Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.3 LAccepted-AOC | 1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | 2₹31.7 L+₹4.5 L (16.3%)Rejected-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | 2 | Rejected-AOC BEING OTHER THAN THE LOWEST BIDDER | |
| 3 | MS FORWARD BUILDERS E 32/10/KKD Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in MES in appropriate class and category |
Tender Value
₹29.8 L
EMD Value
₹59,600
Closing Date
27 May 2024, 6:00 pmClosed
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
SPL REPAIR / REPLACEMENT OF AIR CONDITIONING PLANT AGAINST BER AT MH PANAGARH AREA UNDER GE PANAGARH
2024_MES_649769_1
8911/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PANAGARH
Pls refer Tender Documents
7 documents required · 7 mandatory
₹500
GE PANAGARH
₹59,600
Yes
13 Sept 2024
10 Apr 2024
4 Jun 2024
10 Apr 2024
27 May 2024
6 May 2024
Amount
Dismantling and taking down of existng 2 x 8.75 TR and 1 x 7.5 TR AC Indoor & out door unis including connecting cable, cooling tower, cooling pumps, ducting complete, starter panel, foundations GI pipe etc removing materials deposited to MES store yard with any damage for keeping in safe custody and making good distrubed surfaces of wall, floors, etc., complete all as specified and directed.
Supply, design, install, commissioning and testing of Running Air Cooled Packaged Air Conditioners units complete, comprising of Hermetically / Semi - Hermetically, sealed Reciprocating or Hermetically sealed Scroll (MULTI SCROLL) Compressors with microprocessor based control fitted inside the indoor unit & first charge of refrigerant & oil, air cooled condenser, fan section with statically / dynamically, balanced centrifugal blower driver by a TEFC squirrel cage three speed motor, multi rows, cooling coil of copper piping and refrigerant as required quantity including leakage testing, electrical interconnection between indoor and outdoor units suitable for operation on R-410a refrigerants and of nominal capacity 8.75 TR. The casing shall be factory made powder coated, Electrical panel board for backing units shall comprise of SFU's Fuses with suitable size, Voltage scanner, complete with overload, low voltage, high voltage & phase imbalance protection alongwith VI pads complete with all ancillary including MS painted stand for outdoor units of suitable size foundation (RCC Cubes with double vibrator pad and GI strip) and allied minor civil works as per instructions of Engr-in-Charge, complete all as specified and directed. Notes:- (a) Duct from plant room to OT room paid separately under relavant item (b) Duct design carried out by OEM shall be submitted by contractor & approved by Rep of accepting officer
All as per Item No. 2.00 above but STAND BY Air Conditioners units complete, complete all as specified and directed.
Supply, design, install, commissioning and testing of Running Air Cooled Packaged Air Conditioners units complete, comprising of Hermetically / Semi - Hermetically, sealed Reciprocating or Hermetically sealed Scroll (MULTI SCROLL) Compressors with microprocessor based control fitted inside the indoor unit & first charge of refrigerant & oil, air cooled condenser, fan section with statically / dynamically, balanced centrifugal blower driver by a TEFC squirrel cage three speed motor, multi rows, cooling coil of copper piping and refrigerant as required quantity including leakage testing, electrical interconnection between indoor and outdoor units suitable for operation on R-410a refrigerants and of nominal capacity 5.5 TR. The casing shall be factory made powder coated, Electrical panel board for backing units shall comprise of SFU's Fuses with suitable size, Voltage scanner, complete with overload, low voltage, high voltage & phase imbalance protection alongwith VI pads complete with all ancillary including MS painted stand for outdoor units of suitable size foundation (RCC Cubes with double vibrator pad and GI strip) and allied minor civil works as per instructions of Engr-in-Charge, complete all as specified and directed. Notes:- (a) Duct from plant room to OT room paid separately under relavant item (b) Duct design carried out by OEM shall be submitted by contractor & approved by Rep of accepting officer
Supply and installation of Aluminium duct of 22G along with 13 mm thickness aluminium foil face Nitril rubber insulation of class "O" type materilas including the paper supporting, adeshive, joint taping with all respect along with aluminium powder coated grill with O deg angle for supply & return Air distribution inside the OT room through the all corner return riger system, complete all as specified and directed.
Supply and installation of Aluminium duct of 24G along with 13 mm thickness aluminium foil face Nitril rubber insulation of class "O" type materilas including the paper supporting, adeshive, joint taping with all respect along with aluminium powder coated grill with O deg angle for supply & return Air distribution inside the OT room through the all corner return riger system, complete all as specified and directed.
Supply, fixing, testing and commissioning of Air supplied through terminal HEPA filters in the ceilig, centre of OT, the minimumm size of the filtration area should be 8' x 6' to cover the entire OT table and surgical team. The minimummsupply air volume to the OT (in CFM) should be compliant with the desired minimumm air change. The return air should be picked up / taken out from the exhaust grill located at suitable location and provided including diffuser grill etc., complete all as specified and directed. (NOTE : HEPA filters of efficiency 99.97% down to 0.3 microns or higher efficiency are to be provided in the OT and not in the AHU.)
S&F cotton canvas cloth suitable for connection for inbetween Air Coditioning machine & ducting connection, complete all as specified and directed.
S&F of aluminium powder coated return air grill without collar damper, complete all as specified and directed.
S&F of GI Duct damper, complete all as specified and directed.
S&F strip heater of 4 Kw with thermostate auto cut off system, complete all as specified and directed.
Supply, laying / fixing / connecting, testing and commissioning of LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured of size 70 sq mm 3.5 core electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) incl removing of old one, complete all as specified and directed. (For panel incoming)
Supply, laying / fixing / connecting, testing and commissioning of Cable of size 16 Sqmm 4 core with copper conductor PVC insulated round sheathed (flexible) industrial cable, complete all as specified and directed.
S&F of flexible Copper Control cabling between indoor and outdoor unit of size 4C X 10 Sqmm Flexible Control cable from Panel to IDU & ODU, complete all as specified and directed.
M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size for placement of OT Outdoor unit supply duct etc as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint, complete all as specified and directed.
M&L for Plain Cement Concrete 1:2:4 using 40 mm graded stone aggregate type B2, complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No. 3 of SSR Part I complete all as specified and directed and testing on completion.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm as earth wire electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No. 3 of SSR Part I complete all as specified and directed and testing on completion.
Dismantling and taking down of existing indoor LT control panel incl disconnecting of cable, foundations, clamp etc complete, removing materials without any damage for keeping in safe custody & transported to MES store yard and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Supply, install, connect, test and commissioning in repair indoor type floor mounting panel factory made CPRI approved with suitable size to accommodate the following accessories and fabricated out of CRCA sheet of 2mm thick including single door system lockable / openable by bolts from front side, louvers & air vent gasket for natural flow of air. ‘U’ type gasket shall be used where reqd. completely, one side & bottom portion cable alley system, front openable, weather, dust and vermin proof and applying two coat of epoxy powder coated sprey paint over a coat of red oxide primer and necessary foundation work, eletric connection etc. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system. Provn for cable glands and PCC foundation with solid Copper bus bar (not less then 250 Amps) electrolytic grade having earthing strip at(left & right) both sides of panel & panel mounted on separate 50 x 50 x 6 mm MS angle iron frame (for fixing of panel) and applying two coat of epoxy powder coated spray paint over a coat of red oxide primer, panel frame grouting in PCC, complete all as specified and directed. Note:- PCC shall be paid separately under relavant item
OUTGOING : (a) MCCB 4 poles 63 Amp, 16 KA with thermal magnetic release with all protection accessories - 03 Nos (b) MCB SPN 32 Amps, 'C' Series 10kA, 240 Volts and to be housed in DBs complete - 02 Nos
S&F copper refrigerants piping (Inlet & Outlet) suitable for 8.75 TR & 5.5 TR capacity package Air Conditioner plant, complete all as specified and directed.
M&L for stone dust dry sand filling for cable covering on under ground cable in duct incl spreading, leveling and hand punning, complete all as specified and directed.
M&L Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh including provision of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, size of grid 605 x 605mm including provision of Hangers 6 mm dia G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long, size of grid 605 x 605mm including dismantling the old unserviceable false ceiling, complete all as specified and directed.
Taking down carefully copper / aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing, complete all as specified and directed.
M&L concealed point wiring for light point/ fan point, one light/fan/call bell/lamp point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC , FRLSH insulated unsheathed cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including modular cover plate with frame of suitable size and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor PVC insulated, FRLSH unsheathed earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. (Note : Chess cutting and making good to disturb surface incl painting is included in quotated rate.)
M&L concealed point wiring for 3 pin 5 Amps socket out let points on independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC, FRLSH insulated unsheathed cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including modular cover plate with frame of suitable size and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor PVC, FRLSH insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. (Note : Chess cutting and making good to disturb surface incl painting is included in quotated rate.)
M&L concealed point wiring for 3 pin 5 Amps socket out let points on same board with other switches controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC FRLSH insulated unsheathed cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including modular cover plate with frame of suitable size and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor PVC FRLSH insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. (Note : Chess cutting and making good to disturb surface incl painting is included in quotated rate.)
M&L point wiring for light point/ fan point, one light/fan/lamp point controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC FRLSH insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel modular terminal switch boxes, modular cover plate with frame of suitable size and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. (Note : Chess cutting and making good to disturb surface incl painting is included in quotated rate.)
M&L wiring for 3 pin socket out let on independent Board controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers on modular cover plate with frame of suitable size and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. (Note : Chess cutting and making good to disturb surface incl painting is included in quotated rate.)
S&F Modular switch 1 way 6 A, 1 module, complete all as specified and directed.
S&F Modular socket 6 A -2/3 pin combined, 2 Module, complete all as specified and directed.
S&F Modular Switch socket Combination 16A, 6 pin, 3 module, complete all as specified and directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm three terminal suitable for 230 Volts AC 6 Amps, complete all as specified and directed.
S&F Modular Bell push, flush type, 5 amps, complete all as specified and directed.
S&F Buzzer, Ding dong, AC 230 Volts, single pole 230 volts, complete all as specified and directed.
S&F lamp holder, PVC / polycarbonate type with back plate straight or angular suitable for batten fittings, complete all as specified and directed.
S&F concealed wiring of two single core, 6 sqmm nominal cross sectional area multistranded copper conductor, PVC FRLSH insulated unsheathed 1100 Volts grade drawing in and including suitable size medium grade PVC concealed conduit (ISI marked) with 6 sqmm nominal cross sectional area multistranded copper conductor, PVC FRLSH insulated unsheathed 1100 Volts grade for earth wire, complete all as specified and directed. [Note : (a) Chess cutting and making good to disturb surface incl painting is included in quotated rate. (b) 2 Single core main wire & one single core earth wire alongwith necessary PVC Conduit & accessories will be measured and paid in one run.]
S&F concealed wiring of two single core, 10 sqmm nominal cross sectional area multistranded copper conductor, PVC FRLSH insulated unsheathed 1100 Volts grade drawing in and including suitable size medium grade PVC FRLSH concealed conduit (ISI marked) with 6 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed 1100 Volts grade for earth wire, complete all as specified and directed. [Note : (a) Chess cutting and making good to disturb surface incl painting is included in quotated rate. (b) 2 Single core main wire & one single core earth wire alongwith necessary PVC Conduit & accessories will be measured and paid in one run.]
S&F epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact, complete all as specified and directed.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact, complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection, complete all as specified and directed.
S&F MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection, complete all as specified and directed.
S&F MCB SPN 40-63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection, complete all as specified and directed.
S&F 18 W LED light fitting wall mounted batten 4'ft, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt, 6000K including necessary connection, complete all as specified and directed.
S&F Recessed mounted bottom opening LED cleanroom luminaire (1 x 4), CRCA powder coated housing including necessary connection, complete all as specified and directed.
M&L point wiring for light point / fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. (Note : Chess cutting and making good to disturb surface incl painting is included in quotated rate.)
M&L concealed point wiring for 3 pin 5 Amps socket out let points on independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC, FRLSH insulated unsheathed cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor PVC FRLSH insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. (Note : Chess cutting and making good to disturb surface incl painting is included in quotated rate.)
M&L concealed point wiring for 3 pin 5 Amps socket out let points on same board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC FRLSH insulated unsheathed cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor PVC FRLSH insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. (Note : Chess cutting and making good to disturb surface incl painting is included in quotated rate.)
M&L wiring for 3 pin 15/16 Amps socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc., complete all as specified and directed. (Note : Chess cutting and making good to disturb surface incl painting is included in quotated rate.)
S&F switch piano flush type, single pole, 5/6 Amps, one way, complete all as specified and directed.
S&F switch socket combination 2 in 1 multipurpose 5 pin, (6 Amps ) flush type controlled by one switch, complete all as specified and directed.
S&F socket outlets 2 in 1, 3 pin, 5/6 Amps flush type 230/240 V, complete all as specified and directed. (For Same Board only)
S&F switch socket combination 5 in 1, 6 pin, (5/16 Amps) flush type controlled by one switch, complete all as specified and directed.
S&F stepped type electronic fan regulator (5 step) flush type 240 Volts, ISI marked, complete all as specified and directed.
S&F ventilating exhaust fan 300 mm sweep 230 volt AC complete with louver and all accessories connected with twin core twisted flexible copper conductor of suitable size, complete all as specified and directed.
S&F Bldg security light fittings 25 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with three core round shape flexible copper conductor through flexable PVC pipe of suitable size, complete all as specified and directed.
M&L wiring for circuit/submain alongwith earth wire with FRLS is PVC insulated multistranded copper conductor, single core cable in surface/ recessed as required 2x4.0 sq. mm + 1x2.5 sq. mm earth wire and including PVC concealed conduits and fittings of medium grade etc., complete all as specified and directed. (For Medical equipment / Instrument's). [Note : (a) Chess cutting and making good to disturb surface incl painting is included in quotated rate. (b) 2 Single core main wire & one single core earth wire alongwith necessary PVC Conduit & accessories will be measured and paid in one run.]
S&F epoxy powder coated sheet metal enclosure for DBs, single door, Single pole and neutral 240 V, 20 Amps with earth plug, complete all as specified and directed. (For Medical equipment/Instrument's).
M/S Ali Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .