Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PRAGATHI PRIDE APARTMENT 3 4 520 FLAT NO 203 BARKATPURA HYDERABAD 500 027 | HYDERABAD | TELANGANA | 500027 | Admitted-Finance |
| 2 | Admitted-Finance H NO 5 117 BODUPPAL INDIRA NAGAR COLONY GHATKESAR MANDAL R R DIST 500 092 | MEDCHAL MALKAJGIRI | TELANGANA | 500092 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹21,770
Closing Date
7 Nov 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GDG Prasad Raju, Sc F, CCE
CCE (RnD) Estates South Chandrayangutta Hyderabad - 05
Provision of 250 KVA Servo Stabilizer and Connections for Radar Operation at P2 Site, Mahakalpada
2022_DRDO_718437_1
CCEESTS/ENQ/CHP/EnM/P2 Site/74/ 2022-23
Limited
Miscellaneous Works
Item Rate
180 days
Mahakalpada
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
CCE (RnD) Estates South
₹21,770
Yes
17 Nov 2022
17 Oct 2022
8 Nov 2022
17 Oct 2022
7 Nov 2022
17 Oct 2022
Suppy, test and commissioning of 433 V, 250 KVA Servo stabilizer as per SCHEMATIC DIAGRAM, specifications & Data Sheet attached.
ii) Supply, laying and commissioning of following size 1.1KV garde XLPE insulated amoured aluminium conductor under ground cable. In built up cable trench/already laid RCC hume pipe or on cable tray/through GI pipe with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, proiding protection with sand and bricks at sides and top and cable route markers at every 15mtr interval and also at the turnings. The cable shall confirm to IS 7098/Part I. a) 3.5C X 185 Sq.mm
iv) Providing indoor ordinary end terminations for the cable specified above with compression type Brase gland, lugs using crimping tool, insulation tape, identification tags etc., including end terminaton. a) 3.5C X 185 Sq.mm
vi) Providing maintenance free earth station with consisting of 40mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, seald at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5mtrs. Earth enhancement compound upto a depth of 2.0meters arround the electrode capsule Brick chamber & CI cover complete
vii) Supply and laying of following size earth strips including excavation and refiling of earth when laid in ground and with all fixing accessories when laid in trench with necessary interconnections with earth station and equipments. a) 50 X 5 mm GI strip
viii) Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid on the wall with necessary interconnections with earth station and equipments. a) 25 X 5 mm Copper strip laid in Ground
ix) Supply, installation of 600A 430V MCCB 4P incoming Double Door outdoor type LT panel in metal enclosures WALL / FLOOR Mounted including outgoing busbar system Containing 2 Nos. 8 way 250 Amp Vertical TPN DB with 200 A Copper Busbar for each phase With 2 Earthbar, 2 Neutral bar and Cable ties for Cable management,with 2 nos 250 A, 8 W, VTPN MCCB DB Supply of 3 Phase, 8 WAY, vertical TPN MCCB DB, as per the following specifications: A. Incoming: a. 250 A Thermal adjustable MCCB: 1 no b. Rating: 4 pole, 250 A, 25kA, 50Hz, 415VAC c. Protection: Thermal and Magnetic Protection B. Outgoing Feeders: a. 63 A TP C curve MCB: 4nos b. 63 A SP C curve MCB: 12 nos c. All outgoing MCBs shall be‘C’ curve, 240v AC, 10kA breaking capacity, with DMC housing, suitable for class-II tropicalisation (as per IEC) & approved by ISI or IEC. MCBs shall have integrated label holder, biconnect upper & lower terminals & air channels for low temperature rise. C. Bus bar: 250 A, Tinned Copper D. Constructional details of DB: DB shall be as per IS-8623 with latest amendment. DB shall have external earth terminal & mounting holes. Cable ties & wire leads for wiring incomer MCCB to respective phase & neutral buses shall be supplied and wired with single core 35 sqmm stranded copper cable with tinned copper lugs. Enclosure shall be IP-43& IK-09 with double door. DB shall have detachable cable entry gland plate on top and bottom side for keeping spare length of cables. All wires inside DB shall have ferrules for identification of circuit number. All unused openings shall be fitted with Blanking Plates. The DB shall be provided with 250 amp tinned copper bus bar for phase & neutral. Neutral & Earth bar shall be 8 way each & suitable for termination of wires with pin type cable lugs. All accessories like Gland/Lugs/Thimble etc .required for installation shall be supplied by Contractor. Complete with LED indicators voltmeter, Ammeter foundation, Earth connection etc. complete.
CHARAN ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .