| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹26.7 L+₹65,020 (2.49%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹27.8 L+₹1.8 L (6.73%)Rejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L3 | Rejected-Finance NOT BEING L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
REPAIR MAINTENANCE TO FOOT PATH, DRAIN, HARDSTANDING, SEWAGE SYSTEM INCLUDING CLEANING OF SEWAGE AT OTM ACCN OF ASC CENTRE NORTH 1 ATC, IBLUR, 49 MVH, 70 MAJORS, 598 ORs, MELLURE LINE AND EKLAVYA MESS UNDER AGE B R I IN GE CENTRAL BANGALORE
2022_MES_526130_1
8231E
Open Tender
Civil Works - Others
Item Rate
270 days
GARRISON ENGINEER CENTRAL BANGALORE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER CENTRAL BANGALORE
₹50,000
Yes
23 Aug 2022
25 May 2022
24 Jun 2022
25 May 2022
22 Jun 2022
8 Jun 2022
60 days
Amount
Demolition of plain cement concrete (unreinforced) in ground floors, plinth protection/path/pavings etc not exceeding 15 cm thickness. (below or above ground level) and removing debris outside MD land complete all as specified and directed.
Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for etc, cutting reinforcement steel to facilitate demolition of concrete including removing the materials out side MD land complete all as specified and directed.
Demolition of brick/concrete block work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc and removing debris outside MD land complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing debris outside MD landcomplete all as specified and directed
Demolition and breaking of 100mm to 150mm bore salt glazed stoneware drain pipes including PCC benching/ PCC complete all as directed.
Demolition and breaking of 200mm bore salt glazed stoneware drain pipes including PCC benching/ PCC complete all as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, manhole, sewage line, UG cable, water supply pipe line etc, area not exceeding 10 Sqm on plan and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, level course, sub base for hard standing etc complete all as specified and directed.
M&L for precast cement concrete block masonry in proportion mix 1:3:6, type C1, (using 20 mm graded granite stone aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
All as per item No 11 above but using serviceable precast cement concrete solid block, type C1, 1:3:6 (20 mm graded granite stone aggregate). Note :- Old serviceable PCC solid block retrieved under item No 03 shall be used.
Cutting into existing manholes for inserting new drain pipe, 150mm bore and making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B1 finished to match with existing complete all as directed.
M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab of drain, manhole etc and set in cement mortar 1:4 including necessary form work, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately)
S & F TMT steel bars 8mm or 10mm dia, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns/slabs, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work/stone masonry or concrete surfaces in cement mortar 1:4, mixed with water proofing compound by weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
"Supply only" integral water proofing compound (ISI marked) complete all as specified and directed. (Make : Dr FIXIT/Fosroc/choksey)
Supply and fixing underground Double Wall Corrugated (DWC) PVC pipe, 150mm nominal size (ID 148.50mm & OD 172.50mm), SN- 4, in any length, with rubber ring joints including all fittings, conforming to IS- 16098 (Part- 2) , laid in trenches and testing on completion complete all as directed.
Supply and fixing underground Double Wall Corrugated (DWC) PVC pipe, 200mm nominal size (ID 197.40mm & OD 230.50mm), SN- 4, in any length, with rubber ring joints including all fittings, conforming to IS- 16098 (Part- 2) , laid in trenches and testing on completion complete all as directed.
M&L for 75mm thick cement concrete 1:2:4 mix, type B2 (using 40 mm graded stone aggregate), as in floor/footpath/hardstanding etc finished even and smooth without using extra cement complete all as directed..
M & L for precast machine pressed interlocking paver block any shape and size conforming to IS- 15658-2006, 60mm thick, M-35 grade concrete with grey cement and no pigment, set and jointed in dry sand including providing 75mm thick dry sand filling below paver blocks complete all as directed
Opening and cleaning of obstructions/blockages manually in water closet (WC) including traps of WC, kitchen/bath any type & pattern inside house, cleaning of gully trap by removing grating & refixing including cleaning soil/waste pipe upto 1st manhole in ground floor and upto tee junction for other floors including removing access door and re-fixing in position, removing mud, waste materials, sludge/silt, liquid mud and foreign materials etc removing and depositing the same out side the MD land/premises and flush the same with water complete all as directed by Eng-in-charge. (Measurement will be carried out all as directed by Engr-in-charge). Note: - Contractor/Supervisor shall attend at complaint cell daily to collect the complaint slip from JE and completed slips shall be deposited on very next day for accounting the status.
Cleaning/clearing mechanically the sewage line of any description / SGSW pipe of size 100mm dia to 200mm dia at any depth , removing any type of blockage including desetling , descaling & dechocking with combine hydraulic operated sewer suction cum jetting machine mounted on LCV/HCV by using high pressure thermo plastic water jetting hose and through conical round shaped nozzle with piston action rodding from manhole to manhole or from manhole to septic tank / well through sewer line. (Measurement will be carried out all as directed by Engr-in-charge).
Cleaning of underground sewage line of any description/SGSW pipe of size 150mm dia by rodding from manhole to manhole or from manhole to septic tank/well including taking off manhole cover and cleaning of manholes of any size and depth and removing waste material/sludge to a distance of n.exc 50m and burrying the same in pit and refixing manhole cover in position after cleaning ( Measurement will be carried out each time depend on blockage ) Complete all as directed by Engr-in-Charge.
Cleaning of septic tank and soakage well (work in foul position) any size by dewatering, taking out mud/sludge/liquid from septic tanks, soakage wells not exceeding 1.5meter deep getting out and removing & depositing the sludge to a distance not exceeding 100meter in borrow pits, excavating borrow pits and covering the filled borrow pits with minimum 10cm thick layer of earth, and 2 cm thick lime on top surface to prevent spread out of foul smell. After taking out sludge and solid deposits, the inside of the septic tank, etc shall be cleaned with water complete all as specified and directed. Note:- Cost elements for excavation of earth work for borrow pit including returning, filling in and removal of surplus soil/earth shall be deemed to be inclusive in the quoted rate under this item.
Cleaning of septic tank and soakage well (work in foul position) any size by dewatering, taking out mud/sludge/liquid from septic tanks, soakage wells exceeding 1.5meter but not exceeding 3.00 meter deep getting out and removing & depositing the sludge to a distance not exceeding 100meter in borrow pits, excavating borrow pits and covering the filled borrow pits with minimum 10cm thick layer of earth and 2 cm thick lime on top surface to prevent spread out of foul smell. After taking out sludge and solid deposits, the inside of the septic tank shall be cleaned with water, complete all as specified and directed. Note:- Cost elements for excavation of earth work for borrow pit including returning, filling in and removal of surplus soil/earth shall be deemed to be inclusive in the quoted rate under this item.
Omkar Constructions
GKR and CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .