Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC P METTUPALAYAM PILLANATHAM P O TIRUCHENGODE TK NAMAKKAL 637 205 | NAMAKKAL | NAMAKKAL | TAMIL NADU | 637205 | ₹1.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 CrRejected-Finance NO 103 KAMARAJ NAGAR 1ST STREET BHAVANI 638301 ERODE DT | BHAVANI | ERODE | TAMIL NADU | 638301 | ₹1.6 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹1.6 CrRejected-Finance | ₹1.6 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹1.6 CrRejected-Finance | ₹1.6 Cr | L4 | Rejected-Finance L4 |
| 5 | L5₹1.7 CrRejected-Finance PLOT NO 5 SATHYAM GARDEN UYIRIYAL POONGA ROAD GORIMEDU SALEM 636 008 | SALEM | SALEM | TAMIL NADU | 636008 | ₹1.7 Cr | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | MANICKAVASAGAM L4 | MSS CONTRACTORS L6 | Arun and Co L3 | RAJ ENGINEERING CONTRACTOR L5 | mk constructions L2 | G MOHANRAJ L1 | M s Kumaresan and co L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Clearing Heavy jungle and disposing off to a place away from the site as directed by the Engineer in charge including all labour charges, T&Ps etc., complete. | 1,800 | sqm | 5 ₹9,000 | 1 ₹1,800 | 5 ₹9,000 | 5 ₹9,000 | 5 ₹9,000 | 8 ₹14,400 | 5 ₹9,000 |
| 2.00 | Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete for in hard gravelly soil | 455 | cum | 100 ₹45,500 | 270 ₹1.2 L | 180 ₹81,900 | 250 ₹1.1 L | 250 ₹1.1 L | 215 ₹97,825 | 250 ₹1.1 L |
| 3.00 | Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete for In SDR (Not Requiring Blasting) | 76 | cum | 150 ₹11,400 | 400 ₹30,400 | 200 ₹15,200 | 250 ₹19,000 | 350 ₹26,600 | 320 ₹24,320 | 400 ₹30,400 |
| 4.00 | Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete for Medium rock and dense medium rock not requiring blasting | 76 | cum | 200 ₹15,200 | 100 ₹7,600 | 260 ₹19,760 | 250 ₹19,000 | 550 ₹41,800 | 570 ₹43,320 | 600 ₹45,600 |
| 5.00 | Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete by Removal of hard rock by blasting | 114 | cum | 250 ₹28,500 | 100 ₹11,400 | 349 ₹39,786 | 1,500 ₹1.7 L | 1,600 ₹1.8 L | 1,535 ₹1.7 L | 1,000 ₹1.1 L |
| 6.00 | Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete by Removal of hard rock by wedging and chiselling and trimming to proper shape | 38 | cum | 250 ₹9,500 | 100 ₹3,800 | 380 ₹14,440 | 1,500 ₹57,000 | 2,500 ₹95,000 | 3,065 ₹1.2 L | 1,500 ₹57,000 |
| 7.00 | Filling the M-sand for filling in the foundation and floor including cost of sand, filling charges as per standard specification(watering & consolidation with all leads and lifts etc., complete. | 22 | cum | 1,000 ₹22,000 | 2,000 ₹44,000 | 2,400 ₹52,800 | 1,000 ₹22,000 | 1,300 ₹28,600 | 1,925 ₹42,350 | 1,000 ₹22,000 |
| 8.00 | Providing anti termite treatment in 4 stages I) immediate after earth work excavation and before laying foundation concrete II) after refilling for sides of foundation III) Before laying of flooring concrete IV) outside of basement upto 1.0m around the building using BIFLEX-C termite 250ml for 10 lit of water etc., complete. | 172 | sqm | 200 ₹34,400 | 250 ₹43,000 | 430 ₹73,960 | 15 ₹2,580 | 175 ₹30,100 | 230 ₹39,560 | 100 ₹17,200 |
| 9.00 | PCC 1:3:6 using 20mm HBG metal for foundation including cost of cement without formwork all materials, labour, lead, lift etc. complete. | 369 | cum | 5,900 ₹21.8 L | 5,000 ₹18.4 L | 5,000 ₹18.4 L | 4,730 ₹17.5 L | 5,000 ₹18.4 L | 5,700 ₹21.0 L | 7,000 ₹25.8 L |
| 10.00 | PCC 1:2:4 mix using 20mm downgraded HBG machine crushed metal for foundation concrete, cost of all labour, materials, lead, lift, curing etc. complete as per standard specification. With form work | 89 | cum | 8,800 ₹7.8 L | 11,000 ₹9.8 L | 8,700 ₹7.7 L | 6,230 ₹5.5 L | 7,500 ₹6.7 L | 9,560 ₹8.5 L | 10,000 ₹8.9 L |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
28 Jan 2026, 2:30 pmClosed
CE/TP-I/CNI
O/o the Chief Engineer/Transmission Projects I / Chennai, 3rd Floor , 110 KV GIS Substation building A-10, Guindy Industrial Estate, Guindy, Chennai -32.
Construction of control room Building with Electrification, Providing Bore well , providing RCC road and chain link fencing alround area and all allied civil works for the proposed new Ranganoor 110/22 KV SS
2026_EB_642875_1
TP1-157/2025-26 OF CE/TP-I/CNI
Open Tender
Civil Works
270 days
RANGANOOR
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.7 L
27 Apr 2026
13 Jan 2026
29 Jan 2026
13 Jan 2026
28 Jan 2026
13 Jan 2026
Clearing Heavy jungle and disposing off to a place away from the site as directed by the Engineer in charge including all labour charges, T&Ps etc., complete.
Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete for in hard gravelly soil
Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete for In SDR (Not Requiring Blasting)
Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete for Medium rock and dense medium rock not requiring blasting
Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete by Removal of hard rock by blasting
Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete by Removal of hard rock by wedging and chiselling and trimming to proper shape
Filling the M-sand for filling in the foundation and floor including cost of sand, filling charges as per standard specification(watering & consolidation with all leads and lifts etc., complete.
Providing anti termite treatment in 4 stages I) immediate after earth work excavation and before laying foundation concrete II) after refilling for sides of foundation III) Before laying of flooring concrete IV) outside of basement upto 1.0m around the building using BIFLEX-C termite 250ml for 10 lit of water etc., complete.
PCC 1:3:6 using 20mm HBG metal for foundation including cost of cement without formwork all materials, labour, lead, lift etc. complete.
PCC 1:2:4 mix using 20mm downgraded HBG machine crushed metal for foundation concrete, cost of all labour, materials, lead, lift, curing etc. complete as per standard specification. With form work
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for control room footing concrete with formwork including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For control room footing concrete )
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for control room column concrete with formwork upto base ment including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For control room column concrete upto base ment )
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for control room column concrete with formwork above base ment upto ground floor base ment including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For control room column concrete above basement upto Ground floor )
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for control room Grade beam concrete with formwork including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For control room Grade beam )
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for control room Plith beam concrete with formwork including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For control room Plinth beam )
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for control room Continous lintel beam with formwork including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For control room Continous lintel beam )
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for control room sunshade with formwork including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For control room Continous sunshade concrete)
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for control room roof beam with formwork including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For control room roof beam concrete )
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for control room roof slab of 130 mm tk with formwork including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For control room roof roof slab of 130 mm tk )
RCC 1:1.5:3 using 12 to 20 mm machine crushed metal for Septic tank & Oil sump slab tk with formwork including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( for Septic tank & Oil sump slab )
RCC 1:1.5:3 using 12 to 20mm machine crushed metal for road concrete with formwork including cost of all materials, labour lead, litf, curing, etc., complete. Excluding the cost of steel reinforcement ( For road concrete )
Providing steel reinforcement using steel of grade Fe 500 for RCC works including cost of steel, binding wire and placing in postion of the steel reinforcement, including cost of all materials, lead, lift, etc., complete.
Brick work in CM 1:5 using II class chamber burnt bricks for basement & superstructure including cost of all materials, all labour, lead, lift, curing, etc., complete.
Brick work in CM 1:3 using II class chamber burnt bricks for partition wall including cost of all materials, all labour charges, curing, lead, lift, etc., complete.
Plastering with CM 1:5, 12 mm thick for walls including cost of all materials, curing, labour, lead, lift, etc., complete.
Plastering with CM 1:3 12 mm thick for ceiling, beams, sunshade including cost of all materials, curing, labour, lead, lift, etc., complete.
Providing Damp proof course using cement mortar 1:3, 20 mm thick with water proofing compound including cost of all materials, lead, lift, etc., complete.
White washing 2 coats using emulsion paint over one coat of primer with white colour for ceiling in all floors and exposed faces of beams including cost of all materials and scaffolding etc. complete.
Painting the inside walls and control room front face with two coats of best quality interior emulsion using Asian ULTIMA or Equivalent of approved Brand over primer one coat and two coats of wall putty of (Brila Putty) approved colour including cost of all materials and scaffolding etc. complete.
Colour washing 2 Coats over a base coat of primer using Exterior weather coat using Asian ULTIMA or Equivalent of approved Brand,quality and colour for outer wall surfaces for all floors including cost of all labours to work at all levels cost of materials brushes scaffolding charges etc. complete complying with standard specification and as directed.
Paving the floor with best quality Double Charged Vitrified Tiles of size 600 x 600 x 8 mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20 mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. ( sample to be approved by Dept.Engineer)
Paving the floor with acid resistant tiles (quality, colour and shade as directed by the engineer at site) of size 305 mm x 305mm x 8mm in battery room over a base layer of cement mortar 1:3 (one cement and three sand ) 20 mm thick laid in-situ and pointed with same coloured cement ( sample to be approved by Dept.Engineer)
Flooring with approved ceramic tiles 305mmx305 mm non slipery over cement mortor 1:3 20 mm thick including pointing with white cement finishing the joints flush pointing the surface etc complete ( sample to be approved by Dept.Engineer)
Paving the floor with best approved quality Pre-polished anti-skid step tiles of 20 mm thick laid over a cement mortar bed of 20 mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., complete as per standard speicification. (sample to be approved by Dept.Engineer)
Dadooing walls with approved quality of Glazed tils of size 300x200 laied in cement mortor 1:2 10mm thick including pointing with white cement finishing the joints flush pointing the surface etc complete( sample to be approved by Dept.Engineer)
Dadooing walls with with acid resistant tiles (quality, colour and shade as directed by the engineer at site) of size 305 mm x 305mm x 8 mm of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10 mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Providing and laying weather proof Tiles 300 mm x 300 mm size over screed concrete 1:3:6 with average thickness of 25 mm for required gradient and using best quality of one course of weather proof tiles of approved quality using in cm 1:3, 12 mm thick and using 3mm spacer and pointing with water Repellent U Bond and grout including cost of all materials ,transport curing etc complete.
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
Supply and fixing of solid PVC door with frame made out of rigid thermo vinyl polymer extruded section ofsize 62mmx51mm with 2mm wall thickness,shall be reinforced with special polymeric rods of size 255mmx30mmx25mm and with EPDM gaskets along the frame. The door shutter frame of 40mm thickmade out of one piece moulded rigid thermo vinyl polymer extruded sectionof size 25mmx40mm with 2mm wall thickness is mitered and joinedat corners by stainless steel/ aluminium screws. The infill of the door shutterconsists of a seamless one piece multichamber hollow rigid thermo vinyl polymer sectionof size 762mmx35mm with 1mm wall thickness and with prelaminated glossy finish on either side of door shutter of suitable size including cost of all materials, lead, lift, etc., complete.
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supplying and fixing of colour Europian type water closet with flushing cistern of Neycer/Parry ware with P"" or "S" trap, seat cover 15 mm dia connecting hos. 2 nos 15 mm dia CP angle valve, hand shower -1 No. including cost of all materials, lead, lift, etc., complete as directed by department Engineer at site
Supplying and fixing in position IWC ORISSA PAN of size 580 X 420 mm colour glazed earthen ware of approved make & quality with 'P' or 'S' trap conforming to IS - 2556 Part XII [Parryware or Equivalent] with sand cushion and forming flooring around the cloast using 40mm broken brick jelly in lime concrete 1:2:5 [1/lime, 2/sand & 5/brick jelly] 100mm thick and finishing the top to required slope and giving connection to sewer line including the cost of all materials, labour, lead, lift, T&P, etc., complete.
Supply and fixing of white colour wash basin of size 550 x 400 mm with all accessories such as cast iron brackets, 32 mm dia C.P waste coupling, rubber plug and chain, 32 mm dia 'B' Class G.I. waste pipe etc., 15 mm dia GM wheel valve, 15 mm dia nylon connection, complete.
Supplying and fixing in position 110 mm dia, best quality ventilating shaft 3.65 m height with PVC cowl at top inlcuding cost of all materials, curing labour, leads, lifts, etc., complete.
Supplying and fixing in position 165 mm dia PVC soil pipe- 6kg/sq.cm [Finolex or equivalent] with special clamps & PVC shoe at bottom including the cost of all materials, labour, lead, lift, T&P, etc., complete
Supplying and filling with 40 mm HBG metal in dispersion trench, rain water harvesting pit, transformer oil drain pit including cost of metal, all labour, lead, lift, consolidation, etc.,complete.
Supply and fixing 110mm dia PVC down fall pipe 4 kg/cm2 avonplast or Finolex make with required bend, tee and GI wall clamp at 90cm intervals including cost of materials, labour, lead, lift, etc., complete.
Providing and laying PVC high density pipe (10 kg. per cm2 ) including cost of all specials like coupling, bend etc., and including necessary earthwork and burrying , all material labour, etc., complete and as directed by the Engineer-in-charge at site.. For 40 mm dia
Providing and laying PVC high density pipe (10 kg. per cm2 ) including cost of all specials like coupling, bend etc., and including necessary earthwork and burrying , all material labour, etc., complete and as directed by the Engineer-in-charge at site.. For 32 mm dia
Providing and laying PVC high density pipe (10 kg. per cm2 ) including cost of all specials like coupling, bend etc., and including necessary earthwork and burrying , all material labour, etc., complete and as directed by the Engineer-in-charge at site.. For 25 mm dia
Providing and laying PVC high density pipe (10 kg. per cm2 ) including cost of all specials like coupling, bend etc., and including necessary earthwork and burrying , all material labour, etc., complete and as directed by the Engineer-in-charge at site.. For 20 mm dia
Providing and fixing Gate valve of 40 mm diameter of Gun metal made including cost of all materials, labour, lead and lift etc., complete and as directed by the Engineer-in-charge at site.
Providing and fixing Gate valve of 32 mm diameter of Gun metal made including cost of all materials, labour, lead and lift etc., complete and as directed by the Engineer-in-charge at site.
Providing and fixing wheel valve of 32 mm diameter of Gun metal made including cost of all materials, labour, lead and lift etc., complete and as directed by the Engineer-in-charge at site.
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead, lift etc., complete. For S Type chair (Local rate)
Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead, lift etc., complete. For Three drawer steel table with Sunmica top of size 1200x750x750mm
Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead, lift etc., complete. For Steel side rack open type 1100x400x1200
Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead, lift etc., complete. For Steel half bench 1200x400x600mm
Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead, lift etc., complete. For PVC Nylon chair of approved quality
Supplying and fixing the name/ designation stickers in doors identifying the rooms including cost of material, labour, etc., complete.
Providing Sintex water tank of capacity of 1000 lits including cost of material, labour, lead, lift, transportation and placing in position over head room etc., as directed by the engineer at site.
Supplying and fixing Digital wall clock 2 Nos, floor coir mat 2000x600 for Entrance 1000x500 - 2 No. for office of approved make and quality including the cost of all materials, leads, lift, etc., complete
Supply, Transport & fixing of GI angles for cableduct splitting the fixed end of angle for anchorage and placing in position as directed by the engineer at site including cost of angles including cost of material, all labour, lead, lift, etc., complete.
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification.
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications.
Providing projected border of 7.50 cm width on top of parapet wall in CM 1:3 mix 12mm thick including cost of all material labour, lead, lift, curing, etc., complete.
Providing projected border of 20 cm. width for plinth beam in CM. 1:3 20mm thick including cost of all materials, labour, lead, lift, etc., complete.
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Supplying and fixing 110 mm dia PVC.Bend including cost of materials, labour, lead, lift, etc., Complete
Supplying and fixing 110 mm dia PVC TEE including cost of materials, labour lead, lift, etc., Complete
Supplying and fixing of two side polished 20 - 30 mm tk cuddapah slab for cupboard etc., including cost of all materials, labour, lead, lift, etc., complete
Supplying, filling & spreading of good quality gravel layer by layer with proper consolidation for control room inside including cost of all materials, labour, lead, lift etc., Complete.
Writing the name of sub station and safety slogn on wall over plasterd surface using approved colour and quality enamel paint over a cost of primer including cost of all materials , lead,lift etc., complete
Conducting Water divining Test for fixing of Bore well point including cost of all hire charges of T&P and Transport charges etc complete.
Drilling bore well of 150 mm dia 6” in all soils, hard rock etc., including transporting of machineries with equipments and all necessary T & P’s labouretc., complete as per specification. Upto 100 Mts
Drilling bore well of 150 mm dia 6” in all soils, hard rock etc., including transporting of machineries with equipments and all necessary T & P’s labouretc., complete as per specification. Beyound 100 Mts
Supply and erection of 180 mm (7”) dia rigid PVC casing pipe, having 6 kg/cm² including cost all materials,lead, lift, re-boring the holes to required depth etc., complete with cover at the top of the bore well.
Supply and erection of 5 HP ELGI compressor (or) any other reputed make of pump having ISI make with 3phase suguna (or) any other approved make 400V/440/50 cycle motor (5 HP) having ISI make (or) as approved by the Board Engineer at site with air pipe of 20mm dia to pump water to a height of 175mts.and delivery unit with foot valve v-belt arrangement including cost of all materials, labour, erection charges, 5 HP, 400/440V L&T make starter to suit the compressor including the cost of all materials, labour, lead and as per the instruction of Engineer in charge at site complete in all respects.
Supply and erection of 3 phase 30/32 Amps ICTP switch with fuse arrangements to suit the compressor with cost of all materials, labour, lead and lift etc., complete in all respects.
Supply and erection of 40 mm dia HDPE hose in black colour having ISI mark and as per IS 4984 -84,40mm dia (10 Kg/CM²) in and outside of the bore well including cost of all materials, labour, lead,lift etc., complete.
Supply and erection of 20 mm dia HDPE hose in black colour and havingISI mark and as per IS 4984 - 87, (15 Kg/CM²) in and outside of bore well including cost of all materials, labour, lead, lift etc., complete.
Supply and fixing of 15 Amps main fuse carrier in T.W.Board (600x600mm) with hings,screw, hook wall varnished including cost of all materials, lead, lift etc., complete in all respects.
Supply and laying of 12 mm G.I. pipe of medium class for air compressor cost of G.I pipe, specials, cutting, threading, labour, lead, lift as per the instruction of Engineer in charge at site.
Labour charges for laying of 4 core 6 Sq mm power cable from nearest power point to 5 HP motor including earth work excavation ,laying power cable in the pit and top covered with country bricks and refilling with excavated earth, lead. lift , etc. complete
Supplying and erection of 1HP mono block 3 phase electrical motor of approved brand with all related accessories as per IsI in all respect including oil level indicator switch board with 3 Nos. test lamp, 3 Nos. fuse carrier, 1 No. 15AMPS DPIC swithch with L&T make starter with guard and providing earthing to main with no. 8 tinned copper wire rod and 6' long 40mm dia GI pipe for earthing and earth pit filled with charcoal and salt as per standard spectification and laying motor bed by concrete with placing motor over bed, labour charge for placing motor over bed including cost of all materilas lead and lift etc, complete as driected by the department engineer at site.
Providing expansion joint for road concrete as per specification in both direction using prevalid aspheltics pad 20 mm thick to full width and depth of 150mm thick plastering with CM 1:3, 20 mm thick including cost of cement, all materials, labour, curing, all leads, and lifts, etc., complete.as per standard specification.
Supply and fixing of 50 Sq.mm GI Chain link fencing of 9 gauge with standard width of 1.80 m height including cost of all material, labour for fixing, transportion, lead, lift, etc., complete.
Wiring with 2 x 1.5 sq.mm (22/0.3) PVC insulated SC unsheathed multistrand Copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with Steel switch box and 5A F.T switch with continuous earthwire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point/fan point
Supply and run of 2 x 1.5 sq.mm (22/0.3) PVC insulated Multistrand unsheathed copper conductor of 1100 V grade.
Wiring with 2x1.5 sq.mm (22/0.3) PVC insulated SC unsheathed Cu.conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall ,with 150x100x113mm TW switch box with 3 mm thick hylum sheet cover for 5 A 3 Pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC Plug point.
Wiring with 2 x 4 sq.mm (56/0.3) PVC insulated multi strand unsheathed copper conductor cable of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150 mm x 100 mm x 113 mm Steel switch box with 3 mm thick hylem sheet for 15 A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion, with suitable colour for concealed power plug point.
Supply and fixing of 32 A TPN MC switch on suitable angle iron frame work with MS cable entry box with earth connection only.
Supply and run of 4 of 4 sq.mm (56/0.3) PVC insulated multi strand unsheathed copper conductor of 1100 V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour.
Supplying and fixing box type 4'-40 w single flouresent fitting complete with copper choke and condenser 1 no 4'-40w tube with T.W. round block on wall or ceiling with pvc unsheated leads from terminals to the fittings
Supply and fixing of 4' 40 W Twin Mirror optic suspension type fitting (Philips / Crompton / Wipro) complete with louvers cover complete with copper choke and condensor with conduit pipe suspension, with PVC unsheathed Copper leads from the terminals to the fittings with flu. tubes.
Supplying and fixing of water tight Bulk head fitting with guard and approved suitable make for incondescent lamp with guard and 100 w bulb.
Supply and fixing of fancy glass shade and 7 W / 9 W LED bulb
Supply and fixing of 1400 mm sweep (56") AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod including fan clamp with side plates and cross arm of size 450 mm.
Supply and fixing of 450 mm (18") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall.
Supplying and fixing of RCCB safe trip of appd LEGRAND, ISI make, 25amps with suitable box including cost of all materials labour, lead, lift, etc., complete as per standard specification.
Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40A 4 pole MCB isolater as incoming and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make).
Earthing as per PWD standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32 mm complete with necessary masonry work.
Supply and fixing of 3 phase 4 wire 4 way ICDB of 32 Amps per way with 63 A TPN MC switch with suitable trunking box MS cable entry and internal connection in suitable angle iron frame work, with earth connections.
Supplying and fixing MS grill gates, MS grills, name board, hand rail, lader etc. at various levels as per approved drawing using channel, squar rods, ornamentel grill parts and flat including fixing in position with suitable hold fast locking arrangements, painting with one coat of primer and two coats of Enamel paints of approved colour etc.complete as per standard specification
CGST in % (For Bidders inside TamilNadu)
SGST in % (For Bidders inside TamilNadu)
IGST in % (For Bidders outside TamilNadu)
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
BOQ_770253.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid