Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.1 LAccepted-AOC HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L1 | Accepted-AOC Accept
Being L1 | |
| 2 | L2₹45.4 L+₹4.3 L (10.3%)Rejected-AOC RSD STREET HALL BAZAR AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L2 | Rejected-AOC Reject
Being L2 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
13 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) LEH
HQ CWE(AF) LEH
PROVN OF WORK SERVICES FOR INSTALLATION OF OXYGEN GENERATION PLANT AT AIR FORCE STATION LEH
2022_MES_547328_2
81148/E8
Open Tender
Civil Works
Item Rate
180 days
LEH
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Leh
₹84,000
Yes
19 Nov 2022
22 Sept 2022
15 Oct 2022
22 Sept 2022
13 Oct 2022
29 Sept 2022
Amount
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and depth exceeding 1.5 metre but not exceeding 3.0 metre deep for laying of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover HV type-1, flat, of size 300x180x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, including taking out old and removal, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of High Tension (HT) XLPE insulated, galvanised steel strip or wire armoured, heavy duty, electric power cable, cross sectional area 95 Sqmm 3 core aluminum conductor 11000 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note(s): (i) Returning filling earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 150 Sqmm 3.5 core aluminum conductor 1100volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, including taking out old and removal, complete all as specified and as directed. Note(s): (i) Excavation & earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
All as per serial Item No. 8.00 here-in-before but cross sectional area 35Sqmm 3.5 core aluminum.
All as per serial Item No. 8.00 here-in-before but cross sectional area 25Sqmm 4 core aluminum.
Supply and fixing/erecting in true vertical position, steel tubular pole, swaged, type 410-SP-55 (11.0m long), HT, complete with cast iron base plate of size 400mm x 400mm and thickness 5mm, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paint and painting upto 1.5 metre above PCC benching of poles in black & white strips 05 Nos each including taking down existing pole complete all as specified and directed. Note : Earth work and PCC in foundation and coping shall be measured and paid separately.
Material and labour, Cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section Fe-290 grade E-165 quality including nuts, bolts, washers, and welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminium paint over a coat of red oxide primer, in replacement, complete all as specified and directed.
Material and labour, Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Material and labour, Plain Cement Concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Material and labour, PCC (1:2:4) type B-1, using 20mm graded crushed stone aggregate, as in coping to parapet walls, electric poles etc., weathering slightly, rounded or chamfered including use waste and necessary form work , complete all as specified and directed.
Material and labour, Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps suitable for 11000volts grade system, in replacement, complete all as specified and directed. .
Supply, jointing & testing, indoor termination joint kit Heat shrinkable type complete with jointing material and accessories suitable for 11KV grade (earthed), HT, underground XLPE insulated armoured aluminium conductor, 3core 95 Sqmm size cable, complete all as specified and directed.
Material and labour, disc type insulator, porcelain, vitreous, 145mm high and 255mm dia, ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000volts, fixed in position, complete all as specified and directed.
Material and labour, pin type insulator porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, of 150mm height and 150mm dia, for working pressure 11000volts grade, fixed in position, complete all as specified and directed.
Supply, installation ,commissioning and testing Servo controlled Voltage stabilizer of capacity 200 KVA, confirming to BIS 9815 Part-I:1994 3 phase 50Hz naturally oil cooled indoor unbalanced type copper wound digital display voltmeter/ammeter type , relay pre smooth and silent operation with first fill of transformer oil (IS 335 of 1993) having specifications, designed for input voltage variation between 340 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 8 Volts per second for single plate and 20 volts per second for phase to phase, no load losses less than 0.5%, full load losses less than 2.5 % duty cycle continuous 24x7,efficiency more than 95% with protection of overload/short circuit protection ,High/low voltage cut off by pass arrangement in case of emergency , single phase sequence change protection. Make- Volina or equivalent
Supply and fix UPS for 30 min back up single phase AC input 160 to 260 V and out put 230 ± 1% of capacity 2 KVA complete all as specified and directed
Supply, installation, testing and comissioning of step down transformer 11 KV/433 Volts, 3 phase 50 Hz 250 KVA outdoor type, with off load tap changing arrangement on HT side to vary secondary voltage upto 7.5% in step (+ or -) 2.5% including suitable cable entry boxes both on HT to receive 95 Sqmm 3 core XLPE cable and on low voltage side to accomodate XLPE cable of suitable size complete in all respect with standard accessories and fitment confirming to IS:2026 Part-I of 1977. Primary side Delta and secondary side Star. The sailent feature of transformer shall be as follows:- (a) Transformer shall be oil immerse, naturally self cooled copper wound,winding core type MS radiator cooled tank complete with first fill of transformer oil plus 5% spare oil as per IS:335 of 1980 with cooling system.The temperature of oil shall not rise more than 50 degree centigrade to amient temp and 55 degree centigrade of winding.Transformer shall be painted with two coat of epoxy paint as per IS-632. (b) Transformer shall be provided with the followings:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs. (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Oil temperature indicator.
Material & labour, for transformer platform made out of rubble stone masonry in cement mortar 1:4 with 75mm thick cement concrete 1:2:4 type B-1 nominal mix using 20mm graded stone aggregate with rendering 15mm thick on stone masonary surfaces in cement mortar 1:4 finished even and smooth without using extra cement including necessary excavation, removal, returning and cement concrete 1:4:8 type D-2 nominal mix using 40mm graded stone aggregate in foundation including chain link fence with gate complete all as specified and as directed
Supplying and fixing out door, triple pole, gang operated switch single bank, tilting type suitable to vertical/horizontal mounting consisting of hot dipped electro plated galvanised channel iron base with drop out fuse having 15 Nos insulators 11 KV, copper/copper alloy tinned contacts, copper or chromium plated MS arcing chains capable of making and breakign the magnetising current complete with horizonatal bar, GI pipe as down level coupling and operating handle with locking arrangements and drop out fuzes working voltage 11000 volts 400 Amps including testing complete all as specified and directed
Material and Labour for Earthing of machinery/equipment Installed at power house/substation, using 25 x 3 mm copper strip and copper plate of size 300 x 300 x 3 mm, as earth electrode. (for equipments)
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to GI earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost all as directed by Engr-in-Charge. (Note: GI strip & GI pipe beyond 7.5Mtr length from earth electrode shall be measured and paid separately).
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to GI earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost all as directed by Engr-in-Charge. (Note: GI wire & GI pipe beyond 7.5Mtr length from earth electrode shall be measured and paid separately).
Material and Labour for maintenance free chemical earthing system complete with UL464 approved copper bounded earth rod 17mm dia 3mm dia 3 mtrs long electrode buried in ground to bore holes 150mm dia. Vertically to a depth not less than 0.50 mtr below normal ground level including Provision to connect the earth continuity conductor with copper bounded earth rod as per manufacturer's design or all as directed including 6 kg NABLLAB certified back fill chemical compound for filling bore hole with min 6 kg of Hygroscopic Gel. The ground enhancement chemical may be used in place of back fill compound as required and chemical may be used in place of back fill compound as required and manufacturer's recommendation to obtain below 1.0 ohms earth resistance value. A layer of 250-300mm soil (vegitable/cotton soil) is also required outside earth bore including necessary ingradients and water during process obtain desired value. The earthing strip of size copper 20x3mm up to length of 7.5 mtr up to test point from copper rod is also included test point terminal block should be made of Gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm long hexagonal head screw complete. The scope include iron frame of size 20x20mm fixed with hinged with Pit cover of 300mmx300mm made of cast Iron as per company standard shall be as recommended buy manufacture complete all as specified. Make-JMV/Pargati electrocom/Enove Note : (i) Payment shall be made only after satisfactory testing to the entire satisfaction of GE. The contractor has to make alternate earthing in case test result not found satisfactory without any extra cost and rate should include the cost of that provision of earthing. (ii) Contractor shall submit 1 years guarantee for earth resistance below 1 ohms and earth neutral voltages less than 1 volts.
Supply, installation, commissioning and testing of Diesel Engine driven water cooled generating set of capacity 200 KVA, 415 Volts, BHP as per manufacture recommendation, AC Supply, 50 Hz, 3 phase 4 wire, 0.8 PF at low temp high pressure, speed 1500 RPM mounted on common base frame with flexible coupling and meeting the requirement of IS-4722/BIS specification with CPCB approved acoustic enclosures fabricated out of CRCA sheets as per manufacture recommendation Sound proofing of enclosures is done with high quality foam conforming to IS-8183 for 75 dBT 01 metre complete including PCC foundation in all respect as per norms of OEM. DIESEL ENGINE :6 Cylinder Water cooled diesel engine of adequate capacity suitable to deliver 200 KVA power at 1500 RPM generally in accordance with latest BIS/IS Specification provided with blower fan, 12 volts self starting including maintenance free battery of suitable capacity, charging dynamo/alternator , air cleaner, diesel/oil filters, complete in all respect. The engineer shall be capable of takings 10% over load for one hour for every 12 hours running conforming to the environment (PROTECTION ACT 1986) (29 OF 1986) and as amended vide Gazette of India Notification Part II sections III Sub Section (I) dated 12 Jul 2004. (A) ENGINE INSTRUMENT PANEL : All relevant information shall be displayed on a complete panel for easy monitoring of lubricant, oil pressure, battery charging, ammeter, hours meter, starting switch etc (B) FUEL TANK : In built fuel tank adequate capacity for 12 hours running with stop cock, drain plug as per recommendation of OEM
(C) ALTERNATOR : 200 KVA at low temp high pressure, 3 phase 50 Hz, 415 volts, AC supply, 0.8 PF at 1500 RPM, this shall be self excited screen protected and drip proof type brushless, conforming to relevant IS/BIS code as per latest manufacturing schedule. (D) CONTROL PANEL : The standard control panel shall be built in acoustic enclosures with the following accessories complete wired with suitable size of copper cable with following accessories:- (i) MCCB of suitable rating with over load and short circuit protection. (ii) Digital Ammeter (iii) Digital Voltmeter (iv) One set of indicating LED lamps RYB and fuses. (v) Frequency meter, RPM meter, Hour meter, Fuel level indicator. (vi) KWH meter of suitable capacity digital type for 3 phase 415 volt AC supply and for unbalanced load. (vii) Microprocessor based controller KG745 controlling various Mechanical &Electrical protection with display and indication of Electrical and mechanical Parameters areas follows. (E) Civil works:-All civil works including PCC platform and related to foundations including of panel and equipments including making good and existing structure of disturbed during installations and commissioning of genset .The depth of the foundation and PCC as recommended by the manufacturer/ OEM designed.
(F) ACOUSTIC ENCLOSURE: Acoustic enclosure should be as per manufacturer recommendation. The walls of enclosures will be insulated to get 75 dba at 1 meter sound leveled as recommended by ministry of environment and forest. The enclosure shall have following provisions : (i) Fitting arrangement (ii) Point for neutral and body earthing (iii) Fuel drain (iv) Lub oil drainage (v) Air breather (vi) Easy stop push button (vii) Panel meter viewing window (viii) Canopy light as per OEM recommendations (G) Note : (i)The Gen set must be affixed with label meeting the following requirement ( The label shall be durable and legible) (a) Name and address of the engine manufacturer. (b) Statement that this engine conforms to the environment (PROTECTION) (c) Type and approval certificate number. (d) Date of manufacturing of Gen set. (ii) The complete DG Set including Engine/ Alternator shall be factory assembled by manufactured or its authorizes dealer as approved for assembling of the DG Set. A certificate in this connection shall be submitted to the GE. (iii) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates.
(iv) The quoted rate shall be deemed to be inclusive of first fill of engine oil (v) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS in presence E/M officer detailed by accepting officer ,all testing arrangements /equipments shall be made available by the contractor for tests .POL shall be arranged by Contractor for testing and cost deemed to be included in quoted rate (vi) The contractor shall arrange for artificial load / resistive load / water load for testing for final testing of DG Set at site and the cost is deemed to be included in quoted rate. (vii) DG set should be sound proof as per latest policy. (h) Retrofit emission control device of suitable capacity to be provided in DG sets within overall cost voated by the contractor if applicable as per policy.
Intrernational Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .