2021
30 Apr 2021
60 days
Amount
Filtration and Dehydration of transformers oil for transformers, through on line filtration equipment to with stand min dielectric strength 40 KV for 1 min at 2.5 mm gap and flash at 60 KV without disturbing/switching off system complete all as directed.
Supply and Topping up of fresh transformer oil suitable for 11 KV systems for transformer having 45KV of minimum dielectric strength complete all as directed.
Preparing the surface of the transformers for painting by cleaning thoroughly the surface for removing dirt, grease, oil, scales etc and spray painting with a coat of synthetic enamel paint of suitable/specified colour as directed including painting/writing the SM and MES No on the transformer with white paint complete all as directed of the following capacities:- (a) Transformer 400 KVA
All a per item No 3.1 herein before but for Transformer 300 KVA
All a per item No 3.1 herein before but Transformer 250 KVA
All a per item No 3.1 herein before but Transformer 200 KVA
All a per item No 3.1 herein before but Transformer 100 KVA
Earthing with earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connected to and including earthing of GI strip 32 x 6mm by means of bolts, nuts, check nuts and washers made of GI and protected by light grade 40mm dia GI pipe connected to main switch board or control board and GI pipe light grade 20mm dia for watering and including funnel, wire mesh, precast RCC pit cover 40mm thick in cement concrete 1:2:4, type B1 with 8mm dia MS reinforcement at 10cm centre to centre both ways and PCC chamber pit with PCC 1:3:6 type C1 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50m all as specified and shown on plate No 3 of SSR Part I 2009 including taking out old unserviceable earthing. Note: - (i) Earthing strip and protection pipe to a length of 7.5 m is deemed to be included in the rate of this item. (ii) The unit rate deemed to include taking out old earthing.
Disconnecting, defective Indoor/outdoor transformer of following capacity, drain out complete transformer oil storing the same in suitable container to be provided by the contractor, lifting of the top cover, taking out core & core assembly carefully with the help of chain pulling/ Crane after disconnecting LT/HT connection to check its condition, cleaning the tank & core taking down &servicing of defective HT/LT bushes with brass spindle, nuts, bolts, washers insulation lowering back the core assembly after all necessary repair as directed here-in-after refilling filtered transformer oil taking down & providing the new synthetic rubberized cork sheet making all HT/LT incoming & outgoing connections including testing & commissioning complete all as directed. Note: - Supply only HT/LT bushes will be measured and paid separately. (a) 100 KVA Capacity
All a per item No 5.1 herein before but for 200 KVA Capacity
All a per item No 5.1 herein before but for 250 KVA Capacity
All a per item No 5.1 herein before but for 400KVA Capacity
Supply only HT bushes suitable for 100 KVA to 200 KVA transformer of Make :- BHEL/JAYSHREE
Supply only HT bushes suitable for 250 KVA to 400KVA transformer of Make :- BHEL/JAYSHREE
Supply only LT bushes suitable for 100 KVA to 200 KVA transformer of Make :- BHEL/JAYSHREE
Supply only LT bushes suitable for 250 KVA to 400 KVA transformer of Make :- BHEL/JAYSHREE
Dismantling the unserviceable indoor / outdoor transformer of capacity 100 KVA to 200 KVA from bed by disconnecting incoming/outgoing HT/ LT side connections, removing the earth strip connections from transformer body and neutral point, and cable connections etc from structure / sub stations and transportation to workshop for winding. with the help of chain pulling/ Crane , draining the total oil, inspecting thoroughly for the defective High voltage/Low voltage windings, carry out the testing of total active parts. Over hauling the core and balance coils flushing with hot oil for removal of copper particles, sludge and any other unwanted particles. Cutting and removing of burnt transformer winding HV/LV and providing new winding at both HV/LV and replacing with copper conductor of same size and gauge to achieve transformer rated capacity and new insulation materials such as FRP studs, spares, runners, gaskets including brazing etc, resetting/fixing the core assembly and with pry/sec brazing as required and all necessary connections. Drying out of core coil assembly, cleaning of inside and outside of the tank by sand blasting process including replacing of tank gasket .Providing insulation for over all winding and re-assembly connections with provisions of new gasket and insulation materials putting back the cover tightening the fixture, fixing the bushes, bolts and nuts etc., Painting of the transformer including transportation from workshop to substation including testing & commissioning complete all as directed.
Dismantling the unserviceable indoor / outdoor transformer of capacity 250 KVA to 400 KVA from bed by disconnecting incoming/outgoing HT/ LT side connections, removing the earth strip connections from transformer body and neutral point, and cable connections etc from structure / sub stations and transportation workshop for winding with the help of chain pulling/ Crane , draining the total oil, inspecting thoroughly for the defective High voltage/Low voltage windings, carry out the testing of total active parts. Over hauling the core and balance coils flushing with hot oil for removal of copper particles, sludge and any other unwanted particles. Cutting and removing of burnt transformer winding HV/LV and providing new winding at both HV/LV and replacing with copper conductor of same size and gauge to achieve transformer rated capacity and new insulation materials such as FRP studs, spares, runners, gaskets including brazing etc, resetting/fixing the core assembly and with pry/sec brazing as required and all necessary connections. Drying out of core coil assembly, cleaning of inside and outside of the tank by sand blasting process including replacing of tank gasket .Providing insulation for over all winding and re-assembly connections with provisions of new gasket and insulation materials putting back the cover tightening the fixture, fixing the bushes, bolts and nuts etc., Painting of the transformer including transportation from workshop to substation including testing & commissioning complete all as directed. Note :- For items No 5,10 & 11 Filtration/topping up of oil will be measured separately under Ser item No 1 &2
Taking down transformer of any Make/capacity by disconnecting HT/LT connection and shifting from one location to another location with the help of chain pulley/crane and re-connecting to HT/LT connection at new location complete all as directed.
Breather assembly as per existing sizes completes all as directed. Note : Silica gel required for breather will be measured & paid separately under item no 14
Silica gel filling complete all as directed.
GI strip of sizes 32 x 6 mm fixed on walls/poles/ shafts/pipes, etc including taking down existing strip complete all as directed.
ACSR (Aluminium conductor steel reinforced) conductor of any size of on poles including binding wire of appropriate size complete including clearing of path and branch cutting etc complete all as directed.
Replacement of outdoor type triple pole switch air brake (gang operated) each pole consisting of galvanized steel base HT insulators as per BSS/ISS , non ferrous knife and spring loaded contact , arcing horn mechanically operated , horizontal /vertical type mounted on insulator and steel frame complete , current rating up to 400 Amps complete all as directed
Replacement of lightening arrestor metal oxide type complete with all fittings transmission class discharge capacity 65 Kilo Amps suitable for 11000 volts grade complete all as directed.
Replacement of expulsion fuse unit 11 KV drop out up to 25 Amps complete all as directed.
Replacement of disc type insulator porcelain vitreous 145 mm high and 255 mm dia ball and socket type white or brown single disc assembly for tension clamps for conductors working pressure 11000 volts complete all as directed.
Replacement of iron work of any type including cross arms supports, bracing MS clamps etc made out of MS channel/angle iron/ flat iron/ round section of any size and bolts, nuts and washers include painting with two coats of aluminium paint over a coat of red oxide complete all as directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as directed.
Servicing of existing GOD with replacement with GI nuts bolts, washers and lugs etc as per site requirement including necessary greasing and cleaning with petroleum jelly complete all as directed.
Supply and Laying of coarse aggregate of size 40mm grade inside the area of sub stations at various locations including removing old coarse stone aggregate complete all as directed.( Note: - Removed stone aggregate shall be reused and paid under separate item.)
Spraying of old collected coarse aggregate grade inside the area of sub stations at various locations complete all as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out in hard/dense soil complete all as directed.
Returning, filling in of exceeding soil including spreading leveling watering and well ramming in layers not exceeding 25 cm complete all as directed.
Removing of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed.
Filling approved river sand in trenches for sand cushion for laying of cable punned down etc complete all as directed. Note : The punned thickness only shall be measured
Unreinforced precast concrete cable cover HV type size 380mm x 180mm x40mm , laid flat across the cable length complete all as directed.
Supply, laying, joining & testing and connecting HT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heave duty) with aluminium conductor, 11000 Volts grade of size 120 Sqmm 3 core suitable for 11 KV(E) system laid in trenches/ducts/encased in GI pipe/fixed to pole complete all as directed. Note :- (i) Excavation earth work sand cushioning, PCC cover, GI pipe will be measured and paid separately under respective items
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including and inserting HDPE pipe of 100 mm dia bore suitable for 0.4 mpa working pressure complete all as directed.
GI tubing light grade 80 mm bore with all fitting laid in trenches/walls/Roads/pole for cable protection complete all as directed.
NAVREET CONSTRUCTION
M/S Bhagyawanticonstruction
M/S - KRUPA ELECTRICALS
B5BUILDING SOLUTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .