| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.1 L+₹17,232.50 (1.93%)Rejected-Finance BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L2 | Rejected-Finance Being other than lowest Bidder | |
| 3 | L3₹11.9 L+₹2.9 L (32.7%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance Being other than lowest Bidder | |
| 4 | L4₹14.2 L+₹5.2 L (58.4%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being other than lowest Bidder | |
| 5 | L5₹18.4 L+₹9.5 L (106.1%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest Bidder |
Tender Value
₹13.2 L
EMD Value
₹26,460
Closing Date
16 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) LEH
GE (AF) LEH PIN- 194101
REPAIR MAINTENANCE OF HEATING APPLIANCES AND CONNECTED WORKS AT 21 WING AF STN LEH UNDER GE AF LEH
2023_MES_611437_2
GE(AF)/LEH/T-47/2023-24
Open Tender
Entertainment/Musical Instruments
Item Rate
180 days
GE (AF) LEH
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) LEH
₹26,460
Yes
20 Feb 2024
24 Nov 2023
18 Dec 2023
25 Nov 2023
16 Dec 2023
2 Dec 2023
25 Nov 2023 - 1 Dec 2023
Amount
Disconnecting electrically thermic fluid boiler of capacity 2,00,000 Kcal/hr complete, de-scaling/decarbonising the coil as required and cleaning with kerosene oil in all respect and reassembling and testing of the same complete including replacing unserviceable spare parts and servicing , cleaning of burners of any make, including hose pipe as per site requirement with hose clamps cutting welding of boiler sheet and welding the same with existing / new sheet complete all as specified and directed by Engineer-in-Charge. Note :- The cost of de-scaling,burner servicing,hose pipe with clamps,cutting of boiler welding and fabrication work if required deemed to be included in quoted rates. Spares incorporated shall be measured and paid for separately under Srl Item No. 2.01 to 2.20
Ignition electrode as per site
Fuel filter element
Fuel pump as per site
Nozzle as per site
Photocell as per site
TPL pipe for diesel line as per site
Solenoid valve as per site
Contactor as per site
Temperature controller TC513 (selec)
Neon indication lamp as per site
Start button Rotary Type as per site
Sequence controller as per site
Star Coupling as per site
Ignition Transformer as per site
Fuel filter assembly as per site
RTD with cable
Pressure Gauge 0-150 PSI
S & F Ball Valve 15mm
S & F Ball Valve 25mm
S & F Ball Valve 50mm
Disconnecting electrically thermic fluid boiler of capacity 1,00,000 Kcal/hr complete, de-scaling/decarbonising the coil as required and cleaning with kerosen in all respect and reassembling and testing of the same complete including servicing, cleaning of burners of any make , including hose pipe as per site requirement with hose clamps cutting welding of boiler sheet and welding the same with existing / new sheet as required complete all as specified and directed by Engineer-in-Charge. Note :- The cost of de-scaling,burner servicing,hose pipe with clamps,cutting of boiler welding and fabrication work deemed to be included in quoted rates. Spares incorporated shall be measured and paid for separately under Srl Item No. 4.01 to 4.15
Fuel pump as per site
Ignition Transformer as per site
Sequence controller as per site
Ignition electrode as per site
Fuel filter element as per site
Nozzle as per site
Photocell as per site
TPL pipe for diesel line as per site
Solenoid valve as per site
Contactor of Make : Seimens cat part No MPCB1 3VU1340-INJOO
Contactor MNX-18., LB-1AN
Temperature controller as per site
Neon indication lamp as per site
Start button Rotary Type as per site
Star Coupling
Disconnecting electrically Space heater of capacity 60,000 Kcal/hr complete, de-scaling/decarbonising the burner and cleaning with kerosen in all respect and reassembling and testing of the same complete all as specified and directed by Engineer-in-Charge.
Nozzle
Fuel pump
Fuel filter element
Photo cell
Sequence controller as per site
Disconnecting electrically Space heater of capacity 200,000 Kcal/hr complete, de-scaling/decarbonising the burner and cleaning with kerosen in all respect and reassembling and testing of the same complete all as specified and directed by Engineer-in-Charge.
Nozzle
Fuel pump
Fuel filter element
Photo cell
Fuel filter assembly
Sequence controller as per site
Supply and filling of Thermic fluid of approved make suitable for Central Heating System in a barrel of 210 litres complete all as specified and as directed. Make : Cabol-32 of Bharat Petroleum , IOCL or equivalent
Supply and filling of Coolant, anti freezing of approved make complete all as specified and as directed. Make : Castrol / Mak / Servo
Disconnecting electrically and taking down burnt out electric induction motor and Repair/Rewinding of Electric induction motor of cap 3/5 HP 3phase 415 Volts make complete all as specified and directed by Engr-in-Charge
Disconnecting electrically and taking down burnt out electric thermic fluid circulation motor and Repair/Rewinding of Electric thermic fluid motor of cap 1 HP Three phase 415 Volts make complete all as specified and directed by Engr-in-Charge
S&F in repairs of of Fan coil unit of cap 4500/6000 KCal/Hr, PCB controlled with 3 Rows Deep copper coil in 3/8" construction including 12 mm thick pre - filter, DIDW Centrifugal blower with single phase direct driven motor including taking down old userviceable Fan coil unit complete all as specified and directed by engineer-in-charge.
M&L for Insulation of Copper tubing of size 3/8 " or 5/8" with 19 mm thick nitrile rubber Class O insulation complete all as specified and as directed
M & L for Insulation of MS/GI Pipe of dia 25 mm with PUF slab 30 mm thick with and including applying bituminuous compound and Aluminium cladding with 26 gauge Aluminium sheet after tightening the slabs with GI wire completeall as specified and as directed
M & L for Insulation of MS/GI Pipe of dia 40 mm with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete
M & L for Insulation of MS/GI Pipe of dia 50 mm with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete
Supply and lay in replacement of leaked/wornout/damaged MS Pipe of size 50 mm as with all fittings per site requirement as per satisfaction of Engineer-in-Charge
Supply and fix in replacement of leaked/wornout/damaged GI Pipe of size 25 mm as per site requirement as per satisfaction of Engineer-in-Charge
Excavation in trenches nexc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, erection of poles complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified.
Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point.
Repair to wiring of Main Panel for Electric Supply to Boiler/Space Heater and replacement of UNSV wiring, MCB/MCCB and other items in panel as per site requirement to make it proper Functional of Plant as per satisfaction of Engineer-in-Charge. Note: MCB/MCCB/Contactor/Switch/Lamp will be measured and paid separetly under relevant item of Sch A item
Supply only MCB SP of Cap 06 to 32 Amps Make: L&T/Havelles/Schenider/Indo Asian
Supply only of MCB TP of 63 Amps Make: L&T/Havelles/Schenider/Indo Asian
Supply only Contactor MCX 12 Make: L&T/Havelles/Schenider/Indo Asian
Supply only Single phase preventor assembly complete as per satisfaction of Engineer-in Charge
Supply and fix in replcement of UNSV Phase sequence Controller of Cap 63 Amps as per site requirement as per satisfaction of Engineer-in-Charge
Supply and fix in replcement of UNSV DOL Starter of Cap 3 HP/5HP as per site requirement as per satisfaction of Engineer-in-Charge Make: L&T/Havelles/Schenider/Indo Asian
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
M & L for Insulation of MS/GI tank of any cap of thermic fluid/Disesl tank vertical or horizontal installed at site with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete as per site requirement
Supply and fix in replacement of clamps for cable to make proper cable discipline inside boiler room including material required like clamps, nut, bolts or any other accessories to make it proper as directed by Engineer-in-Charge
Supply and fix in replacement of Suitable Heating Element as per site requirement including thermostat and other connection inside the diesel tank to avoid freezing of Disesl inside tank during winter as directed by Engineer-in-Charge
Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents
Top Mind Industries Pvt Limited
national engineering
SATISH AND CO
AGGARWAL ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .